Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 18 MAIN MARKET SECTOR 13 KARNAL 132001 | KARNAL | KARNAL | HARYANA | 132001 | Admitted-Finance |
Tender Value
₹2.3 L
EMD Value
₹4,500
Closing Date
3 Dec 2019, 5:00 pmClosed
Raja Nagender Singh
Executive Engineer Electrical Division PWD B and R Karnal
Construction of EVM/VVPATs Warehouse in the campus of Mini Sectt. at Panipat (Pdg. EPABX and LAN System).
2019_HRY_106915_2
PWD/Elect-KNL/Elect-KNL/16624
Open Tender
Construction Works
Works
150 days
Karnal
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer Elect. Division PWD B and R
₹4,500
6 Jan 2020
21 Nov 2019
4 Dec 2019
21 Nov 2019
3 Dec 2019
21 Nov 2019
Amount
EPABX SYSTEM Supply Installation Testing Commissioning of IP-PBX with Cold Standby Configuration, User expandable to 300 Lines with Following Configuration: - 16 Analog Users 4 digital users 04 Analog Trunks 01 Operator Console with 22 Programmable Key a) Remote Maintenance Facility b) Web Based Managment Software c) Call Accounting Software-01 d) DISA & DOSA Facility e) Rack Mountable System f) Call Control Server / Applicatation should be equipped with Intel Based Processer including cost of all material and Labour required to complete the job in all respect upto the entire satisfacation of Engineer in Charge of the work Make : Avaya IP Office Enterprise/ Alcatel Lucent Omni PCX/ Unify Simens Hipath 4000
Supply Installation Testing Commissioning of Analog Phones including cost of all materical and Labour required to complete the job in all respect upto the entire satisfacation of Enigeer in charge of the work Make Alcatel Lucent/ Beetal M71
Supplying and Laying of 0.5 mm dia 2 pair telephone cable where ever required in prelaid cable tray, RCC hume pipes, DWC pipes or clamped in open manner as applicable, with suitable aesthetic dressing. Make Delton/Finolex
Supply and Installation of Single Telephone I/O Make Dlink/AMP
Supplying and Laying of 0.5 mm dia Annealed copper jelly filled 10 pair telephone cable where ever required in prelaid cable tray, RCC hume pipes, DWC pipes or clamped in open manner as applicable, with suitable aesthetic dressing. Make Delton/Finolex
Supply Installation Testing Commissioning, Termination & fixing of 10 pair MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection.Make Krone
Supply Installation Testing Commissioning, Termination & fixing of 20 pair MDF unit with Tag blocks in a fabricated CRCA powder coated junction box with pad-lock, provision for earthing, inclusive of IPM modules and GDT etc. for overcurrent and overvoltage protection. Make Krone
Supply & laying of 25 mm dia. Open/conceal manner medium gauge rigid PVC pipe with GI pulling wire.
LAN SYSTEM Supply Installation Testing Commissioning of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect. (HSR 31.80 Make: AMP / Schneider / D-link.
Supply Installation Testing Commissioning of UTP Cat-6 information outlet complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
Supply Installation Testing Commissioning of Face plate (Single / Dual) complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link.
Supply Installation Testing Commissioning of UTP Cat - Mounting Patch Cords complete in all respect up to the entire satisfaction of Engineer-in-Charge of the work Make: AMP / Schneider / D-link. 3 ft length
5 ft length
Supply Installation Testing Commissioning of Layer 2 Switch Access Switch : Port Type/ density/ Architecture All port on the switch should be of non blocking archtecture Swtich ports of 24 x 10/100/1000 Base T with additional 2x 10 G SFP + slots for Uplink Switch should be equipped with power supply switch fabric 92 GBPS and 68.8MBPS Should have minimum 256 MB D ram and 64MB Flash Resiliency Suport 802.1D spanning Tree and PVST+ , 802.1w,802.1s, Should have BPDU guard or Equivalent feature,Should Support LACP and LAG Should Support Uni directional Link Detenction (UDLD) Should support stacking of MIn 4 Switches Switching /Security /QosSupport private Vlan , Vlan tagging , 802.1V , RIP Minumum DHCP snooping IP Sources guard and Dynamic ARP inspection (DA) , Dynamic Vlan assignment , TI authentication : MAC based , We based and IEEE 802.1x Should support 16K MAC address Minimum 8 Hardware queues per port committed information rate (CRI) function provide bandwidth in increments as low as 64 Kbps Should Support policy based traffic redirection and IP route Should 802.1x with dynamic Vlans Should Vlan Should also have guest Vlan and web based captive portal.should support port Mirroring .should Support device management over IPv6 network network with SNMPv6,TELNETv6 SSHv6Should support DeSHCP Snnoping ,DHCP relaycket ,dynamiv ARP detection Should support DOS Protect ,Loop Detection and Prevention ,storm Control for multicase ,unicast and broadcast Should Support Flexicle traffic analysis with Netflow or sFlow Should Support minimum 1GMP query solicitation ,IGMP snooping (IGMPv1,v2 and v3) ,IGMP Snooping fast -leave ,MLD snooping(MLDDv1 and v2) Management Features: Support CLI,GUI SNMPV6 ,TELNET v6,SSHv6,NTPv6 Logo ready from day-1 SNMP V1 V2C and V3 and TPTP , LNDP server operating Conditions Operating Temp ) degree to +45 degree C operating humadity non condensing 10% to 90% Make Cisco WSC 2960X-24TD/ Junipper EX3300-24T/ Allied Telesis GS924MX/ Extreme 210-240-GE2
Supply Installation Testing Commissioning 12 U rack including power distribution kit, cable Manager complete in all respect HCL/Comrack/ PRESIDENT make with 2 fan.
Supply Installation Testing Commissioning of 24 port Cat-6 jack patch panel complete as per specification up to the entire satisfaction of Engineer-in-Charge of the work AMP/HCL/ Panduit make.
Supply Installation Testing Commissioning of Cable manager complete as per specification up to the entire satisfaction of Engineer-in-Charge of the work AMP/Panduit Schneider make.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .