Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.8 LAccepted-AOC NO 1 INSPECTOR QUARTERS TSP 6TH BATTALION CAMPUS NEW NATHAM ROAD MADURAI 625 014 | MADURAI | TAMIL NADU | 625001 | L1 | Accepted-AOC The lowest and negotiated tenderer | |
| 2 | L2₹91.8 L+₹457.96 (<0.01%)Rejected-AOC CHENNAI | CHENNAI | CHENNAI | TAMIL NADU | L2 | Rejected-AOC High rate tenderer | |
| 3 | L3₹99.7 L+₹7.9 L (8.62%)Rejected-AOC PLOT NO 1 510 NO 2 MADHA NAGAR KOVUR CHENNAI 600 128 | KANCHIPURAM | TAMIL NADU | 600128 | L3 | Rejected-AOC High rate tenderer |
Tender Value
Refer Docs
EMD Value
₹64,100
Closing Date
7 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer/CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Retrofitting, repairing and renovating the Madras Institute of Development Studies building at Adyar in Chennai city
2023_TNPHC_384132_1
SE/CC/DB/4789/2023
Open Tender
Civil Works
Lump-sum
180 days
Adyar in Chennai city
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹64,100
30 Nov 2023
31 Oct 2023
9 Nov 2023
31 Oct 2023
7 Nov 2023
31 Oct 2023
Amount
30) Finishing the top of flooring with cement concrete 1:3 (One of cement and three of blue granite chips of size 10mm and below) 20 mm thick Ellispattern Flooring (No Sand)
31) Weathering Course with concrete broken brick jelly 20mm gauge in pure burnt lime stone slaked and screened (No Sand)
40) Painting the new wood work with two coats of approved first class synthetic enamel ready mixed paint
45) Stucco Plastering 12mm thick using hard broken stone chips of size 3 to 10mm and below using 86.50 kgs of cement and 0.15 m3 blue metal chips for every 10m2 area over the existing plastered surface including curing etc.,
53.2) Supplying and fixing of C.I. manhole cover with locking arrangements of approved quality and brand of size 0.45mx0.45m (20 kg) as per standard specifications
238) Applying one coat of Anticorrosive treatment for steel grills
Annexure 3.2.3) Plain cement concrete 1:2:4 (One of cement two of crushed stone sand and four of Hard Broken Stone jelly) using 20mm gauge hard broken stone jelly
8.2.3.1) Providing and laying in position, Standardised concrete Mix M30 Grade Concrete b. In Ground floor
c. In First floor
d. In Second floor
e. In Third Floor
9.2.2) Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") a) In Ground Floor
b) In First Floor
c) In Second Floor
d) In Third Floor
10.2.2) Brick partition wall in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm thick (B.P.) b) In Ground Floor
c) In First Floor
d) In Second Floor
e) In Third Floor
14.3.2) Precast cupboard slab 40 mm thick using standardised concrete mix M30 b. In First floor
18.1) Providing form work and centring for reinforced cement concrete structure b.Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase waist, portico slab and other similar works
c.For Square and rectangular columns and small quantities such as sunshade, parapet cum drops window boxiing, fin projection and other similar works.
21.7.3) Supplying and fixing of solid core flush door shutter of thickness 35mm c) D - 1000mm x 2100mm (Single leaf)
29.9.1) Supplying and fixing of colour ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).
32.1.1) Finishing top of roof with one course of pressed tiles 23 x 23 x 2cm over a bed of C.M 1:3, 12mm thick mixed with water proof compound at 2% by weight of cement etc.
34.2.1) Plastering in C.M. 1:4, 12 mm thick
35.2.1) Special ceiling plastering in cement mortar 1:3, 10mm thick
43.2.1) Supplying, fabricating and placing in position of Mild steel Grills / Ribbed Tor Steels binding wire insulated with PVC
44.6.1) Supplying and fixing of following dia PVC SWR pipe with ISI mark confirming to IS 13952:1992- type 'A' for Rain water down fall pipe with (UPVC special clamp ) a) 110mm dia PVC SWR pipe
b)160mm dia PVC SWR pipe
50.3.2) Labour charges for removing the tree saplings / green grasses in terrace floor, water tank slabs, sunshades and side walls by cutting , removing and clearing the trees without affecting the adjacent structures and applying Reebaklens RR Fosrok chemical at dilution ratio 1:1 for avoiding future growth
52.1.1) Supplying, laying, fixing and jointing the following PVC pipes as per ASTM D - 1785 of schedule 40 of wall thickness not less than the specified in IS 4985 a) 32mm dia PVC pipe with necessary UPVC specials
b. 25mm dia PVC pipe with necessary UPVC specials
56.4.1) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade ' P' or "S' trap- Other than Ground floor.
58.3) Supplying and fixing the following dia PVC (SWR) pipe including all required PVC specials etc., all complete., a) 110mm dia PVC SWR pipe
b) 75mm dia PVC SWR pipe
77.5) Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7) Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
84.3) Run of main with 2 wires 4 sq.mm. PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark
93.1.1) Plastering with CM 1:3, 12mm thick with WPC (CICO)
207.3.1) Painting the false ceiling / walls with two coats of 1st class ready mixed plastic emulsion paint
207.3.2) Painting the old walls with two coats of surfex rain shield silicon enriched pure Acrylic emulsion paint of best approved quality colour and shade including thorough scrapping the old paint
207.4) Painting the old wood work with two coats of approved Ist class synthetic enamel paint including thorough scrapping
207.6) Painting the old iron work with two coats of ready mixed first class synthetic enamel paint including thorough scrapping the old paint
208) Removing the damaged A.C sheets in the places shown without affecting the purlins, rafters, joists etc
209.5.2) Clean removal of cement plaster from walls and racking out joints 20mm deep
213.1) Dismantling the damaged brick works in cement mortar in all floors without affecting the adjacent structures and clearing the debries 2km away from the site
216) Dismantling the damaged pressed tiles in cement mortar without affecting the adjacent structures in all floor
216.4) Supplying and providing petty iron works for Truss works like replacing the bolts, nuts, gusset plates , cleats and any other damaged portion of the truss
221) Removing the damaged broken door/window /ventilators including the removal of frames, hinges, fastenings and shutters from the existing structure and stacking the same carefully for reuse
224.1) Dismantling the existing damaged RCC with out affecting the adjacent structures
228.2) Labour charges for Chipping of concrete and roughening the old surface
229.2) Making Anchoring in the existing damaged R.C.C. works which has been cleaned by surface preparation and drilling 20 mm dia holes in the concrete columns/beams /slabs using electrically operated hammer drilling machine without much vibration
230.1) Providing anticorosive zinc painting priming for the existing exposed reinforcement in the R.C.C Structures by exposing
231.1) Applying Epoxy jointing compound for providing bonding to the new and old concrete for the damaged RCC repair area by mixing the base and hardener to the Epoxy jointing compound of approved make
232.3) Micro concreting for the damaged RCC BEAM works using sufficient quantity of micro concrete mix of approved make/quality
232.4) Reinforced cement concrete 1:1.5:3 (One of cement, one and half of sand and three of HBS chips jelly) for bracketing the damaged RCC columns in superstructure works
233.1) Pressure grouting by injecting plasticised expanding grout admixture of approved make
234.1) Repair of RCC isolated locations for the damaged RCC slabs beams and columns by applying a bonding coat of Polymer modified cementitious liquid of approved make
238.1) Applying one coat of Anticorrosive treatment for window grills
239.1.1) Removing the existing damaged IWC and dismantling the lime concrete without affecting the adjacent structures and removing the debris 2 km away from the site
239.2) Special curing immediately after removing the form work or after completion of the repair work , the surface should be sprayed with bonding polyester modified cementitious liquid with curing compound as per the ratio 1:1
239.3) Providing slurry tight form work which should not deform (or) leak due to pressure of micro concerete shall be fabrication and erected in position
242.2.2) Dismantling the damaged Floor finish and dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Cuddapah Slabs/shahabad flooring without affecting the adjacent structures in all floors including clearing debries 2km away from the site
254.2) Providing two legged scaffolding using 15cm diameter casurina props or best quality bamboo posts of 4m overall length a. 5.5m height in addition of 2.5m height
b. 8m height in addition of 2.5m height
c. 15.5m height in addition of 2.5m height
343.2.2) Supply and fixing of Galvanium Roof sheet of 0.47mm thick over MS purlin of approved ISI quality
532.3) Applying three coats of exterior grade cement based special wall putty to finish all the visible surfaces of the column
800) Drilling of 50mm dia 200 mm depth hole for inserting the 16mm dia longitudinal bar for columns
800.1) Drilling of 40mm dia hole to a depth of 80mm over the column surfaces after chipping the column surface and clean the hole and plugging the hole with chemical grout
800.2) Drilling of 30mm dia hole horizontally in the beam width wise to insert the 10mm beam stirrups and plugging the hole with chemical grout and bend the 10mm dia rod to form the beam stirrups
832.5.2) Supplying and fixing in position of UPVC window of casement type (open) for all sizes
832.5.3) Supplying and fixing in position of UPVC Ventilator louvered ventilator type for all sizes
961) Providing Galvanic anodes or sacrificial anode or galvanic cathodic protection system for protecting the metal structures from corrosion. Galvanic anodes anode units should be installed after placement of reinforcing steel.
961.6) Supply and applying Silicon Sealent for all round window gaps using sealant material
983.4) Providing Shear Connectors for providing composite action between the existing RCC slab and the newly added concrete layer.
A NARAYANAN
S.S. ENTERPRISES
Bidder Name
A NARAYANAN
M K SARAVANAN
S.S. ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_457779.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .