Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.8 L+₹59,399 (3.10%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹19.8 L+₹65,488 (3.41%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹24.8 L+₹5.6 L (29.1%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
11 Feb 2020, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Special repair of fitting and fixtures of JCOs / OR MD Accn, replacement and improvement of U/G cable and other connected items under GE Army Suratgarh at Suratgarh Mil Stn
2020_MES_314045_1
GE (A) SOG - 34/19-20
Open Tender
Civil Works
Item Rate
180 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹58,000
Yes
29 May 2020
11 Jan 2020
13 Feb 2020
11 Jan 2020
11 Feb 2020
5 Feb 2020
Amount
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Taking down carefully or drawing out from conduit, existing copper / aluminium point wiring for light, fan, bell, socket, power point etc complete including fixture and fittings such as switches, sockets, ceiling rose, pendent holder, light fittings, top sheet covers, fan regulators etc (excluding MS sunken boxes) and making good the disturbed surfaces of wall/ceiling complete all as specified and as directed by Engineer-in-charge. Note : Taking down of serviceable fittings shall be measured and paid separately.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 6 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 6 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 6 here-in-before but for One light point controlled by Two 2- way switches.
All as per Srl item No. 6 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 1.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch piano flush button 5 Amps single pole, two way complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge. Make :- Legrand, Havells, Cona, SSK
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F bell push, flush type, 5 Amp, 230 Volts grade complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F in replacement electric bell (ding - dong), AC, 230 Volts, Single pole & connecting up complete all as specified and directed by Engineer-in-charge. Make :- Legrand, Havells, Cona, SSK
S&F in replacement electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge. Make:- Legrand, Havells, Usha
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in L & T / Havells / Schneider
S&F in replacement flush mounting factory made TPN DB 4 way, 415 Volt, Double door, IP-43 protection, IK-09 with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507670 or equivalent in L&T / ABB / Schneider
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 32 Amps, Single Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408617 or equivalent in/ L&T / Crompton / Havells
S&F in replacement MCB 63 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408683 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 40 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408681 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 32 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408680 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 25 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408679 or equivalent in L & T / Havells / Schneider
S&F in replacement MCB 20 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408678 or equivalent in L & T / Havells / Schneider
S&F LED Lamp 12 watts suitable for normal holder complete all as specified and as directed by Engineer-in-charge. Make :- Syska, Philips, Crompton Greaves
S&F in replacement Energy efficient decorative ultra slim, prewired, Glaze LED batten (PC) ultra 22/24 watt LED light fitting lumens output not less than 2800 lumens (Day cool light), batten type with drive & polycarbonate housing and with all accessories prewired complete all as specified and as directed by Engineer-in-charge. Make :- Syska cat part No SSK-SQ2201-PC or equivalent in Philips / Havells / Crompton
S&F in replacement Energy saving 10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No RUGBYNEONFT10WLED760SSYM BOPC / Crompton Cat part No LBHE-10-CDL / Philips Model No WTWLEDS NW PSU S PC / Syska
S&F in replacement 14 watt LED mirror light fitting with high output diffuser complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge Make :- Crompton Cat Part No LCL-14-CDL or equivalent in Philips / Syska / Havells
Dismantling all electronic meters from the existing panel and refixing in new panel after testing, S&F single phase multi meter mounting box (650mm x 450mm x 150mm ) for mounting 04 Nos electronic meter, shockproof and rustproof, termite resistant, cable entry from bottom side, 100% weather proof, pole mounting arrangement, , temper & pilferage proof , fire retardant-class FV-0 as per IS 11731 part-II or V-0 as per UL-94 Make Sintex Model No GSMB 6545 or equivalent in L&T
S&F in replacement Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 2.5Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 2.5 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one RM.
S&F in replacement street light bracket made out of 40mm dia GI pipe light grade 1.50m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing in replacement LED Street / Security light fitting of 45 Watt, 5700K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SLG-N-45W / Crompton Cat Part No LSTP-45-CDL / Havells Cat part No ENDURAPEARLNEOSL45WLED757SASYTOPC / Jaquar cat part No LSRT01S045XC / Wipro Cat Part No LR02-501-XXX-57-XX
Notes for srl item No 37 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account. (g) Old unserviceable street light shall be deposited in AGE E/M store yard by the contractor at his own arrangement. Noting extra shall be paid on this account.
Suppyling, installing, testing and commissioning of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 38 Incoming (a) 300 Amps aluminium bus bar for phases and 300 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250, 420248 or equivalent in L&T / Schneider / ABB Outgoing (a) On load change over switch 415 volts, 125 Amps, 4 pole, type CO2 - 200 - 01 No Make :- L&T Cat Part No CO22000OOOA or equivalent in Havells / Legrand (b) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420055 or equivalent in L&T / Schneider / ABB (c) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 No Make - Legrand Cat Part No DPX³ 160, 420053 or equivalent in L&T / Schneider / ABB (d) MCCB 40 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420052 or equivalent in L&T / Schneider / ABB (e) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (f) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (g) CTs 200/5 Amps - 01 Set (set of three) (h) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp
All as per item No 38 above but comprising of following accessories :- Incoming (a) 200 Amps aluminium bus bar for phases and 200 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420055 or equivalent in L&T / Schneider / ABB Outgoing (a) MCB 32 Amps, Triple Pole & Neutral 415 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408680 or equivalent in L&T / Schneider / ABB (b) MCB 20 Amps, Triple Pole & Neutral 415 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408678 or equivalent in L&T / Schneider / ABB (c) MCB 63 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408683 or equivalent in L&T / Schneider / ABB (d) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (e) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (f) CTs 200/5 Amps - 01 Set (set of three) (g) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp
All as per item No 38 above but comprising of following accessories :- Incoming (a) 100 Amps aluminium bus bar for phases and 100 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420053 or equivalent in L&T / Schneider / ABB Outgoing (a) MCB 20 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, - 03 No Make :- Legrand Cat Part No 408678 or equivalent in L&T / Schneider / ABB (b) MCB 32 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, - 03 No Make :- Legrand Cat Part No 408680 or equivalent in L&T / Schneider / ABB (c) MCB 40 Amps, Triple Pole & neutral 415 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408681 or equivalent in L&T / Schneider / ABB (d) MCB 32 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408617 or equivalent in L&T / Schneider / ABB (e) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (f) Digital Ampere meter flush type 0-100 Amps square type 96mm x 96mm - 01 No (g) CTs 200/5 Amps - 01 Set (set of three) (h) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp
All as per item No 38 above but comprising of following accessories :- Incoming (a) 200 Amps aluminium bus bar for phases and 100 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420053 or equivalent in L&T / Schneider / ABB Outgoing (a) MCB 20 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408615 or equivalent in L&T / Schneider / ABB (b) MCB 32 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 04 No Make :- Legrand Cat Part No 408617 or equivalent in L&T / Schneider / ABB (c) MCB 40 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 03 No Make :- Legrand Cat Part No 408618 or equivalent in L&T / Schneider / ABB (d) MCB 32 Amps, Triple Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, - 01 No Make :- Legrand Cat Part No 408680 or equivalent in L&T / Schneider / ABB (e) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp
All as per item No 38 above but comprising of following accessories :- Incoming (a) 300 Amps aluminium bus bar for phases and 300 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 160 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420097 or equivalent in L&T / Schneider / ABB Outgoing (a) MCB 40 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 02 No Make :- Legrand Cat Part No 408681 or equivalent in L&T / Schneider / ABB (b) MCB 32 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 01 No Make :- Legrand Cat Part No 408680 or equivalent in L&T / Schneider / ABB (c) MCB 25 Amps, Triple Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 03 No Make :- Legrand Cat Part No 408679 or equivalent in L&T / Schneider / ABB (d) MCB 32 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, - 04 No Make :- Legrand Cat Part No 408617 or equivalent in L&T / Schneider / ABB (e) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (f) Digital Ampere meter flush type 0-250 Amps square type 96mm x 96mm - 01 No (g) CTs 200/5 Amps - 01 Set (set of three) (h) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
M&L for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3.50m length buried directly and preferably vertically in ground with top edge not less than 0.25m below ground level, pipe surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by electric welding and connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 2 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engr-in-charge. Note:- (i) GI strip upto earth test point/equipment is included in this item. (ii) Minimum weight of reinforcement for RCC cover shall be 1 KG. (iii) Pipe electrode shall be tapered at the bottom and provide with 12mm holes (staggered) at 75mm centre to centre up to 2 meter height.
Supplying, laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 6 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 45 above but cable of cross sectional area 10 sq mm 2 core
All as per item No 45 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 45 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 45 above but cable of cross sectional area 25 sq mm 3.5 core
All as per item No 45 above but cable of cross sectional area 50 sq mm 3.5 core
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 70 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 51 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 51 above but cable of cross sectional area 185 sq mm 3.5 core
Supplying, jointing and testing in replacement heat shrinkable type indoor / outdoor, end termination jointing kit, suitable for cable of size 70 to 120 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 54 above but suitable for cable of size 150 sqmm to 185 sqmm.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
All as per Srl item No 59 above but 50 mm dia bore.
All as per Srl item No 59 above but 80 mm dia bore.
All as per Srl item No 59 above but 100 mm dia bore. ---------------------------------------------------------------------------------------------------------------------------------------- Note :- A sum of Rs. 112306- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 25 (Schedule of Credit) of Tender documents.
Gupta Suppliers
S.K BUILDERS AND ENGINEERS
DASHMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .