Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹1.7 L+₹10,106.50 (6.27%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L2 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | MAHIMA CONSTRUCTION L2 | ROYAL WORKS ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | M&L for point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, ISI marked, FRLS type drawn through and including PVC casing and caping (ISI marked) of adequate size and its accessories with PVC boxes of adequate size, with modular cover plate with frame of adequate required modules for one light or one fan point controlled by one switch including 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for one light point and one fan point controlled by one, one way swtich. | 16 | Point | 450 ₹7,200 Lowest | 660 ₹10,560 |
| 2.00 | S&F of switch modular type 6 Amps one way, 1 module, AC 230 Volts, shrouded terminal, ISI marked complete all as specified and directed. | 16 | Each | 54 ₹864 | 36 ₹576 Lowest |
| 3.00 | S&F ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish. | 16 | Each | 27 ₹432 | 25 ₹400 Lowest |
| 4.00 | S&F exhaust fan 450 mm sweep, 1400 RPM, single phase, heavy duty, fixing on mounting frame, including cutting round hole in stone masonary wall 380 mm thick and inserting appropiate size and thickness PCC squre/round exhaust frame/vent making good the disturbed surfaces, fixing by means of rugged bolts, nuts and washers etc on the square/round vent/frame inserted in wall and connecting with three core copper conductor flexible cord of 1.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply including GI louver shutters complete all as specified and as directed. | 12 | Each | 6,732 ₹80,784 | 5,350 ₹64,200 Lowest |
| 5.00 | S&F of energy efficient LED Street /Roadway with PDC housing luminaire, high PF, 70 - 72W, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, clear toughned glass / Polycarobonate Sheet, IP 66 protection, 4 kV inbuilt surge protection, 240 Volts, 120 lumens/Watt, colour temp. 5700K, Cat Part No ENXT P84L WH PO PC SD MT of Bajaj or techno commertially equivalent (as per list of makes) complete all as specified and directed. | 4 | Each | 2,700 ₹10,800 | 700 ₹2,800 Lowest |
| 6.00 | S&F of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type, cables 1.5 Sqmm drawn through in and including PVC heavy duty surface casing caping including 1.5 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed.
Note :- (i) Two runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main.
(ii) PVC casing caping and its accessories is deem to be included in this item rates.
(iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc. | 30 | RM | 102 ₹3,060 Lowest | 122 ₹3,660 |
| 7.00 | S&F brackets made out of 40 mm bore GI pipe, light grade, 1.0 m long, bend to shape and including suitable GI clamps made out of 40x6 mm flat iron, necessary GI bolts, nuts, washers etc complete all as specified and directed. | 4 | Each | 207 ₹828 Lowest | 600 ₹2,400 |
| 8.00 | S&F inverter spilt air conditioner electric driven single phase of capacity 2 TR, BEE 5 Star rated (latest) with ISEER 5 W/W complete with control remote, stranderd copper cable of appropirate size of 3 m length up to power point, initially filling of refrigernat and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commision as recommended and directed. Specification of air conditioner is as under :
Tonnage : 2 TR
Refrigerent Gas : R 32 (Non CFC)
Power Supply : 230 Volts/50Hz single phase, wide operating voltage range 145 to 270 V.
Condensor Coil : Copper
Connected pipe : 5 m
Rated cooling Cap : 6050 Watt
Connected Cable : Copper with appropriate size 3 m
Air Flow Volume indoor : 950 (CMH) | 1 | Each | 45,459 ₹45,459 Lowest | 60,000 ₹60,000 |
| 9.00 | S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including digital display and time delay system and of capacity 4 kVA. | 1 | Each | 5,400 ₹5,400 | 5,200 ₹5,200 Lowest |
| 10.00 | S&F distribution box MCB protected Socket PVC base. | 1 | Each | 1,800 ₹1,800 Lowest | 2,000 ₹2,000 |
Tender Value
₹1.8 L
EMD Value
₹3,650
Closing Date
24 Feb 2026, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender documents
2026_MES_751016_1
GE/NRC/8772/E8
Open Tender
Civil Works
Item Rate
60 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹300
Garrison Engineer Nasik Road
₹3,650
Yes
10 Mar 2026
3 Feb 2026
26 Feb 2026
3 Feb 2026
24 Feb 2026
17 Feb 2026
M&L for point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, ISI marked, FRLS type drawn through and including PVC casing and caping (ISI marked) of adequate size and its accessories with PVC boxes of adequate size, with modular cover plate with frame of adequate required modules for one light or one fan point controlled by one switch including 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for one light point and one fan point controlled by one, one way swtich.
S&F of switch modular type 6 Amps one way, 1 module, AC 230 Volts, shrouded terminal, ISI marked complete all as specified and directed.
S&F ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish.
S&F exhaust fan 450 mm sweep, 1400 RPM, single phase, heavy duty, fixing on mounting frame, including cutting round hole in stone masonary wall 380 mm thick and inserting appropiate size and thickness PCC squre/round exhaust frame/vent making good the disturbed surfaces, fixing by means of rugged bolts, nuts and washers etc on the square/round vent/frame inserted in wall and connecting with three core copper conductor flexible cord of 1.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of exhaust fan suitable on working AC, SP 230 V electric supply including GI louver shutters complete all as specified and as directed.
S&F of energy efficient LED Street /Roadway with PDC housing luminaire, high PF, 70W, energy saving and environmental friendly long life versatile pressure die cast aluminium housing, clear toughned glass, IP 66 protection, 4 kV inbuilt surge protection, 240 Volts, 120 lumens/Watt, colour temp. 5700K, of Cat Part No ENXT P84L WH PO PC SD MT of Bajaj or techno commertially equivalent (as per list of makes) complete all as specified and directed.
S&F of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type, cables 1.5 Sqmm drawn through in and including PVC heavy duty surface casing caping including 1.5 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of cables and one run of continuous earting cable drawn in casing and caping will be measured as one length of sub main. (ii) PVC casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for sinking for boxes and making good to wall, floors etc.
S&F brackets made out of 40 mm bore GI pipe, light grade, 1.0 m long, bend to shape and including suitable GI clamps made out of 40x6 mm flat iron, necessary GI bolts, nuts, washers etc complete all as specified and directed.
S&F inverter spilt air conditioner electric driven single phase of capacity 2 TR, BEE 5 Star rated (latest) with ISEER 5 W/W complete with control remote, stranderd copper cable of appropirate size of 3 m length up to power point, initially filling of refrigernat and installation of outdoor and indoor unit ((without fixing bracket) with suitable size of inlet and outlet copper tubing with proper insulation with required size and length, fixing drain pipe making hole on wall, testing the same after commision as recommended and directed. Specification of air conditioner is as under : Tonnage : 2 TR Refrigerent Gas : R 32 (Non CFC) Power Supply : 230 Volts/50Hz single phase, wide operating voltage range 145 to 270 V. Condensor Coil : Copper Connected pipe : 5 m Rated cooling Cap : 6050 Watt Connected Cable : Copper with appropriate size 3 m Air Flow Volume indoor : 950 (CMH)
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% including digital display and time delay system and of capacity 4 kVA.
S&F distribution box MCB protected Socket PVC base.
M&L submain wiring with two single core PVC insulated unsheathed FRLSH type, multistranded flexible copper conductor 1100 Volts grde cables 2x4 Sqmm drawn through in and including rigid PVC heavy duty connected conduits including 4 Sqmm 1100 Volts grade PVC insulted unsheathed multi stranded, FRLSH type flexible copper conductor cable continuous earth wire and connecting to common earth terminals complete all as specified & directed
S&F sheet metl enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
8772PS.pdf
Tender Documents • 0.23 MB
BOQ_841130.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .