Loading…
Loading…
Tender Value
₹3.1 Cr
EMD Value
₹3.1 L
Closing Date
23 Mar 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER SEC
17 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Similar nature of work means- "Any work of supply, installation, testing and commissioning of Railnet Network or any networking system using switches / Router/Wi-Fi/ IP based CCTV in govt. Sector/ Semi Govt. / Govt. undertaking / PSU - Indoor/Outdoor"
Tenderer should submit relevant document regarding completion and execution of any of the work mentioned in para 1.1 above for fulfilling Technical Eligibility Criteria of Similar Nature of Work.
30 conditions · 3 needing a document upload
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also,as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding.Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
JPO to prevent the damages of underground utilities :- The contractor shall conform to JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures (Ref:- RB Letter No. 2021/Tele/5(2)/3-Part (1) (3425647) dtd. 12.06.2023 ). The biddder is requested to go through the same (copy attached) before quoting their offer. The stipulations of the JOINT PROCEDURE ORDER in connection to procedure for undertaking digging work in vicinity of underground utility of various departments viz Signalling, Telecom and Electrical cables - preventive and post cable cut measures are to be strictly followed till the currency of the contract.
The balance sheet and all other financial documents attested/certified by CAs to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer is likely to be rejected without any further reference. (Ref:- GM/Engg. letter no. CE/G/Arb & Cont. Mgt./Tender Circular/Pt. I/317 dtd. 11.03.2025)
Before execution of contract agreement, the contractor must submit tender specific authorization issued by OEM for Schedule B item no. 1, 3, 4 and 6 clearly specifying that,1) Technical support for supply, testing and commissioning of the above equipment and/or software. 2) Technical support during the warranty period as and when required.
S&T portion of in connection to (i) Provision of CCTV in Goods shed at KGP, ROP, BLS, PKU, NSI, KHF, KKQ, PSOR and GPSD over Kharagpur division.(ii) Modernization / Upgradation of infrastructure of KGP Goods shed. (iii) Modernization/Upgradation of infrastructure of PKU Goods shed.
ST-OT-CCTV-Goods-Shed-09
ST-OT-CCTV-Goods-Shed-09
Open
Works - General
15 Months
Paschim Medinipur, West Bengal
₹0
₹3.1 L
23 Mar 2026
20 Feb 2026
9 Mar 2026
109 items across 4 schedules · ₹3,10,50,696.4 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of 1 KVA offline UPS with inbuilt 2X7.2 Ah battery backup & backup time as per the load having Automatic Voltage Regulator (AVR) with Wide Input Voltage Range 145-290V. Make- APC/Luminous/V-Guard/Exide/Microtek or better. | Numbers | 4.00 | 7,615 | 30,460 |
| 2 | Supply of 1 KVA online UPS with 60 minutes battery backup. The detailed specification is as under, I/P - single phase 160-260 volt, O/P voltage single phase 230+-0.5%, Output frequency 50+-0.5% Hz , Technology - IGBT-PWM or better, Overall Efficiency (%)- >/=90% & <94% without Inbuilt isolation transformer, Power Factor Load Supported - 0.8 or better, Degree of protection - minimum IP 20, Battery type - SMF/VRLA conforming to JISC:8702 (Pt. I, II & III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest or better. Minimum Guaranteed VAH - 1600 & other accessories - 6m cables, rack for batteries etc. Make- Luminous/V-Guard/Exide/Microtek or better. | Numbers | 3.00 | 27,639 | 82,917 |
| 3 | Supply of 2 KVA online UPS with 60 minutes battery backup. The detailed specification is as under, I/P - single phase 160-260 volt, O/P voltage single phase 230+-0.5%, Output frequency 50 +-0.5% Hz , Technology - IGBT-PWM or better, Overall Efficiency (%)- >/=90% & <94% without Inbuilt isolation transformer, Power Factor Load Supported - 0.8 or better, Degree of protection - minimum IP 20, Battery type - SMF/VRLA conforming to JISC:8702 (Pt. I, II & III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest or better. Minimum Guaranteed VAH - 3200 & other accessories - 6m cables, rack for batteries etc. Make- Luminous/V-Guard/Exide/Microtek or better. | Numbers | 1.00 | 49,332 | 49,332 |
| 4 | Supply of 5 KVA online UPS 120 minutes battery backup. The detailed specification is as under, I/P - single phase 160-260 volt, O/P voltage single phase 230+-0.5%, Output frequency 50+-0.5% Hz, Technology - IGBT-PWM or better, Overall Efficiency (%)- >/=90% & <94% without Inbuilt isolation transformer, Power Factor Load Supported - 0.8 or better, Degree of protection - minimum IP 20, Battery type - SMF/VRLA conforming to JISC:8702(Pt. I, II & III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest or better. Minimum Guaranteed VAH - 16000 & other accessories - 6m cables, rack for batteries etc. Make- Luminous/V-Guard/Exide/Microtek or better. | Numbers | 10.00 | 1,83,933 | 18,39,330 |
| 5 | Depth 1.0 meter, Width 0.3 meter. | Kilometre | 9.50 | 79,869 | 7,58,755.5 |
| 6 | Excavation of trenches including clearing of roots of trees etc. in hard/rocky soil by chiselling up to a depth of 0.5 meter to 0.8 meter and width 0.3 meter at the bottom. Supply & placing split RCC pipes with collar (for jointing pipes) of 100 mm nominal diameter to Spec. No. IS: 10262- 2019 or latest and IS-456-2000 as per SEM Drawing No. 15- D3 (Sheet-2) on sieved soil of 30 mm over cable and concreting(1:2:3) throughout the length upto a layer of 75mm approximately, then back filling the trench by digging and carrying earth from a distance of maximum 30 meters and then ramming of soil after cable laying. This also includes supply of collar and all the materials for concreting by the contractor. | Metre | 4300.00 | 589 | 25,32,700 |
| 7 | Excavation of trench in all kinds of soils including soft rocky area and clearing of roots of trees, rocks etc. to a depth of 1 metre and width 0.3 mtr. Track/ Pucca road/Platform crossing/ Level crossing as per SEM Drawing No.15-D5 including supply, transportation and laying of DWC pipes (full) with collar(for jointing pipes) Inner diameter/Outer diameter:103mm/120mm to Specification No.14830 (Part-2):2001 as per SEM Drawing No. 15-D4 and drawing of cable through DWC pipes with collar(for jointing pipes) including back filling and ramming after cable laying as specified in Tech. Circular No. 2 of 1988 & 01/2010 issued by CSTE/SER for S&T Cables or any latest guidelines. This includes repairing and plastering of Platform/Pucca road after cable laying. | Metre | 432.00 | 691 | 2,98,512 |
| 8 | Cutting and smoothening of inside surface of sizes 80 mm deep and 170 mm width for single/multiple cable chase in concrete or hard rocks or platform or cemented floor. This work includes laying and covering of cable laid in the chase with standard sizes Second class/Fly Ash brick placed and embedded longitudinally and plastered on the top of the bricks and curing 72 hrs. as per Drawing No. Con/SK/T/1 Note: Sundries materials such as Bricks, sand, cement etc., shall be supplied by the contractor at site and to be inspected by Railway Site Engineer before placing in the chase. Note: In case, chase cutting & smoothening are other than prescribed depth & width, Proportionate payment shall be released. | Metre | 730.00 | 256 | 1,86,880 |
| 9 | Horizontal Drilling by using manual pushing method (also called moling) at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge. Boring diameter should be atleast 110mm. The ground level shall be considered ignoring the bank height of the bank of the road. Note: DWC/HDPE/GI Pipe Supply is covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after laying of the cables into DWC/HDPE/GI pipe. | Metre | 300.00 | 1,023 | 3,06,900 |
| 10 | 1 HDPE pipe | Metre | 300.00 | 1,376 | 4,12,800 |
| 11 | Supply, transportation and fixing of Galvanised Iron Pipe (make: TATA/Jindal or better) with threaded collars (for jointing pipe) of 80 mm nominal bore Specification No. IS: 1239, Pt-1, 2004 thickness 3.2 mm medium grade, on bridges, culverts, drain or at places as per instruction of the site Engineer including supply and transportation of materials required for fixing the pipe as per SEM Drawing No.15-D7 on culverts and others including drawing of cables inside the pipe with masonry work at bridge entry and exit of the culvert and curing for 72 hours and pipes are to be clamped at max. 2 meter apart with drilling of holes on the pipe at 10 cm apart for S&T Cables. Note:- This also includes dismantling of released GI Pipe/Trough and released material should be returned at concerned store. | Metre | 294.00 | 1,018 | 2,99,292 |
| 12 | Supply of HDPE pipe as per Specification No. RDSO/SPN/TC/45/2013 Rev-2.0 or latest with OD/ID of size 40mm/33mm with suitable couplers, plugs, end caps, spacer, T band etc. as required during execution at the site. | Kilometre | 23.00 | 56,520 | 12,99,960 |
| 13 | Laying of S&T Cables (Signal/Quad/Power) in the excavated trench to Drawing No. CON/SK/T/5 or latest. Supply and transportation of 'U' clamps, anchoring of cable at every 10 metres interval with 'U' clamp on trench to Drawing No. CSTE/CON /CABLES/81 or latest. Supply, transportation, and placing of cable demarcating led belt to Drawing No. CON/SK/T/6 or latest punched at an interval of 30 metres and wrapped round each cable throughout the cable route and also at every track/Road/ platform crossing as above specified in Technical Circular No. 2/1988 & 01/2010 issued by CSTE/SER or as per latest guidelines and guarding the cables. Collecting empty drums with left over cable and to be returned to the stores of stock holder. Note: Cables will be meggered before & after its laying by contractor under supervision of Railway representative & Contractor will submit their reports. | Kilometre | 9.00 | 20,239 | 1,82,151 |
| 14 | Transportation including loading/unloading of Optical Fibre Cable along with HDPE pipe from the stores of SSE/Store or from any store of SE Railway to the site with care laying of HDPE pipe & blowing of OFC in it as per procedure and returning empty cable drums with or without left over cable to the stores of SSE/Store. It also includes supply and placing of warning & Detection tape orange colour of 100 mm wide printed in black as "CAUTION OFC CABLE" and laid throughout the trench as directed by the Representative of Railway. Note: OTDR of cables will be done before & after its laying by contractor under supervision of Railway representative & contractor will submit their reports. | Kilometre | 18.00 | 34,734 | 6,25,212 |
| 15 | Supply, transportation and fixing of RCC Cable Route Marker as per SEM drawing No. 15-D1 or latest. | Numbers | 60.00 | 576 | 34,560 |
| 16 | Supply of Steel Apparatus case Full height as per Drawing No. SK/Drg./OL/SER /198 or latest with E type lock . E-type lock & their key ward No. will be decided by site engineer as per Specification No. IRS: S-10/78 with Rev. 8 or latest. Supply of Hylam sheets is not covered under this scope. This includes supply of one key & handle for each four Apparatus Case or minimum one. | Numbers | 2.00 | 17,430 | 34,860 |
| 17 | Execution of Full Apparatus Case with earth excavation for pit, concrete foundation, surrounding earth work, erection and installation as per Drawing No. Con/SK/T/8 or latest and wiring to be done as per SEM Drawing No.19-D8 or as per direction of site engineer. Supply and fixing of Hylam sheet strip of appropriate size of 3 mm or 6 mm as required with hole for fixing of terminals, fuse blocks, relay and other accessories for signal/track circuit, termination of cable with number embossed ferrules, bunching of cables with PVC tape, proper soldering of cable armour with earth catenary wire, earthing of cable armour as required. Writing & terminal description including Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anticorrosive paint and subsequent two coats of Aluminium paint outside and red oxide inside and lettering etc. This also includes transportation of 25 mm/12mm Hylam sheet for shelf or as required and also includes minor modification in L/Boxes as per site requirement. The contractor shall supply 4 no. of foundation nuts & bolts of size 22 mm dia. x 450 mm long with 2 flat spring washers, with each nut & bolts, sand for filling up cable pit inside the apparatus case including plaster and bolts, nuts, screws, MS Clamps for fixing equipment/cable. Note: - Part payment shall be released after completion of- (i) Foundation- 40%, (ii) Erection - 10%, (iii) Wiring, earthing, testing - 20%, (iv) Painting, writings - 10%, (v) Plastering, sand filling & etc. - 10%, (vi) Commissioning - 10%. | Numbers | 2.00 | 9,147 | 18,294 |
| 18 | Supply of hot dip galvanized perforated GI cable tray, size- 300 mm X 50 mm X 1.6 mm (W X D X T) including Horizontal and vertical reducers tees, Cross members, Coupler, Nut, Bolts with down rod and other accessories including with cover complete as required and duly Suspended from the celling with GI suspended etc. It also includes supply of push to fit cover having side wall height 15 mm made out of 1.50 mm thick sheet. The thickness of galvanisation shall be minimum 70 microns. Note: In case of top cover is not supplied, only 80% payment to be released. | Metre | 990.00 | 689 | 6,82,110 |
| 19 | Installation of hot dip galvanized perforated GI cable tray, size-300 mm X 50 mm X 1.6 mm (W X D X T) including push to fit cover. The sundry materials if required any apart from the supply items shall also to be supplied. Note: In case of top cover is not supplied, only 80% payment to be released. | Metre | 990.00 | 69 | 68,310 |
| 20 | Supply of 20 pair, 0.63 mm diameter Underground Polythene insulated polythene sheathed jelly filled telephone cable as per Specification No. IRS:TC:41/97 Amd.3.0 or latest. | Kilometre | 1.00 | 1,87,830 | 1,87,830 |
| 21 | Supply of 6 Core Armoured Mono mode OFC cable as per latest TEC Specification or latest. | Kilometre | 23.00 | 22,614 | 5,20,122 |
| 22 | Supply of PVC insulated 3 Core 1.5 sq.mm Single core Multi-strands Copper conductor with ISI marked conforming to IS:694/2010 or latest. | Metre | 1000.00 | 58 | 58,000 |
| 23 | Supply of PVC insulated 3 Core 2.5 sq.mm Single core Multi-strands copper conductor with ISI marked conforming to IS:694/2010 or latest. | Metre | 10000.00 | 104 | 10,40,000 |
| 24 | Supply of Crimping tool for lugs/plug/straight/Angular plug RCA etc. suitable for 0.5 Sq. mm to 10 Sq. mm size. Make: Mex Press B16 or better | Numbers | 4.00 | 625 | 2,500 |
| 25 | Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. No. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing no. SDO/ RDSO/E&B/002 or latest are as under, (a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 No. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 No. (c ) Copper Strip of 200mm x 25mm x 6mm to exothermically welded to Earth electrode- 1 No.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 No.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 No. It also includes supply of (i) 35 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. | Set | 22.00 | 17,719 | 3,89,818 |
| 26 | Installation of Single Maintenance Free Earth pit as per RDSO Drawing No. SDO / RDSO/ E&B/001 which includes the following, a) Digging/Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. | Set | 22.00 | 6,098 | 1,34,156 |
| 27 | Supply of Class B & C Surge protection Device (SPD) -Type I & II with Visual Indication and Potential free contact to remote monitoring as per Specification No. RDSO/SPN/165/2023 Ver 4.0 or latest and IEC standard 61643 or latest and IEC 62304-5 or latest for Single phase 230V AC application with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 microseconds .One Set consists of 3 nos. of SPD (2 No. of B Class (L-N, N- E) and one no. of C Class (L-N) all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11- 2011 Standard or latest. Class B & C Surge protection device required with Three modules only. | Set | 24.00 | 6,007 | 1,44,168 |
| 28 | Installation of Class B & C Surge protection Device (SPD) -Type I & II. All fitting material to be provided by the contractor. | Set | 24.00 | 443 | 10,632 |
| 29 | Supply of multipurpose Computer chair. Model: CH-7B. Make: Godrej or better. | Numbers | 20.00 | 3,953 | 79,060 |
| 30 | Supply of Computer Table of size 1000 mm X 600 mm X 750 mm, Key Board pull out tray, drawer and top made of MDF. Model: C-13. Make: Godrej or better. | Numbers | 10.00 | 8,715 | 87,150 |
| 31 | Supply of LAN/Network (RJ11 & RJ45) cable tester. Make-D-Link/PA 70025 or better. | Numbers | 4.00 | 638 | 2,552 |
| 32 | Supply of Telecom Optical Fiber Tool Kit comprising of the minimum following equipment. i) Fiber Cleaver 18000 Cuts Type, ii) Tweezer, iii) Cable Sheath Jacket Stripper, iv) Buffer Tube/ Drop Cable Stripper, v) Utility Knife, vi) Screw Driver with Bits, vii) Alcohol dispenser, viii) Cleaning Wipes (Set of minimum 100 Nos), ix) Visual Fault Locator 1mW, x) Plier Needle Nose, xi) Long Nose Plier, xii) Allen Key Set 4 to 10mm, xiii) Drop Cable Stripper, xiv) cable Cutter upto 25mm, xv) Fiber Protection sleeves, set of 100, xvi) Fiber Power meter with adopter, xvii) multi-purpose swa, xviii) Number sticker, xix) spanner set, xx) adjustable wrench, xxi) curved claw hammer, xxii) head light, xxiii) brush, xxiv) Polishing disk, xxv) 1 no. Carry Bag. | Set | 2.00 | 25,557 | 51,114 |
| 33 | Supply of LaserJet multi-function printer (print, scan & copy) Mono Printer for A4 Paper Size as per following specifications. Connectivity USB & Wi-Fi, monochrome, Mobile Printing Capability through smart app, Print Speed Black - Up to 21 ppm, Duty Cycle monthly - Up to 10,000 pages, function type- print, scan & copy, Memory Standard: min. 64 MB, Processor speed 500 MHz, Input 150-sheet input tray, Output 100-sheet output tray etc. Make: HP/Canon/Epson or better. | Numbers | 2.00 | 22,572 | 45,144 |
| 34 | Supply of desktop/All in one PC as per following specifications. intel i3, 12th generation or better, RAM-8 GB, SSD- minimum-256 GB, display-21.5 inch, Window-10 or higher, graphics Type- integrated, Keyboard & mouse-wireless. Make- HP/Lenovo/Dell or better. | Numbers | 1.00 | 51,277 | 51,277 |
| 35 | Supply of desktop/All in one PC as per following specifications. intel i7, 10th generation or better, RAM-16 GB, SSD- minimum-256 GB, HDD-500 GB, display- 27 inch, Window-10 or higher, graphics Type- integrated, Keyboard & mouse- w i r e l e s s . Make- HP/Lenovo/Dell or better. | Numbers | 1.00 | 97,458 | 97,458 |
| 36 | Supply of Thermo-shrink Jointing (TSF) Kits for PIJF Underground Telecom Cable of different pair sizes 5/10/20/50/100/200/400 Pairs with copper conductors diameter 0.5mm/0.63mm/0.9mm conforming to RDSO Draft Specification No. RDSO/SPN/TC/57/2015 Rev.1, Amd.1.0 or latest. | Numbers | 10.00 | 3,264 | 32,640 |
| 37 | Execution of Straight joint on Quad cable/ jelly filled Telecom cable using Thermo-shrink/Universal jointing kit (RTSF). This includes excavation of cable joint pit of size 1.5 m X 1.5 m X 1.2 m for jointing of cables, back filling and ramming after jointing. After jointing, the cable through test such as insulation test, continuity test etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing the contractor has to redo the joint free of cost. Note: In case jointing is required to be done in the Location boxes, then 80% payment will be released. | Numbers | 8.00 | 1,437 | 11,496 |
| 38 | Supply of Fibre Distribution Management system (FDMS)/LIU for 12 Fiber complete with all accessories such as patch cord & pigtail as per TEC Spec. GR/FDM/01/02 April'2007 or latest. This includes supply of installation accessories as per technical specification. | Numbers | 48.00 | 2,604 | 1,24,992 |
| 39 | Installation, splicing and commissioning of Fibre Distribution Management system (FDMS) for 12 Fiber complete with all accessories with patch cord & pigtail as per TEC Spec. with latest amendment. The sundry material if required any to be supplied by contractor. | Numbers | 48.00 | 2,086 | 1,00,128 |
| 40 | Supply, transportation and installation of joint enclosure for 6/12 fibres optical fibre cable complete with all accessories including sealing with mechanical clamp facility for splicing of Optical Fibre cable. | Numbers | 46.00 | 1,502 | 69,092 |
| 41 | Splicing of Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer. | CORE | 816.00 | 152 | 1,24,032 |
| 42 | Supply, transportation and installation of RCC joint chamber with two piece top cover and bottom cover with holes for drainage and cable entry, as per Drawing No. RDSO/TCDO/COP-21 or latest. This includes trenching for jointing pit of size min 1.5 m X 1.5 m X 1.2m for all types of soils, back filling and ramming of the pit after placing the joint closure and cable loop in the chamber including dry sand upto 600mm height without causing any damage to same and consolidation of soil as well as disposal of excess soil. | Numbers | 4.00 | 4,811 | 19,244 |
| 43 | Supply of 20 Pair krone type DP Box with disconnection and reconnection facility for 0.63 mm dia. Copper conductor as per Specification No. IRS: TC/18-75 Ver.1 or latest with screw type terminal as per IRS: S-23 or latest. | Numbers | 6.00 | 1,271 | 7,626 |
| 44 | 20 pair C.T. Box/Krone type DP Box | Numbers | 6.00 | 916 | 5,496 |
| 45 | Supply of covered 19" racks 42 U complete with all fitting for housing the subrack SDH ADMs & PD Mux or other equipments as per instruction of Railway Engineer fully wired including, Power supply distribution system, DDF, Internal wiring and other accessories, runway ladder etc. or for other application. The components of the rack are specified below- (i) Rack size 2035 HX 600 WX 600 D (ii) Fixed side panels 42U X 600 D (iii) Front glass door plain 42U X 600D (iv) Rear MS door plain 42 U X 600W (v) Levelling screws-4 Nos. (vi) Compact Fan Module working with 48 V DC or other voltage - 2 Nos. (vii) Earth connecting kit-1 No. (viii) Cable manager with cable loops-2 Nos. (ix) Krone mounting bracket-01 No (x) Caster with breaks-2Nos (xi) 20" length 1" width 5 mm thickness copper strip with 12 Nos. of holes including SS bolts & nuts for every hole to connect cables- 2 Nos. (xii) 10A single pole DC MCB-2 Nos. (xiii) 6 A single pole DC MCB-2 Nos etc. | Numbers | 2.00 | 35,914 | 71,828 |
| 46 | Supply of 24U Rack with 19 inch standard dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D-Link, or better | Numbers | 10.00 | 21,437 | 2,14,370 |
| 47 | Installation, testing & commissioning of 24U/42U rack with 19 inch standard dimension as per instruction of Engineer in charge. It includes all the accessories for fixing of the same. | Numbers | 12.00 | 1,955 | 23,460 |
| 48 | Supply of 9U Rack with 19 inch standard dimension, wall mounting, front glass door with lock and two key, with rack fixing Multi point AC power strip, cable organiser with wall fixing screws. Make: CP Plus, D-Link, or better | Numbers | 36.00 | 6,153 | 2,21,508 |
| 49 | Installation, testing & commissioning of 2U/3U/4U/6U/9U/12U rack with 19 inch standard dimension as per instruction of Engineer in charge. It includes supply of all the accessories for fixing of the same. | Numbers | 36.00 | 503 | 18,108 |
| 50 | Supply, Installation & Commissioning of industrial grade 04 Port Router as per Specification No. RDSO/SPN/TC/84/2008 or latest with accessories. | Numbers | 1.00 | 59,799 | 59,799 |
| 51 | Supply of 24 port L-2 Non-PoE switch with 2 SFP ports with 3 years warranty complying Specification No. RDSO/SPN/TC/83/2020 Rev.2.0 or latest. Make: Cisco or similar. | Numbers | 24.00 | 27,579 | 6,61,896 |
| 52 | Supply of 24 Port L2 PoE Switch with 2 SFP modules with 3 years warranty complying Specification No. RDSO/SPN/TC/83/2020 Rev.2.0 or latest. Make: Cisco or similar. | Numbers | 2.00 | 49,221 | 98,442 |
| 53 | Supply of 2 MBPS Leased Line Modem as per Specification No. RDSO/SPN/TC/80/2020 Rev.2.0 or latest. Each pair consists of one G.703 & V.35 Unit. | Pair | 2.00 | 18,122 | 36,244 |
| 54 | Supply of 5m length SC to SC Single Mode Simplex/Duplex Fibre Optic Patch Cable | Numbers | 70.00 | 203 | 14,210 |
| 55 | Supply of STP (Shielded Twisted Pair) CAT-6 Cable compliant with TIA/EIA- 568-B2-1 or latest. | Metre | 10675.00 | 40 | 4,27,000 |
| 56 | Supply of UTP CAT - 6 cable, having bare Copper Conductor of diameter 0.5 mm, Suitable for Gigabit Ethernet TEC Specification No. G/WIR 06/02 or latest. | Metre | 4575.00 | 17 | 77,775 |
| 57 | Supply of RJ-45 connector. Make: D-link or better. | Numbers | 1200.00 | 6 | 7,200 |
| 58 | Supply of Push button telephone single with caller id facility. Make: Beetel M 53/ Binatone Concept 700/Panasonic KXTX 880MX or better. | Numbers | 40.00 | 896 | 35,840 |
| 59 | Supply of IO Box with all accessories. Specification: Type: 1x Keystone Jack + 1x Gang Box + 1x Single Socket Face Plate, Suitable for CAT6 / CAT6E, Connector Type: Ethernet, RJ45. Make: D-Link/Digisol/Digilink or better. | Set | 110.00 | 270 | 29,700 |
| 60 | Fixing of IO Box as per instruction of Engineering in charge. | Numbers | 110.00 | 17 | 1,870 |
| 61 | Supply and installation of 32 channel NVR as per specs No. 10.2 of RDSO specs No. RDSO/SPN/TC/65/2021 Version 6.0 or latest. | Numbers | 12.00 | 37,617 | 4,51,404 |
| 62 | Supply of 5 meter length 4K High speed HDMI Cable. | Numbers | 10.00 | 625 | 6,250 |
| 63 | Supply of 1G SFP module for 20 KM transmission working on single/dual fibre and should support all the software features, environmental standards and security features as mentioned in RDSO technical document no STT/TAN/IP-MPLS/2020 Ver2.0 or latest. | Numbers | 156.00 | 3,794 | 5,91,864 |
| 64 | Supply of 25mm (1 inch) (PVC casing capping in rectangular shape with separate Casing & Capping, double lock, heavy duty & ISI mark with IS:14927 or latest with minimum 1 mm thickness. | Metre | 900.00 | 35 | 31,500 |
| 65 | Supply of 25 mm (1 inch) PVC conduit pipe rigid plain ended conduit size IS:9537 (part-3) or latest and 9537 (Part-1) 1980 with latest amendment ISI marked with minimum 1.2 mm wall thickness & minimum one socket at every 3 meter pipe. | Metre | 5800.00 | 27 | 1,56,600 |
| 66 | Chase cutting in floor/wall and restoring of floor/wall with plaster for concealing of 50 mm./25mm conduit pipe (covered separately) in floor/wall then painting with matching colour as per existing colour of the floor/wall. | Metre | 750.00 | 68 | 51,000 |
| 67 | Transportation and fixing of PVC Conduit pipe/channel/casing caping on wall or structure with drawls of Telecom/Power/Data cable with proper finishing. This includes supply of fixing materials including flexible pipe/bend etc. as required during course of execution. | Metre | 6700.00 | 15 | 1,00,500 |
| 68 | Supply of minimum 4 way 6A socket Power Strip/Power Extension board/Spike buster/spike guard with 3 led spike buster indicators for earth/neutral connectivity, ground open indicator and surge protection having minimum 3 meter chord power cable as per IS :7098 (part l):1988 or latest. Make-Havells/Crab Tree/ Anchor or better. | Numbers | 93.00 | 644 | 59,892 |
| Schedule total | ₹1,65,87,322.5 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
DetailsofInspectionAuthority_1.pdf
ATTACHMENT
IRGCC April 2022
ATTACHMENT
BankMandateForm.pdf
ATTACHMENT
BankGuarantee-converted.pdf
ATTACHMENT
LCform.pdf
ATTACHMENT
EngagementofretiredRlyEmpCertificate.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
SpecificationofIPbasedSIPNonExecutivephones.pdf Specification of SIP phone
ATTACHMENT
UDINinNITs.pdf
ATTACHMENT
JPOCableCut19FEB2024.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
SpecificationofIPbasedSIPNonExecutivephones.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .