Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹32.9 L+₹8.4 L (34.0%)Rejected-AOC PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L2 | Rejected-AOC Not Being Lowest | |
| 3 | L3₹35.4 L+₹10.9 L (44.2%)Rejected-AOC | L3 | Rejected-AOC Not Being Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Oct 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR TO ROOF, JOINERY, TILING, PLUMBING AND CERTAIN CONNECTING WORK ALONGWITH REPAIR/ REPLACEMENT OF OLD WIRING WITH COPPER WIRING AND MISC WORK AT PRATAP CHOWK, TAURUS ENCLAVE, ASSU UNIT, ARMY HQ PROVOST UNIT, CIU MESS, DAPS-I, ARJAN VIHAR, NEW PR
2024_MES_675288_1
GE/C-66/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹90,000
Yes
26 Dec 2024
19 Sept 2024
21 Oct 2024
19 Sept 2024
18 Oct 2024
3 Oct 2024
19 Sept 2024 - 3 Oct 2024
Amount
Demolition of cement concrete in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as directed.
M& L for rubber moulded Chequered cement concrete colour tiles 30 cm x 30 cm x 25mm thick with mixture of grey cement & pigment set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in C M 1:6 complete all as specified and as directed.
M & L Machine pressed precast concrete rubber moulded interlocking dark coloured paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 Grade all as specified and disposing to debries etc all as directed by Engr-in-Charge.
M&L sand filling under floors or in foundation including watering and consolidation.
M&L Cement concrete ( 1:2:4) type B-1, using (20mm graded stone aggregate) 25 mm thick as in sub base complete all as directed.
M &L for Brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed .
M&L for rendering 15mm thick on top of roof concrete incl taking in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing incl taking down complete all as specified.
M & L for applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on top of roof surface in multiple coats @2 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and other coats needs to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. When the 2nd coat is wet, the Smartcare EPDM tape (at corners and edges)shall be inserted between second and third coat to secure corners & edges, let the material ooze out from the tapes corner. Same treatment of Smartcare Dampproof shall be continued to the parapet walls to better envelope the whole area. The coating shall be terminated carefully to the other side of the parapet wall.
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints upto G+5 storey bldg complete all as specified.
M&L for applying two coat of silver Shield BITUMINIOUS paint on APP membrane complete all as specified and directed by Engr-in-Charge. Notes for item No 8, 9 and 10 (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted by L1 contractor within 7 days after opening of Financial Bid otherwise tender will be cancelled. (d) A guarantee amount of 5% of contract of work done for item No 8, 9 and 10 of BOQ will be retained for 5 years of the completion of work.
Disconnecting existing water tanks, setting aside (or lowering if required) for cleaning,repairing and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes and reconnecting and refixing in position for tanks capacity exc 500 and n.exc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia GI tubing and connections complete all as specified.
Taking up or down 20 mm dia GI tubing and connections complete all as specified.
S&F 15mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors, pipes should be painted with bituminous paint of approved quality complete all as specified and directed.
S&F 20mm dia GI tubing medium grade with all fittings and fixed to wall and ceiling or laid in floors etc complete, all as specified.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed incl Dismantling of PVC water tanks of exc 500 litres and n.exc 1000 litres capacity of any condition or type incl complete all as specified and directed.
Cutting shrubs wild growth, plants not exc 30 cm girth grown on permanet structures and removing same growth right from roots and stopping the recurrence by injecting herbicide Glyphosphate 4+ solution (04 % concentrate) into plant root to eliminate further growth. Application shall be as per manufactureres intructions. The disturbed area shall be repaired with PCC (1:2:4) Type B0 mix and surface finished even and smooth in cm 1:4 incl applying two coats of matching finish i.e. Building is not less than 50 nos . complete all as specified and directed at site.
Excavating in posts holes (or similar holes) in soft/loose soil each n.exc 0.50 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm complete all as specified and directed.
S&F in repairs pre painted galvalume aluminum ZINC coating GI base corrugated steel 0.5mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding to wall fixed with self tapping screw with minimum 150mm end lap and one corrugation side lap including dismantling the existing sheets complete all as specified and directed.
M&L for steel work in tubular trusses inclung special shaped washersetc omplete using ERW or induction butt welded tubes complete all as directed by Engr-in-charge.
Preparation newly or previously untreated steel surfaces of any description over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide complete all as directed.
M & L Cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) in foundations, filling and mass concrete as in sub base incl demolition all as specified.
M&L for cement concrete 1:2:4 type B1(using 20mm graded stone aggregate) as in blocks for hold fast, coping, benching etc. including weathering, slightly rounded or chamfered angles or throating including form work to concrete surfaces incl demolition complete all as specified.
S&F in repairs 10 ltrs PVC (White) valve less syphonic action type, flushing cistern low level with inlet ball valve float, handle, Aluminium brackets for bottom support fixing with gitties embeded in wall with drilling machine etc complete all as specified.
M & L for 600x600x08 to 09mm thick coloured vitrified tiles(joint less) (make of tiles as approved by GE)as in floor over and including 15mm thick screed bed in CM 1:6, including pointing in coloured cement to match the shade of tiles including hacking out the existing floor surface,cleaning with water and applying cement slurry @ 3 kg/sqm on prepared surface of floor and including cutting/adjusting of existing door shutter at required height after taking down and refixing complete all as specified directed.
All as per item No 25 above but to 10mm thick on rendering surface in CM 1:4 on vertical surfaces of wall as in skirting including taking down of existing skirting/dado with screed/plaster on walls complete all as specified directed by Engr-in-Charge, and approved by GE all as directed.
M& L for non skid coloured rectified ceramic tiles (300x300x)7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed for laying floor in CM 1:6 including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engineer in Charge, approved by GE.
M&L for coloured ceramic tiles (300x600mm)x7mm thick on vertical surfaces on skirting /dados and risers to steps etc including rendering 10mm thick cement mortar in CM 1:4 ,including dismantling the existing tiles with screed and removal of debries out of MOD Land complete all as specified and directed by Engr-in-Charge, approved by GE.
S&F in repair stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe including connecting union overall size 1145mm x 510mm x 200mm with bowl size 510mm x 400mm x 200 mm including taking out existing Complete including fixing of granite slab with and including providing suitable size groove for adjusting top level ,moulding of slab each side and polished all as specified.
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
S&F false ceiling system including tiles, grid, angles, cleats etc and then refixing the false ceiling using plain galvanized steel ceiling system consisting 600x600mm lay in tiles of pre coated galvanized steel sheets in 0.5 mm thick in white or coloured to be laid of grid system with 15mm wide T section flanged having rotary stitching on the main runner and 1200 mm cross tees. the main runner and 1200mm cross tees. The main runner spaced 1200mm centre flush fitting 1200mm long cross tees to be interlocked between runner at 1600mm centre to form 1200x600mm module. Permeter trim to be wall angle of size 3000x19x19mm secured to wall @ 450mm centre to centre and incldg. suspension system as per manufacturer instructions complete all as specified and directed by Engr-in-Charge and directed.
Taking down chowkhats or frames n exc exc 1.5 Sqm (without taking off shutters from the frame).
Taking down chowkhats or frames exc 1.5 Sqm but not exc 4 Sqm(without taking off shutters from the frame).
S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including aluminium alloy Powder coated standard 10mm section window grill as per approved sample and as per IS specifications joining cleat for fixing etc. complete all as specified.
S&F Powder aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized iron staples including wooden beadings, complete all as specified and directed.
S&F 4.00 mm thick plain glass, pin head type and glazing with wooden beads, glass putty, PVC beading, aluminium beads, complete all as specified.
S& F 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (b); supplied and fitted to chowkats (incl two nos 100 mm long extruded aluminium tower bolts, two nos 75mm long medium weight MS butt hinges, 01 nos 125 mm long extruded aluminium handles and two coats synthetic enamel paint along with one coat of pink primer) all as specified and directed.
S&F in repairs Glass shelf assembly 450mm long 150mm wide with cp railing complete all as specified and as directed.
S & F in repair Glass Corner Shelf 10mm thick including CP railing radius 300mm radius complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs heavy door cill of length n exc 1 Rm having sufficient ability to provide dust free floor surface incl all necessary fittings and fixtures complete all as specified and directed.
S&F in repairs chromium plated toilet paper holder, complete all as specified.
S&F in repairs chromium plated soap dish, complete all as specified.
S&F in repair plastic water closet seat cover/white closed pattern with flat bottom and cover and mild steel C hinges as per ISI.
S & F in repairsPVC connection pipe of 15mm size with PTMT check nuts with washers of length 450mm, complete all as specified.
S&F in repairs angle valve 15mm dia fancy type chromium plated all as specified and directed by the Engr-n-charge .
S&F in repair 15mm dia CP bib tap fancy type chromium plated .
S&F in repairs PVC mirror cabinet of size 500X400X120mm fancy type fixed with 4 Nos stain less steel clips complete all as specified.
S&F in repair Health faucet, CP brass with 1.50m long flexible pipe 15 mm bore of pipe screwed for iron pipe fancy pipe all as specified and as directed.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing non-metalic rigid PVC conduit medium grade ISI Marked not less than 20 mm dia including all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc by cutting chases and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, suitable fabricated branded modular metal flush box / M S steel terminal boxes duly make embossed, concealed in wall and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular inner and outer cover plates with laminated top sheet cover for housing switches , socket out let and fan regulators etc concealed in walls with suitable , all as specified and as directed for the followings:-
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 51 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through including non-metalic rigid PVC conduit medium grade ISI Marked not less than 20 mm dia including all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc by cutting chases and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, suitable fabricated branded modular metal flush box / M S steel terminal boxes duly make embossed, concealed in wall and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular inner and outer cover plates with laminated top sheet cover for housing switches , socket out let and fan regulators etc concealed in walls with suitable , all as specified and as directed for the followings:-
One light/Exh fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 53 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete.
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1 module / 2 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module / 4 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc. including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately
Supply & fixing in replacement of white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply & fixing in replacement of white cover plate with frame 3/4 module complete all as specified and directed by Engineer in charge.
Supply & fixing in replacement of white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply & fixing in replacement of white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
M&L switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified.
M&L Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified.
M&L switch modular type 6 amp SP two way, 1 module complete all as specified.
M&L Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete.
M&L switch Modular type 16 Amps 1Way, 1 module with modular plat, 230V AC complete.
M&L Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete.
M&L modular stepped type electronic fan regulator 120W, 2 module complete .
M&L Switch piano flush button type single pole one way 6 Amps complete all as specified.
M&L switch piano flush button type single pole 16 Amps complete all as specified.
M&L socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified.
M&L socket outlet 6 Amp flush button type complete all as specified.
M&L regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts.
M&L bell electric (dingdong) 230 volt, SP all complete all as specified and directed .
M/L insulated body, angle holder (metal ring) with back plate complete.
S&F ceiling rose surface PVC type with three terminals complete all as specified and directed .
M&L sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified.
Taking out existing and repair /replacement of Modular mini MCB upto 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
S & F LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
S & F LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
S & F surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S & F 35 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 25 mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S & F LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
S & F LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified.
S&F Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 4 sqmm cable shall be measured as one RM.
S&F Sub main wiring with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 6 sqmm cable shall be measured as one RM.
S&F Sub main wiring with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface/ concealed in walls complete all as specified and directed. Note: Three runs of 10 sqmm cable shall be measured as one RM.
S & F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
S&F MCB DB SPN 02 way, single door 240 V AC 50Hz , with 10 Amps MCB SPN as incomer / out going complete.
S &F MCB DP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F MCB DP 40 to 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S & F MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting .
S & F and Replacement of Ventilating Fan upto 250 mm sweep, not less than 1200 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
S&F and replacement of wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified .
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M&L for opening up the winding of ceiling fan 1200 mm 1400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of Exhaust fan 225/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
M&L for opening up the winding of wall mounted fan 250/300 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Taking down and testing of the wall mounted fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge. (As per sample)
S&F in replacement exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample)
S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers as per sample approved (As per sample) complete all as specified and directed by Edngineer-in-Charge.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor of 1.0 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge.
Supply and fixing only ball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing only ball bearing No. 6203 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Engineer-in-Charge.
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etccomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
S&F Fresh air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250/300 mm size exhaust fan complete all as specified and directed by Engineer-in-Charge.
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge.
M&L for fixing in replacement safety pressure valve (as per sample) for geysers complete all as directed by Engineer-in-charge.
S&F in replacement SS braided pipe of 12 mm (internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge.
S&+E89:H96F heating element of 2 KW,(as per sample) with nut bolt washer complete all as specified and directed by Engineer-in-Charge.
S&F heating element of 1.5 KW (as per sample) with nut bolt washer complete all as specified and directed by Engineer-in-Charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Engineer-in-Charge.
M & L neon lamp/indicator lamp for geysers complete all as specified and directed by Engineer-in-Charge.
M&L plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 3 above) complete all as specified and directed by Engineer-in-Charge.
S&Fin repair&replacement base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
S&F inrepair& replacement outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
M & L in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
Schedule of Credit
M/S Parmod Johar (BID ID -3136772)
POONAM ENTERPRISES (BID ID -3135461)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .