Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹23.4 L
EMD Value
₹1.2 L
Closing Date
6 Dec 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSD PHE Mech Rural Division Sgr
Executive Engineer JSD PHE Mech Rural Division Sgr
Electro-mechanical works to be carried out at WSS Watsun Manigam
2023_PHE_238405_1
PHE/MRD/TS/ 121 of 11/2023
Open Tender
Miscellaneous Works
Item Rate
21 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Executive Engineer JSD PHE Mech Rural Division Sgr
₹1.2 L
Yes
19 Dec 2023
28 Nov 2023
6 Dec 2023
28 Nov 2023
6 Dec 2023
28 Nov 2023
Amount
Design, Manufacture, Supply, installation, Testing & commissioning of pole mounted, outdoor type 250KVA (11/4.4KV) 3 Phase neutral, Electric Sub Station (Level-2) as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. (REST TECHNICAL SPECIFICATIONS AS PER ANNEXURE)
Providing & fitting of ISMC150X75, 9ftlong, for resting of 250 KVA HV Power transformers with suitable dia. Size hole along with D-Clamps/Mukhi clamps nuts and bolts etc for fitting on poles as per site requirement. Note:- The Test certificates from the OEM of the cable should be provided/produced at the time supply
Supply, installation, errection of MS Tubular Poles-SP33, ISI mark HTL-IS 1161 or IS 2713 of 9mtrslongH.T pole having reduced 4”x5’’x6” from top to bottom and shall be anti-corrosive painted. The job includes providing/laying of cement concrete block in 1:2:4 mix/M15 (Cement concrete, sand aggregate block(s) (of size 3ft deepx1ft above the ground) for grouting of each pole ,Further includes drilling of holes for installation of various accessories .wherever required the job further includes G.I wire earthing of pole as per REC standard.
Supply, Installation, Testing and Commissioning of 3C x 35mm² XLPE HT Cable (ABC Type) of 11KV Grade. The job includes providing and fitting of Suspension clamps, Service Clamps, anchoring clamps and HT Clamps for execution of the job.
Supply, Installation, Testing and commissioning of 11KV G-O set polymer insulator type complete in every respect with all allied accessories 01 No. for tapping point and 01 No. for substation along with disc insulator sets complete 9( polymer Type -5KN).
Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV complete as per IS specs.
Supply, Installation, Testing and commissioning of Drop out Fuse set polymer insulator type for 11KV power supply.
Providing & fixing of 9KA lightning arrestor set station/post type complete with fittings
Providing & fixing of sign plates fabricated out of MS sheets of size1ftx1ft to be fixed on each pole. The job includes letter writing as 11KV Danger in red colour on the sign plates
Providing & fixing of anti climbing Devices
Belting angle set for holding transformer out of ISA 40X40X5mm
Providing & fitting of ISMC 75X40,9ft long, for with suitable dia. Size hole for installation of link set,D.O.set and lightning arrestor along with D-Clamps/Mukhi clamps, nuts and bolts etc for fitting on poles as per site requirement.
Providing & installation of guy consisting of complete Guy assembly turn buckle plate Guy insulators as per IS Standard and IEE rules.
Painting of poles Red oxide
Painting of poles Aluminum paint
Providing, installation, Testing & commissioning of 415 ±10%V (output), 3 phase Water cooled 125KVA/100KW Diesel Generator (REST TECHNICAL SPECIFICATIONS AS PER ANNEXURE)
S/I/T/C of three phase LT prodigy meter on the service line at the Sub-station (REST TECHNICAL SPECIFICATIONS AS PER ANNEXURE)
A. Electrification of Pump House P/F of lighting/fan points in 1.5 mm Sq. multi strand PVC wire as conducted to be laid /carried in PVC channel /conduit as per site requirement. The job includes providing and fitting of 5 Amp. Switch Button /angle holders to be fitted with 9 watt Syska/Phillipps/Orpat / Havells LED or equivalent lamps inside the Pump house.
A. P/F of heating points in 2.5 sq.mm (of any reputed make) multi stand conductor to be laid carried in PVC channel / conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine.
C. Supply, installation testing & commissioning of DP, MCB of required size enclosed in steel enclosure including cost of lugs, Cable Gland etc.
D. P/F of distribution board, 16-way SPN Single door, Regal Grey fitted with MCB 6 Amp- (6 No). for lighting in pump house, 10 Amp-(2 No). for flood lights and 16 Amp. 2 No. for Heating Points in Pump House. The job includes the cost 4 sq. mm multi stranded conductor to be laid as service line for lighting system from auxiliary Panel Board to Switch box inside Pump House.
E. Providing of 2Kw potable heat convector operating on single phase AC current provided with thermostat for effective temperature control.
M/S MODERN POWER SOLUTIONS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .