Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹34.9 L+₹2.9 L (9.04%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹38.3 L+₹6.2 L (19.4%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹38.5 L+₹6.5 L (20.2%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹42.5 L+₹10.4 L (32.6%)Rejected-Finance | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
8 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (U) Meerut cantt
Roorkee road Meerut Cantt
REPAIR/REPLACEMENT OF LT CABLES, MCCBS INCL AND ALLIED WORKS IN NORTH AREA UNDER AGE E/M ELECT SUPPLY AT GE(U) E/M MEERUT CANTT
2024_MES_654786_1
8593/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut cantt
₹96,000
Yes
30 Sept 2024
18 May 2024
15 Jun 2024
18 May 2024
8 Jun 2024
1 Jun 2024
Amount
Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed by Engr-in Charge . Cables of the following sizes:-(Note;- Rate quotted includes terminal Lugs / road cutting/ wall cutting/ floor cutting and making good damged portion matching with existing surface with all existing finishes.)
6 Sqmm 3 core
16 Sqmm 4core
25Sqmm 4core
35 Sqmm 3.5 core
50 Sqmm 4 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Taking down old u/s LT UG Cable any core any size complete all as specified and directed
Taking down old u/s ACSR conductorany size complete all as specified and directed. (Note:- Some ACSR conductor shall be replaced with U/G cable as per site requirment)
Taking down mild steel cross arms etc complete all as specified and directed.
Taking out underground cable and relaying , jointing, testing and commissioning serviceable LT underground cables, 1100 volts grade any type and size complete all as specified and directed by Engr-in- Charge
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified and directed.
M & L for fly ash bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers ) pipes of the following sizes including taking out old u/s pipes.
50 mm bore
80 mm bore
100 mm bore
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Taking out unsv pole PCC/ Steel tubular and Supplying, transporting to site, erecting, and fixing in position, steel tubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with mild steel base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc, including painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 03 nos band /strips with fluorescent , PO box red synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, including the existing service line/ chanel/ street lights/JBs complete allied items shifting the new pole complete all as specified and directed by Engr-in-Charge.(Note:- Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted)
M&L for PCC (1:4:8)type D2 using 40 mm graded stone aggregate in foundation(below pole ) complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit) complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping / pedestal of poles including necessary form work, fair finishing to exposed surfaces using extra cement complete all as specified and directed.
Supply and fixing pre-fabricated MS structural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting the steel surfaces with two coats of synthetic enamal paint over one coat of primer complete all as specified and directed.
Material and labour for supply straining and stretching of aluminum conductor steel reinforced (ACSR), ISI marked, laid overhead on poles, including binding and jointing the conductor with and including 14 SWG binding wire complete all as specified and directed.
M&L for provision of anti-climbing device, spikes type, in two halves made to shape to suit the cross section of the pole, fabricated out of MS bars (round, square and flat) welded to MS flat including nuts, bolts, washers etc including taking out old anti-climbing device complete all as specified and directed.
Supply and fix in repair danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed with mild steel clamps (made of 25x3 mm MS flat iron) nuts, bolts and washers etc for LT poles / pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and directed.
Supply and fixing in replacement stay assembly for LT poles complete, comprising of galavanised steel stranded stay wire 7 / 3.15 mm, galvanished steel stay bow 400 x 14, galvanized steel rod 2150 mm long 16 mm dia with nut bolts and washers, steel plate 230 x 230 x 6mm thick , 2 nos thimbles , loop insulator size 65 x 90 mm clearance hole 16 mm including clamps and fixed to stay clamp complete all as specified. (Note : Rate quoted includes Excavation, earth work and PCC )
Supply and fix in replacement pin type insulator, porcelain, vitreous white, size 100mm height and 65mm dia, 1100 Volts grade, ISI marked, including one galvanised mild steel spindle, two Nos GI washers and one GI nut complete all as specified and directed.
Supply and fix in replacement shackle type insulator, ISI marked, porcelain, vitreous white, 1100 volts grade, ISI marked of size 90 x 75 mm, including galvanized mild steel strips 31x3 mm, washers, insulators bolts (12 mm dia), washers and nuts all as specified and directed.
M&L for plate earthing for sub station equipments complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically (in earth pit not less than 3.5 m below normal ground level) with the top edge of the earth plate at a depth not less than 2.75 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate excavation & earth work and RCC cover complete all specified and shown in electrical plate No 5 of SSR Pt-I. including taking out old u/s earthing material.
Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable for complete with jointing material ( heat shrink type) and accessories suitable for 25 sqmm to 50sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed.
Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable for complete with jointing material ( heat shrink type) and accessories suitable for 70 sqmm to 120sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed.
Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable for complete with jointing material ( heat shrink type) and accessories suitable for 150 sqmm to 185 sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed.
Supplying and fixing STRAIGHT THROUGH cable jointing Kit for 1100 V grade cable for complete with jointing material ( heat shrink type) and accessories suitable for 240 sqmm to 300 sqmm 3.5/4 core XLPE armoured aluminkium conductor cable and testing aftre jointing complete all as specified and directed.
M&L for Cutting of worn-out / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer/ Panel MCCB terminal/ FPB/ JB/ pole/DBs/ stud including cutting/ dressing of cable, disconnecting under ground / OH line cable conductor , cutting down worn-out portion and refixing with suitable lugs complete , including under ground cables of any type and size for repairs including taking out under ground cable loop from ground and making connections of restoration of electric supply complete all as specified.
Releasing the binding of ACSR conductor of OH lines from insulator , removing the jumper, connector, service wire, disconnecting the connection of UG cables and restretching of existing HT/LT OH lines , any size, length and span upto desired sag as designed by Engineer-in-Charge and rebinding the ACSR Conductor on insulator , reconnecting the UG cable etc complete all as specified. (Note :- Distance between two consecutive poles (any No of conductors) shall be measured as one span.)
Trimming/ lopping branches of tree touching to LT/HT OH lines / two pole structre/ 4 pole structre/ not exceeding 30 cm girth , shrub, vegetation, bushwood and saplings at least upto 3 M from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 1 Km and not exceeding 1.5 Km complete all as specified and directed. Note :- (i) Shutdown wherever required shall be taken in writtig from Engr-in-Charge. (ii) Distance between two consecutive poles shall be measured as one span.
M&L for preparation of old painted surfaces erected steel tubular swaged poles with fixed items/Rails/ Girder poles of LT over head line ( Except embedded portion) , 9/11 Mtr long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and red white 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on yellow synthetic enamel piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified and directed.
Finding out fault in any size of cable, 1100V grade to 33000V with the help of Fault Testing Van by disconnecting of cable from both sides and making connection after fault finding and repairs upto a length of 500m complete all as specified & directed. Note:- All the equipments, tackle, T&P, Fault finding/ testing Van etc shall be arranged by contractor at his own cost. The rate quoted by contractor shall deem to be included and nothing extra shall be allowed.
Taking down Existing unsv ACB any Size from any panel and S& F ACB 4 Pole, TMR Based 630A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection (Note : Rate quotted includes terminal lugs ) (Make : Siemens: / Legrand /ABB/ Schneider )
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 500A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 400A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 350A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 250A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 200A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Taking down Existing unsv MCCB any Size from any panel and S& F MCCB 4 Pole, TMR Based 160A, Breaking capacity 36 KA, 415 V, 50 Hz with OL, SC protection alongwith spreader terminal and confirming IEC 60947/ IS-13947/PT-II/1993 and connectintion with Existing connection complete all as specified and directed.
Surface Dressing/Cleaning for LT panel / 2/4 pole structure area / transformer plinth area / sub station surrounding area including removing of tree branches, small tree, plants and bushes etc complete all as directed.
M&L for preparation of old painted surfaces cleaning by rubbing with wire brushes / knife on all side rusted area of existing LT panel / Feeder pillar box / junction box and applying two coats of synthetic enamel paint ((approved colour) by spray gun over a coat of red oxide primer and making it absolutely good finished including repair using MS plain sheet of existing gauge & other steel members (as requed) and welding etc complete all as specified and directed.
M& L for aluminium Bus bar 1100 volts capacity of various size of Amps load capacity with colour code insulation making hole , nuts/ bolts/ washers with fixed the existing LT panel board / FPB/ JBs / Transformer complete including removing unsv old bus bar all as directed by Engr-in-charge.
Taking out Unsv JBs/ FPB and Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK) (FPB ), outdoor type, minimum size 900 x 800x 600mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminium bus bar (LxWxH)400 x 50x10 mm installed on SMC/ porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 2.5 Sqmm. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 240 sqmm by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size lugs for terminal connections of cables, necessary brick foundation with plastering to the Panel board, All out going feeders shall be connected and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door pillar box etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates and Panel Builder should submit all Certificates before executing the job.)
MCCB 4 Pole, Thermal Magnetic Based 250 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC, EF protection, -01 No along with Spreader terminals.
Incoming :-
Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
S&F service main distribution (SMC JUNCTION BOX ) box minium inside size 395 x 235 x 150 with Bus bar 200 amps 4 pole for distribution of multiple nos of service connectios , (ISI marked )weather and moisture proof, nuts and bolted bus bar system, 200 Amps capacity complete incl removing unsv any type pole junction box all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m and n exc. 3.00m in depth and getting out in soft/ loose soil including trimming sides and bottom of trenches complete all specified and as directed by Engr-in-Charge.
D S Enterprises
Shikha Enterprises
Jain Traders
M/S JPS Electrical Engineer & Contractor
PARADISE INFRA POWER COMPANY
janta tradrers
GEPS PROJECTS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .