| 1 | L1₹37.5 LAccepted-AOC VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.8 L+₹1.3 L (3.42%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.9 L+₹2.4 L (6.35%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.2 L+₹5.7 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.2 L+₹6.8 L (18.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹44.8 L
EMD Value
₹89,600
Closing Date
25 Mar 2023, 6:00 pmClosed
Maj Ashwin Awadh
Garrison Engineer West 62 Station Road Agra Cantt
PROVN OF KOT AND GUARD ROOM ALONGWITH AMN MAGAZINE FOR UNIT KOT SECURITY GUARD CONSISTING OF 01 X NCO X 06 X OR FOR ROUND THE CLOCK SECURITY NEAR SHED NO 107, 108 , PROVN OF 30 X CEILING FANS FOR OR LIVING AT 50 (I) PARA BDE OFP UNDER GE (WEST) AGR
2023_MES_582636_1
8012/944/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Agra
₹89,600
31 Mar 2023
24 Feb 2023
29 Mar 2023
24 Feb 2023
25 Mar 2023
11 Mar 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed by Engineer in charge.
M&L in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc, or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil as in foundation complete all as specified and directed by Engineer in charge.
M&L cement concrete in foundations, filling and mass concrete type D2 1:4:8(40mm graded stone aggregate) complete all as specified and directed by Engineer in charge.
M&L brick work with fly ash bricks,old size bricks, straight or curved on plan exc 6m mean radius built in cm (1:6) complete all as specified and directed by Engineer in charge.
M&L brick work with fly ash bricks,old size bricks, straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specified and directed by Engineer in charge.
Returning filling in trenches in layers n. exc 25cm thick, watering, well ramming complete in soft/loose soil complete all as specified and directed by Engineer in charge.
Removing excavated material n. exc 50m and depositing where directed at level n. exc 1.50 in soils complete all as specified and directed by Engineer in charge.
M&L for reinforced cement concrete (nominal mix) as in footing, foundation beam, plinth beams, bases for columns etc,basement slabs,under-reamed piles and mass concrete type B1 1:2:4 ( using 20mm graded stone agg) etc complete all as specified and directed by Engineer in charge.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter rough finished surface of concrete complete all as specified and directed by Engineer in charge.
M&L for reinforced cement concrete (nominal mix) as in columns, pillars, piers, posts and struts,type B1 1:2:4 ( using 20mm graded stone agg) etc complete all as specified and directed by Engineer in charge.
Formwork to sides of pillars,posts, struts, piers, columns and stanchions rough finished surface of concrete flat. complete all as specified and directed by Engineer in charge.
M&L for reinforced cement concrete (nominal mix) as in beams, cantilevers, bressummers, lintels over 1.5m span type B1, 1:2:4 ( using 20mm graded stone agg) etc complete all as specified and directed by Engineer in charge.
Formwork to sides and soffits of floor or roof beams, beam hanunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed by Engineer in charge.
M&L for reinforced cement concrete (nominal mix) as slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like type B1 1:2:4 ( using 20mm graded stone agg) etc complete all as specified and directed by Engineer in charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) rough finished surface of concrete flat complete all as specified and directed by Engineer in charge.
M&L for cement concrete in lintels upto 1.5m clear span, type B1 1:2:4 ( using 20mm graded stone agg) etc complete complete all as specified and directed by Engineer in charge.
M&L for precast cement concrete in shelves type B1 1:2:4 ( using 20mm graded stone agg) set in cement mortar 1:4.complete all as specified and directed by Engineer in charge.
M&L Anti Termite Treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer in charge.
M&L Anti Termite Treatment for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer in charge.
M&L for machine cut kota stone slab flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing including 15 mm thick screed bed C:M 1:4 complete all as specified and directed by Engineer in Charge.
all as per item No 20 but as in skirting/ dado etc complete all as specified and directed by Engineer in charge.
M&L damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0,25 mm thick including necessary formwork etc complete all as specified and directed by Engineer in charge.
Supply only liquid intergral water proofing compound complete all as specified and directed by Engineer in charge.
S&F mild steel TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns hooking ends and binding with mild steel wire anealed not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in charge.
.All as per item No -24 above but 5mm dia and over upto and including 10mm dia in stirrups etc complete all as specified and directed by Engineer in charge.
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces etc complete all as specified and directed by Engineer in charge.
M&L for 15mm thick rendering in CM 1:4 on other than fair faces of brick work or concrete surfaces etc complete all as specified and directed by Engineer in charge.
M&L for rendering 5mm thick in CM 1:3 on ceiling surface complete all as specified and directed by Engineer in charge.
M&L for moorum filling in floors or pavings laid in layers n. exc 15cm thick spread, levelled and rammed including watering etc complete all as specified and directed by Engineer in charge.
M&L for hardcore of broken stone or boulders of gauge n. exc. 63mm, deposited,spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge.
M&L for PCC type D2, 1:4:8 (40mm graded stone agg) 100mm thick as in sub base etc complete all as specified and directed by Engineer in charge.
M&L for PCC 1:2:4 type B-1 ( 20mm graded stone agg) 40 mm thick as in floor, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer in charge.
M&L coloured non skid ceramic tiles 7mm to 8mm thick ( square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer in charge.
M&L coloured non skid ceramic tiles 7mm to 8mm thick ( square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screedbed in CM 1:6 complete all as specified and directed by Engineer in charge.
M&L coloured tile glazed ceramic in vertical surfaces 300x200x7mm set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick in CM 1:4 complete all as specified and directed by Engineer in charge.
S & F steel windows with side hung shutters incl box type hinges with Z section handle and steel peg stay complete with glazing bars, dovetailed or welded complete all as specified and directed by Engineer in charge.
all as per Srl item No 36 above but without glazing bars complete all as specified and directed by Engineer-in-Charge.
S&F steel ventilator top hung shutter including hinges steel peg stay complete all as specified and directed by Engineer in charge.
S&F steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed by Engineer in charge.
S&F pressed steel door frame of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strikc plate etc complete all as specified and directed by Engineer in charge.
M&L for PCC 1:3:6 type C1 as in back filling of pressed steel door frames complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete Type B1 1:2:4 (using 20 mm graded crushed stone aggregate) in PCC blocks for holdfasts, benching, coping and the like including weathering,slightly rounded or chamfered angles complete all as specified and directed by Engineer in charge.
S&F 40 mm thick flush shutter solid core construction with particle board core and plywood face panel, commercial type on both sides complete all as specified and directed by Engineer in charge.
S&F 35 mm thick IInd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed by Engineer in charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50 sqm in each pan etc complete all as specified and directed by Engineer in charge.
S&F 3 mm thick figured glass, him head type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer in charge.
S&F 0.56mm nominal dia of wire and 1.18mm average width of aperture mild steel galvanised wire cloth etc complete all as specified and directed by Engineer in charge.
S&F 200mm long aluminium anodised,barrel tower bolts of ex truded section and fixed complete all as specified and directed by Engineer in charge.
S&F 150mm long aluminium anodised,barrel tower bolts of ex truded section and fixed complete all as specified and directed by Engineer in charge.
S&F 250mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed etc complete all as specified and directed by Engineer in charge.
M&L for preparation of new or previously untreated wooden surfaces over 10cm in width or grith and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer in charge.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new plaster surfaces of wall and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed by Engineer in charge.
M&L for preparation of new paster surfaces of ceiling and applying three coats of white wash etc complete all as specified and directed by Engineer in charge.
M&L for preparation of newly plastered wall surfaces and applying two coat of distemper oil emulsion over a coat of primer complete all asspecified and directed.
M&L for cement concrete 1:3:6 type C-1, (using 20mm graded stone aggregate) , in plinth protection 50mm thick finished even and smooth without using extra cement including making joint 12 wide to the full depth of PCC at max 3 mtrs and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed by Engineer in charge.
M&L Anti Termite Treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer in charge.
M&L for GI pipe medium grade 15mm dia to walls and ceilings or laid in floors etc complete all as specified and directed by Engineer in charge.
M&L for GI pipe medium grade 20 mm dia to walls and ceilings or laid in floors etc complete all as specified and directed by Engineer in charge.
S&F 500 ltrs capcity rotational moulded polythene water storage tank ( cylindrical vertical with closed top) haisted and fixed in position complete all as specified and directed by Engineer in charge.
S&F 15mm dia bib tap,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in charge.
S&F 15mm dia stop valve ,fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer in charge.
S&F 15 mm dia Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixe complete all as specified and directed by Engineer in charge.
S&F 20 mm dia Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixe complete all as specified and directed by Engineer in charge.
S&F 15mm dia Pillar taps, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed by Engineer in charge.
S&F 20 mm dia ball brass valves,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer in charge.
S&F 32mm dia waste coupling of PTMT half of full threadel etc complete all as specified and directed by Engineer in charge.
S&F grating round 140mm size of PTMT etc complete all as specified and directed by Engineer in charge.
S&F Towel rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and directed by Engineer in charge.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer in charge.
S&F 110mm dia PVC(SWR) pipes single sockets in any length with rubber ring joints laid to walls ,floor,trenches etc complete all as specified and directed by Engineer in charge.
S&F 110 mm bore PVC (SWR) single T with access door equal of unequal angle etc complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) bend 110mm dia with access door complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) floor trap, plain with grating including jointng with solucent cement of 75mm dia complete all as specified and directed by Engineer in charge.
S&F PVC (SWR) pipes single socketed in only length 75mm dia with rubber ring joints, laid in trenches or in floor,fixed to wall etc complete all as specified and directed by Engineer in charge.
S&F vitreous china wash hand basin white flat back, size 550x400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed by Engineer in charge.
S&F PVC low level flushing cistern 10 ltrs capacity white with inlet ball value, float valve and handle incl brackets,CP brass flush pipe and bend complete all as specified and directed by Engineer in charge.
S&F WC Orissa pattern white with integral foot rest 580x 440 mm including, PCC bedding in 1:2:4 and making good disturbed floor connecting to trap and flush pipe compete all as specified.(Rate of including in taking out and remocal of old WC seat unhygienic condition) complete all as specified and directed by Engineer in charge.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum),with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipecomplete all as specified and directed by Engineer in charge.
S&F brass chromium plated shower rose repair 125 mm size with or without swivel joint complete all as specified and directed by Engineer in charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification & drawing complete all as specified and directed by Engineer in charge.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site incl 3 nos pvc hinge 100 mm long Aluminium handle 2 nos and tower bolts 100 mm longs 2nos as per specification & drawing complete all as specified and directed by Engineer in charge.
M&L for concrete bed to drain pipes incl packing under,and hunching against thesides after they are laid and tested complete all as specified and directed by Engineer in charge.
S&F for stoneware drain pipes150 mm laid in trenches and jointed as specified complete all as specified and directed by Engineer in charge.
S&F 25mm dia decorative powder coated drapery rod, colour as approved with seasoned teak wood rings and brackets, fix to wall concrete complete all as specified and directed by Engineer in charge.
S&F framed work such as grills, gratings etc with ends of bars shouldered and guard bars and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer in charge.
Providing water proofing treatment over RCC roof including projection as follows :- (a) Complete cleaning of roof surface of any description and in any position (b) The slab shall be finished with 10mm thick cement plaster in cement mortar 1:4 finished even and smooth (without using extra cement) mixed with water proofing compound as per manufacturer's instructions. The cement plaster shall be provided while the concrete of the slab in green (c) Apply a coat of bituminuos primer conforming to IS-3384 @ 0.3 liter/Sqm on the prepared surface of plaster. After drying of primer, apply a coat of hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-702 @ 1.2 Kg/Sqm of plastered surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, end overlaps shall not be less than 150mm as side lap 75. Polymeric water proofing membrane should be five layered with centre core as 90 microns high molecular high density polythylene film Minimum weight of water proofing membrane shall be 3Kg per Sqm. The contractor shall produce purchase vouchers and test certficate from the manufcture for the same. The products of following firms shall be used for water proofing membrane (i) Hyper Plus standard-Manufactred byM/S IWL India Ltd 755 LIG Flat Hest SAL New Delhi 110039 (ii) Multi Plus-Manufactured by M/S STP Texas Ltd, A-4/8, Ist Floor DLF city, Ph-I Gurgoan-1220002. (iii) Bengal Acquaflux-Bengal Bitumen, Sarita Vihar, New Dlhi (iv) Superior Poly Plus 310 by STP Ltd (e) Over the polymeric water proofing membrane apply semi hot blown VG 20 paving grade (60-80 penetration) bitumen conforming to IS-702 @ 1.2 Kg/Sqm of roof surface and blinded with fine sand in dry condition @ 0.5 Kg/Sqm dusted over the bitumen coat (f) Covered fillet in PCC (1:2:4) type B-0 radius 75mm be provided at the junction of roof and vertical surface such as paraper wall/mumty/chimney around opening and treatment mentioned above except fine sand) shall be applied followed by a cement plaster 20mm thick in ceement mortar (1:6). Complete treatment shall be carried out by the applicator of the manufacturer of membrane. (g) Provide PCC padding 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness each with chicken wire mesh 0.90mm dia and 12mmx12mm aperture, laid between two layers. Top surface of PCC padding shall be finished even and smooth without using extra cement and 12mmx12mm aperture with flase groove and 300x330mm centre to centre.
S&F for shelf of PTMT fixed with and incl CP brass screw and wooden /plastic cleats min wt 300 gms complete all as specified and directed by Engineer in charge.
S&F for framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing of FE-410-W(Gde-E-250) complete all as specified and directed by Engineer in charge.
S&F 1.25 mm thick mild steel, plain, black sheet covering to door shutters; door chowkats (frames) etc complete all as specified and directed by Engineer in charge.
M&L for PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement. complete all as specified and directed by Engineer in charge.
M&L providing precast cement concrete louvres and jallies, 35mm thick type B0,1:2:4 (12.5mm graded aggregate) set in cement mortar 1:4 (measured solid), including all mouldings but excluding frame (precast frame shall be measured and paid separately) complete all as specified and directed by Engineer in charge.
Spreding and levelling in layers n.exc 25 cm thick well ramming including watering as required complete all as specified and directed by Engineer in charge.
M&L cement concrete in foundations, filling and mass concrete type D2 1:4:8(40mm graded stone aggregate) complete all as specified and directed by Engineer in charge.
M&L for hardcore of broken stone or boulders of gauge n. exc. 63mm, deposited,spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge.
M&L 75 mm thick PCC (1:4:8) type D-2(using 40mm graded crushed stone agg)as in sub base of floor complete all as specified and directed by Engineer in charge.
M & L chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment on screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer in charge.
20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10 mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer in charge.
S&F cast iron work grade FE 150, machined, in pulleys and similar articles n.exc 5 Kgs each complete all as specified and directed by Engineer in charge.
M&L for GI tubing 80 mm dia medium grade with all fittings fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer in charge.
M&L for preparation of new paster surfaces of wall and applying two coats of cement base paint over a coat of primer etc complete all as specified and directed by Engineer in charge.
M&L for hardcore of broken stone or boulders of gauge n. exc. 63mm, deposited,spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge.
M&L cement concrete in filling and mass concrete or sub base type E2 1:5:10 (using 40mm graded stone aggregate) complete all as specified and directed by Engineer in charge.
M&L for 100mm thick cement concrete type B2 1:2:4 (using 40mm graded stone aggregate) finish surface even and smooth using extra cement complete all as specified and directed by Engineer in charge.
Forming 20mm thick expansion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' (Thickness of concrete slab is 100mm) complete all as specified and directed by Engineer in charge.
M&L rendering 10mm thick on fair faces of brick work or concrete surfaces finished even and smooth W/O extra cement in cement plaster 1:3 complete all as specified and directed by Engineer in charge.
All as per ser item No 2 hereinbefore but exceeding 1.5 meter and not exceeding 3 mtr depth complete all as specified and directed by Engineer in charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded stone aggregates as in concrete bed to drain pipes including forming cradles for 150 mm bore pipe after the pipes are laid and tested complete all as specified and directed by Engineer in charge.
Supply and laying 150 mm bore reinforced concrete pipes, class NP3, laid and jointed complete with collar laid in trenches and jointed in cement mortar 1:1 including testing complete all as specified and directed by Engineer in charge.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM (1:4) directed complete all as specified and directed by Engineer in charge.
RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in precast slabs for covers of manholes including necessary form work and placing of manholes cover in position complete all as specified and directed by Engr-in-Charge.
Construction of RCC septic tank designed to carry sewage and sludge water , excavation in any type of soil, PCC 1:4:8 below foudation RCC M-30 design mix in walls, base slab, baffle walls and Roof slab including beams etc with vent shaft, manhole opening with cover construction etc complete with effective depth of 1.5 mtr and over all depth of 3 Mtr for 10 users complete all as specified and directed by Engineer in charge.
Soakage wells exc, in ordinary soil, foundation in PCC 1:3:6, walls of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber, brick work in CM, RCC cover slab in M-25/RR Masonary/filling with brickbats, complete of size 1.80 m dia x 3.00 m deep complete all as specified and directed by Engineer in charge.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus oil to a distance n exc 50 M and making good surface in soft/loose soil complete all as specified and directed by Engineer in charge.
S & F post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) incl all necessary drilling, bolting and riveting, etc, and similar work conforming toFe-290 Gde E-165. complete all as specified and directed by Engineer in charge.
Supply only Chain link MS galvanised fencing any size or type weight n.exc 4 Kg per sqm complete all as specified and directed by Engineer in charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and directed by Engineer in charge.
Mild steel screw bolts( Machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long & dia meter of neck in mm n. exc 12mm complete all as specified and directed by Engineer in charge.
Galvanished, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanished mild wire staples or steel pins, etc as directed ( each line wire to be measured). complete all as specified and directed by Engineer in charge.
S&F including fabrication of MS framed work a in steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting , etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete FE-410-W(Gde-E-250) complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and Including rigid PVC conduit medium grade, concealed on wall portion and with stove enameled steel conduit medium grade on steel structural truse/ RCC roof ceiling portion surface type fixed with sadlles, screwes as per Engr practices of suitable size but not less than 20 mm bore with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed by Engineer in charge.
All as per item No-123 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch complete all as specified & directed by Engineer-in-charge.
All as per item No-123 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed by Engineer-in-charge.
All as per item No-123 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed by Engineer-in-charge.
All as per item No-123 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 123 to 127 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. complete all as specified and directed by Engineer in charge.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed by Engineer-in-charge.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed by Engineer-in-charge.
S&F for ceiling rose surface bakelite 50 x 25 mm size 3 terminals complete all as specified and directed by Engineer-in-charge.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed by Engineer-in-charge.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed by Engineer-in-charge.
Assembling & hanging ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed by Engineer-in-charge. Note :- Ceiling fan 1200 mm with blade 03 Nos, canopy 02 Nos, downrod, rubber real insulator & hanging clamp only shall be issued to the contractor free for fixing by the department under Sch 'B'
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed by Engineer-in-charge.
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed by Engineer-in-charge.
Supply & fix, outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed by Engineer-in-charge.
Supply & fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed by Engineer-in-charge.
S&F iron metal body heavy duty exhaust fan 300mm sweep, double ball bearing, copper wound, with louvers, 230 volts, 50 Hz, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directedby Engineer-in-charge.
Supply and fix ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed by Engineer-in-charge.
Supply only desert cooler electric driven (single phase), 230 volts, 50 Hz AC supply of having nominal air flow capacity of minimum 5000 CuM per hour (or nearest higher size) PVC Body with minimum 55 ltr capacity of water tank having exhaust fan kit 400 to 450 mm copper bound self supported with universal rolling wheel suitable for a bearing load of desert cooler to esay sifting with 3 core connection cord of size 2.5 sqmm coppler conductor of length minimum 2.0 Mtrs with molded 3 pin plug top of suitable capacity including speed control regulating switch, water circulating pump switch & water level indicator etc complete all as specified and directed by Engineer-in-charge.
Supply and fix electric water heater, storage type steel body with fiber glass coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser all as specified and directed by Engineer-in-charge.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. complete all as specified and directed by Engineer in charge.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed by Engineer-in-charge. .Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Supply and fix MCB DB 4 way sheet metal enclosure triple pole and neutral 415 volts with 100 Amp standard copper bus bar IP-43, IK-09 with metal doors of suitable size and common neutral link and earth bar all enclosed on standard steel sheet flush mouting type double door factory fabricated complete as per IEC 61439-3 without MCB but with enclosue blank plate complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement miniature circuit breaker (MCB) TPN 63 Amp, 4 poles, 415V 10KA 'C' curve current carrying capacity in the DB IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning., complete all as specified & directed by Engineer-in-charge.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed by Engineer in charge.
Supply and fixing MCB SPN 240V, 50 Hz, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer in charge.
Supply & fix MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified and directed by Engineer in charge by Engineer-in-charge.
Supply & fix MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit) complete all as specified and directed by Engineer in charge.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for equipment & power circuit) complete all as specified and directed by Engineer in charge.
M & L earthing complete in replacement with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 complete all as specified and directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable by Engineer-in-charge.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
Supply and fixing in replacement GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed by Engineer-in-charge.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed by Engineer-in-charge.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and as directed by Engineer-in-charge.
Supply and fix 'Medium Grade' galvanised iron tubes with all fittings such as tees bends elbow etc fixed on walls/ floors of 20 mm (3/4”) dia complete all as directed by Engineer-in-charge.
Supply and fix 'Medium Grade' galvanised iron tubes with all fittings such as tees bends elbow etc fixed on walls/ floors of 25 mm (1.0”) dia complete all as directed by Engineer-in-charge.
Supply and fix gun metal gate valve of size 20 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as directed by Engineer-in-charge by Engineer-in-charge.
Supply and fix gun metal gate valve of size 25 mm bore with iron wheel head screwed both ends for iron pipe and fixed of following sizes complete all as directed by Engineer-in-charge.
Supply and fix ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 20 mm bore complete all as directed by Engineer-in-charge.
Material and labour for Drilling and tapping cast iron water mains (in position) for branch connections of the internal 20 mm dia complete all as directed by Engineer-in-charge.
M&L for Straight plain brass ferrules (or connecting screws) screwed both ends and fixed Bore Diameter of pipe in 20 mm complete all as specified and directed by Engineer in charge.
Sree Ram Enterprises
saroj constructions
m/s Agra Builder
SahaDevSingh Constructions
m/s shanti consruction co
3Krishna Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .