Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L1 | Accepted-AOC DUE TO BEING LOWEST (L1) AND REASONABLE | |
| 2 | L2₹23.8 L+₹36,789.76 (1.57%)Rejected-Finance ALIPURDUAR | ALIPURDUAR | WEST BENGAL | 735204 | L2 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 3 | L3₹25.5 L+₹2.1 L (8.97%)Rejected-Finance | L3 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 4 | L4₹32.4 L+₹9.0 L (38.6%)Rejected-Finance PATOLI BRAHMANA WARD NO 02 PO MUTHI TEH DISTT JAMMU J K PIN 181205 | JAMMU | JAMMU AND KASHMIR | 181205 | L4 | Rejected-Finance FOUND OTHER THAN LOWEST | |
| 5 | Kameshwar builders and contractors L5₹45.8 L+₹22.4 L (95.8%)Rejected-Finance | L5 | Rejected-Finance FOUND OTHER THAN LOWEST |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
18 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE, GE (SOUTH) AKHNOOR
GE (South) Akhnoor PIN- 900234 c/o 56 APO
SPL REP TO BLDG NO P-28 (1 TO 08 ) (OR MD ACCN) AT KS VIHAR UNDER GE (S) AKHNOOR
2025_MES_701571_1
GES/AKH-69/2024-25
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹68,000
23 Jun 2025
20 Mar 2025
21 Apr 2025
20 Mar 2025
18 Apr 2025
4 Apr 2025
Amount
Demolition of cement concrete (unreinforced) concrete in ground floors and paving n-exc 15cm thickness ( below or above ground floors.) , complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in plinth protection,joints filled with bitumen sand mixed 50mm thick, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for plain cement concrete type B-1,1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring etc, complete all as specified and directed.
Roughening of old concrete surfaces of floor including picking, sweeping cleaning and washing down with water to remove dust, etc and laying screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement 1:6, complete all as specified and directed.
M&L for non-skid ceramic coloured designer pattern tiles 300x300mmx7mm thick in floors etcset jointed in neat cement slurry and pointed in white cement or coloured cement to match etc, complete all as specified and directed.
S&F non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and directed.
S&F non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, on vertical surface such as skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 as for tiles screed bed , complete all as specified and directed.
M&L for glazed ceramic coloured designer pattern tiles 450mmx 300mmx7mm thick on vertical surface such as skirt, dado etc. set and jointed in white colour cement, complete all as specified and directed.
M&L for granite 20mm thick(table rubbed and polished) in cooking platform and like in cement mortar 1:4 including pointing in white cement(1:2) using marble dust making holes in RCC shelves suitable for gas pipe with round edges where required complete all as directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over 20 mm thick cement mortar 1:6 screed bed laid and jointing with grey cement slurry mixed with pigment including rubbing and polishing complete with machine all as specified as on stair shelves etc complete all as specified and as directed by engineer in charge.
M&L for machine cut kota stone 18-20mm thick in skirting/dado etc laid over 10 mm thick cement mortar 1:4 as back coat and jointing with grey cement slurry mixed with pigment including rubbing and polishing complete all as specified as in directed by Engineer in Charge.
Demolition for cement concrete exc 15cm thickness but above ground floor as in sunken floor , complete all as specified and as directed .
M&L for 15mm thick rendering in 1:3 cement mortar with using 3% WPC as in sunken portion (cost of WPC included in this item)
M&L for applying evenly a tack coat of industrial bituminous 85/25 @ 1.20 Kg per square mtr including cleaning surfaces, complete all as specified and as directed.
M&L plain cement concrete type B-1, 1:2:4 using 20mm graded crushed stone aggregate 25mm thick as in flooring with using 3% WPC etc. (cost of WPC included in this item) ,complete all as specified and as directed.
M&L plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as filling under floors(sunken slab) , complete all as specified and as directed.
M&L for 40mm thick plain cement concrete type B-0 1:2:4 using 12.50mm graded crushed stone aggregate as in floor etc complete mixed with WPC @ 3% by weight of cement (cost of WPC included in this item) laid finished even and rough to receive plaster without using extra cement complete all as specified and as directed.
M&L for plain cement concrete1:2:4 type B-1 using 20mm graded crushed stone aggregates as sides of rounded or chamfered on edges of sunken floor complete all as specified and directed.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 , complete all as specified and as directed.
S&F 32mm bore G I pipe beveled cut at both ends by making hole in walls sunken portion approx above the RCC slab and ceiling finished the hole with cement plaster 1:2 to match with existing surfaces complete etc., complete all as specified and as directed.
M&L for repairing RCC projection chajjas, roof, facia etc. by necessary preparation, scraping, cutting, chiseling derusting and cleaning exposed reinforcement surfaces of damaged, loose RCC surfaces with cement concrete 1:1.5:3 using 12.5mm graded crushed stone aggregates and reinforcement with welded mesh of weight exc 2Kg per Sqm but n.exc 3Kg/Sqm (if required) with or without facia and finished with cement mortar 1:3 using coarse sand and work in patches area n.exc 5 Sqm and thickness RCC member n.exc 70mm incl necessary formwork and applying two coats of finishes to match with the existing surfaces at any height complete. (note: welded mesh to be paid separately)
Dismantling brick tiles or terracing tiles single layer on roofs, complete all as directed by the Engineer-in -charge.
Taking down of existing roof treatment from roof and terrance roughening surface of old concrete roof by picking sweeping clean and washing down with water to remove dust etc and applying roof treatment with the following specification (a) Applying cement slurry over concrete surfaces @ 3Kg/Sqm (b) Rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound as per manfacture's instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof (leveling course) (c) Applying evenly one coat of cold bituminous primer conferming to IS 3384-1986 @ 0.40 Kg per Sqm on the cleaned plastered surfaces (d) Applying evenly one coat of blown hot bituminof grade 85/25 @1.2Kg per Sqm primed surfaces (e) Applying a layer of APP base polymerie membrane, 3mm thick (minimum) weighing 3.00 Kg per Sqm reinforces) with polyster non woven fabric wighing not les than 160 gms per Aqm by torch application. The overlap shall be not less than 100mm on transverse direction and 75 mm on longitudinal direction and sealing oversaps,complete all as specified and as directed.
M&L for providing 20mm thick pre-cast plain cement concrete tiles jointed & pointed flush in cement mortar 1:6 over 15mm thick bedding layer of cement mortar 1:6 using 5% creosote oil ,complete all as specified and as directed.
S&F for tube 'medium grade' galvanized, with all fitting and fixed complete to walls and ceiling etc 15mm bore,including taking down or up steel tubing and connections and removal to store complete all as specified and directed.
S&F for tube 'medium grade' galvanized, with all fitting and fixed complete to walls and ceiling etc 20mm bore,including taking down or up steel tubing and connections and removal to store complete all as specified and directed.
Cutting chases in brick wall for concelled water tubing exc 10 cm but not exc 20 cm girth and making good.
S&F bib taps chromium plated fancy type, cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed in repair 15mm bore , complete all as specified and directed.
Supply& fixing in repair wall mixer with provision of shower for mixing hot and cold water 3 in 1 fancy type brass chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed 15mm bore fixed.
Supply& fixing in repair stop cock fancy type chromium plated with cast copper alloy screwed down high pressure with or without lathered hot and cold with long screwed shanks and fly nuts fixed in repair 15mm bore, complete all as specified and directed.
Supply & fixing in repair wall mixer as in sink mixer 2 in 1 , cast copper alloy, with capstan head chromium plated screwed down high pressure with or without lathered hot or cold with long screwed shanks and fly nuts screwed for iron pipe 15mm bore, complete all as specified and directed.
Supply & fixing in repair PVC connection 15mm bore size with PTMT nuts of length 45cement mortar, complete all as specified and directed.
S&F as in repair PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets. 10 ltr capacity, complete all as specified and directed.
S&F for fancy brass chromium plated shower rose 125mm fixed in repair, complete all as specified and directed.
S&F in repair for stainless steel with draining board made of 1.00mm thick sheet for kitchen with plug , washer waste pipe cast iron cantilever bracket connecting union overall size 915mmx 460mm with bowl size 330mm x160mm., complete all as specified and directed.
S&F in repair CP grating ISI marked 150mm dia with centre hole , complete all as specified and directed.
S&F in repair for stainless steel plate rack of superior quality size 36" x 30" with not less than 8 kg , complete all as specified and directed.
Disconnecting existing tanks, capacity exceeding 250 liters but not exceeding 500 liters setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (cleaning repairing, etc. measured separately), complete all as specified and directed .
S&F rotational moulded polythene water storage tanks(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I 500 ltr capacity incl dismantling water tanks and removing to store , complete all as specified and directed.
S&F ball valve high pressure of PTMT with epoxy coated Aluminum rod & high density plastic ball screwed for iron pipe or brass ferrule and fixed in repair 20mm bore, complete all as specified and directed.
S&F for Gun-metal, globe or gate valves, for bore dia of pipe 15mm with iron wheel head, screwed both ends for iron pipe and fixed in repair complete all as specified and as directed.
Supply and fixing in repair vitreous China squatting pattern Orissa pattern WC size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) but excluding lime concrete bedding complete all as specified and as directed.
S&F in repair brass chromium plated tubular towel rail 20mm dia(D) type 60cm long between flanges complete.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each, complete all as specified and directed.
Taking down chowkhat or frame with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but n.exc 4 Sqm each , complete all as specified and directed.
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 125x60mm, complete all as specified and as directed .
Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., size of frame 105x60mm, complete all as specified and as directed.
Plain cement concrete M-10(1:3:6), type C-0, (using 12.50mm graded crushed stone aggregate), nominal mix, as in cills, steps; plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates and in hold fasts or filling in hollow of steel frame, including necessary form work, complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rein forced with M.S. square tube supplying and fixing in opening as per specification and drawing.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat molded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded etc. with suitable PVC sheet beading including hinges etc complete all as specified.
S&F factory made steel window, box type, using ERW hollow 'P' section, comprising double frame for and including gauged and glazed skeleton shutter, jointed internally with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD-1304, sheet No- 1/3 to 3/3 and as directed.
S&F sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 Sqm Each pane 3mm thick, complete all as specified and directed.
S&F figured glass pin head type glazed with oil putty in square n-exc 0.5 Sqm in Each pane 4mm thick, complete all as specified and directed. .
S&F factory made, 35 mm thick plain framed panelled shutter (two panel) of second class hard wood rail and style with lock rail and panel of 9 mm BWP commercial ply. The size of rail and style as per IS : 1003 Part I, klin seasoned and chemically pressure treated, all as specified and directed.
S&F glazed and skelton shutters using 2nd class hard wood 35mm thick open rebated and prepare to receive glass or gauge etc edges of framing plain and chamfered or fitted cut or mitered beads for securing glass size of member of shutter as specified in SSR Part-I section 8, clause 8.23(a) and divided in square complete all as specified.
S&F glavanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvnaised wire staples, complete all as specified and directed.
M&L for mild steel work as in desert cooler stand ornamental sections, rails fastining and heavy brecket framing( beam, tee, angle, chennel or flat section etc confirming quality -A Fe 410 Gde 250.
Supply and fixing of cupboard shutter 20mm thick (style) factory made pannel PVC including chowkat frame made out of m.s tubes 19 gauge for top and bottom rails m.s frame shall be covered with heated moulded plain colour PVC © channel having a PVC sheet strip of 10mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail and bottom rail on either side 10mm (5mmx2) thick of 20mm and 20mm cross PVC sheet and as gap insert for top and bottom rail. Pannelling for plain colour PVC sheet to be fitted in the m.s frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement supplying fixing in the frame at site as per specification and drawing as in repairs.
M&L for 2nd class hard wood plain fillets,square, rectangular or triangular in section,clean sawn,secured with nails or brads (sectional area exc 13 sq.cm & n exc 25 sq.cm)as in frame work for kitchen shelves.complete all as specified and directed
Supply and fixing as in repairs 18/19 mm thick Prelaminated particle board, interior grade, Prelaminated one side decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work complete all as specified and as directed.
S&F 40mm dia,cupboard knobs fixed with nut, screw and washer of mild steel,bright finished
S&F ISI marked Continuous (piano) hinges, mild steel,bright finish or electrogalvanised width of flaps (when open) in 30mm
S&F for external teak wood lipping, 6mm thick fixed with nails over block board or veneered particle board for
Preparation of new or previously untreated wood or wooden surfaces of any description, over 10cement mortar in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cement mortar width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and as directed .
S&F aluminium anodised barrel tower bolt ISI marked of extruded section and fixed, length of bolt 150mm, complete all as specified and directed.
S & F Aluminum alloy, anodized sliding door bolt ISI marked with hasp staple( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolt of extruded section or cast aluminium alloy 250 mm long , complete all as specified and directed.
S&F extruded aluminum alloy handles 150mm ISI marked size fabricated type anodized all as specified.
S&F 300mm ordinary rat rail rod ISI marked, pattern spring including roller plate complete fixing mild steel spring, complete all as specified and directed.
S&F hasp and staple saftey type aluminium anodised with mild steel hinges pin including bolt to hing plate ISI marked and fixed with screw size 100mm, complete all as specified and directed.
S&F floor doors stoppers of aluminium alloy body and tenque anodised ISI marked with hard drawn steel spring fixed in floor 150mm long, complete all as specified and directed.
S & F butt hinges,ISI marked, medium weight cold rolled mild steel 100mm long to PVC Door etc, complete all as specified and directed.
S&F epoxy powder coated rods of mild steel 20 mm with fixing brackets ,pelmet rods including pair of fancy type finnals complete fixed as in repair, all as specified and directed.
Demolition of brick work built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks old size straight or curved in plane exc 6cm mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth without using extra cement in cement mortar 1:6, complete all as specified and directed.
M&L 5mm thick plastering on fair faces for concrete surfaces finished even and smooth without using extra cement in cement mortar 1:3 on ceiling , complete all as specified and directed.
M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth without using extra cement in cement mortar1:4, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.(Note: Cost of water proofing compound shall be included in item).
M&L for preparation of new surface of wall with 3mm thick Birla putty on plastering surface and applying two coat of oil emulsion white or coloured over a coat of primer of chalk whitening or priming of OBD on walls complete all as specified and as directed.
M&L for preparation of new surfaces of walls and applying two coats of exterior emulsion (Apex paint) complete over one coat of primer complete all as specified and as directed
M&L for complete removal of existing treatment and preparation of old surfaces of walls and applying two coats of oil bound distemper over 3mm thick Birla putty complete all as specified and as directed by engineer - in- charge .
M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coat of white (lime) wash complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing of new plaster surface of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer in Charge.
Preparation of old/new decorated un- decorated, plastered or unplasterted surfaces of walls including complete removal of existing treatment and applying one coat of exterior emulsion (Apex paint) complete all as specified and as directed by Engineer - in- Charge
Dismantling of 100mm bore cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out from floors or walls complete , complete all as specified and directed.
Dismantling of 75mm bore cast iron or reinforced concrete drain pipes, jointed in cement motar and taking out of trenches , if required, complete all as specified and directed.
S&F for PVC (SWR) pipes110mm bore single socketed in any length with rubber ring joints fixed to walls ,complete all as specified and directed.
S&F for PVC (SWR) pipes75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors ,complete all as specified and directed.
S&F for PVC (SWR) pipes75mm bore single socketed in any length with rubber ring joints fixed to walls ,complete all as specified and directed.
S&F PVC (SWR) bends 110mm bore any radius ,complete all as specified and directed.
S&F PVC (SWR) bends 75mm bore any radius ,complete all as specified and directed.
S&F PVC (SWR) branch piece110mm bore, single (single Y) equal or unequal ,complete all as specified and directed.
S&F PVC (SWR) branch piece75mm bore, single (single Y) equal or unequal ,complete all as specified and directed.
S&F PVC (SWR) branch piece110mm bore, double (double Y) equal or unequal ,complete all as specified and directed.
S&F PVC (SWR) 110mm dia junction double, (double T), equal or unequal with access door ,complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore ,complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore ,complete all as specified and directed.
S&F PVC (SWR) 'P’ trap 110mm bore ,complete all as specified and directed.
S&F PVC (SWR) 'S’ trap 110mm bore ,complete all as specified and directed.
S&F 150 x 100 mm dia SW Gully trap setting and jointing with cement mortar 1:1 complete all as specified and directed .
M&L for plain cement concrete (1:3:6) type C-2(using 40 mm graded stone aggregate) as in bed to 150 mm bore internal pipe including packing under & haunching against the sides of pipes after they are laid tested complete all as specified & as directed.
Salt glazed stone ware drain pipes 150 mm internal bore grade 'A' laid in trenches ,jointed & tested including taking down existing pipe complete all as specified & as directed.
S&F in repair PVC110mm bore (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls ,complete all as specified and directed.
S & F PVC (SWR) bend 110 mm bore, complete all as specified and directed.
Demolition of Concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed.
M&L for pre-cast cement concrete 1:2:4 cover slab for manholes etc using 20mm graded stone aggregate. Set in cement 1:4, complete and including necessary formwork all as specified and directed.
Mild steel bars 10mm dia and over TMT bars cut to length bent to shape reqd including cranking ,bending spirally for hooping for columns hooking bends and binding with including mild steel wire (annealed) not-less than 0.9mm dia or securing with clips quality, complete all as specified and directed.
M&L for 75mm thick plain cement concrete1:4:8 type D-2( using 40mm graded crushed stone aggregate ) as in sub base flooring including form work, complete all as specified and directed.
M&L for chequered cement concrete tiles glossy finish coloured 40cmx40cmx25 mm thick pattern as approved by GE as in patches in floor set & jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over creed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell,socket or power, Sec light) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement for smooth finishing of holes,small patches etc complete all as specified and directed.
Taking down Exhaust fan, dismantling blades,deposite exhaust-fan to MES store yard and re-fixing only exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan including testing on completion complete all as specified and directed.
Taking down Ceiling Fan, ceiling cable end, dismantling blades and removing fan and blades and deposite to MES store and re-fixing the same including provision of cable from ceiling rose or connector to fan and connecting cable three core 0.75 Sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed by Engr in Charge.
Disconnecting, removing from the mounting carefully old Electric water heater of capacity 25/50 Ltrs including PVC Connection and handing over to AGE E/M store yard, refixing the same on the same position after completion of the wall repair works including connection, cleaning of out side surface of the Geyser, testing after completion complete. including making good the surface complete all as specified and directed.
Material and labour for point wiring complete with 1.5 Sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories are in concealed in walls /roofs/floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box,top cover, plate, blank plate,MS box,screws,washers and all modular electrical fixtures are to be used same make/brand only and modular box,top cover plate, MS box shall be measured and paid seperately under relevant items)
(a) One light point/fan point/ exhaust fan point/ bell point controlled by one switch.
(b) One 3 pin 5 amps socket point controlled by one 6 amps switch on independent board .
(c) One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
(d) One light point controlled by two 2 way switches.
Description all as per item No.122(b) above, but point wiring with 2.5 Sqmm and earth conductor of size 2.5 Sqmm complete all as specified and directed but for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board complete all as specified and directed by Engr in Charge.
Supply & fixing modular type switch 10 Amps, single pole,1way,1/2 module, 240V, ISI Marked complete all as specified and directed by Engr in Charge.
Supply & fixing modular type switch 10 Amps, 2way, single pole,1/2 module, 240V, ISI Marked complete all as specified and directed by Engr in Charge.
Supply & fixing Modular Bell push 6 Amp 1 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module, 240V, AC ISI Marked complete all as specified and directed by Engr in Charge.
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2/3 module with light indication ,240V,AC ISI Marked complete all as specified and directed by Engr in Charge.
Supply & fixing modular type switch 16 Amps, single pole,1way,1/2 module, 240V, ISI Marked complete all as specified and directed by Engr in Charge.
Supply & fixing modular White cover plate with frame, 2 module including metal flush box 2 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular White cover plate with frame, 3 module including metal flush box 3 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular White cover plate with frame, 4 module including metal flush box 4 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular White cover plate with frame, 6 module including metal flush box 6 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular White cover plate with frame, 8 module including metal flush box 8 module complete all as specified and directed by Engr in Charge.
Supply & fixing modular blank plate single module complete all as specified and directed by Engr in Charge.
Supply & fix fan regulator modular type electronic, stepped type(01 to 4/5), 100 to 120 Watts, 240Volts, AC, ISI marked complete all as specified and directed by Engr in Charge.
Supply & fixing Bell, AC, 230 volts, single pole multi music type complete all as specified and directed by Engr in Charge.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed by Engr in Charge.
Supply & fix angle lamp holder, polycarbonate insulated body with back plate for bulb complete all as specified and directed by Engr in Charge.
Supply and fix LED bulb 9 watts, 240Volts,50Hz pin type and including removing old unserviceable item complete all as specified and directed by Engr in Charge.
Supply and fixing in repair modular LED Indicator Lamp fixing on modular switch board 240V, AC, 50Hz suitable for 1/2 module ISI marked, including connecting with suitable length of 1.5Sqmm PVC insulated copper conductor complete all as specified and directed by Engr in Charge.
Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr in Charge.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
S& fixing in repair decorative wall light fixture Globe type including 9 W LED Lamp made up of polycarbonate complete all as specified and directed by Engr in Charge.
S & fixing in repair LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr in Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete including dismantling existing SPN MCB all as specified and directed by Engr in Charge.
Supply and fixing sheet metal enclosure DB TPN 4 way double door made powder coated out of CRCA mild steel sheet 200 amps rated bus bar dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to disturbed surface complete including dismantling existing DB all as specified and directed by Engr in Charge.
Supply and fixing sheet metal enclosures DB's double door factory made power coated out ofr CRCA mild steel sheet 1.6 mm thick with metallic painting white series, 240 volts 200 amps rated enamelled bus bar 8 way dust and vermin proof proof suitable for incorporation of MCBs duly concealed in walls and making good to disturbed surface and colour matching complete including dismantling existing DBsall as specified and directed by Engr in Charge.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series, AC, 240Volts, 50Hz , ISI marked complete all as specified and directed by Engr in Charge.
Supply & fix MCB SPN 6- 32 Amps 10 KA,"C" series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed by Engr in Charge.
Supply & fix MCB TPN 63 Amps 10 KA,"C" series, AC, 415Volts, 50Hz, ISI marked complete all as specified and directed by Engr in Charge.
M & L for sub main wiring complete with 2 run of 6 Sqmm single core copper conductor (ISI marked)cable 1100 volts grade, FRLSH type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including cutting chases and making good the surface, one run of 6 Sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and chasing and complete all as specified and directed by Engr in Charge including taking down existing wire. Note : - Two run of 6 Sqmm single core copper conductor cable and one run of 6 Sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Description all as per item ser No 153 here-in-before but 2 run of 4.0 single core and one un of 4.0 Sqmm single core as earth wire for geyser complete all as specified and directed by Engr in Charge.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, plain cement concrete earth pit chamber 1:3:6 type C1, of size 45X 45X 45 cement mortar, RCC cover 1:2:4 type B1 of size 45X45X6cement mortar, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old unserviceable earthing items complete all as specified and directed by Engr in Charge.
Supply and fixing in repair GI bracket pipe of size 40 mm dia medium grade of 1.0 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including suitable fabricate MS flat iron clamps of 25X6 mm thick -02 Nos suitable for fixing any places with nuts,bolts & washers including grouting on wall etc complete all as specified and directed by Engr in Charge.
Supply and fixing electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including dismantling existing meter any type complete all as specified and directed by Engr in Charge.
Supply, laying, connecting and testing for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 25 Sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc including taking down exixting cable any type and size all as specified and directed by Engr in Charge. (Excavation and earth work, sand cushioning ,brick protection & GI pipe shall be measured and paid for separately).
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exc. 1.5 mtr deep for laying of cables and getting out soft/loose soil complete all as specified and directed by Engr in Charge.
M & L filling dry and clean sand in trenches for cable 8 cement mortar deep below and 15 cement mortar above for cable cushioning complete all as specified and directed by Engr in Charge.
M & L for sub class 'B' brick of size 230x115x75mm laid flat work length equal to width of brick on sand for protection of under ground cable complete all as specified and directed by Engr in Charge.
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cement mortars thick in trenches complete all as specified and directed by Engr in Charge.
Removal of surplus soil obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr in Charge.
M & L for GI pipe 40 mm dia light grade fixing to wall or laying in floors for protection of cable complete including taking down existing pipe all as specified and directed by Engr in Charge.
M/s Shivam Construction Co (BID ID -3278474)
M/s Rajesh Kumar Contractor (BID ID -3280065)
M/S VERMA ENTERPRISES (BID ID -3283801)
Kameshwar builders and contractors (BID ID -3277762)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .