| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.9 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹47.4 L+₹96,551.55 (2.08%)Rejected-Finance | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹48.2 L+₹1.8 L (3.81%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹48.9 L+₹2.5 L (5.33%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹49.0 L+₹2.5 L (5.47%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L-5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jun 2024, 6:00 pmClosed
GE Rangia
GE Rangia C/O 99 APO Rangia
REPAIR IMPROVEMENT OF SUBSTATIONS PAINTING TO POLES AND OTHER CONNECTED WORKS AT RANGIYA AND CHANGSARI MIL STN
2024_MES_657300_1
8760/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
RANGIA AND CHANGSARI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹90,000
Yes
18 Jul 2024
1 Jun 2024
17 Jun 2024
1 Jun 2024
15 Jun 2024
10 Jun 2024
1 Jun 2024 - 4 Jun 2024
Amount
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 street light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/36 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 01 here-in-above, but for 60 Watt LED Street light, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing and heat resistant, IP 66 Flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 120 watts with pre wired and lens embedded PC cover having Top opening seperate driver compartment, with impact and corrosion resistant including thermal management in multiple optics and necessary mounting arrangements/ fixing bracket, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 4 Sqmm section, complete all as specified and as directed by engineer-in-charge.
All as per Item No. 04 here-in-above, but for cross-sectional area 6 Sqmm, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 25 Sqmm 4.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down the existing old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 35 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 50 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 70 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 95 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 120 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 150 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 185 Sqmm 3.5 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 16 Sqmm 4.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No. 07 here-in-above, but for cross-sectional area 10 Sqmm 2.0 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M&L for boring holes horizontally under road without damaging the road surface with the help of GI tubing not exc. 80mm bore dia for passing of UG cable, complete all as specified and directed by Engineer-in-charge. NOTE: GI Pipe will be measured and paid separately.
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Fly ash Bricks, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised Iron Pipe 40mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 23 here-in-above, but for 50mm bore (dia) GI Pipe, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 23 here-in-above, but for 80mm bore (dia) GI Pipe, complete all as specified and as directed by Engineer-in-charge.
Supply & Erecting in true vertical of Steel Tubular Swaged Pole Type 410-SP-31 (9.00 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws with and including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying two Coats of Aluminium Painting over a coat of Red oxide Primer including necessary earthwork in excavation in any type of soil, removal of surplus soil to a distance of not exceeding 50.0m, Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) as in Foundation of Poles filled upto ground level and Cement Concrete 1:2:4, Type B-1(20mm graded aggregate) as in Coping/Padestal of Poles and finishing the Concrete surfaces Fair and Even including necessary Formwork as required at Site(s) and dismantling the existing old damaged LT pole of any type, complete all as specified and as directed by Engineer-in-charge. NOTE: Earthwork, Cement Concrete, etc. will not be measured and paid separately.
M&L for Aluminium conductor steel reinforced (ACSR) (size and type as required at site) drawn for overhead lines with permissible sags and providing jumper with and including copper binding wire or aluminium tapes, including stringing, tightening, etc., including dismantling the existing old unserviceable ACSR, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
Labour only for releasing Aluminium conductor steel reinforced (ACSR) (any size and type) of existing OH lines by un-binding from insulator of any description, re-fixing after stretching, re-stringing the conductor, removing excess sag, maintaining proper distance between conductors as ordered and binding with insulator with aluminium binding wire, complete all as specified and directed by Engineer-in-charge. NOTE:- Cost of binding wire is deemed to be included in unit quoted rate.
M&L for mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
Labour only for fixing in original position of disturbed/dis-aligned mild steel Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint, including dismantling the existing old unserviceable cross-arms, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of Stay assembly of 16mm dia 1.18m long stay rod complete with all accessories as shown in electrical plate No. 1, size of plate 230x230x6mm, complete all as specified and directed by Engineer-in-charge. Note:- Cost of 01 no 65 x 90mm porcelain, vitreous, white, brown or green Loop type insulator, Galvanised stay strand of 7/3.15mm size upto 7.50m long stay strands with clamps and bolts, excavation and concrete shall deemed to be included in unit quoted rate.
S&F in-repair of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of Shackle Type, porcelain, vitreous, white, brown or green insulator including one 31x3mm galvanised mild steel straps, washers, 12mm dia insulator bolts, washers and nuts, 75mm height, 90mm dia for 1100 volts grade, complete all as specified and directed by Engineer-in-charge.
Fixing only in-repair of porcelain insulator of any type, any size and of any description, complete all as specified and directed by Engineer-in-charge.
M&L for preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of synthetic enamel paint in alternate Yellow & Black Strips (5 Nos. Strip of 300 mm wide each) and remaining portion of Pole and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with One Coat of Aluminium Paint, including writing of pole numbers with black synthetic enamel paint, complete all as specified and as directed by engineer-in-charge.
S&F in-repair of MCCB 4 Pole, 415 Volts, 630 Amps, 50 Hz, conforming to IS/IEC 60898, with Thermal Magnetic release, overload, short circuit fault protection 3 phase, breaking capacity 50 KA, Ics=100% of Icu, with Spreader terminal of both ends, connecting and testing, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 400 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 250 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 200 Amp capacity MCCB, breaking capacity 36 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 160 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 125 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 100 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 36 here-in-above, but for 63 Amp capacity MCCB, breaking capacity 25 KA, Ics=100% of Icu, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead of 32x6 mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 40 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old damaged earthing, complete all as specified & testing on completion. NOTE:- (i) item includes the cost of 1.5 mtr length GI pipe for protection for GI earth lead. (ii) item rates includes the cost of 7.5 mtr GI earth lead.
All as per Item No. 44 here-in-above, but using 4mm dia galvanised steel wire procteded by GI pipe of 15 mm dia (light grade) as earthing lead, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 46 here-in-above, but using 4mm dia galvanised steel wire as earth continuity conductor, complete all as specified and as directed by Engineer-in-charge.
M&L for Jumper connection at cut point on LT OH lines with suitable size of ACSR conductor (not less than 6/1 x 2.56 weasel), by binding, wraping, providing alkathine sleaves of required length not exceeding 1.5 m including testing on completion and taking down the existing old damaged one, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 32mm bore (Dia) light grade GI pipe of 1.2m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 32x6mm) for fixing of building security/ street light fitting as per existing, complete all as specified and as directed by Engineer-in- Charge.
S&F in-repair of 10mm dia rigid PVC line separator/ spacer suitable for 2/3/4 LT line of wires, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of solar tubular battery of 75Ah, extra lead 20% higher backup, thicker tubes, long life, ultra low maintenance suitable for solar lighting, complete all as specified and directed by Engineer-in-charge. (MAKE- Exide/ Amaron/As existing)
S&F in-repair of solar charger controller (PWM) of 24V/10A, charge battery for solar panel, protects battery from over charging and protects panel from reverse current, complete all as specified and directed by Engineer-in-charge. (MAKE- Exide/ Amaron/As existing)
Supply only distilled water of 5lit packeged bottle for battery charger of solar light, complete all as specified and directed by Engineer-in-charge.
M&L for replacing damaged lugs of LT panel, preparing old rusted surfaces and applying one coat of synthetic enamel paint of approved colour by spray painting including cleaning the surrounding area and testing of earthing, complete all as specified and directed by Engineer-in-charge.
S&F in-repair of safety board made out of PVC of size 0.80x0.90m with and including printing safety instructions as directed by engineer-in-charge.
MS Gautam Construction and CO
HEMONTA DAS
M/S Rajkamal Enterprise
M/S NARAYAN ENTERPRISE
M/S SEWAK SINGH
ADITI CONSTRUCTION CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .