Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC BX 167 4 ISHWAR NAGAR PATHANKOT PUNJAB 145001 UDYAM PB 16 0001334 03AALFR1593C1ZE B R | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹12.4 L+₹1.3 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Being not a lowest | |
| 3 | L3₹13.2 L+₹2.1 L (19.0%)Rejected-Finance 6 GURU GOBIND SINGH NAGAR DHAKOLI DHAKOLI PATIALA PUNJAB 140602 | PATIALA | PUNJAB | 140602 | L3 | Rejected-Finance Being not a lowest | |
| 4 | L4₹14.5 L+₹3.4 L (31.0%)Rejected-Finance | L4 | Rejected-Finance Being not a lowest |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
7 Jan 2021, 6:00 pmClosed
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR, CLEANING AND DESLUDGING OF SEWAGE LINES, MANHOLES, SANITARY FITTINGS, MANHOLE COVERS ETC IN ZONE B UNDER AGE BR II OF GE (WEST) PATHANKOT
2020_MES_402529_1
GE/PKT-49/2020-21
Open Tender
Civil Works
Item Rate
335 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹34,000
Yes
19 Jan 2021
10 Dec 2020
9 Jan 2021
10 Dec 2020
7 Jan 2021
24 Dec 2020
11 Dec 2020 - 19 Dec 2020
Amount
Cleaning of chocked / blocked IWC / EWC / Nahani, floor or gully trap (Bathroom outlet / Kitchen outlet) in daily routine on working day as per complaint lodged by User's, complete all as specified and directed by Engineer-in-Charge. Note :- Safaiwala 4 nos (0900HRS to 1800HRS should be deployed for attending daily complaints.Recovery of Rs 500/- per day for absentee will be deducted for each person
Cleaning of sewage line in any depth (0.60 Mtr to 6.00 Mtr) including affected/connected manholes and desluding, dewatering of manhole of any size by mechanical sucking/pressure pump (truck mounted) including cleaning of connected sewage pipe line of size 100 / 150 / 160 / 200 / 300mm bore, laid in trenches and any length including water closet, gully trap etc. by hydraulic jet pressure machine as required at site flushing the line and manholes with water as to make the fully functional line with manhole to entire satisfaction of Engineer-in-Charge and removing sludge outside the periphery of defence land at his own arrangements where sanitary hazards donot take place as per direction / instructions of civil authority and burried in excavated pits and covering the same. Adequate water for flush out sludge to be arranged by the contractor without ay extra cost. Pipe line including manholes cleared / cleaned under this item is to be maintained by the contractor and kept fully functional by removing any type of blokage of entire period of completion of work without any extra cost and refixing manhole cover after cleaning, complete all as specified and directed by Engineer-in-Charge. Note :- Unit rate quoted by tenderer/bidder shall be include taking out sludge from line and manholes (liquid, semi-liquid, solid) excavation of borrow pits for dumping sludge, removing including loading/unloading and transportation etc.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
M&L for Brickwork with sewer bricks straight or curved on plan exc 6 m mean radius for man-holes/ septictank/ soakwell etc. in sewer works in CM 1:4 complete all as specified and directed
M&L for Rendering 15 mm thick CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Demolition of reinforced cement concrete in cover slabs,Man holes etc and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Providing factory made precast cement concrete 1:2:4, type B-1 using 20mm graded stone aggregates as in cover slabs (for main holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throatinging etc. and setting in CM (1:4) with joints to match, complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in binders, stirrups, spacers for cover slab, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft and loose soil complete all as specified and directed.
All as per Srl item No 9 here-in-before but depth exc. 1.50 m but not exc. 3m.
M&L for UPVC 160mm 4KN, 4mm solid wall thickness (SWR) pipes single socketed, in any length with rubber ring /adhesive joints, laid in trenches or in floors, complete all as specified and directed.
M&L for UPVC 200mm 4KN, 4mm solid wall thickness (SWR) pipes single socketed, in any length with rubber ring /adhesive joints, laid in trenches or in floors complete all as specified and directed.
S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with brackets complete all as specified and directed
S&F Pre cast reinforced gully trap size 600mm x600mm x 600mm) connecting to existing pipe along with reducer as required for the first manhole complete all as per specified and directed
S&F 110mm PVC (SWR) bends any radius complete all as specified and directed
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed
S&F 110 mm PVC (SWR) 'P’ trap connector for any type of closet complete all as specified and directed
Demolition and breaking up drain pipes 200mm dia (Saltglazed ware, AC ,PVC or Reinforced concrete) set in cement mortar fixed in any position complete all as directed
M&L for Concrete bed to drain pipes100mm / 110mm including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2 complete all as specified and directed
M&L for Concrete bed to drain pipes 150mm / 160mm including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2 complete all as specified and directed
M&L for Concrete bed to drain pipes 200mm including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2 complete all as specified and directed
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft /loose soil, complete all as specified and directed
Add to item No 24 here-in-before for depth every 15 cm or part thereof above average depth complete all as specified and directed
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 75mm thick Cement concrete 1:2:4 type B-2, (40mm graded aggregate) finishing concrete surface even and smooth with out using extra cement complete all as specified and directed
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern and trap), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc. white and also including fixing bolts, flushing cistern 10 ltr capalcity PVC, flush pipe and seat cover complete all as specified and directed
S&F in repairs Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor including flushing cistern 10 ltrs capacity PVC and flush pipe complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 45,225.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder immediatelly after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
M/S SALARIA BUILDERS
JP AND CO.
JANDIAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .