| 1 | L1₹14.8 LAccepted-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹17.4 L+₹2.7 L (18.2%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹17.5 L+₹2.7 L (18.4%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹18.7 L+₹3.9 L (26.6%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹20.4 L+₹5.7 L (38.4%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Feb 2025, 6:00 pmClosed
SHRI JITENDRA KUMAR MEENA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8638/E8
2025_MES_691496_1
8638/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VASCO
Class E Category b i
8 documents required · 8 mandatory
₹500
GE (NW) VASCO
₹40,000
Yes
31 May 2025
2 Jan 2025
5 Feb 2025
2 Jan 2025
3 Feb 2025
16 Jan 2025
3 Jan 2025 - 15 Jan 2025
Amount
Checking and attending day to day electrical complaints for continuous electric supply like No light / Short circuit / non working fittings / fixtures/ fan/ exhaust fans/ geyser, including carrying out the minor repair like fixing screws, repair/ replacements of short wire, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.5 mtr length and maintenance work complete on all working days all as directed.
Note for item No 1:- (a) Rate inclusive of small items like, screws, wire,etc . (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for repair works as directed by Engineer-in-Charge shall be supplied by the contractor and adequate stock shall be held all the time by contractor (d) Any nature of electrical complaint, the entire responsibilty of rectification lies with the contractor. "(e) Contractor shall be penalised @ Rs. 2000/- per day per complaint, if he fails to attend the complaint within 12 hours. (f) All serially numbered complaint docket will be provided by contractor and cost of docket included in the rate quoted for the items. (g) All T&P, safety gadgets shall be provided by the contractor. (h) Rep of the contractor shall receive complaints in morning 0900 hr and give feedback on daily basis to concerned JE E/M
(j) Payment to contractor released after submission of these complaints duly rectified within time and duly signed by contractor, JE, and Engineer-in-Charge in RAR/Final bill. (k) Contractor shall maintain the maintinance register showing all daily complaints recieved and shall maintain job cards for attending complaints. The signature of the user shall be obtained on the job card showing the material incorporated in the work after completion of the job with date."
Supply and fix in repair, switch piano type single pole one way 5 Amps, 230 V complete all as specified and directed .
Supply and fix in repair, socket outlet 2 in 1, 3 pin, 5A single pole, 230 V complete all as specified .
Supply and fix in repair, switch piano SP two way 5Amps, 230 V complete all as specified and directed.
Supply and fix in repair, switch piano flush button type, single pole, 15 Amps, 230 V complete all as specified
Supply and fix in repair socket outlet flush type 2 in 1, 3 pin 5 and 15 Amp single pole ,230 V complete all as specified and directed by Engineer in charge.
Supply and fix in repair, bell push single pole, 5 Amps, 230 V complete all as specified and directed by Engineer in charge.
Taking down unserviceable aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed adjoining / adjacent surfaces / items complete all as specified and as directed.
Material labour for point wiring for one light complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS grade (for phase, neutral & earth continuity with proper colour code) drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall / ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth continuity conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches, sockets etc concealed on wall complete all as specified and as directed. Note: (i) Contractor should make good / match the disturbed surface to the original. (ii) The description is applicable for Item Nos 9.01,9.02,9.03, 9.04 & 9.05 only.
One light point controlled by one switch complete
One Fan/exhaust fan point controlled by one switch complete.
One 3 pin socket outlet,5 Amps complete.
One Light point controlled by 2 way switches complete.
One call bell point controlled by push button complete.complete.
Material and labour for point wiring complete with 1100 volt grade PVC insulated unsheathed multistranded 2.5 sqmm copper cudutor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing and capping (including accesaries)in Ivory/Grey/white colour medium grade of size 25/20 mm etc fixed on wall/ceiling including provision of 02 run of 2.5 sqmm PVC unsheathed copper conductor and Connected to earth dolly including provison of pressed steel ternal box with 3 mm thick plastic laminated sheet top cover housing switches/ sockets etc concealed to wall etc and making good the disturbed portion as existing complete complete all as specified and as directed.
Taking down unservicable submain wiring Aluminium / copper of any size /core/ type including earth continuity condutor on teak wood or conduit and removing the materialss/debris from site and making good the disturbed surfaces of wall etc to match with the original existing finish all as directed.
Material and labour for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing and capping (including accesaries)in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 6.0 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 6.0 sqm including 01 run of PVC casing caping complete all as specified and directed.
Supply and fix in repair PVC ceiling rose, surface type with three terminals complete all as specified and directed.
Supply and fix in repair electric Ding Dong AC 230 volt etc all as specified and directed.
S & F in repair Integrated Inverter LED batten T5 tube light fitting type 1x 20 watt indoor type complete with lithium ion battery with charging time 8 to 10 hours and backup time upto 3 hours including all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed Make: Havells Cat part No:- LHEXACP7FN1W020 or technocommecially equivalent in other make as specified in list of manurfacturer in the tender documents her in after in appx patricular specification. Note:- (a) The contractor shall write CA No and date of completion on each LED fittings and he is liable to replace the defective items a week on intimation by the department (Engr-in-Charge/GE) that lies with defect liablity period /warrenty period of particular material/items issued by manfucturer/Authorised dealer.
S & F Inverter LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 v AC with driver and LED tubelight including with lithium ion battery with charging time 8 to 10 hours and backup time upto 3 hours with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed Make: Orient Cat part No: LED 10WBT-EM65K-PO2, Plastic or techno commecially equivalent in other make as specified in list of manurfacturer in the tender documents her in after in appx patricular specification. Note:- (a) The contractor shall write CA No and date of completion on each LED fittings and he is liable to replace the defective items a week on intimation by the department (Engr-in-Charge/GE) that lies with defect liablity period /warrenty period of particular material/items issued by manfucturer/Authorised dealer.
Supply and fix in repair Isolator DP 40 Amps 240 volts 10 KA 50 HZ, 'B' curve complete all as specified and directed.
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed.
Supply and fix MCCB 4 pole 63 Amp with breaking capacity 16 KA, 415 volt 50 HZ AC supply complete all as specified and directed.
Supply and fix MCCB 4 Pole 250 Amp with breaking capacity 36 KA, 415 volt 50 HZ AC supply complete all as specified and directed.
Supply and fix in repair hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 4"x4". :- Make :-As per sample.
Supply and fix in repair hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of sizes 8"x10". :- Make :-As per sample.
Supply and fix in repair hylam sheets 3mm thick including cutting for mounting of switches / sockets / suitable for sunken box of sizes 10"x12". :- Make :-As per sample.
Supply and fix in repair PVC connection pipe of 12 mm ((internal) suitable for hot/cold water, 45 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply and fix in repair hole fastner madeup of MS 10mm dia standard length with nut bolt complete all as specified and directed.
Supply and fix in repair heating element of 1.5/2 KW any type with nut bolt washer complete as per site requirement all as specified.
Supply and fix in repair thermostat for 6"/11" suitable for geysers of capacity 25/50 Ltrs complete all as specified and directed.
Taking down unserviceable existing DB SPN 8/10/12 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
Supply and fix MCB DB, single pole and neutral with suitable rated busbar double door, 8 way 230 volt 50 HZ AC Supply complete all as specified and directed. NOTE: contractor should match the disturbed surface to the original.
Supply and fix in repair Inverter LED bulb of 9 Watt . Make :- Havells Cat part NO:- LHLDEGEDML80009 , lumen output 900 Lumen , 6500 K base cap B22 technocommecially equivalent in other make as specified in list of manurfacturer in the tender documents her in after in appx patricular specification. Note:- (a) The contractor shall write CA No and date of completion on each LED fittings and he is liable to replace the defective items a week on intimation by the department (Engr-in-Charge/GE) that lies with defect liablity period /warrenty period of particular material/items issued by manfucturer/Authorised dealer.
Supply and fix in repairs capacitor of capacity 2.5mfd/4mfd, 230 V for ceiling fan/exhaust fan including removing old one complete all as specified and directed .
Supply and fix in repairs rubber reel with MS nut Bolt,split/quarter pin for hanging ceiling fan suitable for C/fan complete all as specified and directed.
Supply and Fix in repair Fan motor Complete suitable for 1200mm sweep ceiling Fan complete all as specifed and directed.
Supply and fix in repair Fan Blade suitable for 1200 mm Sweep ceiling Fan complete all as specifed and directed.
Supply and Fix in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan Metal body matching to existing location complete all as specifed and directed.
Supply and Fix in repair Fan motor complete suitable any make and sweep upto 300 mm Sweep exhasut Fan Metal body matching to existing location complete all as specifed and directed.
Supply and Fix in repair Fan Blade suitable of any make and sweep up to 300 mm sweep Exhaust Fan plastic body matching to existing location complete all as specifed and directed.
Supply and Fix in repair Fan motor complete suitable any make and sweep upto 300 mm Sweep exhasut Fan plastic body matching to existing location complete all as specifed and directed.
Supply and fix in repairs Ceiling fan regulator electronic step switch type/socket type(Matching to existing location), suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete all as specified and directed.
Supply only PVC insulated body, angle / Straight lamp holder with back plate complete all as specified and directed Note :- The all unserviceable mtrls retrived from site for replacement to be deposited in AGE E/M-II store
Supply only PVC isulated multistranded Copper Conductor Cable 1100 V grade 1.5 Sqmm size for day to day repair work. Note :- The all unserviceable mtrls retrived from site for replacement to be deposited in AGE E/M-II store.
Shree Ram Enterprises (BID ID -3220237)
Bharat Sales Corporation (BID ID -3225647)
M/S VIDHYUT ENGINEERS (BID ID -3221030)
Sagar Constructions (BID ID -3230737)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .