| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
19 May 2021, 4:00 pmClosed
Executive Engineer LRWD
Office of Executive Engineer LRWD, SMC at Old Funds office Building Karan Nagar near National School Municipal Park
PROVIDING EVEVATOR FACILITIES FOR MAYOR OFFICE BUILDING IN CENTRAL OFFICE PREMISES AT KARAN NAGAR
2021_HAUDD_123747_2
NIET NO 04 e-T/2021-22 LRWD SMC
Open Tender
Civil Works
Item Rate
18 days
SRINAGAR MUNCIPAL CORPORATION, KARANAGR SRINAGAR
Please refer to tender documents
2 documents required · 2 mandatory
₹1,200
Yes
FA/CAO Municipal Account No 0216010200000007
Exempted
20 May 2021
4 May 2021
20 May 2021
4 May 2021
19 May 2021
4 May 2021
Amount
PART-A (CIVIL WORKS) Earth work in excavation in foundation trenches or drains (not exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50M from edge of cutting .
Providing and laying Stone solling including compacting, watering including all carriages of material complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1Cement: 4 fine sand: 8 grade stone aggregate 40mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to all levels. 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Crushed.
Centering and shuttering including strutting propping etc. removal of form work a) Foundation footings etc. for mass concrete.
b) Walls
c) Columns
d) Beams
e) Suspended Floors
Supplying, cutting, bending to shape, fabricating, fixing and tying in position TMT Reinforcement Steel at all levels and location as shown in the structural drawing.
Brick work with FPS bricks of class designation 75 in super structure up to all floors. Including carraige of Bricks In cement mortar 1 cement: 6 fine sand mortar.
Providing and fixing in position door/ window /arch windows /ventilator wrought frames (chowkats) Silver Wood
Providing and fixing 40 x5mm flat iron hold fast including fixing of frames with nuts and bolts.
Providing and laying Boulder filling of specified dimensions including all carriages of material complete.
Engagement of Dewatering Pump for dewatering during excavation of work/foundation trenches/ septic tanks/sockage pits,etc including cost of fuel and pump operator, complete job.
Providing and applying average 15 mm thk cement plaster in single coat incement sand mortar 1:4 to all surfaces at all levels including surface preparation, staging, scaffolding as directed.
Lift pit Water Proofing: Cleaning the surface thoroughly, providing and applying Vandex BB 75 waterproofing system in two coats by trowelling as per manufacturer’s specifications. The 1st coat of BB 75 shall be applied to the prepared surface at coverage of 1.5 kg/sqmt. Whilst the 1st coat is still “green” a second coat comprising of Vandex BB75 at a coverage of 1.5 kg/Sqmt. The slurry coatings shall be applied with a stiff masonary brush or stiff broom and worked into every irregularity on the surface shall be done by means of trowelling or by spray only. Treatment to floor slabs shall be carried out by trowel application in 3.0 kg/Sqmt coverage of Vandex BB75 using a steel trowel into hardenced concrete slab surface including curing, cleaning etc complete.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.
Providing and applying Wall putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Strctural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer in Plates/ angles / flats / tubes / channels for Lift Tower, etc all complete.
Providing and fixing of G.S powder coated High Rib sheet roofing including cost of screws, etc in roofs, walls, gables, etc complete as per directions of engineer in charge.
Providing and fixing of 10mm thick Ready made wooden Panneling in sofits including cost of screws, etc in Softs, walls, gables, etc complete as per directions of engineer in charge.
Providing and fixing of Powder coated ridges or hips of width 45cm over all width plain G.I sheet fixed with nails.
Providing and fixing of planed ornamental eaves boarding 250mm x 25mm size of 1st Class Budloo wood.
Finishing with Epoxy paint (Two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete on all surfaces.
Providing and fixing in position collapsible steel shutters with vertical channels and braced with flat iron diagonals with top and bottom rail of T -iron, steel pulleys complete with bolts, nuts, locking arrangement, toppers, handles, including applying a priming coat of approved steel primer,
Providing and fixing of 4.50mm thick ACP of specified colour, design, dimensions & pattern including all frame work of steel/ aluminium of specified size at specified spaces including scaffolding complete job as per directions of Engineer incharge.
PART-B (LIFT/ MECHANICAL WORKS) Design , Supply , Installation , Testing and Commissioning of Passenger Elevator (G+3 & Passenger 10 No's) including system control panel including all necessary Chanelles/Gauders and all other accessories complete Technical Parameters are attached and need to be filled by the bidder. Note: AMC should be for 03 years post normal one years of warranty. The period of this maintenance shall commence from the date of handing over of the lift. Technical Specifications for 10 Passenger Elevator (Lift) (G+3) MR are as under below.(24.01 TO 24.34) NOTE: THE QUANTITY FROM (S.NO. 24.01 TO 24.34) REPRESENTS NULL VALUE
Capacity / Load: 10 Persons (Gear Less MR)
Speed(m/sec): 1 mps
Type of drive: AC VVVF
Rise (m): as per site requirement
Number of Landings : 4
Number of Openings : 4
Entrance: Double Sided
Controller type: MRL, AC VVVF
Power Supply: 400/415 Volts 3Phase, 4 wire
Car group : One car
Machine:PM Gearless ( located in Shaft on top of guide rails)
Ventillation:Cross flow fans or eq. having concealed vents
Hoistway/ Car entrance door: Centre opening, Glass doors with SS Hairline finish or eq.
Traction Medi: Rope or eq.
Operation: Automatic
False ceiling Type: SS as per manufacturer
False ceiling Finish: Stainless steel
Hand rails: Stainless steel Mirror Finish on all sides of car Panels or eq.
Flooring: Vinyl or eq.
Car door finish: Glass doors with SS Hairline finish or eq.
Landing door finish:Glass doors with SS Hairline finish or eq.
Car & Hoistway Door : Central Operating (CO) doors
Lift Manufacturer: Otis, Schinder, Thyssen Krupp, Escon, Omega or Asus Elevators
Rate of acceleration/: 0.6-1.5 (adjustable at site)
Jerk (m/sec3): 0.7-1.5 (adjustable at site)
Vibrations in car : 20/18 MG maximum
Noise level in car: 45 dBA maximum
Standard Features: Anti-nuisance Car Call Protection, Security Camera as desired, Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off and Automatic Rescue Operation/ DC door operator, Music (Speaker)
COP (Cabin Operating :Stain less steel
Car position indicator/Hall button arrangements: LCD Monochrome Dot matrix multi color or eq. having dynamic car direction display, Visual Overload warning indicator
ARD (Automatic Rescue :To be provided
Associated Civil and structural items: All civil and structural items of work associated with erection and operation of lifts shall be provided by contractor including but not restricted to the following: a) Temporary Scaffolding and safety barricades for erection in and around lift hoist ways b) Bearing plates c) Buffer supports d) Facia plates e) Ladder in pits f) Safety railing on top of car g) Channels, separators, stretchers etc. Note: Site has to be visited by the bidder before filing tender
Fireman's switch: To be provided at GF/ Lobby
PART-C (ELECTRICAL WORKS) Providing and fixing of 8 way Double door distribution Board of Hager/Legarnd/ Siemens make
Providing and fixing of Heating points for lift using 4 sq.mmPVC insulated copper wire of FRLS(Polycab, Finolex, Havells make). through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Havells/ Philips/Legrand make Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire of Havell’s, Polycab, Finolex make or equivalent as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects
Wiring for circuit (lift)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required (Finolex, Havells, Polycab make) Note : Rates of Suitable PVC conduit included in above description for the follwing items of (Finolex, Anchor, Alba,, Flair) make 4 X 10 sq. mm + 1 X 10 sq. mm earth wire
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links of ABB,Siemens, Legrand make for lift 125 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 Amp 4 P MCCB
Supply, Installation, Testing and Commissioning of 15 KVA servo stabilizer Digital Microcontroller Buck booster Servo Voltage Stabilizer out-door Radiator type (230 V to 460 V input and 415 V Out put) of with fresh dehydrated oil. With protection, complete in all respects. 1. High - low voltage Cut/ over current protection System 2. Cooling:- Oil Cooled 3.. Time delay. AE/ Electric field/ Servo volt as per required specification
Providing/fixing of Manual change-over 4P TYPE, Hinged type single door, surface type 100 Amp of Hager/ Legrand/ Havells make
Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. Havells/ Finolex 35 sqmm 3 1/2 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 3½ X 35 sq. mm (32mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber taken upto Main Panel
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (DSR 5.14)
Providing of Earthing with G.I. earth plate 600mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.including Sutiable connectivety up to installation to be earthed
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single Pole
b) Double Pole
PARVEZ AHMAD DARZI
M/S SRINAGAR GROUP OF ENGINEERS
stage.html
html • 0.02 MB
finance_240910.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .