Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹33.2 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹34.4 L+₹1.1 L (3.21%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹35.6 L+₹2.3 L (6.90%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹36.0 L+₹2.7 L (8.22%)Rejected-Finance | 4 | Rejected-Finance Not being the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
29 Jan 2021, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
OUTSOURCING OF SERVICES FOR DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIC SUPPLY LT DISTRIBUTION SYSTEM IN ELSEC NEW DSC LINE, CPDC AREA INCLUDING CONNECTED MAINTENANCE WORKS UNDER GE I RND RCI, HYDERABAD
2020_MES_408389_1
8605
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE I R AND D RCI
MES enlisted Class D category b i and d v Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹74,000
Yes
3 Mar 2021
31 Dec 2020
5 Feb 2021
31 Dec 2020
29 Jan 2021
15 Jan 2021
Amount
Outsourcing of services for day to day routine maintenance of LT distribution system such as internal and external electrification, checking and rectifying faults in internal wiring, sub main wiring, light fittings, bulbs, tubes, switches, sockets, AC sockets, call bells/buzzers, switch boards, fans, regulators, highbay/flood light fittings, building security lights, gate lights, garden lights, fountain lights, DB's, MCBs, MCCBs, switch fuse units, main switches, HRC fuse links, change over switches, LT cables, lugs, glands, LT panels, earthing etc., complete including replacement of unserviceable parts/ components with new spares at ELSEC area by providing One Electrician and One Helper per shift of 8 hours for Two shifts in a day on all days including Sundays and Holidays complete all as specified and directed.
All as per item No 1 above but at New DSC Line and CPDC area by providing One Electrician and One Helper per shift of 8 hours for Two shifts in a day on all days including Sundays and Holidays.
Outsourcing of services for day to day routine maintenance of electrical complaints pertaining to water supply installations, Sewage Treatment Plant and maintenance such as checking of panels, repairs and replacement of parts i.e. HRC fuse links, starters, power contactors, relays, street lights etc., by providing One Electrician and One Helper per shift of 8 hours for One shift in a day on all days including Sundays and Holidays.
Notes for the serial item No 01 to 03: The complaints received from the users duly enclosed in the register with docket number and complaint slip has to be maintained with user signature after satisfactory attending the compliant as a token of completion indicating showing the spares replaced wherever applicable.
All T&P including Hydraulic ladder or aerial access platform mounted on vehicle required for operating, repair and maintenance are deemed to be included in the unit rates quoted.
All stationary for Duty Roster, Attendance register, Wages register, Log sheet book, maintenance record etc., shall be arranged, maintained and submitted by the contractor to Engineer in charge in the first week of every month.
Any loss due to negligence, faulty operation shall be made good by the contractor without any extra cost to the department.
Wage period shall not exceed one month. Wages for all workers employed shall be paid before 7th day of every month through bank account without fail irrespective of whether RAR is claimed or not.
Minimum wages, EPF, ESI, Bonus etc., to the workers shall be paid by the contractor as per Regional Labour/PF Commissioner Gazette Notification including DA all as authorized.
Labour elements for fixing of spares/parts mentioned in this schedule as supply only shall be deemed to include in the unit rate quoted.
The workers employed by the contractor for outsourcing shall be entitled for one day weekly off and the contractor has to provide suitable substitute in the concerned shifts. The unit rate quoted shall be deemed to include for this provision.
Supply only universal batten for fixing T5/T8 LED tube rods with polycarbonate housing complete all as specified. Make: Havells Cat No REGALBATTENT8UPTO1X22 WSSBSWH or techno commercially equivalent of Phillips / Wipro
Supply only ultra bright LED polycarbonate tube light with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders complete all as specified. Make: Havells Cat No PHOTONULTRAE2.01213T8SSTL 20WLED865SPC or techno commercially equivalent of Phillips / Wipro
Supply only 2core 0.5Sqmm PVC insulated, FRLSH PVC round sheathed, flexible copper conductor cable, 1100Volts ISI marked complete all as specified.
Supply only 1.5Sqmm FRLSH PVC insulated, unsheathed, single core, multistranded copper conductor cable, 1100Volts, ISI marked complete all as specified.
All as per item No 7 above but copper conductor cable of size 2.5Sqmm complete all as specified.
All as per item No 7 above but copper conductor cable of size 4Sqmm complete all as specified.
Supply only 3 core 4Sqmm service wire 1100Volts grade, heavy duty with PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified.
Supply only PVC casing & capping with fittings of size 20mm, ISI marked all as specified.
Supply only Capacitor of 2.5/3.15 Mfd 230 volts.
Supply only Capacitor of 4Mfd 230 volts. Make for item No 12 & 13: Epcos/Tibcon/Bajaj/Havells
Supply only Modular Switch 1 way 6Amps, 1 Module, 240V, ISI Marked complete all as specified.
Supply only Modular Switch 1 way 16Amps, 1 Module, ISI Marked complete all as specified.
Supply only Modular Socket, 6Amp, 2/3 pin combined, 2 Module, ISI Marked complete all as specified.
Supply only Modular Socket, 6/16Amps, 2/3 pin combined, 2 Module, ISI Marked complete all as specified.
Supply only ceiling rose three terminal surface bakelite type complete all as specified.
Supply only electronic fan regulator 100watt, 1 module 240V 50Hz complete all as specified.
Supply only modular plastic surfaces box with metal thread inserts suitable for surface/wall mounting, 3 module box complete all as specified.
All as per item No 20 above but 4 module box.
All as per item No 20 above but 6 module box.
All as per item No 20 above but 8 module box.
All as per item No 20 above but 12 module box.
Supply only, Modular white cover plate with frame, 3 module complete all as specified.
Supply only, Modular white cover plate with frame, 4 module complete all as specified and directed.
Supply only, Modular white cover plate with frame, 6 module complete all as specified and directed.
Supply only, Modular white cover plate with frame, 8 module complete all as specified and directed.
Supply only, Modular white cover plate with frame, 12 module complete all as specified and directed.
Supply only MCB, SP, 6 to 32Amp, 10KA, 240volts, ISI marked complete all as specified and directed. Make: Legrand Cat No 4085 87 to 4085 95 or equivalent in Siemens / L&T / IndoAsian C&S / Schneider as approved by GE
Supply only MCB SPN, 40Amp, 240volts, 10KA, ISI marked complete all as specified and directed. Make: Legrand Cat No 4086 18 or equivalent in Siemens / L&T / IndoAsian / C&S / Schneider as approved by GE
c devender reddy and co
Skyline Encon
Indu Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .