Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.3 L+₹37,653 (1.80%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.3 L+₹37,653.81 (1.80%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.6 L+₹2.7 L (12.7%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹23.6 L
EMD Value
₹43,000
Closing Date
30 Nov 2021, 5:00 pmClosed
XEN Electrical division No. 1 Shimla-9
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
Rewiring of existing old CHC Hospital building at Dadhau Distt Sirmour HP
2021_PWD_53846_1
Electrical Div.No1PWD Shimla 2021-22-6303-08 da
Open Tender
Electrical Works
Item Rate
90 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
E.E.Electrical Division No-I Shimla-9
₹43,000
22 May 2022
22 Nov 2021
1 Dec 2021
22 Nov 2021
30 Nov 2021
22 Nov 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. FRLS PVC insulated copper conducto single core cable etc. as required.
Group-C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and fixing suitable G.I. with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable G.I. with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of mm deep 12 module (200mm*150mm) on surface or in recess with suitable modular sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req. (For light plugs)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2x1.5 sq.mm + 1x1.5 sq.mm earth wire
2x2.5 sq.mm + 1x2.5 sq.mm earth wire
2x 4 sq.mm + 1x 4 sq.mm earth wire
2x10 sq.mm + 1x6 sq.mm earth wire
4x 2.5 sq.mm + 2x 2.5 sq.mm earth wire
4x 4 sq.mm + 2x 4 sq.mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3x1.5 Sq. mm
3x4.0 Sq. mm.
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required
Armoured cable 16 sq. mm (four core)
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 400 sq. mm (3.5 core)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
25 mm. dia
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Double pole. Cat-A.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Earthing with Copper earth plate 600mm*600mm*3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and erection of sheet metal Main cubical pedestal (confirming to(IEC code-61439) of dimensions 1600mm(H)*2650mm(W)*500mm(D) with plus 5cmm variation,M.S. CRC Sheet 16G duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements including 1 No. MCCB 500 Amp(4 pole), 1No. MCCB 400 Amp(4 pole) for Heating load , 1 No. MCCB 125 amp(4 pole) for light load, 1No. On load Changeover switch 125amp(4 pole) 4Nos. MCCB 32 amp(4 pole) Light load, 2 No. MCCB 63 amp(4 pole) Heating load, 2 No. MCCB 100 amp(4 pole) Heating load, , copper busbar strips 1No. 500 Amp, 1No. 400 Amp, 1No 200 Amp metering module & indicating lamp set.The cubical pedestal shall have cable entry box at one or two sides,with epoxy powder coated approved paint and bonding to the existing earth etc.The same shall be erected on base frame channel 75mm*40mm*3mm duly painted with siemen grey powder coated paint.
Supplying and erection of Heating sub - panel L.T. Panel (confirming to(IEC code-61439) of dimensions 650mm(H)*450mm(W)*200mm(D) with plus 5cm variation, made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 32 Amp MCCB , 32 Amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and erection of Heating sub - panel L.T. Panel (confirming to(IEC code-61439) of dimensions 650mm(H)*450mm(W)*200mm(D) with plus 5cm variation, made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 63 Amp MCCB ,63 Amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and erection of Heating sub - panel L.T. Panel (confirming to(IEC code-61439) of dimensions 700mm(H)*500mm(W)*200mm(D) with plus 5cm variation, made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements to house 100 amp MCCB , 100amp Copper busbar & 1 set RYB light indicator and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:-
25 Liter capacity water heater (Cat-A)
35 Liter capacity water heater (Cat-A)
Providing and installation exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
P/F openable sheet metal shutter suitable for exhaust fan size 300mm as required in all respect.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including, providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required: of Approved Make
Ceiling Fan 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Providing and installation of following type of surface mounting square/round type LED panel Light with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required:of Approved Make
Square/round LED Panel Light 10/12W Surface
Providing and installation of following type of LED batten with aluminium housing, anti glare polycarbonate diffuser and energy efficient constant current, integral electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including mounting clamps, connections, testing etc. as required: of Approved Make
LED Batten Light 20W
Providing and installation of following type of LED retrofit lamp B-22 holder base with polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. LED retrofit lamp 7 W Make: Philips,Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Providing and installation of following type of LED street light( cat no. BCLST 25W LED /V2) with powder coated pressure die cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP65 protection, electronic driver; suitable for input voltage: AC220-240V,50/60Hz, complete with all accessories, connections , testing and commissioning etc. as reqd. Make Philips, Bajaj, C&S, or any other approved by Engineer-in-Charge. LED 25 W
Supplying and erection of street light bracket made of G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required
32 mm dia. G.I. pipe, heavy class
Shyam Radio and Electrical
Haminder Pal
Sharma and Company
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_80600.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .