Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.3 CrAccepted-AOC | ₹3.3 Cr | 1 | Accepted-AOC Being lowest tender |
| 2 | 2₹3.4 Cr+₹2.9 L (0.88%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹3.4 Cr+₹2.9 L (0.88%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹3.5 Cr+₹15.5 L (4.63%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹3.5 Cr+₹15.5 L (4.63%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹3.5 Cr+₹18.7 L (5.59%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹3.5 Cr+₹18.7 L (5.59%) | 4 | Rejected-Finance Not being lowest |
| 5 | 5₹3.7 Cr+₹36.7 L (11.0%)Rejected-Finance | ₹3.7 Cr+₹36.7 L (11.0%) | 5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹6.0 L
Closing Date
12 Jan 2021, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CE DELHI ZONE DELHI CANTT-10
PROVN OF HT 11 KV EXTERNAL ELECTRIFICATION ITEMS/WORKS FOR CEILING FANS, GEYSERS, EXHAUST FAN ETC AT DELHI STATION UNDER GE (U) ELECTRIC SUPPLY DELHI CANTT-10
2020_MES_394565_1
CEDZ-30 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Works
270 days
DELHI CANTT
MES contractor enlisted in MES under class A cat b ii having deposited Standing Security of Rs 7.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
9 documents required · 9 mandatory
₹3,000
GE (U) ELECTRIC SUPPLY DELHI CANTT
₹6.0 L
Yes
8 Feb 2021
11 Nov 2020
14 Jan 2021
11 Nov 2020
12 Jan 2021
5 Jan 2021
Amount
Supply, installing, testing and commissioning of outdoor type plinth mounted step down transformer, 11 KV/433 Volts (at no load), Level -II, AC 3 phase 50 Hz, 1000 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. The transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014 and shall comprise of the following :- (a) One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 core 120 Sq mm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Airrelease valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50 x 6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing electrodes (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Unidirectional roller wheel. (n) Other accessories as per manufacturer design. (o) Oil temperature indicator, winding temperature indicator, marshling box single window, double flit buchhloz relay with alarm and trip contact. NOTE : Transformer shall be supplied inclusive of initial oil filling to appropriate level of insulation oil with desired dielectric strength. Cost of Provn of plinth for transformer as per OEM drawing shall be deemed to be included in the cost inserted by the bidders
All as per Item No 1 here-in-before but capacity 630 KVA
All as per Item No 1 here-in-before but capacity 500 KVA
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts, gradecross sectional area 120 sq. mm, 3 core as per IS-7098, Part-II complete all as specified and directed
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and directed
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed
Supplying, installing, testing and commissioning in replacement of gang operated air-break switch, triple pole off load, with drop out fuse set insulator , mounted on channels outdoor, vertical mounting type HT 11KV, 50 Hz of rating 200 Amps, ISI marked, mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with adequate lenth of GI pipe 32 mm dia medium grade , and locking arrangements including , complete with fuse mounts, fuse carriers and HT fuse elements having suitable rating in respect to load , necessary electric connections, complete all as specified and directed
Supplying, installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 20kA/3-sec, outdoor (IP55), RMU (Ring Main Unit) 4-way comprising of 02 Nos manually operated Load Break Switches and 02 Nos 630 Amp Fixed-Type spring-charging VCBs, electrolytic grade copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with minimum thickness 3+0.5 mm, IP 67 Degree of Protection, internal-arc classified 20kA/1sec as per IEC62271-200, on-site-repairable with site replaceable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have pad lockable double-door access with anti-theft hinges, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site. (A) 02 Nos Incoming Load Break Switches module each consisting of following accessories :- (i) Each switching-unit shall be designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 20kA/3-sec, Making Capacity 50kA - 01 No (iii) Auxiliary contacts 1NO + 1NC - 01 No (iv) Spring-assisted snap-action manual mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE cable termination in live-condition : Each Set of 03 (vi) Right angle boots (push on type) : Each Set of 03
(vii) Arc proof cable covers having cable entry from bottom, front with Interlocking mechanism including earth switch - 01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It shall be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault - 01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No Make :- ABB/Schneider/Siemens (B) 02 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 20kA/3-sec, Making Capacity - 50kAp - 01 No (iii) Aux. contacts 1NO+1NC - 01 No (iv) Stored-energy manual high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow un-inhibited operation -01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV, 185 Sqmm, 3 Core, XLPE cable termination in live-condition - Set of 3 (vi) Right angle boots (push on type) - Set of 3
(vii) Associated ring-core cast-resin insulated CTs 50/1 Amp 2.5 VA, 5P10 for protection – Each Set of 3 (vii) O/C + 1E/F self powered numerical protection relay with Low and High set for over current and Earth Fault. Relay shall have the facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping and shall be communicable on MODBUS. (viii) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (ix) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (x) Mechanically latched buttons for breaker On/Off - 01Set (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel. (C) Additional equipment delivered separately or mounted separately :- (i) Operating Handle for Manual Isolator/Disconnector/Earthing Operation - 02 Nos (ii) Standard Manometer - 01 No (iii) Operation and Maintenance Manual - 01 No (iv) Installation & Commissioning Manual - 01 No (v) Cable clamping provision (standard) - 01No Note :- (i) It shall be preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessary interlocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of Provision of Plinth for RMU as per OEM drawing shall be deemed to be included in the cost inserted by the bidders.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade as per IS-7098, Part-I,The cable shall be laid under road, footpath, pipe/duct, wall & PCC complete all as specified and directed of following sizes :-
All as per item No 12 above but of size 630 sq mm single core
All as per item No 12above but of size 400 sq mm single core
All as per item No12 above but of size 500 sq mm 3.5 core
All as per item No 12 above but of size 400 sq mm 3.5 core
All as per item No 12 above but of size 240 sq mm 3.5 core
All as per item No 12 above but of size 185 sq mm 3.5 core
All as per item No 12 above but of size 150 sq mm 3.5 core
All as per item No 12 above but of size 50 sq mm 3.5 core
All as per item No 12 above but of size 35 sq mm 3.5 core
All as per item No 12 above but of size 25 sq mm 3.5 core
Supply and fixing MCCB 4 pole 630 Amps rupturing capacity 36 KA 415 volt with Microprocessor release on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 400 Amps rupturing capacity 36 KA 415 volt with Microprocessor release on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 250 Amps rupturing capacity 36 KA 415 volt Adjustable type on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 160 Amps rupturing capacity 25 KA 415 volt Adjustable type on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 25 KA 415 volt Adjustable type on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Earthing with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in soft/loose Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Dosconnecting HT /LT connection, earthing connection from Transformer of capacity 400 to 630 KVA and M & L for shifting of the Transformer from one pocket to another pocket as directed and reinstall to new place by connecting HT/LT connection , Earthing connection carefully without any damage complete all as specified and directed
Disconnecting HT/LT connection, earthing connection from Transformer of cap 250-315 KVA and M & L for shifting of Transformer of capacity 250-315 KVA from site to MES yard complete all as specified and directed
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/losse soil) for laying of cables or GI pipe and getting out and levelling of bottom suface to required level complete all as specified and directed
M&L river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as specified and directed .
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.complete all as specified and directed
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed
Boring of hole under road/pavement/hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm bore and making good both ends complete all as specified and directed
Boring of hole under road/pavement/hard standing or any other situation by mannual means and including for GI pipe up to 100 mm bore and making good both ends complete all as specified and directed
Supply and lay GI pipe 100 mm dia light grade as cable protection laid on trench/floor, fixed on pole/wall etc complete all as specified and directed
All as per item No 49 here-in-before but of size 80 mm dia
All as per item No 49 here-in-before but of size 50 mm dia
M/L for Demolition of road/path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
Excavation in post holes (for similar holes) each n exc 0.5 cum soft/loose soil and getting out, returning, in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed
M&L PCC 1:3:6 (typeC2) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed
Supply only chain link MS galvanised fencing any size or type including provision of binding wire complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed .
S&F framed bracket of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting etc as in fencing post including cutting tops to shape as directed, drilling holes, notching for wire etc complete as specified and directed
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L coarse aggregate filling using stone gravels, rounded, of size n exc. 43 mm suitable to site, in the area covered by four pole structures complete all as specified and directed.
M&L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) 150mm thick complete all as specified and as directed.
M&L for Earth continuty conductor or main earthing lead fixed to wall on batten or racess or chases or burried in ground or drawn in conduit/pipe or fixed to pole, loop earthing etc as required size 32 x 6mm galvanised iron strip complete all as specified and directed
M&L for preparation of new steel surfaces of any description, n. exc. 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Taking out the old unserviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/ wall /floor /road /culverts or pole of size 300-400 sq mm 3.5 core complete all as specified and directed
All as per item No 63 here-in-before but of size 185-240 sq mm 3.5 core.
All as per item No 63 here-in-before but of size 120-150 sq mm 3.5 core.
All as per item No 63 here-in-before but of size 25-35 sq mm 3.5 core.
All as per item No 63 here-in-before but of size 16-25 sq mm 2/3.5/4 core.
Taking out underground HT/LT cables by excavation and removing PCC cover of any size and relaying or re-routing to another direction complete all as specified and directed. Note:- (a) Retrieved old serviceable PCC covers/ bricks will be laid in trenches for cable protection. If extra PCC cover/ bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (b) Excavation and earth work will be measured and paid for separately under respective items of schedule.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled Red, with letters, figures, and coventional skull and bones, in signal white colour and fixed with MS CLAMPS, bolts, and nuts of approved size, for HT 25 X 20CM size complete all as specified and directed
M&L for cable route indicator comprising of cast iron disc 100 mm & 3 mm thick with inscription "MES HT/LT XLPE CABLE" & fixed with angle iron 25x25x3mm & 30cm long with GI bolt & nut embedded in the ground in route of the cable in PCC 1:3:6 complete all as specified and directed
Disconnecting LT supply, earthing connection from LT Panel of any cap and any size and M& L for taking down the old unsv LT Panel from it's own position complete all as specified and directed
Disconnecting LT supply, earthing connection from LT Panel of any cap and any size and M & L for shifting of the LT Panel / feeder piller from one pocket to another pocket as directed and reinstall to new place by connecting LT connection, Earthing connection carefully without any damage complete all as specified and directed
Leo Air and Power Solution pvt Ltd.
M K ENGINEERS CO.
Sant Construction Co.
Chauhan Associates
AMIT ASSOCIATES
M P TYAGI ENGINEERS AND CONTRACTORS
B D Raizada Projects Pvt Ltd
K B Contracts Pvt Ltd
Bidder Name
AMIT ASSOCIATES
Chauhan Associates
K B Contracts Pvt Ltd
B D Raizada Projects Pvt Ltd
Sant Construction Co.
M/s JAIMAA ASSOCIATES
M P TYAGI ENGINEERS AND CONTRACTORS
M K ENGINEERS CO.
Leo Air and Power Solution pvt Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .