Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.8 L+₹1.7 L (9.56%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.2 L+₹3.2 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹19.4 L
EMD Value
₹39,000
Closing Date
5 Jul 2022, 6:00 pmClosed
GE (MIS) MHOW
Garrison Engineer (Maint) Inf School Mhow
REPAIR MAINT OF VARIOUS DISTRIBUTION PUMP HOUSES MAIN PUMP HOUSE FILTRATION PLANT BERICHHA PUMP HOUSE AND OH WATER SUPPLY INSTALLATION AND REPAIR MAINT OF STPS AND OTHER CONNECTED WORKS INSTALLED AT VARIOUS LOCATION OF AGE EM NO 01 UNDER GE MIS MHOW
2022_MES_529298_1
8495/GE (MIS)/MHOW
Open Tender
Miscellaneous Works
Item Rate
210 days
GE (MIS) MHOW
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹39,000
Yes
28 Jul 2022
7 Jun 2022
7 Jul 2022
7 Jun 2022
5 Jul 2022
21 Jun 2022
Amount
M&L for repairing and overhauling by dismantling / taking down all electrical and mechanical connection of Air blower including motor installed at STP and servicing hole body, change gear oil/ lubricant and V belt, overhauling, testing including painting of complete body and air outlets all as specified and as directed by Engineer-in-Charge. Note:- The following Spares and gear oil/ lubricants in adequate quantity for one Air Blower shall be provide by the contractor and the rate for the same shall deemed to be included in the quoted rate:- (a) Servo Gear oil Super 90 (b) Bearing for Air blower and motor as per sample (c) Oil Seal as per sample (d) Gasket Kit as per sample (e) Oil Seal As per Sample (f) V Belt as per sample (g) Air filter as per sample
M&L for dewatering the equalization tank by using mud pump and removing complete sludge and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder all as specified and directed by Engineer-in-Charge. Note :- (a) Making temporary arrangement for pumping out the raw sewage effluent from manhole near the equalization tank to a distance of approximately 100m from the STP during cleaning period of equalization tank and cost for the same is deemed to be included the quoted rate. (b) Contractor shall provide and ensure necessary safety precautions and to arrange safety mask, Hand Gloves etc during cleaning of tank. (c) Necessary arrangement shall be made by contractor for sludge pump to pump out the settled sludge in equalization tank to manhole.
M&L for dewatering by using Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 300 KLD installed at HD Enclave and removing all the settled solid sludge or any other type of material to a distance exceeding 100m from STP all as directed by Engineer-in-Charge.
M&L for dewatering by using Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 230 KLD installed at PW Div and removing all the settled solid sludge or any other type of material to a distance exceeding 100m from STP all as directed by Engineer-in-Charge.
M&L for dewatering by using Mud Pump and manning for cleaning of MBBR Tanks of compartments of STP of capacity 120 KLD installed at MH Mhow and removing all the settled solid sludge or any other type of material to a distance exceeding 100m from STP all as directed by Engineer-in-Charge.
M&L for dewatering by using Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 300 KLD installed at HD Enclave and removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder complete all as directed by Engineer-in-Charge
M&L for dewatering by using Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 230 KLD installed at PW Div and removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder complete all as directed by Engineer-in-Charge
M&L for dewatering by using Mud Pump and manning for cleaning of Tube settler Tank of STP of Capacity 120 KLD installed at MH Mhow and removing all the settled deposited Sludge/ fungus or other type of Bio fouling and cleaning inside, descaling internal surface of tank with wire brush and scraper, washing with fresh water two times with bleaching powder complete all as directed by Engineer-in-Charge
M&L for removing the dry sludge from the sludge drying bed, removing by using suitable covered type transport and dispose to a location as specified regularly during a period of operation or as and when ordered by Engineer - in- Charge.
M&L for testing of treated water sample, once in every three month by sending the water samples to the authorised laboratories for the following parameters:- (Note:-For 120 M3/Day & 230 M3/Day) a) PH : 5.5 to 9.0 (SPCB Limit) b) BOD: 10 mg/L Maximum (SPCB Limit) c) Turbidity : 5 NTU Maximum (SPCB Limit) d) Total Suspended solids : 30 mg/L Maximum (SPCB Limit) e) Residual chlorine: 1.0 mg/L Maximum (SPCB Limit) f) E. Coli: Nil CFU (SPCB Limit)
Supply only Bleaching powder grade -I ISI marked having stable available chlorine % by mass minimum 35% as per IS 1065,1971 and packed in 25 Kg bag complete all as specified and directed. Make : Vikram or other equivalent as approved by GE
Supply only Poly aluminium chloride in Powder form Gde-medium basicity for purification of water complete all as specified and directed. Make :- Vikram Pac or other equivalent as approved by GE
Supply only sodium Hypochlorite solution
M&L for dismantling the electric induction motor 415 volts AC 3 Phase, capacity 7.5 HP to10 HP, 440 V, 50 Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, ball bearing, bush, rewinding the motor after cleaning the rotor and stator with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing ball bearing, bush, all high grade material and class ‘B’ varnish for insulation & replacing the unserviceable nuts, bolts, washers of appropriate size and reassembling the complete motor and re-fixing, proper alignment, coupling with pump including connecting the existing electric cable connection, earthing, and testing the motor on full load up to entire satisfaction of Engineer-in-charge complete all as directed and as specified. Note :- (i) Super enameled copper winding wire shall be measured and paid separately under appropriate item as supply only. (ii) T & P/ vehicles for transporting pump to civil work shop & back shall be provided by the contractor and the cost deemed to be included in the quoted rates.
All as per srl item No. 14 here-in-before but electric motor of capacity upto 5 HP complete all as specified and as directed by Engineer-in-charge
Supply only Super enameled copper winding wire for rewinding the electric motors
M&L for MBBR media made out of poly propylene with virgin plastic, UV stabilised of specific gravity 0.95 to 0.98 complete all as specified
M&L for dismantling and taking down the complete pipe line of STP's for descaling including painting the outer surface of pipe and refixing the same and testing for leaks and replacing the complete nuts, bolts, washers and rubber gaskets etc complete all as specified and as directed.
M&L for replacement of carbon filter media and cleaning of ACF tank including taking out old media.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25m below normal ground level) connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25 mm x 4 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exec 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I, 2009 and all as directed and specified including take down old earthing completly.
M& L for repairing leakages of GI pipe line laid in trenches/ on floor/ fixed to wall etc. at MAP Md Accn (Building upto G+6 floor) including excavation on concrete floor/ ground/ Road, dewatering and removal of mud or pumping out water etc. and arrangement of staging for working on wall of building upto G+6 floor including by replacing of unserviceable GI fittings like elbow, union, socket, tees, nipple etc. of appropriate size and GI pipe upto 1.0m length all as specified and as directed by Engineer-in- Charge. Notes:- (a) Road, floor etc damaged during rectification of repairing shall be made good by using cement concrete to match with existing surface without any extra cost.
S&F in repair butterfly valves Lever operated having epoxy coated cast iron body PN 1.6 ISI Marked SGI disc with integral seat of nitrile rubber and including taking down of unserviceable valves for Pump Houses and distribution lines of MAP Accn of the following sizes:-Make:- Kirloskar/ Venus/ Leader/ Upadhyay or equivalent as approved by GE. Note:-Excavation, breaking of concrete , floor , ground etc if requried during alignment of pipe while replacing valve, shall be carried out by contractor and making good the damage surface as per existing and quoted rate shall be deemed to be inclusive for above provision.
80 mm bore
100 mm bore
150 mm bore
S&F in repair foot valve ball type foot valve with rubberized steel ball and CI body Flanged & screwed at the end of the suction line of size 100 mm bore including nut, bolts and rubber sheets, pipe cutting threading if necessary at MAP Accn Pump Houses all as specified and as directed by Engineer-in-Charge. (Make: NORMAX or other equivalent make as approved by GE).
S&F in repair Non Return Valve Swing type Horizontal Flanged and Screwed Ball type with rubberized steel ball and CI body Flanged & screwed at the end of the suction line of size 80 mm bore including nut, bolts and rubber sheets, pipe cutting threading if necessary at MAP Accn Pump Houses all as specified and as directed by Engineer-in-Charge. (Make: NORMAX or other equivalent make as approved by GE)
S&F in repair of single doom aviation obstruction lights of type LEADOL 2 with one no of 15 W LED Lamp on over head RCC Tanks all as specified and as directed by Engineer-in-Charge (Make:- Bajaj or other Equivalent as approved by GE)
S&F in repair PVC round sheathed copper conductor twin core flexible cable of size 1.5 Sqmm
Disconnecting the Centrifugal pumps of capacity 12.5 HP to 15 HP from motor and all water connections and removing/taking up from foundation, taking to civil authorised KIRLOSKAR dealer workshop or at site for repair/strip opening and repairing of pumping sets by changing the defective/unserviceable parts such as bearing, shaft, impeller, bush, Gland plate etc. complete, reassembling including oiling, greasing replacement of worn out nuts, bolts, gasket etc, and re-fixing in its original position at site, making all connections, commissioning and testing for smooth and noise free operation etc including rewinding the motor of capacity upto 15 HP using suitable size super enameled insulated copper wires, varnishing and replacing the worn out bushes bearing etc complete and reassembling including testing etc complete for satisfactory operation all as specified and as directed by Engineer-in-Charge. Note :- (i). Ball bearing, shaft sleeve, gland rope, lantern ring, impeller, Gasket Packing, copper winding and Nuts NYLOC etc shall be replaced if required and shall be measured and paid separately under appropriate item of this BOQ as supply only. (ii) T & P/vehicles shall be provided by the contractor and the cost deemed to be included in the quoted rates.
Supply only Shaft Sleeve Suitable for 12.5 to 15 HP Centrifugal Pump Set (Aas per sample)
Supply only Gland suitable for Centrifugal Pump Sets 12.5 to 15 HP (As per sample)
Supply only Lantern Ring suitable for Centrifugal Pump Sets 12.5 HP to 15 HP (As per sample)
Supply only cast iron Impeller suitable for 15 HP & 12.5 HP monoblock centrifugal pump set
Supply only Set of rubber packing & gasket flat shaft sleeve suitable for Centrifugal Pump Set 12.5 to 15 HP
Supply only Nuts NYLOC M 1116x2 RH of size suitable for 12.5 to 15 HP monoblock centrifugal pump sets
M&L for disconnecting existing incoming and out going cables from the Pump panels, after taking down power shut down if necessary and all existing safety precautions for human safety, cleaning dust from the panel, changing worn out aluminium/ copper lugs of suitable size, cables, proper insulating the cable and lugs with high class insulating tap with proper colour coding, including replacement of unserviceable MCCB, Isolator, volt meter, Amp Meter etc. where necessary and reconnecting and testing complete all as directed by Engineer-in-Charge. Note:- (a) All Nuts, bolts washer etc shall be replaced as per direction of Engineer - in- Charge. (b) MCCB, Volt Meter, Ammeter shall be measured and paid separately on appropriate items of BOQ.
Supply only MCCB 100 Amp, 4 pole, 415 volts 25 KA
Supply only Volt meter
Supply only Ammeter
M&L for Cleaning of Building top RCC Tank of capacity 50000 in 03 Parts (12500 litres capacity x 02 drinking and 25000 litres capacity x 01 Fire fighting) in MAP Accn at Ganesh Enclave at MCTE, Sarna enclave Near Signal Vihar, Goswami enclave at AB road and HD Enclave near Malcolm Line (inside) by scraping with the help of shovels, hard brushes and physical cleaning of building top tank by descaling / brooming slit and other deposit from inner side (bottom of the tank inside ) collecting and taking them out with the help of manual labour and depositing not exceeding 50m of the building all as directed and cleaning the tank first with water and then applying bleaching powder on the inner surface and cleaned completely by using wire, brush, broom etc and washed with water again and finally applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom of tank including writing date of cleaning with white paint on black painted surface two places and painting of inner steel ladder of tank with one coat of synethic enamel paint all as specified and directed by Engineer In Charge:- Note :- (a) Necessary T & P, ladder, Pump etc and all other material such as brush , brooms bleaching powder etc as requried for cleaning shall be provided by the contractor and ensure uninterrupted water supply to occupants . (b) All labour safety measure should be followed and ensured by the contractor while working on the building top Water Tank.
All as per item number 38.00 above, but for Under ground sump of capacity 0.5 to 0.85 Lakh gallon near pump houses at Ganesh Enclave at MCTE, Sarna enclave Near Signal Vihar, Goswami enclave at AB road and HD Enclave near Malcolm Line all as directed. Note :- (a) Necessary T & P, ladder, Pump etc and all other material such as brush , brooms bleaching powder etc as requried for cleaning shall be provided by the contractor and ensure uninterrupted water supply to occupants . (b) All labour safety measure should be followed and ensured by the contractor while working on UG sump.
S&F in repair Sluice valves cast iron body, double flanged, ISI marked (IS-14846), heavy duty, class PN-1.6 gun metal, with rising spindle of solid forged bronze and operating handle, including rubber gaskets, nuts, bolts, washers etc complete Make "Kirloskar/Leader/Zoloto/Upadhaya" complete of following sizes: -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking out sluice valves for refacing, regrinding and refixing of following sizes all as specified and directed by Engineer -in-Chargre :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fix Brass spindle externally threaded and fixed in repairs in sluice vales of following sizes:
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Supply and fix Brass Wedge nut with internal threaded and fixed in repairs in sluice vales of following sizes:
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying cables pipe etc. and getting out in hard / dense soil all as specified.
Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm all as specified.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
M&L for run lead joints for spigot & socket pipes and fittings for repairing the lead joints of following sizes:-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for burning out lead joint in position, including removing old lead of following sizes of CI pipe
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less 'than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron including 20 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type I, 50 mm thick precast RCC (1:2:4) type BI pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI wire of size 4 mm for extension of earth lead and necessary excavation, earth work, in any type of soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Ankit construction
NIDHI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .