PROVN OF DEFICIENT TOILET BLOCKS AND BATHROOM BLOCKS ALONGWITH SEPTIC TANK AT Z GALI UNDER GE 874 EWS
2023_MES_632183_1
CWEK-59/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 874 EWS
Class B Category a i
6 documents required · 6 mandatory
₹1,000
GE 874 EWS
₹1.9 L
HQ 133 WORKS ENGRS
24 Apr 2024
11 Dec 2023
28 Feb 2024
11 Dec 2023
20 Feb 2024
7 Feb 2024
11 Dec 2023 - 22 Dec 2023
23 Dec 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil for roads to required slope gradient, camber etc Complete all as directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cable, pole foundation, stay, laying of pipe etc not exceeding 10 sq m on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil Complete all as directed by Engineer-in-Charge.
Excavation over area not exceeding 1.5 m deep and getting in any type soil Complete all as directed by Engineer-in-Charge.
Rough Excavation not Exe 1.5 mtr deep and grttig out in soft and loose soil Complete all as directed by Engineer-in-Charge.
Rough Excavation Exe 1.5 mt n exe 3 mtr deep and gettig out in soft and loose soil Complete all as directed by Engineer-in-Charge.
Rough excavation not exceeding 1.5 m deep and getting in any type soil Complete all as directed by Engineer-in-Charge.
Returning filling in including spreading leveling watering and well ramming in layers n exc 25cm Complete all as directed by Engineer-in-Charge.
Removal of excavated materials n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point Complete all as directed by Engineer-in-Charge.
Removing excavated material to a distance exc 250M but not exc 500 and depositing where directed Complete all as directed by Engineer-in-Charge.
Construction of 50 users conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter Complete all as directed by Engineer-in-Charge.
Construction of soakage well (brick masonry) of 1.2m internal dia and 3.00m deep below inlet level incl necessary earth work, filling with brick bats of gauge 40 to 80mm, SWG inlet pipe junction 150mm bore including all other relevant works, Complete all as directed by Engineer-in-Charge and shown on drawing No.CESZ/TD-1104/2015.
Supply and laying DWC pipes ( Double wall corrugated) of class SN-4, IS-16098 (Part-II) of size internal dia of 150 mm, laid in trenches and jointed complete with coupler,bends,tee, reducers etc Complete all as directed by Engineer-in-Charge.
M & L hardcore of broken stone or boulders of gauge n.exc.63mm,deposited,spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface Complete all as directed by Engineer-in-Charge.
M&L cement concrete 75mm thickness in foundation type C 2, 1:3:6 ( 40 mm grade stone aggregate) as in filling and mass concrete Complete all as directed by Engineer-in-Charge.
M&L 60mm thick, machine pressed precast concrete interlocking paver block, with grey cement and pigment, any shape and size confirming to IS 15658-2006, M-35 Grade Complete all as directed by Engineer-in-Charge.
M&L for 25 mm sand cushion under paving block including watering and consolidation for interlocking tiles Complete all as directed by Engineer-in-Charge.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in benching including necessary form work etc Complete all as directed by Engineer-in-Charge.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, and other similar bands,plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, kneelers, apex stone,bed plates and the like including weathering slightly rounded or chamfered angles and throating, Complete all as directed by Engineer-in-Charge.
M&L cement concrete type C-1 (1:3:6) using 20mm graded stone aggregates as, in lintels upto 1.5 m clear span, oils, steps; seismic and other similar bands, plinth courses, string courses, lacing courses parapets and railings upto 60 cm in height, copings kneelers, apex stones bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc Complete all as directed by Engineer-in-Charge.
M&L Precast cement concrete B1 type, (1:2:4) using 20 mm graded aggregate in landings cover slabs (for manholes etc.) chullah, hoods, chajjas, water troughs mangers, shelves and similar articles with plain faces with set in cement mortar 1:6. etc Complete all as directed by Engineer-in-Charge.
M&L for plain Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) in sub base filling and mass concrete Complete all as directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. Complete all as directed by Engineer-in-Charge.
M & L for Walling of random rubble uncoursed , brought upto courses well bonded, bedded and solidly hearted built in CM 1:4 Complete all as directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B - 1 ( 20 mm graded aggregate) as in bands, coping, bed plates etc Complete all as directed by Engineer-in-Charge.
M & L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in bond stone (for stone walling ) and set in cm 1:4 Complete all as directed by Engineer-in-Charge.
Extra over walling hammer dressing with mix depositing on face from straight edge held against the dressed surfaces n exc 40mm Complete all as directed by Engineer-in-Charge.
M&L pointing to random or polygon rubble, uncoursed or brought upto course in CM (1:3) Complete all as directed by Engineer-in-Charge.
M & L boulder filling and hand packing tightly, as in vertical bonds with sloping faces Complete all as directed by Engineer-in-Charge.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvves including sup-ports, overhangs, etc. also splays between floors and beams, etc finish with rough finish flat surface Complete all as directed by Engineer-in-Charge.
M&L Fe -410-W(gde-E-250) Quality A Roof trusses (framed), trussed, purlins, rafters etc, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Complete all as directed by Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and Complete all as directed by Engineer-in-Charge.
M&L for 15mm thick rendering on fair faces of brick work/concrete surfaces in CM 1:4 finishing the surface fair & even (without using extra cement) Complete all as directed by Engineer-in-Charge.
M&L for rendering 15 mm thick in CM (1:4) on other than fair faces of brickwork or concrete surfaces etc Complete all as directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls mixed with WPC 3% by weight of cement finished even & smooth without using extra cement. etc Complete all as directed by Engineer-in-Charge. Note:- WPC shall be measured and paid separately
Supply only Integral water proofing compound Complete all as directed by Engineer-in-Charge.
M&L for preparing newly plasterd surfaces of wall including priming the plastered surfaces and applying two coats of cement based paint Complete all as directed by Engineer-in-Charge.
M&L Brick work with sub class 'B' brick straight or curved on plan exc 6m mean radiaus built in cement mortor 1:6 Complete all as directed by Engineer-in-Charge.
M&L brick work with subclass 'B' bricks straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar 1:4 etc Complete all as directed by Engineer-in-Charge.
M&L for brick work with sub class B bricks on plan to any radius in half brick thick wall built in CM 1:4 Complete all as directed by Engineer-in-Charge.
M&L for 10mm thick cement plaster in CM 1:4 other than fair faces of brick work or as a screed bed for vertical surfaces of wall Complete all as directed by Engineer-in-Charge.
M&L for 15mm thick rendering on fair faces of brick work/concrete surfaces in CM 1:6 finishing the surface even and smooth Complete all as directed by Engineer-in-Charge.
Supply and fixing 10 mm dia and over mild steel TMT bars, cut to length, bent to shape required cranking bending and binding with and including mild steel wire annealed not less than 0.90 mm dia. Complete all as directed by Engineer-in-Charge.
All as specified in item No 44 above here in before but 8 mm dia as in stirups Complete all as directed by Engineer-in-Charge.
M&L RCC (nominal mix) Type B0 1:2:4 (12.5mm graded aggregate) as in Slabs supported on walls, beams and columns in floors ,roofs, landings, balconies,canopies,deck slabs and in shelves and the like. Complete all as directed by Engineer-in-Charge.
M&L RCC (nominal mix) Type B0 1:2:4 (12.5mm graded aggregate) as in beams, lintels, cantilever etc supported on walls, beams and columns and like Complete all as directed by Engineer-in-Charge.
Form work to soffits of suspended slab, roof beam haunching grider bressumers , lintels such as roof slabs, floor slabs, landings and similar work, n exc 200mm thick (Horizontal or sloping) Complete all as directed by Engineer-in-Charge.
M&L for 75 mm thick plinth protection in/Subbase PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) Complete all as directed by Engineer-in-Charge.
M&L for 25mm thick cement concrete type B-1, 1:2:4 as in sub base under floor and finished rough surface Complete all as directed by Engineer-in-Charge.
M&L for 15 mm thick screed bed in cement mortar 1:6 for laying floor finishes Complete all as directed by Engineer-in-Charge.
M&L for Glazed ceramic tiles in vertical surface 300X200X7 mm thick set and jointed in neat cement slurry and pointed in colour cement to match Complete all as directed by Engineer-in-Charge.
M&L Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm and n.exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface, Complete all as directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws Complete all as directed by Engineer-in-Charge.
All as per item No 55 above herein before but plain sheet Complete all as directed by Engineer-in-Charge.
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. Complete all as directed by Engineer-in-Charge.
S&F sheet glass 5.5 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane Complete all as directed by Engineer-in-Charge.
S&F soild PVC door frame of size 50mm x 47mm made out of 5mm plaint colour PVC sheet reinforced with MS square tube, and fitted in opening Complete all as directed by Engineer-in-Charge.
M & L for mild steel hold fast of flat Iron size 25mm x 3mm thick for PVC door chowkhat etc Complete all as directed by Engineer-in-Charge.
S&F factory made solid PVC moulded door shutter with particle board core 28 to 30mm thick (style) with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specificating and drawing Complete all as directed by Engineer-in-Charge.
S&F Vitreous China squatting pan "Orissa Pattern" size 580 x 440mm ISI marked white with integral foot rests etc Complete all as directed by Engineer-in-Charge.
S&F for 100mm long stainless steel butt hinges medium weight cold rolled all as specified and directed by Engineer-in-Charge.
M&L for Aluminium handles cast type anodised 100mm long Complete all as directed by Engineer-in-Charge.
M&L M&L for Aluminium alloy, anodised sliding door bolt 200mm long Complete all as directed by Engineer-in-Charge.
Mild steel butt hinge medium weight cold rolled 75mm size Complete all as directed by Engineer-in-Charge.
S&F Mild steel pressed handle, oval ltype stove enamelled, black size of handle 150mm Complete all as directed by Engineer-in-Charge.
Mild steel tower bolt stove enmelled black 150mm long black with bright bolt and fixed Complete all as directed by Engineer-in-Charge.
M&L preparing newly plasterd surfaces and applying three coats of white wash on wall etc Complete all as directed by Engineer-in-Charge.
Vitreous china bowl urinal flat back, of size 465x355x265mm white (minimum), with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including discharge pipe of PVC 32mm dia Complete all as directed by Engineer-in-Charge.
S& F PVC reducer couplings fixed at outlet of urinal pot incl. suitable length PVC flexible pipe 25 mmdia . ( Minimum weight 32 mm-45 gms) Complete all as directed by Engineer-in-Charge.
S&F 1000 Ltrs capacity rotational moulded polyethylene water storage tanks (Cylinderical vertical with closed top) ISI marked and fixed in position, all as specified in SSR Part-I, Complete all as directed by Engineer-in-Charge.
M&L for Stop/Angle valve 15mm bore, cast copper alloy screwed down, high pressure, with crutch jor butter fly handlel, screwed bosth ends for iron pipe or for unions Complete all as directed by Engineer-in-Charge.
S&F Bib tap cast copper alloy chromium plated fancy type with crutch of butterfly handle, screwed down, screwed for iron pipe of for brass ferrule of 15mm bore (ISI marked) Complete all as directed by Engineer-in-Charge.
M&L Lagging to pipes 15mmdia used in internal water supply or plumping all round with,25mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144 kg/cum conforming to IS-9842 Complete all as directed by Engineer-in-Charge.
M&L Lagging to pipes 20mm dia used in internal water supply or plumping all round with,25mm thick bonded mineral wool preformed 'SNAP ON' pipe sections of density 144 kg/cum conforming to IS-9842 Complete all as directed by Engineer-in-Charge.
S&F Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed with 20mm dia Complete all as directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement Complete all as directed by Engineer-in-Charge.
S&F PVC connection 15mm dia and 600mm long with PTMT nuts and washer Complete all as directed by Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) pipes with waste and vent pipes single socketed in any length with rubber ring joints fixed laid in trenches or in floor or to walls for weep holes Complete all as directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) pipe single socket in any length with rubber ring jointed, fixed to wall /floor etc Complete all as directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) bend or tee or radius Complete all as directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) bend or tee or radius Complete all as directed by Engineer-in-Charge.
S&F PVC gully trap square or round mouthed type (P) , size of trap 125x 110mm and jointing to drains with solvent cement in repairs Complete all as directed by Engineer-in-Charge.
S & F Waste coupling of PTMT (half or full thread ). ( Minimum weight 32 mm-45 gms / 40mm-60gms) for 32mm bore dia of discharge pipe to WHB etc Complete all as directed by Engineer-in-Charge.
S&F PVC valveless syphonic action type flushing cistern,low level white with inlet ball valve float and handle incl brackets (10 Ltr) capacity, with flush pipe etc fixed Complete all as directed by Engineer-in-Charge.
S&F Soap dish chromium plated,any type, fixed to wall with chromium plated brass screw Complete all as directed by Engineer-in-Charge.
S&F vitreous china wash basin, white, flat back, size 550x400mm ISI marked including waste chain & plug and porcelean stopper and including brackets, waste pipe, etc Complete all as directed by Engineer-in-Charge.
S&F Pillar tap 15mm bore cast copper alloy, with capstain head chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed both ends for iron pipe or for unions and fixed Complete all as directed by Engineer-in-Charge.
S & F tubular towel rail 60cm long, aluminium anodised fixed with and including CP brass screws and wooden/plastic cleats Complete all as directed by Engineer-in-Charge.
S&Fsteel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 20 mm ISI marked Complete all as directed by Engineer-in-Charge.
S&F GI steel water tubing medium grade galvanized with all fittings and fixed complete to walls, ceilings or laid on floors, bore of tube 15mm ISI marked Complete all as directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable Complete all as directed by Engineer-in-Charge.
M&L for Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid Complete all as directed by Engineer-in-Charge.
Supply and laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core ISI marked Complete all as directed by Engineer-in-Charge.
M&L Point wiring with 1.5 Sq. mm (nominal area) HR-FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) suitable size with all accessories having thickness not less than 1.8mm incl sheet steel/ CI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor multistranded cable of green colour as earth conductor connected to common earth dolly complete all as specified and directed for one light / fan point controlled by one switch 5 Amp, SP, one way, 240 Volts. Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit in not feasible. 3. Proper colour code will be used for wiring as per the electrical rule and Complete all as directed by Engineer-in-Charge.
M & L for point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor HR-FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia having thickness not less than 1.8 mm with all fittings including anodise pressed steel sunken box having thickness not less than 2mm with 3mm bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface Complete all as directed by Engineer-in-Charge. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained
S & F switch piano flush button single pole one way 5 Amp AC 240 volts, Complete all as directed by Engineer-in-Charge.
S & F switch piano flush type one way 15 amps SP 240 volts Complete all as directed by Engineer-in-Charge.
S & F socket outlet 2 in 1, 3 pin, 5 and 15 amps flush type 230 volts Complete all as directed by Engineer-in-Charge.
S & F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
M & L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals Complete all as directed by Engineer-in-Charge.
S & F LED Bulb, B22 type ,14 watt Complete all as directed by Engineer-in-Charge.
S&F 20W surface / wall mounted batten LED luminair, extruded aluminium housing with PC diffuser and ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directedories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings Complete all as directed by Engineer-in-Charge.
S&F in replacement sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast , bipin holder, connector block etc. complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core Complete all as directed by Engineer-in-Charge.
S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size Complete all as directed by Engineer-in-Charge.
M & L for providing/ cutting the round/ square hole of required size in wall finishing the distrubed surfaces as per existing finishes complete all as spd and supply and fixing MS ventilating fans Single phase, 230 volts 300 mm or complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge.
S & F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp Complete all as directed by Engineer-in-Charge.
S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 6-32 Amp Complete all as directed by Engineer-in-Charge.
M&L for sub Main Wiring with 2 run of single core, 6 Sqmm HR- FRLS PVC insulated and unsheathed, multi starndedcopper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm FRLS PVC insulated and unsheathed copper conductor cable in green colour as earth conductor connected to common earth dolly, drawn in and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8mm (ISI marked) with and including all accessories complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface including taking down of existing unserviceable surface/cocealed sub main wiring any type Complete all as directed by Engineer-in-Charge. Note: Two run of submain wire (phase and neutral), and one run of earth including PVC conduit and accessories will be measured as one run.
S & F bldg secuirty light fitting energy saving high efficiency LED street light fitting 30 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth strip of size 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, GI funnel, wire mesh and 20mm bore GI water pipe light grade and 40mm bore light grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid separately) Completed all as specified and directed by Engr-in-Charge.
M/S SUHEEL CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .