Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹35.8 LAccepted-AOC | L 1 | Accepted-AOC Being lowest bid and EAS Accepted by TC | |
| 2 | L 2₹37.8 L+₹95,675 (2.60%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L 2 | Rejected-Finance Other than L1 | |
| 3 | L 3₹44.4 L+₹7.6 L (20.6%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L 3 | Rejected-Finance Other than L1 | |
| 4 | L 4₹46.5 L+₹9.7 L (26.3%)Rejected-Finance | L 4 | Rejected-Finance Other than L1 |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
13 Sept 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE EAST LUCKNOW PIN 226002
SPL REPAIR UPGRADATION OF ELECTRIC WIRING IN BLDG NO P39 TO P46 48 X JCO/OR MD ACCN AT SHEA LINE AND SPL REPAIR/REPLACEMENT OF LT PANEL AND UNDERGROUND XLPE CABLE ST BARABANKI UNDER GE EAST LUCKNOW
2024_MES_666396_1
GE/E/LKO/T-37 OF 2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (EAST) LUCKNOW
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE (EAST) LUCKNOW
₹96,400
Yes
9 Oct 2024
18 Jul 2024
20 Sept 2024
18 Jul 2024
13 Sept 2024
2 Aug 2024
Amount
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 02 here-in-before but one bell point controlled by one bell push, 06 Amp.complete all as specified and directed.
All as per serial item No 02 here-in-before but one, two way light point controlled by two, two way switches, 06 Amp.complete all as specified and directed.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on independent board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per serial item No 02 here-in-before but one 3 pin, 06 Amp socket outlet point on same board controlled by one, one way switch 06 Amp.complete all as specified and directed.
All as per Serial Item No 02 here-in-before but point wiring with 2.5 Sq mm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 16 Amp socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed
S&F Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed
S&F Modular White cover plate with frame,12 module complete all as specified and as directed
S&F Modular White cover plate with frame,8 module complete all as specified and as directed
S&F Modular White cover plate with frame,3 module complete all as specified and as directed
S&F Modular White cover plate with frame,2 module complete all as specified and as directed
S&F Modular Metal flush box 12 module complete all as specified and as directed
S&F Modular Metal flush box 8 module complete all as specified and as directed
S&F Modular Metal flush box 3 module complete all as specified and as directed
S&F Modular Metal flush box 2 module complete all as specified and as directed
S&F Calling bell , AC, 230 Volts, modular type multi music single phase complete all as specified and as directed
S&F Bell push , AC, 230 Volts, 2 module complete all as specified and as directed
Supply and fix fan step regulator, 120W 2 module complete all as specified and as directed
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
Supply and fix in replacement of decorative wall mounting type LED light fitting, 1 x 15 Watt, 230 Volt made up of Polycarbonate including shade, lamp holder, 9/10 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and directed.
Supply and fix in replacement of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover, etc complete all as specified and directed.
Supply and fix LED tube light fittings 1200 mm, 20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply and fix LED tube light fittings 600 mm, 10 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed.
Supply & fix LED wall/surface mounted down lighter, 12 W including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories complete all as specified and directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Taking down carefully ceiling fan of any sweep complete with all accessories, dismantling blades and deposit in safe custody of AGE E/M Yard-II for BER procedure complete all as specified & directed.
Material and labour for sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete all as specified & directed.
Supply and fix in replacement of AC modular box SPN plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board, double door, single pole and neutral, AC, 240 volt, 08 way, with 200 Amp rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fix in replacement of sheet metal enclosure distribution board triple pole and neutral (VTPN),double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed and comprising of the following:- (a) MCCB, 125 Amp, 04 pole, AC, 415 Volt of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volt of 06 to 32 Amp, "C" curve, 10 KA breaking capacity - 12 Nos.
Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB, DP, AC, 240 volt of 32 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. by Engr-in-Charge
S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed.
S&F exhaust fans, plastic body, ac, single phase, 230/240 v of size 200 mm sweep with louver and making connection with twisted copper flexible wire 23/0.076mm complete all as specified and directed.
Supply and fixing in replacement LED Bldg security light fitting LED 45 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket protection complete all as specified and directed and directed
Cutting walls any type, making holes for fixing of exhaust fan of any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed
Taking down electric meter and refixing on same board after rewiring all complete all as specified and directed.
Supply only LED bulb 9/10 Watts suitable for B22 white in colour complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer on walls with 1 mm thick putty after complete removal of existing treatment complete all as specified and directed. by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 4.0 core complete all as specified and directed.
Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying unserviceable of pipes/cables etc getting out and bottom surface to required gradient complete all as directed & specified
M&L for Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and as directed
M&L for Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed
M & L sand cushioning for under ground cable 23 cm thick (one layer of 8 cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed ( Note:- punned down thickness 18 cm shall be considerd for mesurement/ payment)
M&L Old size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement of 35 Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 50 Sqm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 70Sqmm 3.5 Core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, on pole complete all as specified and directed
Supply, laying, jointing, testing and commissioning in replacement of 120 Sqmm 3.5 core cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches,on pole complete all as specified and directed
Supply and fix of Aluminium Lugs uitable for 16 to 35 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed .
Supply and fix of aluminium Lugs suitable for 70 to 95 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed.
Supply and fix of Aluminium Lugs suitable for 120 to 185 Sqmm 1100Volts including taking down old unserviceable lugs, complete all as specified and directed .
Supply and fixing in replacment GI pipe light grade 40 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking up old GI pipe complete all as specified and directed.
All as per ser item No 60 here-in-before but size 50 mm dia
Supply and fixing GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah complete all as specified and directed
Taking up old exiting 80 mm GI Pipe complete all as specified and as directed
Supply installng, testing and commissioning floor mounted LT panel out door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.00 mm thick appropriate size of panel 1.2 x 1.2 x 0.45 M and angle iron frame of 40x40x6mm and 04 Nos legs on angle iron 50x50x6mm each 45 cm long panel duly powder coacted in side and out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under.(i) Aluminium bus bar strip of capacity 250 amps fixed on epoxy insulator - 04 Nos (ii) Incomming MCCB of current rating 160 Amps with adjustable thermal release 4 pole 415 volts 36 KA repturing capacity - 01 Nos.(iii) Out going MCCB of current rating 100 Amps with adjustable thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos.(iv) Out going MCCB of current rating 63 Amps with adjustable thermal release 4 pole 415 volts 16 KA repturing capacity - 02Nos.(v) Out going MCCB of current rating 63 Amps, 4 pole, 415 volts AC, 16 KA adjustable thermal release rupturing capacity - 01Nos.(vi) Digital voltmeter (0-500 volt) 96x96mm (vii) Digital ampmeter (0-600 amps) 96x96mm incl with CT,s (viii) Set of phase indicator lamp R,Y,B with control MCB - 01 Set complete all as specified and as directed
M & L for earthing incl eath work complete with galvanised steel earth plate electrode 60x60x6.0mm thick burried directly in ground ( earth pit not less than 2.25 meters deep below ground level) with to edge of the plate not less than 1.5 Mtrs below normal ground level connected to galvanised earth lead 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by GI pipe all as shown in electrical pate No 5 of SSR Part I - 2009 connected to earthing test point all as specified and indicated including excavation earth work PCC chamber RCC chamber cover protection pipe watering pipe funnel and testing on completion all as specified and directed. (Note: Earth strip and protection pipe upto 7.50 m length is included in the unit rate)
M&L for LT straight through 1100 volt grade for cable for heat shrink type joint kit complete with jointing material and accessories suitable for 4 core 25 to 50 sqmm XPLE armoured aluminium conductor cable complete all as specified and as directed.
M&L for LT straight through 1100 volt grade for cable for heat shrink type joint kit complete with jointing material and accessories suitable for 4 core 70 to 120 sqmm XPLE armoured aluminium conductor cable complete all as specified and as directed
M&L for LT straight through 1100 volt grade for cable for heat shrink type joint kit complete with jointing material and accessories suitable for 4 core 150 to 185 sqmm XPLE armoured aluminium conductor cable complete all as specified and as directed
QUALITY CONSTRUCTIONS CO (BID ID -3089308)
M/s A.K Construction (BID ID -3094756)
m/s raghubar dayal (BID ID -3092554)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .