Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being (L1) | |
| 2 | L2₹16.3 L+₹1.4 L (9.68%)Rejected-Finance | L2 | Rejected-Finance Other than (L1) | |
| 3 | L3₹17.9 L+₹3.0 L (20.5%)Rejected-Finance | L3 | Rejected-Finance Other than (L1) | |
| 4 | L4₹20.8 L+₹6.0 L (40.5%)Rejected-Finance | L4 | Rejected-Finance Other than (L1) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jul 2023, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM Chakeri
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION WORKS TO SNCOs AND ORs MD ACCN AT AGV AT AFS KANPUR.
2023_MES_605353_1
8625E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (AF) E/M CHAKERI
₹50,000
Yes
25 Sept 2023
24 Jun 2023
31 Jul 2023
24 Jun 2023
27 Jul 2023
8 Jul 2023
Amount
Taking down old unserviceable/deteriorated point wiring (batten/PVC conduit copper/aluminium, etc ) from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc complete all as specified and directed.
Taking down old unserviceable/deteriorated main switch /DB/AC Box of any capacity including accessories complete all as directed by Engineer in Charge.
M&L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.5 mm with earth dolly and bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good all disturbed surface to wall, floor etc by means of cement mortar (1:3) or plaster of Peris and to match / finish the existing surface either by using same colour distemper/ white / colour wash, puty, complete all as specified and directed for the following :- For one light/ fan
All as per item No 3.00 above but for one socket point controlled by one switch on independent board.
All as per item No 3.00 above but for one socket point controlled by one switch on same board.
All as per item No 3.00 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
All as per item No 3.00 above but one light point controlled by 2 way switches.
All as per item No 3.00 above but one bell/buzzer point controlled by one push button on the same board with other switches of independent complete all as specified and directed.
M&L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in existing conduit and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good all disturbed surface to wall, floor etc by means of cement mortar (1:3) or plaster of Peris and to match / finish the existing surface either by using same colour distemper/ white / colour wash, puty, complete all as specified and directed for the following :- For one light/ fan .
All as per item No 9.00 above but for one socket point controlled by one switch on independent board.
All as per item No 9.00 above but for one socket point controlled by one switch on same board.
All as per item No 8.00 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 Volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unshethed, copper conductor, stranded 1100 Volt grade cable as continuous earth lead complete all as specified and directed.
All as per item No 9.00 above but for one light point controlled by 2 way switch.
All as per item No 9.00 above but for bell buzzer point controlled by one push button on the same board with other switches of independent.
M&L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including PVC casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed for the following :- For one light/ fan
All as per item No 15.00 above but for one socket point 5 Amp capacity controlled by one switch on independent board.
All as per item No 15.00 above but for one socket point 5 Amp capacity controlled by one switch on same board with other switches including earth wire.
All as per item No 15.00 above but casing /caping for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and directed. Make : Cona / Havells / Anchor
S&F switch flush type single pole two way 5 Amps, 240 volts, white finish complete all as specified and directed. Make : Cona / Havells / Anchor
S&F switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified and directed. Make : Cona / Havells / Anchor
S&F socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and directed. Make : Cona / Havells / Anchor
S&F socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified and directed. Make : Cona / Havells / Anchor
S&F electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and directed.Make : Cona / Havells / Anchor
S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed.Make : Cona / Havells / Anchor
Receiving complaints from JE/ Engr-in-Charge lodged by the users/occupants of internal electrification nature and rectifying/repair of the fault in respect of main distribution board having MCBs , MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets by taking down the existing fitting and fixture and rectifying by removing connections from the system, faults in (surface /concelled), circuits, main switches, MCBs/DBs, any type of utility light fittings, lamp holders and other connected fixtures of internal electrification complete including providing stores i.e insulation tape, wire, screws, nuts as per the site requirement to rectifying the fault with regard to complaint lodged and refixing the fitting and fixture to their original position complete all as specified and directed. Note :- (i) Any copmplaint which is left out/unattendent 1-2 days by any means will be communicated to the JE incharge /AGE E/M with reason. (ii) Contractor shall provide the all type of T & P to each electrician for attending the internal electric complaints. (iii) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate. (iv) If any complaint has not been rectified/repaired to make in serviceable condition, then that situations complain will not be measured under this item . The same will be replaced, measured and paid under relevant item of BOQ.
S&F in replacement double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed. Make : Legrand / Schneider / ABB / L&T
Supply, fixing, testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in replacement complete all as specified & directed. Make : Legrand / Schneider / ABB / L&T
All as per item No 28.00 above but of DP 6 to 32 Amps.
All as per item No 28.00 above DP 40 Amps.
All as per item No 28.00 above but of TPN MCB 40 Amps.
S&F in replacement sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly on in concealed position complete all as specified and directed.Make : Legrand / Schneider / ABB / L&T
M&L for sub main wiring (in replacement) with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in PVC Non Metallic Conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note :- (i) Two single core cable, one run of earth copper conductor and taking down old wiring will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M&L for sub main wiring (in replacement) with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5sqmm drawn through in and incl suitable size PVC casing capping (20 to 25mm) and all accessories fixed on wall/floors surface along with 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down UNSV old wiring complete all as specified and directed. Note :- (i) Two single core cable, one run of earth copper conductor, one run of PVC casing capping and taking down old wiring will be measured and paid as one unit length.
M&L for sub main wiring (in replacement) with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in PVC Non Metallic Conduit with one 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note :- (i) Two single core cable, one run of earth copper conductor and taking down old wiring will be measured and paid as one unit length. (ii) PVC Conduit shall be measured and paid separately under respective item.
M&L for sub main wiring (in replacement) with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed on wall/floors surface along with one 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down UNSV old wiring complete all as specified and directed. Note :- (i) Two single core cable, one run of earth copper conductor, one run of PVC casing capping and taking down old wiring will be measured and paid as one unit length.
M&L for sub main wiring (in replacement) with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing MS/PVC conduit with one 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note :- (i) Two single core cable, one run of earth copper conductor and taking down old wiring will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M&L for sub main wiring (in replacement) with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing MS/PVC conduit with two single core 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Four single core cable, two single core of earth copper conductor and taking down old wiring will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI marked of size not less than 20 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc complete all as specified and directed.
All as per item No 39.00 above but 25 mm dia PVC conduit medium grade ISI marked
S&F in replacement energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 40 Watt ,Lumen OUTPUT NOT LESS THEN 100 LM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting all as directed including removing of UNSV tube light fitting complete all as specified and directed. Make: PHILIPS BN100C LED 40S-6500 PSU L120GR / Wipro Cat No LL24-541-XXX-57-XX / Havells
S&F in replacement energy saving LED 4ft Batten 20/22 Watt with a nominal system lumen output of 2400/2500 lumens and a minimum system efficacy of 100 lm/W with fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting and removing unserviceable complete all as specified and directed. The luminaire shall have a rate system lifetime of 40,000 burning hours at L70. . The luminaire shall meet IP 20 rating and PF > 0.95 complete all as specified and directed. Make: PHILIPS / Wipro / Havells
S&F in replacement energy saver LED smart batten fiting 10 Watt, 230 V, box type etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fiting and removing unsv backet with sketch fitting complete all as specified and directed. Make: PHILIPS / Wipro / Havells
S&F in replacement Endural LED bulk head fitting Plastic Body, heat resistant, with specially designed gasket complete all as specified and directed. Make : Philips Cat pat- WT140W LED7S NW PSU S1 PC / Wipro / Havells
S & F bldg security light fitting 36 watt LED with pressure die cast housing IP 65 suitable for scondary road/bldgs power consumtion should not be more than 35 watt and power factor should not be less than .90 complete all as per specified and directed. Make : Philips Cat Part No : BRP046 LED 36 CW MR S1 PSU GR / Wipro / Havells
M&L for bracket (in replacement) made out of GI pipe 25 mm dia light grade 1.2 meter long bent to shape for mounting of fitting including fixing arrangements by two number of MS clamp with two nut and bolts in each clamp complete with taking down old unserviceable bracket of any size all specifed and directed.
S&F in replacement switch piano flush type 5/6 Amps one way AC 230 Volts ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement switch piano flush type 15/16 Amps one way AC 230 Volts ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement bell push 5 Amps, AC 230 Volts ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement socket outlet 2 in 1, 6 pin 15 Amp flush type (Multi purpose) AC 230 Volts,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement socket outlet 2 in 1, 5 pin 5 Amps flush type (Multi purpose) AC 230 Volts ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement electronic fan regulators flush type on the exiting phenolic laminated sheet etc ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement ceiling rose 65x50mm two to three terminal AC 230 volts ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement buzzer,AC, 230 volts, single phase c,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement bell, ding dong, AC, 230 volts, single phase ,as per day to day complaint complete all as specified and directed. . Make -Havells/Leader/Anchor
S&F in replacement lamp holder insulated body with back plate batten/angle type for batten fittings ,as per day to day complaint complete all as specified and directed. Make -Havells/Leader/Anchor
S&F in replacement electronic ballast 36/40 watts 230 volts ,as per day to day complaint complete all as specified and directed. Make - Crompton/Havells/ Bajaj/Philips
S&F in replacement LED tube rod 36/40 watts 230 volts ,as per day to day complaint complete all as specified and directed. . Make - Crompton/Havells/ Bajaj/Philips
S&F in replacement starter AC 230 volts suitable for 36/40 watts fluiorescent tube light fittings ,as per day to day complaint complete all as specified and directed. Make - Crompton/Havells/ Bajaj
S&F in replacement MCB SP, 6 to 32 Amps 10 KA AC 230, C curve volts ,as per day to day complaint complete all as specified and directed. Make: Havells/Legrand/L&T/Siemens
S&F in replacement MCB SPN 20 to 40 Amps 10 KA AC 230, C curve volts ,as per day to day complaint complete all as specified and directed. Make: Havells/Legrand/L&T/Siemens
S&F in replacement MCB TPN 25 to 40 Amps, 415 Volt, 10 KA AC 230, C curve volts complete all as specified and directed. Make: Havells/Legrand/L&T/Siemens
S&F in replacement LED tube light fitting with all accessories MS powder coated capacity 22 W pre wired ,as per day to day complaint complete all as specified and directed. Make - Crompton/Havells/ Bajaj/Philips
S&F in replacement LED bulb of capacity not less than 10 watt suitable for lamp holder ,as per day to day complaint complete all as specified and directed. Make : Havells/ Bajaj/ Crompton/ Wipro
S&F in replacement metal plug socket industrial 2 pin and earth plug of 20 Amps 230 V suitable for AC box ,as per day to day complaint complete all as specified and directed. Make : Legrand/ ABB/ Havells/ L&T
S&F in replacement metal plug top industrial 2 pin and earth plug of 20 Amps 230 V suitable for AC box ,as per day to day complaint complete all as specified and directed. Make : Legrand/ ABB/ Havells/ L&T
S&F in replacement MCCB 63 Amps, 4 Pole, 415V, 25 kA , Ics =100 % Icu ,as per day to day complaint complete all as specified and directed. Make : Havells Cat No IHLE1ABF00663 / Schneider / ABB / Legrand
S&F in replacement MCCB 40 Amps, 4 Pole, 415V, 20 kA , Ics =100 % Icu ,as per day to day complaint complete all as specified and directed. Make : Havells Cat No IHLE1ABF0040 / Schneider / ABB / Legrand
S&F in replacement TPN 100 Amp, 4 Pole, 415 V, 25 KA ICS = 100% Icu ,as per day to day complaint complete all as specified and directed. Make : Havells cat No. IHLE1AB40100 / Schneider / ABB / Legrand
M&L for through vaccum machine removing to all dust partical from the panel board and meter boxes including detecting and taking out loose cable and wire from the panel board/ meter boxes fitments and after providing thimbling and lux reconnected in proper way and testing on load to avoid any short circuiting which painting of panel board in existing color by brush painting and proper setting to all panel cover by gasket/ lock screw/ Velding to hinges as required at site detail complete all as specified and directed.
S&F in replacement electronic meter tamper proof, LCD display, polycorbonate cover 230 V 10 to 60 amp accuracy class I , 50 Hz confirming to IS 13779 IP54 with parameter to show data, time, current reading, load, PF, Voltage, KWH complete all as specified and directed. Make: L&T/ HPL / ABB Note: Old un-serviceable Meter will be deposited by the contractor in E/M store yard.
All as per item No 71.00 above but 3 Phase complete all as specified and directed.
H S ENTERPRISES
M/s Sohanil Construction
M/s A S Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .