Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹16.5 L+₹2.0 L (13.7%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹18.2 L+₹3.7 L (25.7%)Rejected-Finance BX 167 4 ISHWAR NAGAR PATHANKOT PUNJAB 145001 UDYAM PB 16 0001334 03AALFR1593C1ZE B R | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹19.2 L+₹4.7 L (32.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹19.4 L+₹4.9 L (33.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
POST ATT PLINTH PROTECTION PLASTERING AND CERTAIN MISCELLANEOUS WORKS TO CERTAIN BLDG IN MH AND DHANGU COMPLEX UNDER GE S PATHANKOT
2022_MES_569896_1
GES/PKT/T-50/2022-23
Open Tender
Construction Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹40,000
Yes
21 Feb 2023
19 Dec 2022
19 Jan 2023
19 Dec 2022
17 Jan 2023
3 Jan 2023
Amount
Clean existing reinforcement with wire brush/ rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and providing applying two coats of rust remover and two coat of alkaline rust converting primer/ zinc primer and form a corrosion resitant, insoluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 1 hour between the coats use. (i) In Column/ Wall
In Beams
In Slab/ roof projection
Providing and applying, brush application, curing to form anticorrosive with high bond strength of anticorrosive polymer modified cementitious coating for corrosion inhibiting protection of reinforcement in one layers of total thickness of 2 mm.
In Column/Wall
In Beams
In Slab/ roof projection
Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness exceeding 40 mm but not exceeding 100mm by providing and casting with pre-packed dual shrinkage compensated micro concrete of minimum grade of M40 and above including providing and fixing of watertight foam faced finish shuttering all lead and lift mixing placing, deshuttering, levelling the surface by grinding off cementitious slurry of construction joints of differences in any to satisfaction of Engr-in-charge, curing etc, complete all as specified.
In Column/ Wall
In Beams
Rebuilding the section of damaged RCC elements to its original size or as directed by Engineer-in-Charge in thickness not exceeding 60 mm in layers of min thickness exceeding 20 mm and avg thickness 40 mm each by providing and applying ready mised duel shrinkage compensated thixotropic mortar (PMM) of minimum grade M40 and above, including all lead lift, mixing by addition of water only as per manufacture's recommendation, levelling the surface, curing etc complete all as specified.
In Slab/ roof projection
M&L Providing precast cement concrete 1:2:4 type B-0 using 12.5mm graded aggregates louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4.complete all as specifed and directed.
M&L Providing precast cement concrete Type B-1 1:2:4 in window or door ,cills,lintels,bressumers ,steps, quoin block(for use with masonry) string courses, copings, kneelers, apex stones, pier caps, columns,posts,boundry pillars,bed plates,pikntle block, anchorage blocks, bonders(for stone walling), corbels,brackets etc(of any section indicated) with plain fair faces,including chamfers weathering throating etc and setting in mortar complete with joints to match complete all as specified.
M&L Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
M&L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron all as specified and directed.
Demoliton of cement conc of any description in any position not specifically provided for, all as specified.
M&L 50mm thick PCC, type B-1, 1:2:4, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement complete all as specified and directed.
S & F glass deviding strip 3mm thick and 38 mm wide fixed to design complete all as specified and directed by Engr-in-Charge.
M&L fo 75mm Cement concrete type D2 1:4:8 as in sub base of flooring complete all as specifed as drected by engr in charge.
M&L for 100mm thick plain cement concrete 1:2:4 type B-1 (using 20mm crushed stone agg ) as in floors ,ramps,hard standing or as in similar work finished even and smooth without using extra cement including form work where required all as specifed and directed .
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per sqm. complete.
M&L for 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete roof surfaces , finished even and fair to receive treatment on roof complete all as specified and directed.
Supply only water proofing compound.
Providing and laying of water proofing treatment of roof APP (Atactic Polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane, super thermply non woven polyester mat reinforcement of 160 gsm, weight of membrane @ 3.6 Kg/Sqm over a solvent based bitumen primer @ 0.3 Ltr Sqm by the same manufacturer conforming to IS:3384-1986 , The membrane shall be laid using bitmun torch.The end lap should be 100 mm and the side lap must be minimum 75 mm the membrane shall be first laid up to the parapet wall junction and then shall be overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/ up to 500 mm, membrane shall be terminated at the top of parapet.All rain water pipe opening shall be suitably sealed with the APP membrane all as specified and directed. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster)
M&L PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in padding over roof slab for providing proper slope 1:40 and approx thickness 50mm or less and finished the surfaces even and smooth wihtout unsing extra cement complete all as specified and directed.
Taking down old damaged SGSW/UPVC/RCC pipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 150 mm dia RCC NP3 pipe laid and jointed complete including providing 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed .
Taking down old damaged SGSW/UPVC/RCC pipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 200 mm dia RCC NP3 pipe laid and jointed complete including providing 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed .
M&L for PCC (1:3:6) type C-2 using 20mm graded crushed stone aggregate as surface channels and drain etc including necessary form work complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed
Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specifed and directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed.
All as per description of item 27 above but except bricks complete all as specified and directed
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for 15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including scaffolding at any height and including two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat complete all as specified and directed.
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including scaffolding at any height including preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. all as specified.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement mixed with and including necessary formwork at any height with two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces any description including raking out joints hacking for key scrubbing down with water,M&L rendering 10mm thick on concrete in CM 1:3 in facia or edging of chajjas,ceiling and roof projection making the line in true shape finished even & smooth without using extra cement including formwork upto 7 M height and applying three coats of white wash complete all as specified and directed.
Taking down cement plaster on concrete surface of chajja or facia , any description at any height ,M&L rendering 10mm thick on concrete in CM 1:4 in facia or edging of chajjas, (width/height not exceeding 45 cm ) to protect movement of water inside and act in place of damaged drip course including prepration of new surface and applying two coats of cement base paint, complete all as specified and directed.
Refixing Aluminum frame with suitable rawl plugs with brick/concrete wall all as per direction of Engineer-in -charge including finishing Jams surface with existing wall surface all as specifed.
Refixing Aluminum shutter of any dscription exc 1.00 Sqm n exc 2.50 sqm each after Easing and adjusting by opening all side members and refix with cleats and screw in true alignment including existing fitting/ fixtures as in the same opening complete with Aluminum frame, complete all as specified and directed.
Taking down of old PVC wall lining, preparation of surface, S&F solid PVC Wall lining consisting of 5mm thick printed colour PVC sheet inclusive of solvent cement and fixing at site on pvc frame as per specifications and drawings, complete all as specified and directed.
Taking down of old PVC sheet fillets, S&F 5 mm thick PVC sheet fillets of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
jagdambe traders
M/S RUDHRAKSH TRADING CO
Jay Ann Construction Company
Amarjit Brothers
Balaji Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .