Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹47.2 L+₹2.1 L (4.72%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹49.4 L+₹4.3 L (9.63%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹63.7 L+₹18.7 L (41.5%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
15 Jul 2021, 6:00 pmClosed
GE (NW) KUNJALI
Garrison Engineer NW Kunjali Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 400005
8394 REPAIR MAINTENANCE OF LIGHTENING PROTETCTION INCLUDING EARTHING AND OTHER CONNECTED ACCESSORIES UNDER AGE EM UNDER GE NW KUNJALI
2021_MES_452746_1
8394/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
26 Jul 2021
18 Jun 2021
17 Jul 2021
25 Jun 2021
15 Jul 2021
2 Jul 2021
18 Jun 2021 - 25 Jun 2021
Amount
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed .
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 1.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module (Make : schneider elect/legrand mosaic/anchor ave) complete for One light/fan/bell point controlled by one 5A switch complete including taking down existing old wiring incl all accessories, all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster
One light point controlled by one 5A switch
One Fan point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring (Work station for computer)complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/ Plaza
S & F modular switch 1 way 6A, 1 module complete all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular switch 1 way 16A, 1 module all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular socket, 6A - 2/3 pin combined 2 modules complete all as specified and directed. Make: Anchor/Roma/Legrand.
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed. Make: Anchor/Roma/Legrand.
S&F for modular fan step regulator, 120W - 2 modular complete all as specified and directed. Make: Anchor/Roma plus/Legrand
S & F Ceiling rose, PVC/polycarbonate insulated body type, 3 terminal, 240 volts, 5 Amps complete all as directed.
S&F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent Cat part in Seimens/C&S.
S&F MCB SP 40-63 Amps, 10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4085 96-98 or equivalent Cat part in Seimens/C&S.
S&F MCB SPN 40-63Amps, 10KA 'C' Curve 240V complete all as specified and directed. Make: Legrand cat No 4086 18-20 or equivalent Cat part in Seimens/C&S.
S&F MCB Triple Pole 40-63Amps, 10KA 'C' Curve 415V complete all as specified and directed. Make: Legrand cat No 4086 59-61 or equivalent Cat part in Seimens/C&S.
S&F MCB Four Pole 40-63Amps, 10KA 'C' Curve 415V complete all as specified and directed. Make: Legrand cat No 4087 00-02 or equivalent Cat part in Seimens/C&S.
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 16 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 13 or equivalent Cat part in Siemens/C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 11 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 10 or equivalent Cat part in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 4 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing etc complete all as directed. Make - Legrand cat No 5077 35 or equivalent in Siemens/GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting VTPN 12 way, 440 volts with 100A Copper Busbar rating 440 Amps, for each phase, 2 Neutral bar, 2 Earth bar, dust and vermin proof with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB's as outgoing etc complete all as directed. Make - Legrand cat No 5077 38 or equivalent in Siemens/GE NOTE FOR ITEM No. 15 to 19 : MCB DBs shall be concealed in wall where ever posible including cost of removing old wooden box making good the surface to match with surrounding deemed to be included in quoted rates
S&F in repair of LED light fitting 20W, 230 V, 4 feet surface monted, indoor decorative aluminium extruded T- 5 LED batten, integrated type etc., complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed. Make- C & S cat part No. LTTB4F20WLED/W (Nakshatra series) , or equivalent cat part in Crompton/Wipro /Philips
Supply and fixing walll/surface mounted 10W LED, 2 feet batten fitting engineering plastic battern with white acrylic cover complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core copper conductor cable with suitable size and all as directed. Make : C&S cat part No. LTTB2F10WLED/W or equivalent in CG/ Wipro/ Bajaj / Philips
Supply and fixing in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCPL-36-CDL(2X2) / C&S cat No LTCRSLM36WATT 2X2 or equivalent Cat part in Surya / Philips
S&F in repair of Recessed full / Surface type LED 2X2 Luminaire 36 watt and CRCA powder coating housing with anti-glare diffuser, New deep back lit type surface mounting LED Luminaire provides high quality ecomonic energy saving lighting suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCTLSN-36-CDL(2X2) / C&S cat No LTCSP36WLED2X2 or equivalent Cat part in Surya / Philips
S&F in repair 32 mm bore, light grade, GI pipe bracket 1.2 mtr long, bend to shape including clamps made out of 50 x 6 mm flat iron and suitable size nuts, bolts and washers duly painted with two coats of aluminium paint over a coat of red oxide primer all as directed.
Supply & fix in repair of JEF Nimbus Early Streamer emission Air terminal (ESEAT). (i) ESEAT shall have a corrosion resistant stainless steel body (AISI 316 grade) capable of working in hazardous atmosphere. The Air terminal shall be non-radioactive and require no special licensing. The unit shall be fully autonomous (no battery, no external power supply required), collect energy from ambient electric field. (ii) ESEAT model must be tested in a high voltage laboratory in accordance with NFC 17 102 for a series of 100 shock waves equal to 325µs in order to measure the average gain in triggering. The average gain in triggering time (ΔT) obtained during the lab test for the offered model must be mentioned in the test report. (iii) ESEAT must work on negative as well as positively polarized discharges. (iv) ESEAT must have been tested for such discharges by a reputed (v)Indian Laboratory like Central Power Research Institute (CPRI). (vi) A dedicated tester should be avilable to test the healthiness of the ESEAT on request (Courtesy : Page No. 37, Point No. 3 of Clause 8.6 of the Revised NFC 17-102 version 2011). (vii) ESEAT Model : NLP 2200 - Radius of protection = 30 Mtrs Level of protection considered for the project = Level I.
Supply & fix in repair of Standard / Side mounting / Special Mounting Structure of GI + Aluminium of height 4.5 Mtrs with base plate suitable for roof mounting on concrete base and with FRP adapter without GUY kit complete all as specified and as directed.
Supply & fix in repair of Down conductor made of Copper / GI for lower impedance. It should have a minimum cross sectional area of 50mm² single core or equivalent size of GI strip and comply with IEC 62 305 standard. The down conductor shall be routed as directly as possible to the ground avoiding electrical shafts and sharp bends (minimum bending radius of 0,5m). Any metallic object located less than 1 meter shall be connected to it complete all as specified and as directed.
Supply and fix in repair test link box in order to disconnect the earth termination system for enabling measurements complete all as specified and as directed.
Supply & fix in repair of 4 Digit electromechanical Lightning Event Counter in WEATHER PROOF ENCLOSURE. The counter should give the number of strikes intercepted by the lightning arrester complete all as specified and as directed.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( averaSchneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note - Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
ELECTRO ASSOCIATES
DHARMESH ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .