GE CAMPBELL BAY
GE CAMPBELL BAY ARMY LAND CAMPBELL BAY GREAT NICOBAR-744302
PREVENTING/CORRECTIVE MAINTENANCE OF COOLING APPLIANCES, EARTHING, STAND BY DIESEL GEN SETS AND RAIN WATER HARVESTING AND EXISTING EXTERNAL WATER PIPELINES AND OTHER ALLIED WORKS AT VARIOUS LOCATION AND MAINTENANCE OF STREET LIGHT POLES, STREET LIGHT
2026_MES_794390_1
8266/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CAMPBELL BAY
AS PER NIT AND TENDER
9 documents required · 9 mandatory
₹500
Yes
GE CAMPBELL BAY
₹62,000
Yes
19 Oct 2026
19 Oct 2026
13 Nov 2026
19 Oct 2026
11 Nov 2026
4 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for Servicing of Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5 TR of any make and any type cleaning of outdoor condenser coil with water pressure pump and indoor unit coil cleaning by proper bresh and checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning complete all as specified and directed. | - | Each Job | - | - |
| 2 | Description all as per Srl item No 1.00 above but, capacity 2 TR complete all as specified and directed. | 2 | Each Job | - | - |
| 3 | Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete as specified and directed. | 10 | RM | - | - |
| 4 | Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 4 x 6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete all as specified and directed. | 10 | RM | - | - |
| 5 | M&L for Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified . | 2 | Each | - | - |
| 6 | M&L for Modular AC BOX with a two pin and earth plug and socket complete with one single pole MCB including removal old unsv one complete all as specified . | 2 | Each | - | - |
| 7 | M&L for AC plug top complete all as specified and directed. | 2 | Each | - | - |
| 8 | S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incoming & outgoing MCBs and making smooth the wall surfaces complete all as specified and directed. | 1 | Each | - | - |
| 9 | Material & labour for filling up & charging of R - 22/ R-32/ R-410 refrigerant or any type of refrigerant gas suitable to the existing AC unit as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after completion of leak testing of complete system and making good by bracing complete all as specified and directed. | 20 | Kg | - | - |
| 10 | M&L for Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, as directed and testing commissioning including taking down & refixing of out door unit in same or new location complete all as specified and directed. | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_890945.xls
BOQ • 0.50 MB
8266TENDER.pdf
Tender Documents • 1.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .