Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹66.4 L+₹60.5 L (1024.5%)Rejected-Finance 114 4 3 HAZRA ROAD KOLKATA 700026 | KOLKATA | WEST BENGAL | 700026 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹7.2 L+₹1.3 L (22.5%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Non_Submission_of_ShortFall_Documents |
Tender Value
₹5.8 L
EMD Value
₹11,500
Closing Date
29 Nov 2024, 12:00 pmClosed
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
75 Diamond Harbour Road Kolkata 23
IPGMERSSKM Hospital Emergent work with aluminum partition curtains opening of new door and orientation of toilet block at 1st floor 2nd floor and 6th floor for creation of HDU Biopsy room pre transplant room at UroNephrology building during FY 24 25
2024_WBPWD_766627_1
WBPWD/EE-I/KSHED/Q43/24-25/2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
SSKM Hospital Kolkata
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,500
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
4 Apr 2025
30 Oct 2024
2 Dec 2024
30 Oct 2024
29 Nov 2024
11 Nov 2024
11 Nov 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type witch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. akelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.
Average run 9 mtr
Supply & Fixing 240 V, 3 nos. 20A plug socket with separate 3 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. AS PER GS.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board complete with 3 nos suitable size copper bar with holes (for Ph,N & E) fixied on bakelite/Hard rubber insulator over the MS welded chairs and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S/D following sizes PVC insulated & unsheathed Cu.wire in 19mm / 25mm / 32mm bore 3mm thick polythene pipe embedded in wall complete with all accessories incl. cutting the channel and mending good the damages incl. making connections as to G.S.:- [Make of Wires - Finolex / Havell's / RR Kable ]
a) 2 x 2.5 & 1 x 1.5 mm² for 15A Power plug
b) 2 x 4 & 1 x 2.5 mm² from PDB to Power Plug
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as pre GS as follows :-
a) 2 x 2.5 & 1 x 1.5 mm² cu. Wire
b) 2 x 4 & 1 x 2.5 mm² cu. Wire
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing of 12'' Heavy Duty exaust fan with making hole complete with all accessories having the following Model / Cat No. ( Make -EPC Electrical Pvt. Ltd. ) Speed 1420 RPM with S/F 2 " Alumiuam louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
S & F 250V 25A Timer controller for AC machine in SS double door 2+10-way DB enclosure (Make:- L&T, encloser cat no DBSPN012DD) or equvalant) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :- i) 10kA, C-Curve, 240V, 25A ,DPMCB (LT/Schnider/ABB Elegance) --- 1 No ii) 24 Hr programmable Digital/Analog Timer (LT make cat no 67DDT0) ---- 1 No iii) 3 pole power contractor (LT make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 1 set iv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) ---- 1 No. v) 2 Module plate with cover (Make :- Legrand/Myrius) -- 1 No vi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make) ---- 1 No. vii) 10A SPST Moduler type switch (Make :- Legrand/Myrius) - 1 No. viii)Outgoing connector make ELMAX (Approved/reputed make) - 1 No.
S&D of minimum 2.0 Tr Capacity ceiling suspended [concealed] Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary / Twin Rotary Compressor with minimum Cooling Capacity not less than 7.05 KW, Air Flow not less than 640 CFM, Moisture Removal should be 2.5 I/hr, EER not less than 2.65 KW/KW, Minimum cu. pipe Length from ODU to IDU not less than 25 MTR & suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wired/ Wireless remote & all other accessories complete with refrigerent (Make : Mitsubishi heavy industries / O General (Model No. : ARG25F/AOG25F) / Daikin ).
Installation, testing & Commissioning 2.0 Tr Concealed Split type AC Machine with all accessories i.e., fastner, nut bolt, wall cutting, all glass window/grill cutting where needed with S&F heavy gauge ODU iron brecket, IDU tie rod etc. incl. mending good damages as per direction of EIC.
Supply & fixing of HVAC grade copper pipe (0.9 mm min.) with minimum thickness 9 mm Nitril Rubber insulation of following sizes for liquid and gas line between ODU and IDU (Make - Ryoku/Nippon):-
5/8" (gas line / suction).
1/4" (liquid line/ discharge line).
Supply, installation & commissioning PVC Drain pipe line (25mm OD HD 1mm thick) with Class O fire rated nitrile rubber insulation & supports & brackets (For 2.0 Tr concealed split AC).
S&D of Daily Weekly Programmable Electronic 110 240 VAC Crono Timer Switch, 50/60 Hz, 1 C/O SPDT Cat. No. : 67DDT0 (Black) [for AC m/c timer DB]. [Make- L&T or equivalent].
S&D of Programmable Electronic time switch for Toilet Exhaust Fan as per direction of EIC. [Make- GIC, Cat No. V7DFTS3, Model or equivalent].
Supply and fixing of air curtain made of CRCA sheet fabricated with pure polyester powder coating paint body suitable for 68 inch wide door consisting of 1no motor with 2 nos blower suitable to run with 230V/ 50 Hz /1 phase power supply. [Makes - Airotek / Techno mech sales].
Defect Liabibility Period 1 (One) year
Make & model of each and every material to be approved by EIC
NEW INDIA ELECTRICAL AND ENGINEERING WORKS (BID ID -5753336)
SKY DECORATIONS PRIVATE LIMITED (BID ID -5788542)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .