Executive Engineer ED-II Jammu
Office of the Executive Engineer ED-II Jammu
SITC of 11KV line on 9Mtr PCC Poles with 50mmsq HT ABCable, SITC of Isolation Points, SITC of 11KV CTPT Unit and improvement of existing 400KVA Distribution substation on Turnkey Basis for providing dedicated power to Sub-Distt. Hospital Bishnah
2021_PDD_144736_1
E-Nit No. 52B of 2021-22 dated 21-10-2021
Open Tender
Electrical Works
Turn-key
60 days
Jurisdiction of Electric Sub-Division Bishnah
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer ED-II Jammu
₹39,700
22 Dec 2021
22 Oct 2021
12 Nov 2021
22 Oct 2021
11 Nov 2021
22 Oct 2021
22 Oct 2021 - 11 Nov 2021
Amount
Particulars of works for Laying of 1.25Km 11KV line on existing Poles with 50mm² ABCable
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. ( Insertion of Poles in Longer Span)
Supply ,Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc. (Required to be fixed on Insertion of Poles in Longer Span)
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, Transportation, Erection , Testing & Commissioning of 50 mm² AB (HT) Cable (3x50 + 1x70 mm²) on existing poles
Providing and Fixing of Heat Shrinkable Outdoor Cable Termination Kit
Providing and Fixing of Suspension/Tension Clamp with eye hook alongwith all Accessories including Galvinized Nuts and Bolts.
Providing and Fixing of Danger Plates
Providing and Fixing of Anti-Climbing Device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip 25x3mm.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing and Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Particulars of works for erection & commissioning of 2No Isolation point with 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply ,Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 50mm² ACSR Conductor
Supply, Installation, Testing & Commissioning of 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, line Type
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for PCC Poles & 1 No. For G O Switch/LA)
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Particulars of works for erection & commissioning of 2No Isolation point with 11 KV Isolator, Double Break, 3-pole, 400Amp, Horizontal Mounting Type, with Earth Switch
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply ,Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 50mm² ACSR Conductor
Supply, Installation, Testing & Commissioning of 11 KV Isolator, Double Break, 3-pole, 400Amp, Horizontal Mounting Type, with Earth Switch
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, line Type
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip (2 nos for PCC Poles & 1 No. For G O Switch/LA)
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Particulars of works for Supply erection testing & commissioning of 11 KV CT/PT Metering Unit ratio 30/5
Supply erection testing & commissioning of 11 KV CT/PT Unit ratio 30/5 including 3-Phase, 4 Wire Trivector Meter with Compatible Meter Box and PVC Copper Control Cable 10 Core of suitable Length (complete Unit) (Conforming ISI Standards) Including Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps as per site requirement etc. duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Improvement of 11/0.415KV 400 KVA Distribution Substation by way of replacement of damaged equipments
Providing and Painting of Substation MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc with two coats of red oxide & aluminium paint including all necessary Nut & Bolts & Washers etc.
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Providing & Fixing of Single Phase PVC Cable 400 mm² ,1.1K V Grade, PVC Insulated Stranded Armoured FRLS type alongwith Al. Thimbles for 400 mm² Cable termination with four colored PVC Tapings to distinguish the LT Phases and the Neutral. (2 Ckt)
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing & Fixing of Pole mounted LT Distribution Box for 400 KVA DTR with 1 No. Triple Pole MCCB of 630Amp with adjustable overload release (80-100%) for incomer & 2 Nos. 300Amp Triple Pole MCCB for Outgoing Circuits, Material of Busbar for Phases & Neutral-EC Grade Aluminium, PVC Insulated Sleeved Busbar of required load handling capacity with colour code for Phases and Neutral differentiation, including Aluminium thimbles of required sizes for proper termination etc.
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) with U-Clamp & Shackle Insulators (3Ph4W) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.( Insertion of Poles in Longer Span of LT line)
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Write back of old dismantled material to Divisional Store
INDUSTRIAL ELECTRICALS
SUNIL KUMAR SURI CONTRACTOR
ROYAL ENGINEERS AND CONTRACTORS
Technisys Engineering Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .