ED Budgam, KPDCL
Creation of 250 KVA sub station along with HT LT Network for newly constructed 2 BHK Residential Accommodation for PRI protected Persons at Sheikhpora Budgam
2023_PDD_240360_1
EDB/128 of 2023-24
Open Tender
Electrical and Maintenance Works
Turn-key
45 days
ED Budgam, KPDCL
As per SBD
7 documents required · 7 mandatory
₹1,000
Executive Engineer, ED Budgam, KPDCL
₹20,700
1 Jan 2024
16 Dec 2023
30 Dec 2023
16 Dec 2023
29 Dec 2023
21 Dec 2023
17 Dec 2023 - 20 Dec 2023
Amount
Work items identified;
Supply, Installation ,testing and Commissioning of 250 kVA 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper wound and with LV Cable Box having detachable Aluminium Gland plate
Supply, installation, testing and commisioning of 9 mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm) with 50 mm dia hole, top cap, Earthing Channel(75x40x6mm) including digging of pit positioning etc, complete in all respect as per Standards.
Supply, installation, testing and commisioning of 8 mtr(410 SP-15) long Steel Tubular Poles complete with base plate(350x350x5mm) with 50 mm dia hole, top cap, Earthing Channel(75x40x6mm) positioning etc, complete in all respect as per Standards.
Supply, laying, stringing, tensioning, binding of 50 Sqmm ACSR Conductor complete in all respects as per standards.
Supply, laying, stringing, tensioning, binding of 30 Sqmm ACSR Conductor complete in all respects as per standards.
Supply,Carraige upto site and fixing of GI V cross-arm with top Bracket including clamp duly fabricated as per site requirement including clamps(50x8 mm), GI Nuts & Bolts,washers etc complete in all respects as per standards.
Supply,Carraige upto site, fixing and installation of GI Channels of different sizes including clamps and braces.
Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Pin Insulators 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete in all respects as per standards.
Supply and fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete in all respects as per standards.
Supply,Carraige upto site,Installation,testing and Commissioning of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of Gapless Surge Arrestor 9 kV, 10 kA, LA with polymer housing, Stn. Type complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV G.O AB Switch 3-phase, 3 pole 200-Amp, vertical Type with fittings complete in all respects as per standards.
Supply, Carraige upto site, installation, testing and Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A complete in all respects as per standards.
Supply, Carraige upto site, laying, stringing, tensioning, binding of 240 mm² (2Ckt )1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type cable complete in all respects as per standards.
Supply,Carraige upto site, fixing of Aluminium Thimbles of size 1240 Sqmm.
Supply,Carraige upto site, fixing and Commissioning of Aluminium Solderless Clamps of size 240 Sqmm.
Supply, Carraige upto site, installation, testing and Commissioning of LT Distribution Box for 250 kVA DTR with 400 MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No.s and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits..complete in all respects as per standards.
Earthing of substation-Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 25 mmx3 mm, for connection of transformer body,G.O set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover complete in all respects as per standards.
Supply,Carraige upto site, fixing of G I Muky Clamps. As per standards
Supply,Carraige upto site, fixing of 45 KN Shackale insulators as per standards.
Cement bottoming 1:2:4 mix as per Standards 0.5cum/0.45 cum pole comlete in all respects.
Earthing of steel tubular poles complete by GI pipe 40mm or GI rod 20mm 3.0 mtr long through GI strip 25x3 as per standards.
Painting of Poles with one coat of Red Oxide and two coats of alimunium paint to give uniform shine.
Supply and fixing of GI barbed wire Anti climbind Device with clamps complete in all respects as per Standards
Supply and fixing of danger plates with clamps complete in all respects as per Standards
Three Phase Whole Current Trivector meter (Prodigi)
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR Creation of 250kVA/ new Substations along with HT/LT network under the jurisdiction of ED Budgam, KPDCL.
ALMUSTAFA INFRASTRUCTURE AND BUILDERS Pvt Ltd
M/S NICE ELECTRIC SOLUTION
M/S WANI ELECTRA & SUPPLIERS
M/S TAQWA ENTERPRISES
M/S G E C ELECTRICALS
Alamdar Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .