Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.3 L+₹20,229.43 (1.54%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹13.5 L+₹34,929.13 (2.66%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹14.7 L+₹1.6 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹16.3 L+₹3.2 L (24.1%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
24 Nov 2021, 6:00 pmClosed
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR / MAINTENANCE OF STREET/ PERIMETER SECURITY LIGHT HIGH MAST LIGHT AND CONNECTED WORKS AT DRONACHAL BHOPAL
2021_MES_484034_1
8655/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bhopal
Class-E, Category b (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
GE Dronachal
₹40,000
Yes
18 Jan 2022
27 Oct 2021
26 Nov 2021
27 Oct 2021
24 Nov 2021
10 Nov 2021
28 Oct 2021 - 9 Nov 2021
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of caste and getting out in Hard / dense soil disintegrated rock.
Returning , filling in including spreading levelling watering and well ramming in layers not exc 25 cm in soft/disintergrated rock
Removing excavated material not exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed
M&L for clean, dry, unwashed sand filled in trenches for cushioning to cable complete all as specified. NOTE:- The depth of cushion after punning shall be measured.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and directed.
Taking down old/ unserviceable UG cable of any description of size upto 50 Sqmm 2/3.5/4 core complete all as directed. Note: (i) Excavation / Earth work , sand & Brick shall be measured and paid seprate under relavent items. (ii) New Cable shall be used if required at site examine and issued under sch B under respective items.
Relaying the serviceable cable taking out from item No 6.00 in same or other places after tracing out the fault with the help of megger and rectifying the defects. Note: (i) serviceable and unserviceable cable stacked seperately (ii) Straight through joint shall be measured and paid seprate under relevent item of schedule.
Laying only in repair XLPE insulated armoured heavy duty electric under ground cable aluminum conductor 1100 volts grade upto 50 Sqmm size 2/3.5/4 core in trenches/on pole through sleeves etc. complete all as specified and directed. Note:- Cable shall be issued under Sch B free for fixing only.
Supply & fix heat shrinkable type straight through cable joint kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 10/16 Sqmm 2/4 core
Supply & fix heat shrinkable type straight through cable joint kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 25/35/50 Sqmm 3.5 core Note for item No 9 & 10 : (i)The suitable excavation shall done by the contractor for making the cable jointing kit and make the cable functional. (ii) Excavation, returning filling and remvoning shall be measured and paid seperately under the relevant items.
M&L for MS flat iron for fabricating of clamp of various size as required at site for mounting/fixing of brackets and junction box on pole
M&L for cutting of bituminous road/ floor for laying of pipe/cables n. exc 1.5m wide and n. exc 1.5m deep including refilling with material and watering Cement concrete work in pavement/hard-standing of flexural strength 40kg/per square centimetre in field using 400 kg of cement per cubic metre,thickness of concrete 25 cm or less complete all as specified and directed.Note-PCC shall measured and paid separately.
Taking out short circuited / burnt out existing aluminium/copper wire and supply & replace weather proof PVC insulated multi stranded copper conductor 1.5 Sqmm flat / round,three core 1100 volts grade complete all as specified and directed.
S&F in replacement of GI Pipe medium grade on road/pole/wall/floor for cable protection with fixing arrangement size 40mm dia.
Demolition of cement concrete/hardcore of any description and in any position not otherwise specifically provided complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed.
M&L for scratching out old bubbled paint, finishing the surface with one coat of aluminium primer & two coats of aluminium paint of 1st quality to street light steel tubuler poles of any height 7/9 mtr , any type (double swan, single swan) all as per site above embedded level, including pole number writting with white colour enamel paint on black colour circular base) with two coat of lime wash on pole coping all as directed by Engr-in-charge.
Material labour fabrication & replacement of street light junction box of size 300 x200 x105 mm inner dimension made out of MS Sheet 2 mm thich with hinged doors, locking arrangements horizontal / vertical operated with 6 amps MCB SP, along with provision of 04 Nos aluminium bus bar of capacity 40 Amps and including 25mm x3mm MS flat iron clamps duly painted with two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed including dismantling of existing unserviceble box.
fixing only in replair of LED Street light fitting of any size and any wattage on electric pole of height up to 9 mtr long alongwith electrical connection and testing complete all as directed by Engr-in-charge. Note:- Street light shall be issued under Sch B free for fixing only
Dismantling/Taking down old LT, over head line of ACSR from PCC/Steel pole. (Note :- Dismentaling of MS work and insulatores shall be removed and paid seperatly)
M&L for repair of LT overhead lines on PCC/steel poles with aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete after dismentling and taking down old ACSR conductor of any size and make, all as specified. Size/make for new conductores Mink/Weasel Note : Measurements for the purpose of payments shall be made by measuring horinzontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.
Taking down old insulator any type and make - from existing over head line and poles/stay after dismantling electrically
M&L for Pin type, porcelain, viterous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade.
M&L for Shackle type, porcelain, viterous white, brown or green insulator including galvanised mild steel straps with section of straps 31 X 3 mm, dia of bolts 12 mm and working pressure 1100 volts of size 75 mm height and 90 mm max dia complete all as specified and directed by Engr-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. and taking down complete
Supply, fabricating , fixing structural mild steel channel angle iron,flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat of aluminium paint complete.(Insulators to be measured and paid for seperately)
Supply and erecting in replacement LT PCC pole 9 Mts long cross sectional area 102 mm x 172 mm at top and 102x279 mm at bottom class 10 complying with requirement of relevant IS and including marking alternate white and black strips 30 cm high each , total of 5 Nos , commencing from the top of PCC coping with two coats of synthetic enamel paint over a coat of primer and writing pole Nos (letters and figures) (Block, Roman, Italic or Indian) of size as directed with synthetic enamel paint complete all as specified and directed. Note:- Excavation and shall be measured and paid for separately.
Supply and fixing GI bracket 1.2 mtr long 40 MM dia complete with MS clamp bolts and nuts for fixing of bracket complete all as specified and directed.
Supply and fix in repalcement of steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate and finial including foundation and coping, painting with aluminium paint complete.
Cutting and Trimming of tree branches touching LT over head lines and trimming of branches in each span of LT over head line complete all as directed Note: (a) The item shall be repeated after three months from the date of first trimming as directed by Engr in charge. (b) Measurement and payment will be made for each cutting/trimming as a job.
Supply and fix in repair LT cable joiniting kit 1100Volts grade cable for indoor/outdoor joint heat shrink type complete with jointing material and accessories suitble for 4 core XLPE armoured aluminium conductor cable of size 10 to 70 sqmm
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 4 Sqmm complete
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 6 Sqmm complete
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed wire, one twin core cable flat 10 Sqmm complete
S&F in repair of Automatic Street Light Switch Three phase with Nature Switch-03 as the controlling unit for automatic switching of street lights based on LUX level of Natural light. The Sensor (Nature switch) along with suitable power contractor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust proof, Electric Shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) confirming to IP54. The contractor, MCB and circuit Wiring should suitable enough to take load 5 KW equally distributed over 3 phase (4 KW/Phase). The contractor rating 25 Amps (4-pole) and MCB(single pole) rating : 20-25 Amps(SP-03 Nos), complete all as specified and directed. Make. Nature Switch Model No SWADEEP-02EC 5 KW3P or equivalent makes in Legrand/L&T/GE.
Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 72 W LED street light fitting including testing complete Make : Bajaj/CG/Phillips /Havells/Wipro
Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 60 W LED street light fitting including testing complete Make : Bajaj/Havells/Halonix/Orient
Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 150 W LED street light fitting including testing complete Make : Bajaj/Havells/Halonix/Orient
Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 35 W LED street light fitting including testing complete Make : Bajaj/Havells/Halonix/Orient
Taking down defective LED driver and Supply and fix LED driver 240 Volts 50 Hz suitable for 25/20 W LED street light fitting including testing complete Make : Bajaj/Havells/Halonix/Orient
M & L for replacement of LED aviation light luminaries comprising of aluminium housing with polycarbonate enclosure with 302 nos LED complete all as per cat no BGAV 302 LED. Make : Philips/Havells/Bajaj complete after taking down the old unserviceable one all as directed.
Taking down,dismantling and necessary repairing of LED street light fittings to make functional by replacing unserviceable part such as PCB, Lens, connector,insulation pad,heatsink, wire connecting terminal etc as existing including refixing of LED street light fittings of any size , type and model on GI tubing bracket to existing pole of any type and any size(like single/double swan neck,straight,PCC/Steel tubular poles of 9/11 mts height) including supply and testing complete all as directed. LED driver shall be paid sepertely under relevant item
M&L for taking down High Mast light fittings mounting on cage from High mast pole of 12.5/16/20 mtrs height for repairing of LED/MH light fitting of any size/type and reinstalling the fitting/cage back to its position after carrying out repairs all as directed by EIC (Cost of LED spare parts will be measure seprately)
M&L for rewinding of existing burnt motor 2 HP of high mast light fitting with replacement winding wire and refixing the same alongwith proper alingment with steel rope etc including electrical connection and testing complete all as directed by Engr-in-charge.
Supply and replacement of Existing High mast panel front door openable with 3.0 mm thickness MS sheet of size 0.9x0.6x0.6m powder coating paint including locking arrangement , Panel internal wiring of suitable size wire alongwith 63 Amp MCCB as incomer and 03 Nos 40 Amps MCB as outgoing and mounting on 40x40x6 mm MS angle and grouted in PCC complete including one coat synthetic enamel paint complete all as per directed by Engr-in-charge
SHOURYA ENGINEERING ENTERPRISES
HRK ENGINEERING CORPORATION
Vinayak Trading House
UMESH ENTERPRISES
M/S RAKESH TRADERS
RAJPATI CONSTRUCTION
MODI CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .