Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC VILL GHARGA PO DWARNARI DIST PURBA BARDHAMAN PIN 713403 WB | PURBA BARDHAMAN | WEST BENGAL | 713403 | L1 | Accepted-AOC BEING L1 BID | |
| 2 | L2₹26.5 L+₹8,559 (0.32%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Being L2 Bid | |
| 3 | L3₹26.7 L+₹24,994.94 (0.94%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bid | |
| 4 | L4₹29.5 L+₹3.0 L (11.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 Bid | |
| 5 | L5₹30.8 L+₹4.4 L (16.5%)Rejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L5 | Rejected-Finance Being L5 Bid |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
27 Mar 2024, 6:00 pmClosed
GE I CG N Kolkata
GE I Coast Guard Navy Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings Kolkata 23
REPLACEMENT OF LT /HT PANEL AT HALDIA UNDER GE I CG N KOLKATA
2024_MES_643363_2
NIT No 8701/56/2023-2024/ 04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Haldia
Class D Category b i
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹64,000
Yes
29 Jun 2024
8 Mar 2024
30 Mar 2024
8 Mar 2024
27 Mar 2024
22 Mar 2024
Amount
Supply install commissioning and testing floor mounted indoor cubical type LT panel board (CPRI tested) IP 54 protection, fabricated out of 3 mm thick CRCA Sheet of size not less than 1600 mm x 2000 mm x 600 mm and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exit from bottom with cable glands and gaskets, copper bus bar of suitable size shall be fixed on porcelain insulator with internal control wiring with suitable size of cuppor stripsor cu single core cable to for incoming and outgoing connection of all switches/ MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/ tapes and to be connected with aluminium lugs, including two coats of powder coated spray paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) 630 Amp Changeover 4 Pole, 415 V - 01 No. (ii) 630 Amps MCCB 4P with Microprocessor release 630 Amps with breaking capacity 50 KA - 01 Nos OUTGOING :- (i) 250 Amp MCCB 4 pole 36 KA - 03 No. (ii) 160 Amp MCCB 4 pole 36 KA - 04 No. (iv) 100 Amp MCCB 4 pole 36 KA - 02 No. (ii) 63Amp MCCB 4 pole 36 KA - 03 No. (iii) 6-32 Amp MCB SPN pole - 03 No (iv) Bus bar 950 Amp 4 way. (vii) Digital type Ameter , range 0 to 600 Amp with slector switch and CT -01No (viii)Digital type Volt meter, range 0 to 500 Volt with slector switch and PT-01No (ix) Time switches 415 V three Phase of 20 Amp rating with contactor (x) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel at Vikram enclave substation and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canopy type LT Feeder Pillar Box(CPRI tested) IP 54 protection, fabricated out of 3 mm thick CRCA Sheet with size not less than 1500 mm x 1200 mm x 600 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar o fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) 250 Amp MCCB 4 Pole with Microprocessor release , 415 V 36 KA - 01 No. OUTGOING :- (i) 160 Amp MCCB 4 pole 36 KA - 02 No. (ii) 100 Amp MCCB 4 pole 16 KA - 02 No. (ii) 63Amp MCCB 4 pole 36 KA - 02 No. (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 400 Amp 4 way. (vii) Digital type Ameter , range 0 to 400 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) time switches 415 V three Phase of 20 Amp rating with contactor. (x) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canopy type LT Feeder Pillar Box(CPRI tested) fabricated out of 3 mm thick CRCA Sheet of size not less than 1500 mm x 1200 mm x 600 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) 250 Amp MCCB 4 Pole with Microprocessor release , 415 V 36 KA - 01 No. OUTGOING :- (i) 160 Amp MCCB 4 pole 36 KA - 01 No. (ii) 100 Amp MCCB 4 pole 36 KA - 2 No. (ii) 63Amp MCCB 4 pole 36 KA - 02 No. (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 400 Amp 4 way. (vii) Digital type Ameter , range 0 to 400 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canopy type LT Feeder Pillar Box(CPRI tested) IP 54 protection, fabricated out of 3 mm thick CRCA Sheet of size not less than 1500 mm x 1200 mm x 600 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 Pole, 415 V, with Microprocessor release 400 Amps with breaking capacity 36 KA -01 Nos OUTGOING :- (i) 160 Amp MCCB 4 pole 36 KA - 03 No. (ii) 100 Amp MCCB 4 pole 36 KA - 2 No. (ii) 63Amp MCCB 4 pole 36 KA - 02 No. (iii) 6-32 Amp MCB SPN pole - 03 No (iv) Copper Bus bar 600 Amp 4 way. (vii) Digital type Ameter , range 0 to 400 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canoopy type LT Feeder pillar box(CPRI tested) IP 54 protection, fabricated out of 3 mm thick CRCA Sheet of size not less than 1300 mm x 1000 mm x 550 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 Pole, 415 V, with Microprocessor release 250 Amps with breaking capacity 36 KA -01Nos OUTGOING :- (i) 200 Amp MCCB 4 pole 36 KA - 01 No. (i) 100 Amp MCCB 4 pole 36 KA - 02 No. (ii) 32 Amp Industrial socket 5 pins - 02 No. (iii) 6-32Amp MCB SPN pole - 03 No (iv) Copper Bus bar 400 Amp 4 way. (vii) Digital type Ameter , range 0 to 300 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canopy type LT Feeder Pillar Box (CPRI tested) IP 54 Protection fabricated out of 3 mm thick CRCA Sheet of size not less than 1200 mm x 1000 mm x 550 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of powder coated spray paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA -01 Nos OUTGOING :- (i) 100 Amp MCCB 4 pole 36 KA - 01 No. (ii) 63Amp MCCB 4 pole 36 KA - 03 No. (ii) 32 Amps industrial socket 3 Phase 5 pin - 03 Nos (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 250 Amp 4 way. (vii) Digital type Ameter , range 0 to 200 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted outdoor cubical canopy type LT Feeder pillar box (CPRI tested) IP 54 protection fabricated out of 3 mm thick CRCA Sheet of size not less than 1200 mm x 1000 mm x 550 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 pole, 415 Volt, with microprocessor release, 160 Amps with breaking capacity 36 kA - 01 No. OUTGOING :- (i) 100 Amp MCCB 4 pole 16 KA - 01 No. (ii) 63Amp MCCB 4 pole 36 KA - 02 No. (iii) 32 Amps industrial socket 3 phase 5 pin - 02 Nos (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 350 Amp 4 way. (vii) Digital type Ameter , range 0 to 200 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor mounted indoor cubical canopy type LT panel board (CPRI tested) IP 54 protection, fabricated out of 3 mm thick CRCA Sheet of size not less than 1500 mm x 1200 mm x 550 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of powder coated spray paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA -01 Nos OUTGOING :- (i) 100 Amp MCCB 4 pole 36 KA - 01 No. (ii) 63Amp MCCB 4 pole 36 KA - 02 No. (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 350 Amp 4 way. (vii) Digital type Ameter , range 0 to 200 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set (x) Star Delta Starter for 20 HP Pump - 02 Nos (xi) Star Delta Starter for 7.5 HP Pump - 01 Nos (x) Single phase preventor - 3 Nos Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply install commissioning and testing floor/ wall mounted indoor cubical type LT panel board (CPRI tested) IP 54 protection fabricated out of 3 mm thick CRCA Sheet of size not less than 1400 mm x 1000 mm x 550 mm and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, copper bus bar fixed on porcelain insulator with internal control wiring with suitable size of copper strips or cu single core cable to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with aluminium lugs, including two coats of powder coated spray paint on the surface externally & internally over a coat of red oxide primer paint including necessary foundation in Cement concrete, 1:2:4 type B-2 using 20 mm crushed stone agreegate complete all as specified and as directed comprising of the following :- INCOMER :- (i) MCCB 4 Pole, 415 V, with Microprocessor release 125 Amps with breaking capacity 36 KA -01 Nos OUTGOING :- (i) 63 Amp MCCB 4 pole 36 KA - 01 No. (ii) 40 Amp MCCB 4 pole 25 KA with DOL upto 5 HP - 05 No. (iii) 6-32Amp MCB SPN pole - 03 No (iv) Bus bar 200 Amp 4 way. (vii) Digital type Ameter , range 0 to 200 Amp with slector switch and CT -01No (viii) Digital type Volt meter, range 0 to 500 Volt with slector switch -01No (ix) Indicator lamp RYB-01 set (ix) Single phase preventor -05 set Note :- Taking down the old unserviceable LT Panel and depositing to the store yard of AGE B/R Haldia shall be included in the quoted rate.)
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc including taking down old unserviceable cable complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point coplete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply & laying unreinforced precast concrete cable cover class LV type 1, flat shape, dimension 250 mm X 150 mm X 40 mm as per IS 5820: 1970 complete all as specified and directed.
Material and labour for boring of hole under road, pavement, hard standing, by trenchless technology using ultra sounding technique including all necessary T&P and machine including HDPE pipe of 150 mm dia suitable for 0.40 Mpa working pressure complete all as specified and as directed.
Material and labour for 8 metre long octagonal hot dip galvanised (minimum thickness 75micron) pole with 70mm top and 130mm bottom dia and 2.5 mm to 3mm thickness with 220x220x12 mm base plate at bottom and 4Nos M20 grade bolt, 600mm long including bracket for street light made up of the 32 mm dia GI light grade pipe complete all as specified and as directed.
Supply and fixed LED Street light, 90 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on pole and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed. Note - Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of conduit shall be measured and paid as one unit length.
Material and labour for cement concrete in foundation, filling and mass concrete in 1:4:8 type D-2 using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supply and fixed cable jointing kit for 1100 V, Indoor/outdoor cable for straight through joint complete with jointing material, heat shrink type, and all accessories suitable for 3.5/ 4 core XLPE cable of 70 to 150 Sqmm complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fixed earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe conduit or fixing to pole for loop earthing GI strip of 32 X 6 mm complete all as specified and as directed.
MS AP CONSTRUTION AND CO
MPM ELECTRIC
JOTSHNA ELECTRICALS
Ultimate Solution Company
INDIA ELECTRICAL EQUIPMENTS
M/s Santosh Industrial Corporation
M/S Ali Trading Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .