Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC 0 0 MOH SITARGANJ PIPRI POST UKHLI KATRA SHAHJAHANPUR UTTAR PRADESH 242301 SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242301 | SHAHJAHANPUR | UTTAR PRADESH | 242301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.5 L+₹35,375 (2.19%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.8 L+₹60,972 (3.77%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹18.7 L+₹2.5 L (15.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹19.5 L+₹3.4 L (20.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Aug 2023, 6:00 pmClosed
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Repair/replacement sewage lines cleaning drainage and culvert and repair manholes chamber soakage well desluding of septic tank, soakage well at depot area under GE Bharatpur
2023_MES_606942_1
8308/E8
Open Tender
Civil Works
Item Rate
270 days
Bharatpur
As per NIT
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹50,000
Yes
18 Sept 2023
30 Jun 2023
17 Aug 2023
30 Jun 2023
15 Aug 2023
2 Aug 2023
1 Jul 2023 - 19 Jul 2023
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1. 5 metre in depth; for foundation or for manholes not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
All as per item No. 1 above but exceeding 1.5 metre depth and not exceeding 3 metre in depth complete all as specified and directed by the Engineer-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers each not exceeding 25 cm depth in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
Removing surplus spoil to distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified and directed by the Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-Charge
Dismantling of cast iron pipe (soil waste & vent pipe ) of size 100 mm or less, jointed in CM and taking out of trenches & wall if required complete all as specified and as directed by Engineer-in-Charge. Note : Excavation & earthwork shall be measured and paid separately.
S&F cast iron soil, waste and vent pipe spun centrifugally cast iron of 100 mm bore as per IS 3989 , ISI marked in any length, with or without ears, with cement joints, laid in trenches or in floors etc all as directed by Engineer-in-Charge.
S&F cast iron soil, waste and vent pipe spun centrifugally cast iron of 100 mm bore as per IS 3989 , ISI marked in any length, without ears, with cement joints, fixed to wall including necessary clamps all as directed by Engineer-in-Charge.
S&F cast iron soil, waste and vent pipe spun centrifugally cast iron of 75 mm bore as per IS-3989, ISI marked, in any length, with of without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge.
S&F cast iron soil, waste and vent pipe spun centrifugally cast iron of 75 mm bore as per IS-3989, ISI marked, in any length, with of without ears, with cement joints, fixed to wall including necessary clamps all as directed by Engineer-in-Charge.
S&F in repair 100 mm dia cast iron cowls including taking down of old cowls complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 100 mm dia cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron bend of 100 mm bore with oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron bend of 100 mm bore with duck's foot or heel rest complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron bend of 75 mm bore with oval access door complete all as specified and as directed by Engineer-in-Charge.
S&F in repair cast iron bend of 75 mm bore with duck's foot or heel rest complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC PVC or Reinforced concrete pipe) set in cement mortar complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm dia Reinforced concrete pipe Class NP-2 with one collar per length joint with CM 1:1 with spun yarn and complete tested complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graged stone aggregate) as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-Charge.
Demolition of brickwork or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge.
Demotion of concrete of any description and in any position not otherwise specifically provided for,complete all as specified and as directed.
Brickwork with sub-class ‘B’(old size) burnt clay bricks straight or curved on plan exc 6 metre mean radius built in cement & sand mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L Rendering 10mm thick in cement and sand mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation, filling and mass concrete complete all as specified.
Plain Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channels, drains and inside the main hole complete all as specified and as directed by Engineer-in-Charge.
Extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms,moulds, mitered/stopped etc complete all as specified and as directed by Engineer-in-Charge. Note: Inner girth shall only be measured.
Add to or deduct for each 25 mm girth or part thereof over or under 30 cm ditto.
M&L for 75 mm thick cement concrete 1:3:6 Type C-2 (using 40 mm graged stone aggregate) as in plinth protection etc complete all as specified and as directed by Engr-in-charge.
Taking down cement or cement lime plaster of any description from brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
M&L Rendering 15 mm thick in cement and sand mortar 1:4 on other than faces of brick work or cement concrete or stone surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge
M&L for Rough Cast Plaster in two layers, under layer 10mm thick in CM 1:4 (1 cement : 4 coarse sand) on fair faces of brick work or concrete surfaces, furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1:1 (1 cement : 1 coarse sand : 1 stone chipping 6 to 12 mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified (payment for providing grooves shall be inclusive).
Supply only integral water proofing compound ISI Marked complete all as specified and as directed by Engineer-in-Charge.
Preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement based paint, white or tinted complete all as specified and as directed by Engineer-in-Charge
Demolition of stone slabs and tiles of any description or thickness in floor, appron etc laid dry or laid dry and pointed etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for 50 mm thick sand stone slab as mainhole cover complete all as specified and as directed by Engineer-in-Charge.
M&L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and forming benching as required for 150 mm dia pipe complete all as specified and as directed by Engineer-in-Charge.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the premises all as specified / directed.
M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of cement mortar 1:6, 15 mm thick complete all as specified and directed.
M&L for coloured glazed ceramic coloured tiles of size 300mm x 200mm x 7mm thick on vertical surface such as skirting dado etc including 10mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Taking up or down the existing unserviceable GI tubing and S&F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified and as directed by Engineer-in-Charge.
Taking up or down the existing unserviceable GI tubing and S&F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and as directed by Engineer-in-Charge.
S & F in repair PVC 10 ltrs , valveless, syphonic action type, flushing cistern, white, low level, with inlet, ball valve, float and handle, including 32 mm bore flush pipe brackets complete all as specified and as directed by Engineer-in-Charge.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm including complete all as specified and as directed by Engineer-in-Charge.
S&F in repair SS grating including jointing with cement of size 125 mm outlet weight not less than 50 gm for floor trape or Nahani trap complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous China squatting pan “Orissa” pattern, size 580x440mm, white, with integral foot rests and 'P' or 'S' trap (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor all as specified and as directed by Engineer-in-Charge. (Note: The disturbed surface of floor shall be made good as per existing specification without any extra cost to the Govt)
S&F in repair vitreous china wash down water closet pan (pedestal pattern) white, including all required fittings including Demolition of old existing unserviceable pedestal pattern western type WC complete all as specified and as directed by Engineer-in-Charge.
S & F in repair wash hand basin vitreous china, size 550mm x 400mm, white, flat back, including CI brackets, pillar tap fixed to 15mm bore pipe, long body fancy type cast copper alloy with capstan heads, chromium plated screwed down high pressure,with ot without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, CP waste fitting for waste pipe 32 mm dia with brass coupling, center hole CP grating including pinning in ends of brackets etc complete all as specified and as directed by Engineer-in-Charge.
Supply only plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S&F in repair Bib tap, cast copper alloy Chromium Plated fancy type/ long body with crutch or butterfly handle, screwed down, suitable for 15mm nominal bore iron pipe screwed for iron or brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 15mm bore Stop valves, fancy type chromium plared screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Pillar taps, fancy type, PTMT of any colour high pressure of 15 mm bore screwed for iron pipe and fixed, (Minimum weight 15mm-110gms), complete all as specified and directed.
S&F in repair cast iron nahani trap of size 75 mm dia of outlet with grating including jointing with wast pipe fixed in cement concrete 1:2:4 type B-1 using 20 mm graded curshed stone aggregate complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) pipe single socketed in any length fixed with suitable adhesives laid in trenches or in floor complete all as specified and as directed by Engineer-in-Charge.
Ditto all as per Srl item No 55here in before but fixed on wall complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC (SWR) bend for 110 mm bore pipe, any radius jointed with suitable adhesives complete all as specified and as directed by Engineer-in-Charge.
S&F for MS work for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay) conforming to Fe.290. Gde-E-165. complete all as specified and as directed by Engineer-in-Charge.
Disconnecting existing tanks of capacity exc 250 litres & n exc 500 litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc. complete all as specified and as directed by Engineer-in-Charge.
Dismantling & S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 litres, white colour, triple layered, hoisted and fixed in position all as specified in SSR Part I
Dismantling & S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 litres, white colour, triple layered, hoisted and fixed in position all as specified in SSR Part I
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed by Engineer-in-Charge.
S & F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet stip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube fixed in opening as per specification & drawing complete.
S & F of Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed type B-21 complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium, anodised, 150mm long barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F aluminium, anodised handle 150mm size cast type anodised complete all as specified and directed.
Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia 100mm including gully traps, grease traps etc.by removing all filtn/silt, foreign materials and other deposit whatsover competely and making the line free from all obstacles of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage line and repair the same if required including taking off and re-fixing manhole covers including testing the flow of sewar line evenly, smoothly by filling water and removing the silt/sludge in covered van/trolly outside the MD land complete all as specified and directed by Engineer-in-Charge.
Ditto all as per Srl Item No 67 here in before but size of sewage line 150 mm dia complete all as specified and directed by Engineer-in-Charge.
De-watering from septic tanks/soakage wells of any size and any depth by suitable pumps also removing all wastes, semi solid or liquid of any description to outside MOD land complete all as specified & directed.
De-sludging of manhole sludge (dry/wet), n exc. 1.50 m depth, individual manhole, desludging of septic tank & soakage well of any size, sludge removal manually including disposing of sludge by covered vehicle to a distance exc 500m but n.exc 3000 m & burried in excavated pit of adequate size including excavation and covering with earth from the existing septic tank of any depth, any capacity, in foul conditions, including taking & placing in position the manhole covers of any description, removal of sludge & solid contents to any place outside defence land and depositing where directed by Engineer-in-Charge.
De-sludging of manhole sludge (dry/wet) & septic tank and soakage well, exceeding 1.50 m depth, individual manhole, desludging of septik tank/soakage well of any size, sludge removal manually including disposingl of sludge in covered vehicle to a distance exc 500 m but n.exc 3000 m & burried in excavated pit of adequate size including excavation and covering with earth from the existing septic tank of any depth, any capacity, in foul conditions, including taking & placing in position the manhole covers of any description, removal of sludge & solid contents to any place outside defence land and depositing where directed by Engineer-in-Charge.
Cleaning/removing blockage of WC, bath, kitchen, WHB, EWC, IWC, Gully Trap, includding P or S Traps, of any description, by rodding, by pressure pumps of any description etc by removing all sludge, foreign materials and other deposits whatsoever completely (working in foul condition with taking precautionary measures equipments as required or applicable and working on all working days including sunday ) all as specified and directed
Provn of 10 users septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete as per TD DRG NO-CEJZ/2002/TD/S-2
Provn of Sokage well, excavation in ordinary soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-25 concrete, including intercepting chamber, screen chamber brick work in CM 1:6, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 meter dia and 3.0 meter effective depth complete as per TD DRG NO- CEJZ/2004/TD/S-35
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brick work, masonry, etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed by Engineer-in-Charge.
Dismantling fencing wire mesh, any type complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes each n. exc .50 cum, getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good disturb surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation of posts and struts, foundation, filling and mass concrete etc.complete all as specified and directed by Engr-in-charge.
S&F Mild steel work of Fe-290 Gde E-165 as in angle iron fencing posts and struts & flat iron,round bar, drilled and countersunk for boulders running bars, including embedding in concrete and securing etc post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc. flat iron fillets (for securing wire mash etc.) including all necessary drilling, bolting or riveling etc. complete all as specified and directed by Engr-in-charge.
Supply only Chain link MS galvanised fencing of any size & nominal dia of mesh wire not less than 3mm complete all as specified and as directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provission of binding wire. complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Mild steel screw bolts (machine made) of 10mm dia and 50mm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed by Engr-in-charge.
S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Material and Labour preparation of new steel and iron surface of any description and applying 2 coats of syntheltic enamel paint over a coat of red oxide primer complete all as specified.
Surfaces of any description, n. exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and as directed by Engineer-in-Charge.
M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate in kerb stone ,window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts,boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM(1:4) with joints to match etc. complete all as specified and as directed by Engineer-in-Charge
M&L for broken stone or boulders in hardcore of gauge exc 40mm but n exc 63 mm deposited spread and levelled in layers n. exc 15 cm thick watered and rolled/rammed to a true surface complete all as specified and as directed by Engineer-in-Charge
M&L for 100 mm thick Cement concrete type D-2, 1 : 4 : 8 (40mm graded aggregate) as in sub floors/sub bases etc. complete all as specified and as directed by Engineer-in-Charge
M&L 80 mm thick Machine pressed precast concrete interlocking paver block with grey cement and no pigment of shape and size as approved by GE confirming to IS 15658-2006, M-40 Grade over 25mm thick sand cushion complete all as specified and directed by Engineer In-charge Note- The cost of sand cushion of shall be deemed to be inclusive in quoted rate
M& L for 80 mm thick Machine pressed precast concrete interlocking paver block with M-40 grade of shape and size as approved by GE conforming to IS 15658-2006 with grey cement and colour pigment over 25mm thick sand cushion complete all as specified and directed by Engineer In-charge Note- The cost of sand cushion of shall be deemed to be inclusive in quoted rate
M&L for Stone kerb (Sand Stone) of roughly squared stones of size 5cm x 30cm and not less than 45cm in length, dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and stuck flush complete all as specified and as directed by Engineer-in-Charge
M&L for 150 mm thick Cement concrete type B-2, 1 : 2 : 4 (40mm graded aggregate) as in floors, pavings etc. complete all as specified and as directed by Engineer-in-Charge
M/s Ranaji Construction Co
M/S VAIBHAV ENTERPRISES
M/S MAMTA CONSTRUCTIONS
B R ENTERPRISES
PD GUPTA AND COMPANY
abhinav and company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .