Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.2 CrAccepted-AOC SP 52 MPPGCL COLONY BIRSINGHPUR DISTT UMARIA 484 552 M P | BIRSINGHPUR | UMARIA | MADHYA PRADESH | 484552 | ₹1.2 Cr | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹1.3 Cr+₹8.9 L (7.19%)Rejected-AOC | ₹1.3 Cr+₹8.9 L (7.19%) | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹1.3 Cr+₹9.6 L (7.77%)Rejected-Finance PLOT NO 41 SECTOR D BAGRODA INDUSTRIAL AREA BHOPAL MP 462026 | BHOPAL | MADHYA PRADESH | 462026 | ₹1.3 Cr+₹9.6 L (7.77%) | L-3 | Rejected-Finance L-3 |
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
2 Mar 2019, 3:00 pmClosed
SE PNW
O/o CE Gen Sarni
AOH of Fans,Duct dampers and Air Preheater of Unit No.6,7,8 and 9 STPS,Sarni.
2018_MPPGC_90_1
WT2474STPS
Open Tender
Miscellaneous Works
Item Rate
25 days
Sarni
As per NIT
4 documents required · 4 mandatory
₹5,000
Yes
Payable To
₹2.5 L
Yes
12 Mar 2022
22 Jan 2019
6 Mar 2019
22 Jan 2019
2 Mar 2019
23 Jan 2019
ROTARY MACHINE
I.D.FAN :-
Servicing of lub. oil system including cooling water line & valves.
Servicing /Replacement of I.G.V. system.
Replacement of fixed vane.
Replacement of set of fan Brgs.
Replacement of set of fan brg. & impeller.
Replacement of shaft, impeller & set of fan bearing with impeller housing
Checking & servicing of set of fan brgs.
Replacement of impeller.
Servicing/Replacement of motor brg.
Repairing of shaft protecting pipe, outer brg. Air pipe, diffuser body & impeller housing of ID fans.
Replacement of Diffuser Duct.
F.D.FAN :-
Servicing of lub. oil system including cooling water line valves.
Replacement of set of fan bearings.
Checking & Servicing of set of fan brgs.
Servicing / Replacement of servo motor
Servicing og IGV System of Unit No. 6
Servicing of blade bearing assy.
Replacement of set of Blades of blade brg.assly
Complete alignment of motor and fan alongwith coupling.
Replacement of Impeller of Unit No. 6
Repl. Of eroded/corroded colling water lines of fans size 50mm to 100mm Nb.
Servicing / Repairing of following fans seal air fans/ Ignitor air fans/ scanner air fan (AC/DC) Gun colling fans/ swirl air fan
P.A.FAN :-
Servicing of fan lub. oil system & motor lub. Oil system including cooling water line v/v.
Servicing/Replacement of I.G.V. system.
Replacement of set of fan brgs.alongwith Impeller
Checking & servicing of set of fan brgs.
Replacement of impeller.
Servicing/Replacement of motor bearings.
Complete alignment of motor & fan alongwith coupling
Replacement/ Realignment of Bearing housing
DUCT & DAMPERS:-
EXPANSION JOINTS(E.J.)
Repairing E/J small sized upto 3000 mm.
Fabrication & Replacement of existing expn. Joints small sized upto 3000mm.
Repairing of E/J Big sized above 3000mm up to 5000 mm.
Fabrication & Replacement of E/J Big sized above 3000mm upto 5000mm.
Repairing of E/J Big sized above 5000mm upto 8000mm.
Fabrication & Replacement of E/J Big sized above 5000mm upto 8000mm.
Repairing of E/J of wind box size 5000 to 8000mm
Replacement of E/J size above 5000 mm.
Servicing of damprs & gates:-
Hot air gates of mills.
Cold air gates of mills.
Hot air dampers of mills.
Cold air dampers of mills.
ID,FD & PA fan inlet and outlet dampers.
Servicing of PA discharge Gillotin gates.
Replacement of old/damaged/ eroded platess of SA/PA/ Fluegas ducts, wind box and other areas of Blr.
Repairing of SA/PA/ Fluegas duct, Eco.and Air heater hoppers by running welding.
Replacement of Eroded plates of Eco. & Air heater hopper .
Cutting & Replacement of supporting channel/ angles of Economiser hoppers/ Air heater hoppers and ducts etc.
Replacement/ repairing of Flushing apparatus & discharge pipes of Economiser hoppers and Air heater hoppers
Servicing of Ammonia dozing system.
INSULATION & G.I.SHEETING
Removal & reapplication of G.I.sheets & insulation on expansion joints , ESP,DUCT,AIR heater zone etc.
Only sheeting works over insulation of expansion joints , ducts, Air heater zone & ESP.
REGENERATIVE AIR PRE-HEATER :-
Servicing & repairing of complete air heater A&B of boiler including soot blower assly.
Reversal / replacement of Hot & Intermediate End Heating Elements
Removal of cold End element & refitting /replacement after cleaning.
Checking & servicing of support brgs.
Changing of existing guide brg. by new brg.
Checking & Servicing of guide brgs.
Replacement of pin rack pin.
Servicing/Replacement of 5 APC gear box.
Replacement of worn out plates of centre section by 10/12/16 mm plate.
High pressure jet cleaning of Hot/Intermediate/Cold end hating element (more than 100Kg/cm2 pressure)
Servicing & Repairing of louver dampers of Flue gas duct
Servicing & Repairing of APH PA side suction & discharge .damper
Servicing & Repairing of APH SA side suction & discharge damper.
Running meter welding in flue gas inlet duct of A/H and center section
Repairing of flue gas duct(between air heater top to flue gas inlet to A/H dampers) with 6mm / 8 mm, APH housing & connecting plates.
Complete Alignment of Fan (ID/FD/PA)alongwith Motor
ABZAN CONSTRUCTION PRIVATE LIMITED
UNITED ENGINEERING
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .