Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 CrAccepted-AOC RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹5.7 Cr Quoted ₹5.8 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹6.0 Cr+₹19.1 L (3.31%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹6.0 Cr+₹19.1 L (3.31%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹6.9 Cr+₹1.2 Cr (20.3%)Rejected-Finance 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | ₹6.9 Cr+₹1.2 Cr (20.3%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹7.5 Cr+₹1.8 Cr (30.5%)Rejected-Finance A 212B GALI NO 1 SHAKARPUR | DELHI | EAST DELHI | DELHI | 110092 | ₹7.5 Cr+₹1.8 Cr (30.5%) | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Third Wave Services Pvt Ltd L3 | VED PRAKASH ARORA L4 | M/S Chhavi Constructions Co L1 | A R construction L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | REPAIR TO DECAYED BRICK WALL INCLUDING EXTERNAL/INTERNAL FINISHES
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc | 16,413 | Sqm | 35 ₹5,74,455 | 20 ₹3,28,260 | 10 ₹1,64,130 | 9 ₹1,47,717 Lowest |
| 2.00 | M&L for newly plastered wall/ Ceiling surfaces etc and applying two coats of oil bound distemper of any colour including one coat of primer over one coat of 1 mm thick wall care putty by using using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS complete all as specified and as direcetd. (work to be carried upto 4 storey). | 5,765 | Sqm | 110 ₹6,34,150 | 70 ₹4,03,550 | 50 ₹2,88,250 Lowest | 79 ₹4,55,435 |
| 3.00 | M&L for complete removal treatment of old surfaces (plastered or unplastered) of wall/ Ceiling surface etc applying two coats of oil bound distemper of any colour including one coat of primer over one coat of 1 mm thick wall care putty by using using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS complete all as specified and as direcetd. (work to be carried upto 4 storey). | 2,974.64 | Sqm | 110 ₹3,27,210.13 | 70 ₹2,08,224.63 | 50 ₹1,48,731.88 Lowest | 79 ₹2,34,996.36 |
| 4.00 | Dismantling floor hearth or wall tiling including cement mortar bedding (incl backing), removing the rubbish off the premises of MOD land complete all as specified. | 4,280.7 | Sqm | 40 ₹1,71,228 | 25 ₹1,07,017.5 | 20 ₹85,614 | 19 ₹81,333.3 Lowest |
| 5.00 | M&L for 25mm thick plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub floors complete all as specified. | 419 | Sqm | 180 ₹75,420 | 180 ₹75,420 | 120 ₹50,280 Lowest | 199 ₹83,381 |
| 6.00 | M&L for double charged Vitrified tiles 8-10 mm thick (square/ rectangular) light shade polished,area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15 mm thick screed in cement mortar (1:6) complete all as specified and as directed. | 1,650.56 | Sqm | 1,340 ₹22,11,750.4 | 1,200 ₹19,80,672 Lowest | 1,200 ₹19,80,672 Lowest | 1,499 ₹24,74,189.44 |
| 7.00 | M&L for double charged vitrified tiles 8-10 mm thick (Square/ rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm as in skirting laid on 10mm thick cement plaster in CM (1:4) , set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles complete all as specified. | 136.71 | Sqm | 1,350 ₹1,84,558.5 | 1,250 ₹1,70,887.5 | 1,200 ₹1,64,052 Lowest | 1,699 ₹2,32,270.29 |
| 8.00 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:4 complete all as specified & directed. | 419 | Sqm | 890 ₹3,72,910 | 750 ₹3,14,250 Lowest | 800 ₹3,35,200 | 899 ₹3,76,681 |
| 9.00 | M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm of any colour, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:4 complete all as specified & directed. | 562 | Sqm | 940 ₹5,28,280 | 850 ₹4,77,700 | 800 ₹4,49,600 Lowest | 999 ₹5,61,438 |
| 10.00 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick( square/rectangular)area of each tile exceeding 0.18 sqm but n exc 0.36 sqm, as in skirting laid on 10 mm thick cement plaster in CM (1:4), set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles. | 70 | Sqm | 940 ₹65,800 | 900 ₹63,000 | 800 ₹56,000 Lowest | 1,099 ₹76,930 |
Tender Value
₹7.5 Cr
EMD Value
₹7.0 L
Closing Date
27 Nov 2025, 6:00 pmClosed
CE CG GOA
MILITARY ENGINEER SERVICE INDIAN COAST GUARD CHICOLNA JNC NAGAR ROAD BOGMALO POST GOA
ADDITION ALTERATION TO BLDG NO P3 COMMA P4 AND P6 OF COAST GUARD OFFICERS RESIDENTIAL QUARTERS AT KAMATH ENCLAVE SECTOR 52 NOIDA
2025_MES_737807_1
84024
Open Tender
Civil Works
Item Rate
690 days
NOIDA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹3,000
Yes
AGE (I) NOIDA
₹7.0 L
Yes
30 Mar 2026
30 Oct 2025
2 Dec 2025
31 Oct 2025
27 Nov 2025
20 Nov 2025
Amount
REPAIR TO DECAYED BRICK WALL INCLUDING EXTERNAL/INTERNAL FINISHES Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc
M&L for newly plastered wall/ Ceiling surfaces etc and applying two coats of oil bound distemper of any colour including one coat of primer over one coat of 1 mm thick wall care putty by using using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS complete all as specified and as direcetd. (work to be carried upto 4 storey).
M&L for complete removal treatment of old surfaces (plastered or unplastered) of wall/ Ceiling surface etc applying two coats of oil bound distemper of any colour including one coat of primer over one coat of 1 mm thick wall care putty by using using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS complete all as specified and as direcetd. (work to be carried upto 4 storey).
Dismantling floor hearth or wall tiling including cement mortar bedding (incl backing), removing the rubbish off the premises of MOD land complete all as specified.
M&L for 25mm thick plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub floors complete all as specified.
M&L for double charged Vitrified tiles 8-10 mm thick (square/ rectangular) light shade polished,area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15 mm thick screed in cement mortar (1:6) complete all as specified and as directed.
M&L for double charged vitrified tiles 8-10 mm thick (Square/ rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm as in skirting laid on 10mm thick cement plaster in CM (1:4) , set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles complete all as specified.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:4 complete all as specified & directed.
M & L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm of any colour, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes CM 1:4 complete all as specified & directed.
M&L Non skid coloured ceramic tiles 7 to 8 mm thick( square/rectangular)area of each tile exceeding 0.18 sqm but n exc 0.36 sqm, as in skirting laid on 10 mm thick cement plaster in CM (1:4), set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles.
M&L for 300x 600mm x 7 mm thick Glazed coloured ceramic digital wall tiles in pattern or concept set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering for backing of tiles in CM 1:4 complete all as specified & directed.
Dismantling Stone Slab including cement mortar bedding, removing the rubbish off the premises of MOD land complete all as specified.
M & L for Machine cut Kota stone single piece slab flooring stair landing, tread 20-25 mm thick over and incl 20mm thick screed in CM 1:6 complete cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and mirror finished polishing complete all as specified and directed.
M & L for Machine cut Kota stone single piece slab flooring stair riser of steps/ skirting / dado and pillar 20-25 mm thick over and incl 10mm thick rendering for baccking in CM 1:4 complete jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and mirror finished polishing complete all as specified and directed.
M&L for 18-20mm thick Granite (red rubby or as approved ) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and incl 20mm thick screed in CM 1:6 complete
Rounding to edges of stone slab one edge, such as steps, cooking platform and other similar situations and rubbing and polishing complete all as specified.
M & L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including polishing, grinding,moulding complete, pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified.
M & L for 20mm thick Screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified.
Demolition of brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built, built in cement motar 1:6. complete all as specified and directed.
M&L for brickwork except brick, using old brick by removing mortar and cleaning straight ot curved on plan exc 6m mean radius built in cement mortar 1:4 including dismantling of brickwork biult in cement complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition complete all as specified and directed.
S&F TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, beinding spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M & L for providing RCC (type B1 1:2:4) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like chajjas all as directed and specified.
Formwork to soffits of suspended slabs rough finished such as roof slabs, flor slabs, landings and similar work not exceeding 200 mm thick complete all as specified.
JOINERY WORKS: S & Fix in repairs 25mm dia stainless steel curtain rods grade SS 304, guage 20 with finial/side knobs, including fixing openable bracket BR 100MM long with tighting alanke nuts/side end brackets (in respective of complete accessories) all as direcetd,Pair of suitable bracket & shade of finials as approved by Engr-in-Charge.
Taking down chowkats or frames of doors with shutters (without taking of shutters from the frames) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down Chowkhats or frames of doors exc 1.5 sqm but n.exc 4 sqm with shutters (Without taking off shutters from the frame) complete all specifed and directed
S&F Pressed steel door frame of size 105 x 60mm for doors with one or more rebates incl necessary fixing lugs hinges, lock strike plate etc complee all as specified. The rates include for one shop coat of priming.
S&F Pressed steel door frame of size 125 x 60mm for doors with one or more rebates incl necessary fixing lugs hinges, lock strike plate etc complee all as specified. The rates include for one shop coat of priming.
S & F mild steel flat iron as in hold fast clamps articles conforming to FE 290 Gde 165 complete all as specified.
M&L for cement concrete 1:3:6 type C-1 (20 mm graded stone aggregate) as in back filing to pressed steel frames etc, complete all specified and directed
S&F 30 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/frame to match incl approved second class Hardwood lipping around complete all as specified and directed.
S&F 200mm long stainless tower bolts AISI 316 garde fixed to door with complete all as specified and directed.
S&F stainless steel mortice handles of AISI 316 Grade 150mm long specified and directed.
S&F in repairs for brass Mortice lock 4 levers, vertical type, size 100 mm complete fittings as per engr in charge
S&F stainless steel handle 200mm complete all as specified and directed.
S&F door stopper(double leg) of SS 304 with grip rubber fixed to door complete all as specified.
M&L for two coats of synthetic enamel paint on new wooden surfaces over a coat of pink primer to new surfaces including preparation of surfaces, over 10cm width or girth complete all as specified.
S&F 2nd class hard wood 35mm thick Glazed and skelton shutters , open rebated and prepared to receive glass, gauge etc(with sash bars) edges of framing plain, chamfered or rounded, fittted with cut and mitred beads for securing gauge,etc complete all as specified.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S&F stainless steel AISI 316 sliding door bolt of length 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed
Taking down window shutters with frame (not grill ) of any description n exc 1.0 sqm complete all as specified and directed
Taking down window shutters with frame (not grill ) of any description exc 1.0 sqm n exc 4 Sqm complete all as specified and directed
Supply and fixing factory made uPVC any colour fixed glazed ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge including 6mm thick toughened glass Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made, (Net opening shall be measured for payment purpose.) Make- Prominance, Finesta, Ecocell
Providing and fixing factory made uPVC sliding window of any colour approved by engr-in-charge, three track made of extruded profiles with wall thickness of 2.3m (±0.2mm). Window profile with hollow section with multi chamber frame (88mm x 52mm),sliding sash (42mm x 67mm), sliding mesh sash (42mm x 57mm), sliding interlock (one vertical length in each shutters) (45.5mm x 28mm) Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, incl railing of holes for fixing of hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ±0.2mm thick galvanised steel frame (30mm x 18mm) 02 nos, sliding sash (30mmx18mm), sliding mesh sash (26mm x 10mm), Profile to be insterted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : (touch lock of zinc alloyed (white powder coated), steel roller system, aluminium wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories including anti pigeon spiking arrangement) including 6mm thick glazing with 6mm thick toughened glass, aluminum track on bottom rail for three track sliding frame, wool pine for Sliding sash and interlock incl wire mesh as per manufacturer instructions and cost of glass and wire mesh includes all other connected accessories. Net opening will be measured for payment purpose.) Make- Prominance, Finesta, Ecocell
S & F solid PVC decorative door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. Make- Rajshri Plasticwood, Ecocell or equivalent
S&F Factory made solid panel PVC decorative door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either sides and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvent cement, and S&F in the frame at side as per specification and drawing. Make- Rajshri Plasticwood, Ecocell or equivalent
Providing and fixing factory made uPVC any colour fixed window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with 6mm thich toughened glass (Note: The unit rate quoted by contractor includes cost of glass and all other connected accessories Net opening will be measured for payment purpose.) Make- Prominance, Finesta, Ecocell
S&F powder coated anodised aluminium frame and shutter as in door , window, ventilator etc. with one or more rebates including joining cleat for fixing etc. fixed type/louvered/sliding window or ventilators without sash bar, aluminium including necessary joining cleat, glazing clips, rubber packing, anodised aluminium snap beading, stopper ,screw etc complete all as specified and directed by Eng-in-charge. Note: (a) Glazing shall be measured separately (b) Items shall be paid as per weight of of aluminium sections. (c) The rates quoted shall be inclusive of neoprene beading glazing clips, screws, etc as required which shall not be measured for arriving the weight. (d) The rate shall be inclusive of locking arrangement including complete all as specified and as directed
S&F in repair 4.8 mm thick sheet glass ordinary quality and glazing with Al glazing clips& EPDM beading in complete all as specified and as directed
S&F 150mm long aluminium anodised barrel tower bolt of extruded section and fixed to PVC door complete all as specified
S&F 150mm long aluminium anodised handles, extruded aluminium alloy CASE type and fixed to PVC door complete all as specified
S & F 100 mm SS AISI 304 butt hinges for door complete all as specified and directed.
Dismantling of mild steel shutter with frame of almirah/cupboard complete all as specified
S&F 19 mm thick marine ply as per IS 710 specification, finished with laminate on both sides (1 mm thick on front side of any colour and 0.8 mm thick on back side of white colour) and teak wood edging/lipping all around for shutter , frame and shelf of a almirah including SS handles 200 mm, locks with duplicate keys, SS piano hinge fitted and 15 mm SS rod of 1mm thick as a cloth hanger complete all as specified. Note :-All fittings/fixture deemed to be included in above quated rates
S&F 19 mm thick marine ply as per IS 710 specification finished with laminate on one side (1 mm thick of any colour) and TW edging/lipping all around for box of almirah complete all as specified . Note :- All fittings/fixture deemed to be included in above quated rates
Dismantling wrought iron or mild steel work of any description not otherwise provided for railing etc
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
S&F for rolled mild steel Fe-410- W(Gde- E-250) quality- B stairs (framed) including stringers, treads, landing, balusters, hand rails ,etc. including cleats, brackets, etc. complete all as specified
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
M&L for two coats of synthetic enamel paint on new steel surfaces over coat of red-oxide primer including preparation of surfaces, over 10cm width or girth complete all as specified and directed.
S&F in repair 1.25 mm thickness in laths Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple, spring etc and one shop coat of primer; erected in position as indicated, complete: push pull or manual type, complete all as specified as directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters
M&L for 5 mm thick designer galvanised mild steel Jalli exterior grade, design, shape and colour as approved by Engineer in charge incl necessary fitting fixed to wall or shaft complete all as specified and directed.
S&F brass magic eye for panelled/flush shutter 35mm thick complete all as specified and directed.
LEAKAGE /SEEPAGE OF KIT & TOILET AND BATHROOM ITEMS (SUPERIOR SPECIFICATION FITTINGS):- S&F in repairs Vitreous china wash down water closet pan wall mounted complete single unit including double syphonic flusing cistern white, seat cover including connection to drain trap complete. all as specified and directed. Make- Parryware CAT Part No: Verue white C0269 , C0762 cistern or equivalent in Jaquar/cera/Kohler
S&F wash hand basin Counter Top , white, flat back, any shape and size, including fitting to bottle trap complete all as specified and directed. Make: Jaquar Model No .FLS-WHT-5601 / hindware Cat Part No 91043/ equivalent of kohler
S&F in repairs CP brass wash basin Mixer single lever long neck fixed to counter top wash hand basin including complete accessories, unions, flenge, fixed to 15 mm bore complete all as specified and directed. Make: Jaquar Model No .OPP-CHR-15011BPM/ Kohler Model No July 75377IN-4-CP/ hindware Cat Part No F570012
S & F in repairs Brass CP Wall mixer with provn for overhead shower 115mm long bend pipe on upper side 3-in-1 for mixing hot & cold water screwed down for 15 mm bore including hand shower with complete fittings unions, wall flange, bends etc and fixed complete all as specified. Make: Jaquar FLR5281N, hindware F570022, Kohler 98755IN-4
S&F in repairs brass chromium plated shower rose of size 125 mm with 24'' Long arms including fixing to steel pipe complete all as specified
S&F in repair Corner sheet glass 225x225 mm assembly consisting of 5.5 mm thick toughened sheet with SS bracket guard and railing complete all as specified and directed by Engr in charge.
S&F in repairs Toilet paper holder with cover fixed to walls with chormium plated bracs screws complete. Make: hindware F880003, Prayag-BA38, Somany – 27213033091
S&F in repairs Health faucet cast copper alloy chromium plated with 1-1.5 mtr long flexible chrome hose pipe, including complete fittings, pressure not less than 6kg/cm2 and wall SS hooks complete Make: Jaquar Cat No – ALD-CHR-579/ or equivalent to hindware and Kohler.
S&F satinless steel Grade-304 soap dish with glass fixed to wall complete. Make: hindware Cat Part No – F5004106, Prayag-BA15, Somany – 27213033051
S&F in repairs angle valve with wall flange chormium plated fixed to 15 mm dia bore pipe including complete fittings. Make :- hindware F570043 or equivalent in Kohler and jaquar
S&F in repairs stainless steel foldable towel rack 60 cm long and 24 cm deep with towel rail and hanger at bottom fixed to wall complete all as specified as directed.
S&F 600mm long PVC connection pipe fixed to 15mm dia bore pipe ,complete all as specified and as directed.
S&F 110mm PVC (SWR) floor trap/ nahani, plain with SS grating with/without hole including jointing with solvent cement complete all as specified and directed.
S&F cast copper alloy chromium plated bottle trap with complete fittings all as specified and as directed.
S&F sheet glass shelf assemble consisting of 5.5mm thick glass shelf 12cm wide with stainless steel ( grade 304) bracket guard and stainless steel (Grade 304) railing 60cm long including fittings, complete all as specified and as directed.
S&F in repairs sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.
S & F in repairs brass CP sink mixer with drop down single lever with connecting legs screwed down for pipe 15 mm bore including complete fittings all as specified and directed. Make: Jaquar , Kohler -Atom 25981N-4-CP , hindware pull down flexible - F680027-1
S&F Vitreous China, pedestal pattern wash down water closet pan, white including fixing bolts, 10 litre capacity flushing cistern, seat cover and flush pipe connection to drain pipe (or out going pipe) and to flushing pipe, anti-syphonage pipe etc , complete all as specified and directed.
S&Fin repair Bib taps cast copper alloy, fancy type ISI marked screwed down to pipe of 15mm bore , complete all as specified and directed.
Taking up or down steel water tubing and connections of dia 20mm as specified.
Taking up or down steel water tubing and connections of dia 25mm as specified.
Supplying and laying of CPVC pipes 20 mm dia SDR 11 and including CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and laying of CPVC pipes 25 mm dia SDR 11 and including CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Cutting chases, pinning in, making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed waer tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth complete all as specified
Dismantling water tanks of capacity exc 250 litres but n.exc 500 litres complete all as specified and directed.
S&F 500 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers, with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II.
Dismantling water tanks of capacity exceeding 1000 litres but not exceeding 2000 litres complete all as specified and directed.
S&F 1000 ltr capacity HDPE water storage tank, cylinderical vertical with closed top, having three layers, with over all thickness as per IS with locking arrangements hoisted and fixed in position complete all as specified and directed in SSR Part-II.
S & F 25mm Nipple suitable for HDPE water tank (Minium weight 20mm - 45 gms) complete all as specified
S&F ball brass valves, high pressure, with polythene float and fly nut, screwed for iron pipe or brass ferrule 25 mm bore complete all as specified and directed.
S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 25 mm bore complete all as specified and directed.
S&F in repairs PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore , single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down existing pipes complete all as directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in floor or trenches including taking down existing pipes complete all as directed.
S&F PVC(SWR) bends any radius ,Tee 110 mm bore with / without access door complete all as specified and directed.
S&F PVC(SWR) bend of any radius, 160mm bore complete all as specified and directed.
S&F PVC(SWR) branch piece,bend of any radius , tee double (double Y) 75 mm bore with/without radius complete all as specified and directed.
S&F in repairs PVC (SWR) 'S/P' trap, 110mm bore complete all as specified and directed
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed
S & F Stack clamps made out of 50 mm by 5 mm flat iron and 16 mm dia around iron stays including bolt and nuts for securing ends of stays to walls or roofs, for any dia of pipe complete all as directed.
ROOF TREATMENT: Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
Demolition of mud phuska in roofs any thickness including plastering and leeping (whether full thickness removed or only a part thereof) complete including removal outside of MoD land complete all as specified and directed.
M&L for providing, cement concrete type B-0 (1:2:4) using 12.5mm graded stone aggregate as in roof kerbs, padding or mud stops, rounded or chamfered on edges all as specified and directed
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for roof treatment through manufacturer / authorized applicator of the manufacturer as approved by AGE (I) by applying a coat of cold applied bituminious oil based primer over cleaned surface @ 0.30 Kg/Sqm and appling a coat of hot blown bitumen VG-30 grade @ 1.0 Kg/Sqm after interval of minimun 8 hrs of priming and laying of APP modified five layer polymeric membrane 3 mm thick minimum weighing 3.60 Kg/ Sqm reinforced with polyster non-woven fabric (weight not less than 150 gms/Sqm) laid over primed roof surfaces by torch application and vertical surfaces up to grooves and width of overlap 75mm at the sides and 100mm in ends and tucked into the chase on verticle surface complete all as specified and as directed.
S&F for Heat Resistant Terrace ceramic Tiles (300 mm x 300 mm x minimum 10 mm thick) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and set and jointed with epoxy tile grout to match the colour of tiles using 3mm thick PVC spacers complete including providing skirting along the parapet walls of height as directed in the same manner including 15 mm thick backing coat in cement mortar 1:4, complete all as specified & directed
Preparation of surface cleaning, drying, making it sound & free from surface contaminants, removal of dust, laitance, grease, oil, curing compounds from release agents & other foreign particles, by wire brushing, grinding etc, incl removal of all old sealent and other treatments (if any) and Supply and apply of material for repairing the edges of the joints (in case of weak concrete at joint edge) and also configuring joint width ( in case of expension joints with irregular width more than the width of the specified combiflex tape width) with epoxy repair mortar as per manufacturers instructions, complete all as specified and directed. Note:- (a) Work shall be carried out as per manufacturer's instructions by authorised applicator of STP Ltd/ Sika/ Asian. (b) Work shall be executed upto 4 Storied building.
Supply material and apply 2mm thick and 300mm to 350mm wide flexible FPO based membrane SG system chemical based modified flexible polyolefin (FPO) with advanced adhesion, classification to EN 13501-1, service temperature -300C (min) to + 400C (max) in wet condition and -300C degree ( minimum) to plus 600C(maximum) in dry condition and the Tensile strength > 12N/mm2, Tear strength >40 N/mm, Elongation at break >600% ( as per EN 12311-2), as per manufacturers instructions, including M&L for applying epoxy based membrane adhesive on both sides of joints, before and after fixing of flexible FPO based membrane, complete all as specified and directed. Make- STP Ltd/ Sika/ Asian. Note :- (a) Work shall be carried out as per manufacturer's instructions by authorised applicator of STP Ltd/ Sika/ Asian. (b) The work shall be carried out upto four storied bldg height.
S&F for Stainless steel sheet 1 mm thick, grade 304, in required width or girth, bent to shape for protection of membrane, fixed in staggered counter holes with SS screws and rubber/ bitumen and steel double washers all as per directions of Engr-in Charge, complete all as specified and directed.
MODULAR KITCHEN: Dismantling boarding, any description fixed in any position fixed with screws complete
Providing and Fixing factory made 18 mm solid WPC (wood polymer composite) glossy laminated board of required size comprising of virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibers (wood powders/rice husk/wheat husk) and non toxic additives, made from extrusion process WPC foam sheet single extruded (inner) with having minimum density not less than 650 kg/cbm, having good screw holding capacity (Screw withdrawal strength of 2000N (face) & 1100 N (edge), minimum commissive of 50 N/mm2, Modules of elasticity 850 N/mm2 and resistance of spread of flame of Class A category with property of being Termite/Borer free . water/Moisture proof and fire retardant to be laminated with PVC foil of minimum 14 microns thick of approved design pasted on both sides of shutter and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws all as directed by Engr-in-charge. Material test certificate and authentication should be compulsory provided by the manufacturing company for Kitchen cabinets. Make:-Rajshree and Equivalent, Note: Contractor has to submit the design and drg of modular kitchen as per site conditions/requirements before execution of work for approval of Engr-in-Charge.
S&F in repairs 6 mm thick one side prelaminated decorative WPC sheet and other side plain in cupboard & like items inclusive of solvent cement & fixing at site complete all as specified and directed.e. Make- Rajshree or equivalent in any other approved makes.
S&F Modular auto concealed soft closed hinges 35mm 110 degree size complete all as specified and directed.
S&F stainless steel handle 200mm complete all as specified and directed.
S&F stainless steel handle 150mm complete all as specified and directed.
S&F PVC tape 18mm wide with adhesive complete all as specified and directed.
S&F multipurpose basket (470x535x150)mm stainless steel of grade 304 complete all as specified and directed.
S&F perforated cutlary (475x485x350)mm stainless steel of grade 304 complete all as specified and directed.
S&F grain trolly with base (450x500x300)mm stainless steel of grade 304 complete all as specified and directed.
S&F Three tier trolley bottle pull out of size 485x530x150mm of stainless steel of grade 304 complete all as specified and directed.
S&F bottle pull out 150x485x430 mm with two shelf stainless steel of grade 304 complete all as specified and directed.
S&F cup & soucer basket (470x535x100)mm stainless steel of grade 304 complete all as specified and directed.
S&F plate basket (470x535x200)mm stainless steel of grade 304 complete all as specified and directed.
S&F cylinder trolly stainless steel of grade 304 complete all as specified and directed.
S&F bin holder stainless steel of grade 304 complete all as specified and directed.
S&F detergent holder (254x152x279 mm) stainless steel of grade 304 complete all as specified and directed.
S&F for Telescopic drawer channel rollers for shelves of size 350mm long complete stainless steel of grade 304 complete all as specified and directed.
S&F for Telescopic drawer channel rollers for shelves of size 500mm long complete stainless steel of grade 304 complete all as specified and directed.
S&F in repair for wall mounted kitchen plate plate rack of size 900mmx600mmx250mm made out of 1mm thick stainless steel sheet of 304 AISI grade fixed to walls with required size of raw plug and steel screws as per manufacturer instructions, description and pattern shall be as per sample.
MISCELLANEOUS ITEMS: Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing the demolished material out of MOD land complete all as specified.
M&L for 20mm thick Screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified
M&L for 75mm thick plain cement concrete type C-2, 1:3:6 (20mm graded aggregate) in floors complete all as specified
M&L for digital Industrial parking tiles (colour and design as per direction of Engr-in-Charge) of size 300x300x10mm thick in floors laid over screed etc set and jointed with epoxy grout Ardex Endura as per manufacturer instruction complete all as specified.
Taking down of existing sunken slab treatment including demolition of sub base concrete of any description from the sunken portion and cleaning the surfaces by washing down with water and rubbish off the premises and treating the sunken portion as per following specifications:- (a) Cleaning and filling crevices, cracks and undulations by applying cement sand mortar mixed with SBR latex polymers of make- Dr fixit Pidicrete URP or equivalent of Sika or STP Ltd as per recommendations of manufacturer and then brushing the entire floor and walls of sunken area with neat cement slurry @ 3.00 kg/ sqm and laying 30mm average thickness of plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) over sunken slab portion in required slope and finishing the top surfaces even and smooth using extra cement . (b) Provision and fixing of 50mm dia PVC pipe as spout, projection 150mm beyond outer face of the wall of sunken floor to drain out water. (c) Apply two coats of acrylic cementitious water proofing coating resin base 2K, manufactured by M/s Pidilite industries Ltd, STP Ltd, Sika or equivalent make as approved by GE as per manufacturer recommendations on floor and all around wall surfaces duly sanding with dry coarse clean sand in second wet coat of 2K to make rough surface to receive plastering all as directed. (d) Laying a protective coat of 15 mm thick rendering in cement mortar 1:3 mixed with liquid water proofing compound @ 200ml per 50 kg cement or as per manufacturers instruction, of approved make on all surfaces of sunken area including vertical wall upto 450mm height, after preparations as mentioned above. Method of application for acrylic cementitious water proofing coating shall be followed as per manufacturers instructions. Note :- PCC sub base for filling under floor over treated sunken floor sufaces upto required level shall be measured and paid seperately under respective item of BOQ.
M& L for 100 mm thick Plain cement concrete, 1;5:10 type E-2 using 40 mm graddedaggregates laid in floor complete all as specified and as directed.
Demolition of reinforced cement concrete cover slab for MH/Spetic tank and removing the debris to a distance not exc 500 M as directed.
M&L for precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for cover slab for Man holes/Septic tank set in CM 1:4.
M&L 6 to 8 mm dia and over TMT bar cut to length, bend to shape required incl cranking bending & hooking ends & binding with MS wire annealed not less 0.9mm dia or securing with clips.
M&L for Factory made Precast heavy duty RCC drain cover 80mm thick with using 10mm dia reinforcement TMT bar including 1.00mm thick MS black sheet frame on edges with two coats of antecorresive paint over primer all complete, as specified and directed.
M&L for DWC sewage pipe line 150 mm dia, class SN8, laid and jointed including coupler to connect with PVC GT complete all as specified
M&L concrete bed to drain pipes for 150mm dia in cement concrete 1:3:6 type C2 including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed.
M&L, for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in CM (1:6) including demolition of brick work/stone masonry built in cement mortar complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC 1: 3 : 6, type C-2, using 20 mm graded crussed stone aggregates in surface channels and drains including necessary use & waste of formwork and demolition of existing old cement concrete of any description complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi tred/stopped ends etc complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (20 mm graded stone aggregate) as in plinth protection, 75mm thick, finished even and smooth without extra cement, including making joints 12mm wide to the full depth of PCC at every 3 mtrs and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
M&L for Forming jambs in CM 1:6 etc., to open ings (to foregoing item), including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work complete all as specified
M&L of factory made Fiberglass Reinforced Plastics (FRP) “CHAJJA” of “Fibreways” brand or equivalent 4mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos. vertically and 1 Nos. horizontally 50x2mm thick M.S. Flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete using silicon sealant from top and bottom to make it water proof in one single piece casted monolithically including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746 duly reinforced with fiberglass chopped strand mat (CSM) as per IS: 11551 complete with protective Gelcoat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight complete all as specified and directed Note : All fittings / fixtures including in above quote rates.
Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately), complete all as specified and as directed.
Removing demolished material exc. 1.50Km but n.exc 5 Km & depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Surface dressing n exc 15 cm deep complete all as specified
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for Machine pressed precast concrete interlocking paver block any colour, shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement & pigment, including sand filling under floor or in foundations inclding watering and consolidation complete all as specified and as directed.
Retrofication/Rehabilitation/Strengthening and Repair to RCC members :- M&L for Preventive treatment against the danger of carbonation in exposed faces of RCC members as given below :- (i) Taking down plaster from concrete surface,Cleaning existing surfaces of RCC members and making surface free of loose material, oil, grease etc. by vigorous wire brushing/grinding as directed by Engr-in-charge. (ii) Further, cleaning using biocide (as recommended by manufacturer) to ensure that surface is free of algae and fungus and no trace of paint (any type) left out. (iii) Cleaned surface to be allowed to dry. (iv) Spray a coat of primer (as recommended by manufacturer) over dry cleaned surface as required prior to final finish. Primer shall be diluted in proposition 2:1 with mineral turpentine. After application, primer shall be allowed to dry for 03 hours or as directed. (v) Apply a coat of neat Aliphatic Acrylic anti-carbonation (ACC) over the primed surface with air / spray gun at nominal rate of 3.5 ltrs per sqm as recommended by manufacturer. (vi) Apply a second coat of Aliphatic Acrylic anti-carbonation (ACC) after 5-6 hours as recommended by manufacturer complete and spraying sand manually on painted surface while the paint is wet all as specified and directed. (vii) Apply plaster of required thickness (minimum 10mm) in Cement Mortar 1:3 mixed with WPC @ 0.2 ltr per bag of cement as per manufacturer instructions. Make - Fosroc Dekguard S or equivalent of Sikka/ Mapei
M&L for following treatment on RCC surfaces :- (i) Removing plaster & finishes all around the columns, slabs & beams (on all four sides of column to full height , three sides of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete and under cutting/exposing the reinforcement all around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed). (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust using rust remover Rebaaklens RR of Fosroc or equivalent of sika/ or Mapei along the length of reinforcement . (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to old bars :- (i) Cleaning of all exposed old bars alround, and where directed weld new rebar of same dia (bar will be paid separately). (ii) Apply a single coat of Alkaline rust converting primer on alround old bars as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on old bars alround as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of rebars (those towards the concrete substrate) should not be left without coating. NOTE :- Measurement will be taken of surface area of reinforcement bars. Make - Fosroc NitoZinc Primer or equivalent of Sikka / Mapei
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25-30 mm thickness. Note : Application of PMM shall preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed within 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. Make - Fosroc Epoxy Bond Coat-Nitobond EP , PMM-Renderoc Sp40 or equivalent of Sikka or Mapei
M&L for treatement of cracks found in the core concrete :- (i) Opening of crack by making a ' V' notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge. (ii) cleaning ' V' notch/groove of all dust/debris/loose material
M&L for fixing injection nipples for grouting operation as per following steps :- (i) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ (300 mm c/c or thickness of structural member whichever is less) Note : In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (ii) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (iii) seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure that there is no leakage from any gap. (iv) Allow the polymer modified mortar to cure for 24 hours and ensure that firmly fixed in postion. (v) cleaning nipple one by one commencing from the top to bottom in case of column and one by one in alternate direction incase of beam/slab using blow compressed air followed by water injection and ensuring that there is no obstruction in free flow of grouting materials complete all as specified and directed. Make - Fosroc, Sikka, Mapei NOTE :- Each injection nipple shall be measured as one Unit.
M&Lfor Injecting " resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Grouting to be done in cracks till the nozzle refuses to accepts the grout. Note :(i) pressure shall be in the range of 2-3 kg/sq cm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardener shall be mixed in small quantities so as it is consumed within 30 minutes. Before use mixer shall be stirred thoroughly. (ii) Allow entire effected surface to cure for 24 hours. (iii) cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer. (iv) cleaning exposed surface of substrate off any dust /loose material after ageing of the grout as recommended by manufactuer. Make - Fosroc Injection Grout:Conbextra EP10 or equivalent of Sikka or Mapei
M&L for preparing surfaces for treatment of core concrete when found to be porous/honeycombed in following steps :- (i) Marking the area in marker as directed by the Engr-in-charge. (ii) Drilling holes of 16mm dia in an orthogonal grid on exposed cone of member @ 150 mm c/c both way, depth of the hole shall be about 60% of the element thickness. (iii) clean the drill hole using compressed air removing the dust/dirt. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole with the annular space around the nipple sealed with epoxy putty. It shall be ensured that the injected grount does not leak. (v) Allow the nipple to cure for 24 hours.Make - Fosroc , Sikka , Mapei NOTE :- Each injection Nipple shall be measured as One Unit.
S&F 12mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specifed by manufactuer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/Mapei). (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade as per following description :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF, FOSROC Renderoc RG45 or equivalent of Mapei using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
M&L for Drilling & chemical anchoring of new rebars/stirrups as per following description :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm. Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF , FOSROC Lokfix E77 or equivalent of Mapei) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete is part of this item. The cost of drilling hole & chemical anchoring with epoxy resin is included in this item.
M&L for Drilling & chemical anchoring of new rebars :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF , FOSROC Lokfix E77 or equivalent of Mapei) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete is included in this item. The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item. Note for Sl. item no 174 & 175 :-Reinforcement shall be measured and paid separately in respective item.
M&L for use & waste of form work using steel sheets, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. For the purpose of payment area in touch with concrete shall be measured.
S&F for strengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Providing and applying unidirectional high strength glass fibre sheet nitowrap GW or equivalent sikka 935 GSM/dry fabric thickness (=0.36mm ) has to be overlapped 4 times to achieve > 1.3 mm thickness. The FRP fabric shall be of unidirectonal fibres having fibre density of 2.56 g/cc and shall have tensile strength >2300 MPa tensil modulus > 76 GPa. ultimate elongation 3.1% the substrate shall be primed with natowrap primer and nitowrap encapsulation or equivalent Resin shall be used for saturation the fibres . The adhesion of the entire system (FRP) sheet, saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D4541 . The glass fibre fabric shall be wrapped to RCC members at the desired orientation using tamping rollers to avoid any air voids etc and sprinkling of sand shall be carried out over the final surface, all complete as per direction and satisfactionof the Engineer-in-Charge. Note for Item Nos 164 to 178 :- (a) The work of structural retrofitting as contained in BoQ item Nos 164 to 178 and as amplified in PS Clause No. 21 shall be executed before starting any other work and other works shall only be started after successful completion of structural retrofitting works. (b) The contractor shall submit MoU with experienced retrofitting specialist agency who is authorised applicator of construction chemical manufacturer being used in the work and same shall be approved by AGE (I) to carry out structural repair work . The agency should submit experience details of successfully completed similar works in the past. All the chemicals/mortars as mentioned in the items 164 to 178 above are as recommended by the manufacturers (Sika/Fosroc/BASF) instructions and shall be applied as per prescribed coverage area. The quoted rate against each item shall be inclusive of all the materials/chemicals etc and labour cost etc. The contractor shall bring the construction chemicals in sealed containers and submit all purchase vouchers which shall be entered in MB. Payment against work done shall only be released after receipt of purchase vouchers. (c) Supplying & errecting scaffolding upto required height with necessary H frames, pipes, couplers, buckles, bracings, top platform with support railing at top etc .at all levels of building including carriage of the materials to the location, erecting ,fixing the scaffolding and dismembering the same after working and taking away the scaffolding materials etc. complete is included in the rates quoted in BoQ.
(c) Providing and erecting temporary steel scaffolding around the building as required.The scaffolding is to be secured properly in position by bracings, ties, clamps,etc. complete including providing and erecting working platform at all heights as required, including removal after completion of work. (d) Providing and fixing dust proof netting with all required accessories/fixing arrangements as to cover existing installations and arrest the materials generated during repair works in adjoining areas and top revent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc. complete is included in below items rate.
SPECIAL ITEMS: M&L for external plaster 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive strength as per IS 4031 part-VI applied as per the manufacture's instructions including necesaery cement screed and prepartion of surface to received ready mix plaster complete all as specified and directed by Engineer-in-Charge,(work to be carried upto 4 storey).
M&L for two coats water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer's instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI.Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. (work to be carried upto 4 storey).
M&L for internal wall surface 10mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive strength as per IS 4031 part-VI applied as per the manufacture's instructions including necessary cement screed and prepartion of surface to received ready mix plaster and applying two coats of plastic paint of any colour over one coat of primer over one coat of 3mm thick Birla wall care putty, using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying plastic emulsion pain should be able to spray in hard to reach areas and penetration of plastic emulsion paint on the surface complete all as specified and directed by Engineer-in-charge
M&L for internal ceiling surface 5mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster and applying two coats of plastic paint of any colour over one coat of primer over one coat of 3mm thick Birla wall care putty, using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying plastic emulsion pain should be able to spray in hard to reach areas and penetration of plastic emulsion paint on the surface complete all as specified and directed by engineer-in-charge (work to be carried upto 4 storey).
M&L for internal wall/ceiling surface 10 mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive strength as per IS 4031 part-VI applied as per the manufactore instr including necesaery cement screed and prepartion of surface to received ready mix plaster complete all as specified and directed by Engineer-in-charge, (work to be carried upto 4 storey).
M&L for complete removal existing treatment and Preparing of old plasterd wall/ Ceiling surfaces and applying two coats of plastic paint of any colour including one coat of primer over one coat of 3mm thick Birla wall care putty by using using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 60 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying plastic emulsion pain should be able to spray in hard to reach areas and penetration of plastic emulsion paint on the surface complete all as specified and directed by Engineer-in-Charge complete all as approved by manufacturer and colour as approved by Engr-in-Charge.(work to be carried upto 4 storey).
S&F 8mm thick toughened glass of required size, making holes, including all fittings and fixed to SS railing/wall with SS brackets with necessary patchs in position over and including tinted film on one side with any design complete, all as specified and as directed.
INTERNAL ELECTRIFICATION : Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down old meter boxes including electric energy meter and connected assy and depositing to MES store yard complete. (Old meters shall be the Dept Property) complete all as specified and directed.
Taking down old Single pole and neutral enclosure with a two pin and earth plug and socket, DBs any type, any way, TPN any way including MCBs SP/SPN/ MCCB complete all as specified and directed.
Taking down old sub main wiring without conduit any size complete all as specified and directed.
Taking down ceiling fans 1200/1400 mm sweep from its position and depositing to MES store complete all as specified and directed.
Taking down of exhaust fan and deposited to MES store yard complete all as specified and directed.
Taking down Geyser 50 ltrs from Existing Position from wall including taking out bolts, washers and disconnecting incomming connections. Note : Geyser recieved from existing site will be deposited to MES store yard complete all as specified and directed.
Material and labour for point wiring with PVC insulated multistranded copper conductor cable FRLSH in and including PVC concealed conduit not less than 20 mm size, copper conductor cables 1.5 sqmm 2 run and one run of 1.5 sqmm cable as earth continuity wire, including Modular GI metal flush box, with minimum thickness not less than 1.2 mm, white cover plate with frame of suitable module etc complete for fitting switches, socket , bell push, ceiling rose, fan regulator etc including make good disturbed area same as existing with color and as directed by Engr-in-Charge (phase neutral and earth wire shall be provided in stranded color code R.Y.B. for phase ,black for neutral, green for earth wire) for One light point controlled by one switch SP, one way, 230 volts complete all as specified and directed.
All as per above item No.193 but for ceiling fan point complete all as specified and directed.
All as per above item No.193 but for exhaust fan point complete all as specified and directed.
All as per above item No. 193 but for bell point complete all as specified and directed.
All as per above item No.193 but for one 3 pin, 2 in 1, socket outlet 6 Amps on same board complete all as specified and directed.
All as per above item No. 193 but for one 3 pin ,2 in 1,socket outlet 5/6 Amps on independent board complete all as specified and directed.
All as per srl item No 193 above but for power socket 15/16 Amp with cable 2.5 sqmm for phase, neutral and earth but with 2.5 sqmm cable complete all as specified and directed.
All as above sl item No 193 but for one light point controlled by two way switch complete all as specified and directed.
Supply and fixing of Modular Switch 6 Amp one module complete all as specified and directed.
Supply and fixing of Modular switch 1 way 16A, 1 module all complete all as specified and directed.
Supply and fixing of Modular Bell push 6A 1 module complete all as specified and directed.
Supply and fixing of modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
Supply and fixing of modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and directed.
Supply and fixing of Modular Switch 6 Amp two way for staircase complete all as specified and directed.
Supply and fixing of modular Fan step regulator, 120W - 2 module complete all as specified and directed.
Supply and fixing of Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
Supplying & Fixing Decorative wall light, gold finish fixture with white glass diffuser including 5 W LED candle lamp E27 base complete all as specified and directed by Engr-in-Charge. Note: Quoted rate should be inclusive of 5 W LED candle lamp E27 base.
Supply and fixing of of Bell Multi Music type 230 volts single phase complete all as specified and directed.
Supply and fixing of LED tube light fitting. ,1x18/20 W, 230 V, LED Sparkle, complete with all accessories including driver, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing of light energy efficient luminarie with LED 10 Watt linear & compact 10 W light with decorative grey end caps, ploycarbonate body and ribbed opal diffuser all accessories pre-wired and including connection up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fixing of Mirror light energy efficient luminarie with LED 10 Watt linear & compact 10 W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser all accessories pre-wired and including connection up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fixing of environment friendly ultra modern energy saving surface mounted decorative oval plastic bulk head LED 10 W luminare comprising of high brightness LED's IP 54 protection CFL light fitting, 1x 10 w bulk head luminaries, complete with all accessories and including 10 Watt LED & connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50 HZ complete all as specified and directed.
Supply and fixing round shape 15 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete, all as specified and directed.
Supply and Fix Energy saving & environmental friendly long life Versatile pressure dia cast IP-65 cast aluminium roadway luminaire with high power LED as light source of capacity 35W LED 6000K complete with connecting wire of 1.5 sqmm FRLS PVC insulated unsheathed single core cable 1100 volts grade with multistranded copper conductor (upto 2.00 RM double run) testing and commissioning including GI pipe light grade 40 mm dia bracket with length upto 0.8 mtr complete all as directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fixing Exhaust/ ventilating fan PVC type 300mm size. 220 volt, 50 Hz single Phase with Lover for Exhaust/ ventilating fan 300 mm size including making square suitable size smooth hole complete all as specified and directed.
Supply and Fixing Exhaust/ ventilating fan PVC type 250mm size. 230 volt, 50 Hz single Phase with Louver for Exhaust/ ventilating fan 250 mm size including making square suitable size smooth hole complete all as specified and directed.
Supply and fixing of Electric Hot water storage tank ( Geyser) vertical type 25 ltrs capacity with star rating not less than 5 star rated with 04 Nos of sutable size of Stainless steel fastners with 02 Nos of flexible braided stainless steel connection pipe (1 set) of 450 mm length complete all as specified and directed.
Supply and fixing of sheet metal enclosures Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 to 32 amps, 240 V complete all as specified and directed.
Supply and fixing of Sub main wiring for PVC insulated single core stranded copper cable FRLSH of 2x2.5 sq. mm + 1x 2.5 sq. mm earth wire with proper colour coding and drawing in PVC conduit as per site requirements and make good distribured area same as existing with colour complete all as specified and directed.
Supply and fixing of Sub main wiring for PVC insulated single core stranded copper cable FRLSH of size 2 x 4 sq. mm +1x 4 sq. mm earth wire with proper colour coding and drawing in PVC conduit as per site requirements and make good distriburbed area same as existing with colour complete all as specified and directed.
Supply and fixing of Sub main wiring for PVC insulated single core stranded copper cable FRLSH of size 4 x 6.0 sq. mm and 1x6.0 sq. mm earth wire for earthing with proper colour coding and drawing in PVC conduit not less than 25 mm dia and make good distriburbed area same as existing with colour complete all as specified and directed.
Supply and fixing of Meter Boxes fectory made Hot press moulded SMC(Sheet Molding Compound) of size 400x300x190 mm suitable for 3 phase Electric Meter complete all as specified and directed. Make- Sintex Cat Part no. GSMB-4030 or equivalent in HPL
S & F Distribution board sheet metal enclosure double door, factory made, fixed flush with wall inside the niches for mounting MCBs 415 volts with bus bars with front openable cover Triple pole and neutral 4 way consumer unit complete all as specified and directed.
S & F Distribution board sheet metal enclosure double door, factory made, fixed flush with wall inside the niches for mounting MCBs 230 volts with bus bars with front openable cover Single pole and neutral 12 way 200 Amp bus bar consumer unit complete all as specified and directed.
S & F Distribution board sheet metal enclosure double door, factory made, fixed flush with wall inside the niches for mounting MCBs 230 volts with bus bars with front openable cover Single pole and neutral 4 way 200 Amp bus bar consumer unit complete all as specified and directed.
Supply and fixing of RCBO 4 pole 40 Amps 30 milli B curve, 415 Volt, 50 Hz complete all as specified and directed.
Supply and fixing of MCB SPN 5-32 Amps, 10 KA B curve, 230 Volt, 50 Hz complete all as specified and directed.
Supply and fixing of MCB SP 6-32Amps 10 KA, B curve, 230 Volt, 50 Hz complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm, burried vertically in ground ( earth pit not less than 2.25 m deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5m below ground level, connected to galvanised steel earth lead wire 4.00 mm dia ( 8 SWG), by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 15mm bore G.I. medium grade pipe from earth plate upto pole, upto 2.40 M height from GL by means of and including 25x3 mm MS Clamps, bolts, nuts and washers etc. and GI Earth lead wire then fixed bare along the pole and connected to MCB DB,LT Panel etc. with provision of charcoal dust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of soil/strata and testing complete all as specified and directed and shown on electrical plate No.3 of SSR Part I (2009) including earth pit chamber in mix 1:2:4 type B1 with MS angle iron frame CI cover complete. Note :- Cost of GI wire and protection pipe up to and including 7.5 m length is deemed to be included in unit rate quoted by the contractor.
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 4mm dia galvanised iron or steel wire
Supply and fix in replacement vertical distribution board, TPN 8 way suitable rated bus bar, factory made powder coated, double door suitable for 01 No MCCB, TPN 160 Amps 16 KA as incomer, flushed with wall or fixed outside on wall surface for mounting MCCBs / MCBs including connecting with new single core, multistranded copper conductor cable of suitable size all as directed. Note :(i) MCCB & MCB's shall be measured and paid separately.
Supply & fix MCCB, three pole, 415 volts, adjustable type, 160 Amps 16 kA including Complete all as specified and as directed.
Supply and fixing MCB TP 25 To 63 amp 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed.
M & L for fixing of outdoor wall-mounting MS bracket (powder-coated), suitable for 1.50–2.0 TR split AC outdoor unit, including drilling holes in brick/RCC wall, fixing anchor fasteners, nuts and bolts and leveling in such a manner so that any AC outdoor unit can be installed on same including cutting hole in wall up to 300 mm thick for AC piping, providing and fixing minimum 75mm dia PVC pipe sleeve and sealing the annular space with cement mortar/PU foam to make it weather-tight and pest-proof, complete all as specified and directed.
EXTERNAL WATER SUPPLY: Taking down Old US GI pipe of size 50 mm dia complete all as directed.
Taking down Old US GI pipe of size 25 mm dia complete all as directed.
Taking down Old US Gate valves of size 50 mm dia completed all as directed.
Supply, Laying, fixing and testing for 50 mm GI tubing medium grade with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc as per site requirement laid in trenches/floors/on wall with clamps complete making necessary connection and testing on completion of 50mm dia pipe complete all as specified and directed.
S&F Gun metal globe or gate valve of size 50 mm heavy duty with iron wheel head, screwed both ends for iron pipes complete all as specified and directed.
Supply, Laying, fixing and testing for 25 mm GI tubing medium grade with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc as per site requirement laid in trenches/floors/on wall complete making necessary connection and testing on completion of 25 mm dia pipe complete all as specified and directed.
Cutting to existing CI/DI/GI pipe line upto 150/100 mm dia for taking connection up to 50 mm dia GI pipe including insertion of CI /GI Tee of suitabel size including exc & earth work complete all as specified and directed.
Excavation in trenches not exc. 1.5 m in depth and not exc. 1.5 m wide for taking out or laying PVC / XLPE cable/ GI pipe of any size in hard/dense soil complete all as specified and directed. (Quantity for Ext Electric suppy = 62.1Cum and Ext water supply = 13.5Cum)
Returning, filling in trenches including spreading levelling, watering and well ramming in layers n.exc. 25 cm thick in soft/loose soil complete all as specified and directed. (Quantity for Ext Electric suppy = 25.30Cum and Ext water supply = 12.10 Cum)
Removing of surplus soil/excavated material to a distance not exc. 50 m away from the starting point and depositing where directed at al level not exc. 1.5 m above thestarting point complete all as specified and directed. (Quantity for Ext Electric suppy =36.80Cum and Ext water supply = 1.40Cum)
ELECTRIC CHIMNEY : Taking down old Exhaust fan of any size and any capacity and disconnecting cable end, dismantling blades and removing fan and blades deposited to MES store yard complete all as specified and directed.
Supply & Fix kitchen electric chimney of size 60 cm (filter less) single phase 230 volts, 50 Hz suction airflow of 1200 Cum/Hr, 150 watt motor, 1.5 watt LED lamp, 3 speed settings, metallic motor housing, GPSP painted touch control with motion sensor, complete including chimney installation kit (as recommended by manufacture) making suitable size hole for passing of exhaust pipe to outside and making good disturbed surfaces complete, 5 years of replacement warranty on motor and 1 year on product all as specified and directed
Supply & fix Air Circulator fans 230 volts single phase oscillating 300 mm sweep suitable for wall mounting with all fitting accessories all as specified and directed.
INSTANT GEYSER : Supply and fix water heater Instant type, electric, rated power 3KW capacity 6 litres,BEE 5 star rated with 02 Nos of suitable size of Stainless steel fastners with 02 Nos of flexible braided stainless steel connection pipe (1 set) of 450mm length complete all as specified and directed.
EXTERNAL ELECTRIFICATION: Taking down Old US LT Cable of size upto 50 Sqmm
Taking down Old US LT Panels complete all as directed
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size 120 sq mm 3½ core for as a service cable from existing sub station panel to proposed outdoor panel complete as specified and directed by Engr-in-charge complete.
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size 50 sq mm 3½ core for as a service cable from existing outdoor panel to proposed MCB DB complete as specified and directed by Engr-in-charge complete.
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size 35 sq mm 3½ core for as a service cable from existing outdoor panel to proposed MCB DB complete as specified and directed by Engr-in-charge complete.
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with multistranded aluminium conductor of size 10 sq mm 2 core for as a service cable from existing outdoor panel to proposed MCB DB complete as specified and directed by Engr-in-charge complete.
Material and labour for sand cushioning in layer not exc. 25 cm thick spreading out, levelling complete all as specified and directed.
Supply and laying of sub class B bricks locally available laying perpendicular to the axis of the cable for protection complete all as specified and directed.
Supply and fixing of Galvanised steel tubes, 50 mm bore, light grade passing through electric cable for crossing road, drain or vertical support to wall or protection for cable complete as specified and directed by Engr-in-charge complete.
M&L for cutting of road not less than 30 cm in depth and 30 cm in width underneath the road for passing the cable/pipe and making good with PCC 1:2:4 type B-1 where road cutting done to make the road surface fair and level complete all as specified and directed by Engr-in Charge.
Supply and Installation of RF Smart Three Phase Meter with the following specifications: • AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support sending the the following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from prepaid billing software • The meter should support open communication protocol DLMS with the software Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (Rate for the same will be paid under item No. 187 here-in-before). (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters would carry 5 year warranty.
Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network.
Supply and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. (iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal: The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.
(vi) Energy Accounting Module: The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module: The system would provide communication of energy data and bills via print, email and SMS methods. (viii) Meter Master Data: The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export: The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Make: Schneider, Innologix, SAP to be compatible with existing server (a) The software would be hosted either on GCC Server or on MES Server. In case the software is hosted on GCC Server, it would be transferred to MES server whenever the same is made available. (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) GE Bank account and one payment gateway would be provided by MES. The payment gateway would be integrated with the software.
Supply and Installation of single phase smart meter as repeater.
M&L for Provision of earthing with 600x600x6.0mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 25x4 mm by means of bolts,nuts and check nuts and washers of galvanised steel (and 40mm dia GI medium grade pipe for protection of G.I strip) to the extent of 7.5 metres as earthing lead and connecting to the eqpt, viz transformer, L.T. kiosk, H.T.lightening arrestors etc. including charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, M& L complete including excavation and earthwork in any type of soil strata and testing complete all as specified and directed. (Note : GI strip and earth protection pipe upto and including 7.5 m length shall deemed to be included in unit rate quoted by contractor)
S & F Earth continuity conductor or main earthing lead/strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc of size 25 x 4mm dia galvanised iron or steel wire
Two year comprehensive maintenance for RF Metering system including operating costs during two years of defect liability period. They would include the following items: (a) Monthly SIM charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the SIM or SIM provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution. (b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. (d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project would be developed. (g) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system. (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required.
Two years GCC Cloud Hosting charges during two years of defect liability period.
Eight year comprehensive maintenance for RF Metering system including operating costs after two years of defect liability period. They would include the following items: (a) Monthly sim charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution. (b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. (d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project would be developed (g) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required
Eight years GCC Cloud Hosting charges
A R construction (BID ID -3510758)
Third Wave Services Pvt Ltd (BID ID -3508950)
VED PRAKASH ARORA (BID ID -3510546)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Document
0.36 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tender Documents
Tender Documents • 0.99 MB
Tender Documents
Tender Documents • 0.68 MB
Tender Documents
Tender Documents • 0.32 MB
Tender Documents
Tender Documents • 1.78 MB
Tender Documents
Tender Documents • 0.38 MB
BOQ_826144.xls
BOQ • 0.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .