Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.7 LAccepted-AOC OFFICE NO 2 GROUND FLOOR CO OP HSG SOCIETY SBS ROAD COLABA MARKET MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹72.4 L+₹1.5 L (2.13%)Rejected-Finance B 13 ROOM NO 2 2 SHIVA PALM BEACH SOCIETY SECTOR4 NERUL WEST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹72.4 L+₹1.5 L (2.16%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹74.8 L+₹3.9 L (5.55%)Rejected-Finance ROOM NO 214 GANESH MURTHY NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹76.5 L+₹5.6 L (7.96%)Rejected-Finance A 303 SHREE KRISHNA COMPLEX CO OP HSG SOC LTD WESTERN EXPRESS HIGHWAY OPP NATIONAL PARK BORIVALI E MUMBAI 400066 | MUMBAI SUBURBAN | MAHARASHTRA | 400066 | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹90 L
EMD Value
₹1.6 L
Closing Date
7 Oct 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIRS TO P 15 BUILDING OF NAMAC AT INS KUNJALI, MUMBAI UNDER GE (NW) KUNJALI, COLABA, MUMBAI
2024_MES_670527_1
8408/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Kunjali
Class C
Category a (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹1.6 L
Yes
28 Nov 2024
3 Sept 2024
9 Oct 2024
3 Sept 2024
7 Oct 2024
24 Sept 2024
3 Sept 2024 - 21 Sept 2024
Amount
Material and labour for erecting at site self supported steel H- Frame Scaffolding only for structural repairs of column with micro concrete or columns jacketing with cross bracings of good quality without dents and corrosion to reach place of work including approaches, extension, working platform ladders, lifting tackle necessary wall anchors for men and materials till completion of all structural repair items of work and curing period etc. complete. The work should be carried out with all the safety belt and adequate labours insurance under the supervision of qualified supervisor this item should be used only for structural repair work for entire period of building. (Payment should be only once irrespective of duration of scaffolding) etc complete all as specified and directed. (Rate included shall be inclusive of
Material and labour for form work and fixing 6mm thick plywood covering panels in pattern upto 30m height as per the directions of Engineer-in-charge with necessary backing framework to shield windows etc. from falling debris and removing and taking away the material after completion of work (the covering material will be the property of contractor after completion of work) including making good any incidental damage(s) to the existing building or its finishes etc complete. (the measurements for payment shall be made in terms of the area protected by such covering). Only one weightage will be given for covering windows till finishing irrespective of time-period of protection. Note- Ply wood panels shall be removed by the contractor and shall become the property of the contractor after completion of the work rate shall be inclusive of credit of plywood panels after completion of the work.
Material and labour for erecting external safety Net or opening 75x75 in addition vertical fisher net arrester on the first floor or vertically throughout to prevent debries failling while execution of work to hold / absorb the debries stone impact and during the entire period of work. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisior and removing after completion after complete work. etc. complete. Note- Safety Net shall be removed by the contractor and shall become the property of the contractor after completion of the work, rate shall be inclusive of credit of safety net after completion of the work.
Material and labour for erecting, maintaining and removing temporary protective screens made out of specified fabric upto 30m height with all necessary fixing arrangement (or same as Nylon safety net as above) including necessary beading of thread & including G.I. rings to ensure that it remains in good serviceable condition & position for the work duration as required by Engineer in charge. (a) Woven PVC / HDPE Cloth. Note: Payment shall be made for actual flat area of wall and for once only irrespective of the time period. Torn or damaged cloth has to be replaced immediately during execution & nothing extra shall be paid to agency on this a/c. The cloth will be the property of agency after completion of work & must be removed from the premises after completion of work as per direction of Engineer-in-charge.
Material and labour for carefully tapping with light hammer the hollowness / De-bonded plaster and chipping the same with chisel after demarking and cutting the boundary grooves by electric cutting machine including removal of debris.
Material and labour for breaking carefully the loose concrete of distressed member without damaging existing strong concrete by means of sharp chisel which should tempered regularly of high frequency low impact hammer is used, cleaning the surface by water jet pressure pump at 4 to 5 kg/ sq.cm pressure to remove chlorides and loose partials, air drying the surface etc. The work should be carried out with all the safety measures like helmet, safety belt and adequate labor insurance under the supervision of qualified supervisor. (The damaged ceiling / concrete will be measured) etc completion of work as per direction of Engineer-in-charge. Note- Rate shall be inclusive of complete removal of debris and no extra cost to govt.
Material and labour for erecting steel tubular props of required height up to 14' feet, L head or flat head braced at center and supporting a continuous 2"X 3" wooden runner , resting on wedge and block minimum capacity 3 Ton to support the structure provisionally during repair and jacketing etc. and maintain them in position till required item etc. complete. The props are erected in perfect vertical in plumb taking /transferring the load equally/ uniformly. The location of every prop should be one over another floor and it should not be eccentric. The tightening of every prop should be uniform to all props to strain the building uniformly, removing the same as and when directed by structural engineer/ site Engineer. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor and remove the same completion of work etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced) in roofs, floors (other than ground floors), beams, staircases. Landing, chajjas and similar suspended work including disposal of unserviceable material within premises at a suitable stacking location at ground level including all lead & lifts as per direction of engineer-in-charge without disturbing the otherstructural elements.
Demolishing RCC work i/c pardis, roofs, floors, beams, staircase, landing, chajjas & wall manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within premises at a suitable stacking location at ground level including all lead & lifts as per direction of Engineer-in-charge without disturbing the other structural elements such as column, beams & slab.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposing off complete all as specified and as directed.
M & L for cleaning the existing reinforcement with hammer tapping and wire Brush/ rotary wire brush, fixed to hand drill machine, making the surfaces free form loose corrosion material, dirt scaling etc. complete. Applying two coats of polymer based alkaline rust converting primer confirming to ASTM-B 117 by means of paint brush, liberally all over in two coats of 1 hour between the costs, The product should converts the rust in to stable organo metallic complex molecule layer, this should also act as primer to further treatment of steel etc. complete. The work should be carried out with all the safety belt and adequate labour insurance under the supervision of qualified supervisor. (the damage celling/ concrete al be measured) etc. complete all as specified and as directed.
M & L for anticorrosive treatment to Reinforcement application of two coats of IPNETRB (CBRI known how) on expose reinforcement in two coats with time interval) of minimum 4 hours between each coat. The application shall be by brush, application is allowed to dry for further treatment. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (the damage ceiling / concrete all be measured) etc. complete all as specified and as directed.
Material and labour for applying two coats of concrete penetrating hi- tech corrosion inhibition mechanism inhibits corrosion of steel in concrete at the poles, cathode & anodic simultaneously on concrete surface which is prepared earlier. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor. (The damage ceiling/ concrete all be measured) etc. complete all as specified and as directed.
Material and labour for formwork to sides and soffits of floor , roof beams, pillars, posts struts, piers, columns and stanchions etc also splays between floors and beams, etc. rough finished surfaces of concrete complete all as specified and as directed.
Replacing distressed / loose/ cracked/ porous carbonated, loose part of concrete and repairing the damaged surface of concrete , fix the form work/ structural element, pour the free flow ready mix micro concrete mix with 5 1t to 7 1t of water in the form work. Micro concrete should be mixed in steel tray homogeneously makeup concrete is based on types of structural element and its location. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc. complete all as specified and as directed.
Material and labour for applying 15 mm thick polymer mortar to load carrying R.C.C member in two layers in proportion of 1:5:15 by weight polymer of approved quality and make, cement and wash quartz sand with required W.C. ratio for desired floating, curing after initial setting time etc. complete all as specified and as directed.
Making up lost section of concrete / mortar with thixotropic repair mortar is one component thixotropic dual shrinkage compensated fiber reinforcement formulation for structural members. Build up section by hand packing as per manufacturers specification, applied by mean of hand glouse by expert applicator, the rehabilated surface should be free from air gaps, voids should be in line with existing required line and line with existing surface, including curing, cleaning the area etc. complete. The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc. complete all as specified and as directed.
Material and labour for Fixing Shear connectors of 8mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 12mm diameter to a minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment complete all as specified and as directed.
Material & Labour mild steel TMT bars (500D/550D) 10 mm dia and over, cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
Material and labour for applying approved epoxy resin EPI Bond of before polymer plaster/ concrete to have the perfect bond between old concrete and new concrete/ polymer plaster surface confirming to ASTM-C- 882-87 using nylon brushes scaffolding labour etc. complete all as specified and as directed.
Material and labour for applying priming cum bonding coat of polymer of approved make and quality as approved by engineer- in - charge and cement slurry in 1:1 proportionate by weight to concrete area by brush or any other established method etc. complete all as specified and as directed.
Material and labour for Drilling and fixing Teflon perforated nozzles in RCC member, including drilling 14 mm dia. 50 to 100mm deep holes in structural members at in cle the intervals of 600 mm in staggared manner of as directed by the consultants in RCC structural elements. Clean the holes by air blower prior to fixing nozzles. fixing of nozzels in cleaned holes. external end of nozzles to be machined to receive outlet of grouting gun. nozzel is fixed by means of epoxy by means of epoxy sealent to ensure complete sealing . cure the system for min. 12 hours. the work should be be carried out with all the safety measures like like helmet, safety belt and adequate labour insurance under the supervision of qualifed supervisor. etc .complete all as specified and as directed. Note- Work shall be executed through authorised applicator only.
Material and labour for Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that achieves compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm. till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of Material, Manpower and Equipment. Note- Work shall be executed through authorised applicator only.
Material and labour for Injecting high performance non shrink, free from high strength antiwash Polymer Cement Grout by addition of water as per manufacturers specification into hoeycombing area/ porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 kg/cm2 and subsequently cutting/ removal of nipples and sealing of holes with epoxy putty EPW 1010 etc. complete as directed by Engineer-in-charge.
Drilling and fixing 8mm,10mm and 12mm re-bars with 'Fischer/Hilti' system and chemical, etc. Steel to be paid seperately
12mm dia bars
10mm dia bars
8mm dia bars
Removing existing water proofing treatment such as I.P.S./Brick bat coba etc. from terrace/toilet sunken portion without damage to structure, levelling and cleaning the surface for providing new specialised water proofing treatment complete.
Material & Labour PCC 1:2:4 type B-0 (using 12.50 mm graded aggregate) cement concrete as a leveling course on roof surfaces and coping etc.
Material & Labour for applying a coat of bituminous primer 0.25 Kg/Sqm on prepared surface of plaster as per manufacturer's instructions, manufactured by the same agency of APP membrane. After applying of bituminous primer applying evenly a coat of bitumen 85/25 at the rate of 1.2 kg per sqm incl cleaning surfaces. Providing and laying five layered 4 mm thick APP (Atatic poly propylele) modified polyester reinforced water proofing membrane with minimum weight of 4.60 Kg/Sqm, as specified here-in-after. The APP membrane shall be laid using torch on application with minimum 100 mm side overlap and 150 mm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. The APP membrane shall be taken upto minimum 200 mm on vertial surfaces. The edge of the membrane shall be sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet . over the APP membrane provide a polypropylene/polyester, non woven geotextile fabric of 150 gram/Sqm complete all as specified and directed.. Notes :- (i) Irrespective of lap the net covered area shall only be measured and paid (ii) The quoted rate shall be deemed to be inclusive of bituminous primer and a coat of bitumen 85/25 at the rate of 1.2 Kg per Sqm for APP membrane complete all as specified and directed by Engineer-in-Charge. Note- Work shall be executed through authorised applicator only.
Removing of bldg materials exc 5 KM but not exc15.00 KM and depositing, complete all as specified and directed
Material & Labour brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including all necessary scaffolding as required and rubbishing off the premises etc complete all as specified and as directed..
Providing 20 mm external cement plaster in two coats under layer 12 mm thick cement plaster 1:4 (1 cement : 4 coarse sand) and a top layer 8 mm thick cement plaster 1:4 (1 cement : 4 coarse sand) finished rough with sponge. (Payment under this item shall be made only after proper curing has been done minimum for three days and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument) - Cement Sand mortar in proportion of 1:4 (1-cement: 4- graded coarse sand) with polymer admixed in proportions approved by Engineer-in-charge.
Material & Labour rendering 15mm thick in CM 1:6 on brick surfaces, finished even and smooth without using extra cement on walls complete all as specified and as directed.
Material & Labour rendering 10mm thick in CM 1:3 on concete surfaces as in ceiling finished even & smooth without using extra cement in ceiling.
Material & Labour applying two coats of acrylic water/weather proof exterior coating over a coat of primer all as per manufactures instruction.
Supply only integral water proofing compound.
Material & Labour for applying two coats of oil bound distemper over newly plastered/ putty surfaces of wall all as specified and directed.
Material & Labour for preparation of newly plastered surfaces of ceiling and applying two coat of oil emulsion distemper complete all as specified and directed.
Complete removal of existing treatment on wall surfaces by scrapping, washing & rubbing down with water and applying two coats of oil bound distemper over a coat Chalk whiting, on plastered surfaces,
Material & Labour for preparation of old decorated surfaces of wall and applying one coat of oil emulsion distemper all as specified and directed
Material & Labour for applying 1 to 2 mm thick wall care putty for making the surface even & smooth all as specified and directed by the Engineer-in-Charge.
Material & Labour for preparation of old decorated surfaces of ceiling and applying one coat of oil emulsion distemper complete all as specified and directed.
Material & Labour for POP false ceiling using 600X900x12 mm thick plaster of paris with gypsum binder sheet decorative type including two coats of plastic emulsion paint and necessary provision for concealed type light fittings, fixed on 22 gauge GI channel grid work, main joist of size 50x25 mm spaced at 750 mm centre, secondary joist of size 75X20 mm fixed to main joists spaced at 900mm, suspended to roof members using 25x25x2 mm GI angles and fasteners @ 1.2 M C/C, including dismantling old un serviceable false ceiling, complete all as specified and directed.
Dismantling stone slab and tiles of of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc all as specified and directed.
Material & Labour 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
Rounding to edges of stone slabs on edge, such as in steps, cooking platform and making grooves for lining and other similar work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land
Supply & Fixing 160mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with ms clamps all as specified and directed.
Supply & Fixing 160mm dia bore PVC (SWR) bends any radius
Material & Labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate ) as in plinth protection and similar works 75mm thick finished fair and smooth without using extra cement complete.
Supply & Fixing in repair powder coated aluminium (minimum 25 micron thickness of coating) of various section as required for doors, sliding windows/ partion/Ventilator etc including fixing and making the frames for hinges glass/wire gauge etc. Complete incl all fittings like rubber beading, clips locking arrangement,in sliding shutter, sealant etc all as specified and as directed by Engr- in- charge.
Supply & Fixing in repair aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by all as specified and as directed by Engr- in- charge.
Supply & Fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel stapple etc.
Supply & Fixing 12mm thick prelaminated medium density particle board,interior grade, prelaminated both side with decorative choice lamination fixed with screws to aluminium frame work complete all as specified and directed.
Supply & Fixing 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified.
Supply & Fixing for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed.
Supply & Fixing for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed.
Supply & Fixing 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified.
Supply & Fixing Stainless steel butt hinges 100 mm.
Dismantling plain or corrugated steel/AC roof sheets any gauge, thickness, including Nainital or similar pattern roof covering all as specified and directed.
Supply & Fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified.
Supply & Fixing pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
Supply & Fixing steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS -1161 1979 grade St-240
Material & Labour for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
Demolition and breaking up drain pipes salt glazed ware, reinforced cement concrete) set in cement mortar 100 mm
Supply & Fixing 110mm bore PVC (SWR) pipes single socketed in any length wirh rubber ring joints fixed to walls.
Supply & Fixing 75 mm bore PVC (SWR) pipes single socketed in any length wirh rubber ring joints fixed to walls.
Supply & Fixing PVC (SWR) bends 110 mm, with inspection door (any angle), conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply & Fixing PVC (SWR) bends 75 mm, with inspection door (any angle), conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply & Fixing PVC (SWR) branch piece 110 mm single Y, conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply & Fixing PVC (SWR) branch piece 75 mm single Y, conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply & Fixing PVC (SWR) vent cowl 110 mm conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Supply & Fixing PVC (SWR) vent cowl 75 mm conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Material & Labour in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement75 mm dia.
Taking up or down existing GI water tubing complete with all fittings of 15 mm bore
Taking up or down existing GI water tubing complete with all fittings of 20 mm bore
Supply & Fixing GI tubing medium grade with all fittings like Tee, bend, elbow etc, 15 mm bore fixed to walls or ceilings with saddles/spacers complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing GI tubing medium grade with all fittings like Tee, bend, elbow etc, 20 mm bore fixed to walls or ceilings with saddles/spacers complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc 15 mm bore pipe
Supply & Fixing UPVC pipes of pressure rating 10 Kgf/cm2 fixed complete to walls, celing etc or in floors etc 20 mm bore pipe
Supply & Fixing PVC connections 15 mm size with PTMT nuts of length 600mm
Supply & Fixing in repairs Vitreous China wash down water closet pan ( pedestal pattern) , white (excluding fixing bolts, flushing cistern and flush pipe) fixed in repairs
Supply & Fixing in repairs, Plastic water closet seat, black or white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S/F in repairs PVC valveless syphonic action type ,flushing cistern Low level white, with inlet ball valve ,float and handle 10 Ltr capacity including brackets.
Supply & Fixing in repairs Flush pipe of Polyethylene of low or high density or PVC 32 mm dia. for low level cistern
Supply & Fixing in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Supply & Fixing in repair wash hand basin vitreous china white (flat back) of size 550x400mm including bracket 15mm dia 32mm dia waste coupling and 32mm dia PVC waste pipe 90cm long etc. complete all as specified,
Supply & Fixing in repairs fancy type CP Pillar taps 15 mm dia, cast copper alloy , with capstan heads, screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for iron pipe and fixed .
Supply & Fixing in repairs fancy type CP bib cock 15 mm dia, screwed for iron pipe and fixed.
Supply & Fixing in repairs fancy type two way CP bib cock 15 mm dia, screwed for iron pipe and fixed.
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, fan regulators, ceiling roses, lamp holders, brackets, removing material to store for keeping in safe custody and making good to disturbed surfaces as directed by Engineer-in-Charge
M&L point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly including required nos and size of modular box with cover plate frame in any module all as specified.Notes: a) Colour coding shall be followed as given below:- i) Phase - Red ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit.
One light/fan point controlled by one 5A switch
One 5A switch socket combination on the same board
One 5A switch socket point on independent board
M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete for One 5 pin, 15A switch socket combination on the independent board including modular box and cover plate at required numbers and size complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately Finolex
S & F ceiling rose surface bakelite 65 x 50mm, flush type, 3 terminals complete all as specified and directed by EIC.
S & F modular switch 1 way 6A,1 module all as specified and directed by EIC.
S & F modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed by EIC.
S & F modular socket 6/16A,2/3 pin, combined 2 module all as specified and directed by EIC.
S & F modular switch 1 way 16A,1 module all as specified and directed by EIC.
Supply and fixing in repair new generation recessed mounted ultra slim panel LED 2X2 Luminaire 36 watt, min 100 lumen /watt and CRCA powder coated body and high translucent diffuser provides high quality ecomonic energy saving lighting to modern offices. Suitable for 600 x 600 mm modular/POP/Gypsum ceiling.
S & F in repirs LED light fitting 1x20W (min 100 lumen /watt), 230 V, 4 feet surface monted, indoor decorative aluminium extruded T- 5 LED batten, integrated type etc complete with all accessories internally pre-wired and including fixing the fitting on wall/ceiling with suitable PVC round block-02 Nos including connecting up with twin core twisted flexible copper conductor cable with suitable size and all as directed by Engr-in-Charge.
S&F in repair of double door type SPN DB 08 Way ,240V with 100A copper busbar each phase , double door type IP-54 IK 09 protection suitable for housing MCB's all as specified and directed by EIC. Make: Legrand cat No 507641 /Seimens/GE. Note : MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S & F MCB SP 0.5 to 32 Amps,10KA, 'C' series 240V complete all as specified and directed.
S & F MCB SPN 63 Amps,10KA 'C' series 240V complete all as specified and directed.
Taking down Submain wiring any size and any run complete and making good the distrubed surface matching with existing surface all as directrd by Engineer-in-Charge.
M&L for sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6.0sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Taking carefully ceiling fans by disconnectig electric connections, fan blades, etc put in safe custody for repair under relvant items of schedule Note:- The cost of required T & P, flat form lader shall be included in the quoted rates.
Repair and re-fixing, re-assembling the existing celing fan in same original position along with cable after rectification of defects such as apply the one coat varinsh for windings, painting fan blades, changing fan bearning, rewinding of fan, write MES no on fan blades including nut, bolts and washers complete all as specified and as directed by Engineer-in-Charge.
S&F for modular fan step regulator, 120W - 2 modular all as specified and directed by EIC.
Supply of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 32 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF ECO SAFE compound shall be supplied in 50 Pound Bag. ( 1 Bag required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set incl Supply of Eco Friendly weather proof High Density Polyethylene Earth Pit Chamber Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Anil Industrial Corporation (BID ID -3121991)
SHREE JAGDISH FURNITURE CO. (BID ID -3120481)
Pragathi Infrastructure Co. (BID ID -3131054)
Nilesh Construction (BID ID -3129966)
AGRAWAL ASSOCIATES (BID ID -3122027)
Bob Enterprises (BID ID -3121147)
satguruenterprises (BID ID -3122235)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .