Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.8 L+₹3.5 L (12.7%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹33.2 L+₹5.8 L (21.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
14 Mar 2020, 6:00 pmClosed
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Special Repairs to electrical fittings and wiring at certain SMQs and water supply Pipe Lines at AF Stn Jaisalmer
2020_MES_315972_2
8646/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AF Stn Jaisalmer
As per NIT
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹58,000
Yes
24 Mar 2020
18 Feb 2020
16 Mar 2020
18 Feb 2020
14 Mar 2020
2 Mar 2020
Amount
Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed single core, multistranded copper conductor FRLS cable 1100 Volt grade Conforming to IS 694 including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including 20mm dia PVC conduit with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including second class hard wood board closed recessed, fixed on wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover including cutting chases in walls by cutter and making good the surfaces in cement mortar 1:3 complete, all as specified & directed.
All as per serial item No. 2.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on same board.
All as per serial item No. 2.00 here-in-before but for one bell/buzzer point controlled by one bell push.
M&L for point wiring for 6 Pin, 15/16 Amp socket outlet contralled by one 15/16 Amp switch on Independent board with 4.00 Sqmm single core PVC insulated and unsheathed single core, multistranded copper conductor FRLS cable 1100 Volt grade Conforming to IS 694 including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including 20mm dia PVC conduit with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated & including second class hard wood board closed recessed, fixed on wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover including cutting chases in walls by cutter and making good the surfaces in cement mortar 1:3 complete, all as specified & directed.
Supply and fixing switch piano, flush type, single pole, one way, 5/6 Amp (ISI Marked), 230 Volts.
Supply and fixing switch piano, flush type, single pole, one way, 15 Amp, (ISI Marked), 230 Volts.
Supply and fixing bell push, flush type, single pole, 5 Amp, (ISI Marked) 230 Volts.
Supply and fixing socket outlet, 2 in 1, 3 pin, 5 Amp, flush type, (ISI Marked), 240 Volts.
Supply and fixing socket outlet, 2 in 1, 3 pin, 15 Amp, flush type, (ISI Marked), 240 Volts.
Supply and fixing switch piano, flush type, single pole, two way, 5/6 Amp (ISI Marked), 230 Volts.
Supply and fixing Bell Multi Music Type, AC, 230 Volts, single pole, (ISI Marked).
Supply and fixing stepped type electronic fan regulator, flush type and connecting up, ISI marked, 240 Volts including taking down unserviceable complete all as specified.
S&F ceiling rose surface bakelite 65mmx17.5mm with two or three terminal PVC/Polycarbonate, isolated body complete all as specified.
Supply and fixing 6 watt, IP-43 LED bulk head fitting in engineering plastic housing with clear prismatic diffuser and LED 6 watt with all accessories with 3 core flexible cable white of size 23/0.0076 including taking down old unserviceable bulk head complete all as specified and directed. Make : C&S Cat Part No CG80IB6WLED or equivalent in Syska/Philips/Bajaj.
M&L for Sub main wiring with 6.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 6.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour drawn through in existing surface/recessed steel/PVC/steel rigid conduit including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor shall be measured & paid as one unit.
M&L for Sub main wiring with 4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor FRLS 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
S&F MCB, 6 to 32 Amp, Single Pole, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, fixed in repairs. Make : Legrand /Schneider/Siemens/C&S
S&F MCB, 40 to 63 Amp, Single Pole Neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, fixed in repairs. Make : Legrand /Schneider/Siemens/C&S
S&F MCB, 40 to 63 Amp, Triple Pole, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, fixed in repairs. Make : Legrand /Schneider/Siemens/C&S
S&F MCB, 40 to 63 Amp, TPN, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, fixed in repairs. Make : Legrand /Schneider/Siemens/C&S
Supply and fixing LED decorative box type light fitting 20 watt Cat Part No DMLN1LT8-16 Make : Crompton Greaves or equivalent in Bajaj/Philips with LED Tube rod 20 watt Cat Part No. LTT8-20 of make - Crompton Greaves or equivalent in Bajaj/Philips along with all accessories, pre-wired fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-charge.
S&F lamp holder angular type with 9 watt LED bulb, PVC/Polycarbonate type with back plate suitable for batten fiitng including taking down unserviceable lamp holder.
Supply & fixing Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link including taking down old unserviceable Distribution board any type complete all as specified and directed. Make Standard Cat Part No DSDMSHMSIW06000 equivalent in Legrand/ Indoasian/ Siemens/ Schneider.
Supply & fixing thermostate suitable for 25/35/50 litre geyser complate all as specified and directed by Engineer-In-Charge
Supply & fixing element for 25/35/50 litre geyser complete all as speicifed and directed by Engineer-In-Charge
Supply & fixing 300mm heavy duty exhaust fan with 900 RPM including making holes in to the wall as per fan size and making good the disturved surfaces all as directed by Engineer-In-Charge
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, install, testing and commissioning of LT panel size 800 mm x 600 mm x 150 mm enclosures cubical weather and vermin proof totally enclosed made out of 1.6 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50 Hz double door with front openable and PVC acrulic glass cover suitable size for checking of meter reading without opening door with locking arrangement incl inner shutters for mounting switch gear etc, suitable arrangement for fixing of electrical meter and SPN 40 to 63 Amp including pre wiring from Bus bar to Meter and Meter to MCB SPN (for pre wiring use 6.00 Sqmm Single core copper cable and suitable size of lugs for connecting from Busbar to meter and meter to MCB SPN) including bottom gland plate with sufficient numbers of circular cable entry holes, including prewired complete as per drawing with masonary work for fixing in wall duly powder coated with comprising of the following :-
INCOMING (i) MCCB 63 Amps FP, 415 Volt 25 KA adjustable thermal & fixed magnetic setting Ics = 100% = 01 No of Make : Havells/C&S electric/ Legrand/Siemens. (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos (iv) Aluminium bus bar 200 Amps capacity with bus bar supports, DMC/SMC insulators of CPRI approved of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos. OUT GOING (i) MCB 32 Amp,415 Volt,10 KA, Single pole and neutral -04 No Make : Legrand/Siemens/Schnedier (ii) S&F single phase electronic energy meter with LCD display of rating 5-30 Amp class 1.0, 240V 50 Hz counter type display with transparent hinge including connection from SPN to meter with 6 Sqmm copper stranded conductor including earth wire complete all as specified and directed by Engr-in-Charge. Make : HPL Cat Part No SPPC131000000C00 or equivalent in Neptune - 04 Nos
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified.
Returning, filling in including in spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified
Supplying, laying jointing, commissioning & testing DI pipes with rubber gasket Tyton Joints of spigot and socket ends centrifugally cast (spun) class "K-7" conforming to IS-8329 -2000 in any length of size 200mm bore laid in trenches ncluding taking up or down old unserviceable CI/DI water tubing and connections of 200mm bore complete all as specified and directed.
Supplying, laying jointing, commissioning & testing DI pipes with rubber gasket Tyton Joints of spigot and socket ends centrifugally cast (spun) class "K-7" conforming to IS-8329 -2000 in any length of size 150mm bore laid in trenches ncluding taking up or down old unserviceable CI/DI water tubing and connections of 150mm bore complete all as specified and directed.
Supply and Fixing CI/DI fitting upto 200mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, staright, bend, increasing, decreasing or double socket extra Tee pieces single branch Ý'Junction, double branch, cross collars caps etc complete all as specified and as directed.
Making connection by cutting existing CI/DI main 300 mm dia bore under ground pipe including inserting tee 300mm x 300mm x 200 mm bore and CI collar including necessary earth work jointing and jointing materials complete all as specified and directed. Note - CI/DI pipe fittings shall be measured and paid seperately.
Supply and Fixing CI Sluice valve flanged of class PN-1.6, 200mm dia ISI marked conforming to IS-14846-2000 complete with stainless steel spindle flanged both ends drilled CI gate with brass ring and iron wheel handle suitable for CI/DI pipe line including rubber of gasket, nuts, bolts & washer including taking down old unserviceable sluice valve complete all as specified. (Note : Joints shall be measured and paid seperately)
Supply and Fixing cast iron Air valve with single air outlet, 80mm dia ISI marked conforming to IS-14845-2000 heavy duty, complete all as specified and as directed.
M&L for Constraction of brick masonary valves pit of size 1500mmx1500mmx150cm (internal dimention of chamber) made with sub class 'B' old size bricks, compressive strength not less than 75 Kg/sqcm bulit in cement mortar 1.6 for sluice valve chamber including necessary excavation, foundation concrete in PCC 1:3:6 type C1 using 20 mm graded stone aggregate and 15mm thick inside cement plaster with cement mortar 1:4 with floating coat of near cement, PCC coping type B1 (1:2:4) using 20mm graded stone aggregate with MS frame with angle iron 40x40x6 mm and cover of MS sheet 3.15mm thick including tarring and painting (where required ) the steel surface with two coats of synthetic enamel paint over a coat of red oxide prime complete as specified and locking arrangement directed by engineer-in-Charge.
M/s Shree Construction Company
MAHAVIR CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .