| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC FLAT NO 5 10 3 73 6 AMAR APARTMENTS TEACHERS COLONY EAST MARREDPALLY SECUNDERABAD 500026 | SECUNDERABAD | HYDERABAD | TELANGANA | 500026 | ₹2.8 Cr Quoted ₹2.9 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹3.0 Cr+₹12.1 L (4.23%)Rejected-AOC | ₹3.0 Cr+₹12.1 L (4.23%) | L2 | Rejected-AOC NOT BEING L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical DD NOT FOUND UPLOADED AS PER NIT |
| Sl No | Description | Qty | Unit | Dwarka Pershad Radhey Ramanlal L2 | B.N.S Constructions L1 |
|---|---|---|---|---|---|
| .50BOQ Dated 22 Jan 2026 | |||||
| .75GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XI are prepriced by MES under Ser No. 1 to 11. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | |||||
| 1.00 | Lumpsum price worked out by the contractor for “BUILDINGS OR WORKS” as listed in Schedule ‘A’ Part–I | 1 | Lumpsum | 2,25,95,700 ₹2,25,95,700 Lowest | 2,31,91,000 ₹2,31,91,000 |
| 2.00 | Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–II | 1 | Lumpsum | 87,389.15 ₹87,389.15 Lowest | 1,38,600 ₹1,38,600 |
| 3.00 | Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part–III | 1 | Lumpsum | 6,83,590.95 ₹6,83,590.95 | 6,28,830 ₹6,28,830 Lowest |
| 4.00 | Lumpsum price worked out by the contractor for "ROAD/PATH/CULVERT" as listed in Schedule ‘A’ Part -IV . | 1 | Lumpsum | 22,67,553.8 ₹22,67,553.8 | 21,62,520 ₹21,62,520 Lowest |
| 5.00 | Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part – V. | 1 | Lumpsum | 12,13,740.18 ₹12,13,740.18 | 11,17,080 ₹11,17,080 Lowest |
| 6.00 | Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part – VI. | 1 | Lumpsum | 1,60,435.6 ₹1,60,435.6 | 1,18,710 ₹1,18,710 Lowest |
| 7.00 | Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – VII. | 1 | Lumpsum | 58,622.14 ₹58,622.14 | 55,170 ₹55,170 Lowest |
| 8.00 | Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part – VIII. | 1 | Lumpsum | 14,44,740.07 ₹14,44,740.07 | 1,28,340 ₹1,28,340 Lowest |
Tender Value
₹2.4 Cr
EMD Value
₹3.1 L
Closing Date
8 Dec 2025, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
DEMOLITION OF BUILDING NO T-20 AND RECONSTRUCTION OF DEFICIENT LIVING IN ACCN FOR SNCOs AT AFS BEGUMPET
2025_MES_738249_1
801691/AF/E8
Open Tender
Civil Works
Lump-sum
420 days
GE(AF) HAKIMPET
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE(AF) HAKIMPET
₹3.1 L
Yes
6 Apr 2026
3 Nov 2025
15 Dec 2025
3 Nov 2025
8 Dec 2025
1 Dec 2025
4 Nov 2025 - 14 Nov 2025
BOQ Dated Oct 2025
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XI are prepriced by MES under Ser No. 1 to 11. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS OR WORKS” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for "ROAD/PATH/CULVERT" as listed in Schedule ‘A’ Part -IV .
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part – V.
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part – VI.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part – VIII.
Lumpsum price worked out by the contractor for "WATER COOLER / DESERT COOLER" as listed in Schedule ‘A’ Part -IX.
Lumpsum price worked out by the contractor for “HOT WATER SUPPLY” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “DEMOLITION AND DISMANTLING (B/R & E/M)” as listed in Schedule ‘A’ Part – XI.
Sch 'A' Part - XII : Fittings / Fixtures & Misc items.
INTERNAL ELECTRIC SUPPLY Supply and fix LED batten Tubelight with integral LED driver, plastic batten of 20 watts capacity including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and as directed.
Supply and fix LED batten Tubelight with integral LED driver, plastic batten of 10 watts capacity including necessary electric connections 3 core 1 sqmm insulated copper wire from ceiling rose to tube light fitting complete all as specifed and as directed.
Supply and Fix Decorative, wall mounting, Decorative wall light, gold finish fixture with cognac hammered glass diffuser suitable for 9 W LED filament lamp E27 base including suitable lamp complete all as specifed and as directed.
Supply and fix 30 Watts LED new generation energy saving and environmental friendly long life LED building light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 complete all as specifed and as directed.
Supply and fix exhaust fan, AC, single phase, 240 V, 250 mm sweep, PVC body with louvers, including connected with 3 core 1.5 sq mm copper conductor cable from ceiling rose to exhaust fan all as specified and as directed
Material and labour for Earthing complete with galvanized iron earth plate electrode of size 600mmx600mm x 6mm thick buried directly under ground vertically to depth not less than 2.25 meter below ground level with top edge of plate at a depth not less than 1.5 m below ground level connected to and including GI wire 4mm dia and GI protection pipe 15mm dia and light grade connected to and including by means of bolts nuts check nuts and washers made of copper as shown plate no 3 of SSR part 1 to the extent applicable to this item including necessary excavation earth work , PCC 1;3;6 chamber RCC 1;2;4 cover 50mm tick with 6mm TMT bar 100mm center to center watering pipe medium grade 20mm boe funnel wire mesh etc. and testing on completion etc complete all as specified and as directed.
EXTERNAL WATER SUPPLY Construction of Valve chamber having inner dimension 600x600x600 mm suitable for gate valve upto 50mm with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for copping, rendering plaster in CM 1:4, 15mm thick including provision of MS sheet top cover 3mm thick with brazing of MS flat of Size 25mm x 4mm at edges and in diagonal and angle iron base frame of 40 x 40 x 5mm painting with two coat of synthetic enamel paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Material and labour for road cutting /Hard standing for taking up or laying of LT UG Cable upto a depth of 15cm, after laying of cable well ramming to the excavated soil including repair the excavated portion of the road as existing or by providing suitable mixture of PCC complete all as specified and as directed.
Supply, install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, out door cubical type floor mounted,CPRI approved, factory made,totally enclosed, double door at front & rear side inclusive of necessary locking arrangement, dust and vermin proof, IP-54, fabricated out of CRCA sheet not less than 3.00 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 40X40X5mm with cable chamber for incoming and outgoing connections with suitable glands and lugs comprising for the following accessories including necessary PCC foundation of minimum 0.35m height positioned and grouted with suitable nut, bolts, washers etc to the MC pedestal and connecting all incoming and out going cables all as specified and directed :-
(a) INCOMING:- MCCB 4 Pole,125 Amps, breaking capacity of 36 KA, (ATFM) - 1 No (b) OUTGOINGS:- (i) MCCB 4 Pole 63 Amps, breaking capacity of 27 KA, (ATFM) - 3 Nos ( 01 Standby) (c) 200 Amps aluminium busbar for phase and neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos (e) LED type Indication lamp 240 Volts Set of three - 1 Set
WATER COOLER Supply and fix Electronic voltage stabilizer, automatic operation, single phase, naturally air cooled indoor wall mounting type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and as directed by Engineer-in-charge.
DESERT COOLER Supply and fix desert cooler electric driven (single phase), 230 volts 50Hz having nominal air flow capacity of 4000 Cum per hour Plastic/PVC Body 55 ltrs water capacity with honey comb cooling pads with water level indicator, speed control, ON/OFF switch all as specified and directed. Make : Symphony / Bajaj/ Usha/Voltas
DEMOLITION AND DISMANTLING (E/M) Taking down unserviceable Main Switch, Distribution Boards, Plug & socket DBs along with MCBs of any description complete all as specified and as directed.
Taking down old, vintage and unserviceable Earthing with connected accessories including earth work complete all as specified and as directed.
Taking down old, vintage and unserviceable aluminium / copper submain wiring of any size complete all as specified and as directed.
Taking up carefully LT UG cable of size 25 Sq mm 4 core from the trench/ laid on surface by removing the terminals from connected switchgears for re-laying the same including necessay earth work complete all as specified and as directed.
Taking up carefully 50mm dia cast GI tubing pipes (including all fittings) from trench /laid on surface for relaying the same including necessary earth work complete all as specified and directed.
Taking down Old, rusted gate valve/Float valve of size 20 mm dia bore complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
801691Tender.pdf
Tender Documents • 1.55 MB
Archdrawings.pdf
Additional Documents • 1.55 MB
Strldrawings.pdf
Additional Documents • 2.24 MB
801691TD.pdf
Additional Documents • 13.57 MB
BOQ_826629.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .