Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹97.4 L
EMD Value
₹1.9 L
Closing Date
10 Mar 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,Trans. Line Maint
Executive Engineer,Trans. Line Maintt. Div-II, JKPTCL, Gladni, Jammu
Construction of 1No 33KV feeder bay and other allied works for optimum utilization of transformation capacity and Evacuation of power from augmented 3X50 MVA, 132/33KV Grid Station Miransahib
2023_PDD_205234_1
TLMD-II/J/11 of 2022-23 Dated 15-02-2023
Open Tender
Electrical Works
Turn-key
120 days
MIRANSAHIB JAMMU
AS PER NIT AND SBD
3 documents required · 3 mandatory
₹5,000
Executive Engineer,Trans. Line Maintt. Div-II, JK
₹1.9 L
11 Apr 2023
15 Feb 2023
13 Mar 2023
16 Feb 2023
10 Mar 2023
17 Feb 2023
Amount
(A)Design, manufacture, supply, packing & forwarding, transportation, delivery at site of equipments and materials.
Structures
Fabrication, galvanisation, supply including packing and forwarding, transportation charges of 132 kV Gantry structure & 33 kV structures (each type).
Galvanised Nuts & Bolts of sizes
Main Equipments
Control and Relay Panels
33KV Control and Relay Panel for 33 KV Line Bay completely wired including Substation automation supporting IEDs/numerical relays
3 pole,VCB, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (36KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 1 second).
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications), 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Power and Control cables including termination of the cables
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete as per specification.
16 core, 2.5 sq mm
2 Core, 2.5 sq mm
5 Core, 2.5 sq mm
8 Core, 2.5 sq mm
12 Core, 2.5 sq mm
2 Core, 6 sq mm
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing for 33 kV. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Cable Glands, ferrules & Lugs for all above cables etc.
ANCILLARY ITEMS
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps single 500mm2 / single 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
PG clamps suitable for twin 500mm sq ACSR shall comply in all respects with IS:5561-1970 (latest edition)
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
CABLE TRAYS/CABLE RACKS/ACCESSORIES
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc
(B) HANDLING, STORAGE, PRESERVATION, ERECTION (EXCEPT CIVIL WORKS), DEHYDRATION, TESTING & COMMISSIONING OF EQUIPMENTs AND MATERIAL
Structures
Fabrication, galvanisation, supply including packing and forwarding, transportation charges of 132 kV Gantry structure & 33 kV structures (each type) Structures with stubs Column of C1 type-1No Beam of B1 type- 1 No, column C3 type -2 Nos column C4 type -2 Nos Beam B3 type - 2Nos Beam B4 type- 4N0s Equipment structures, Circuit breaker structure - 1 No., CT structure- 3 No, Isolator structure - 4No, Surge Arrester structure - 3No. and its erection including its testing and commissioning.
Galvanised Nuts & Bolts of sizes
Main Equipments
Circuit Breakers
3 pole,VCB, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (36KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 1 second).
Isolators
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Surge Arrestors
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries
Control and Relay Panels
33KV Control and Relay Panel for Transformer Bay completely wired including Substation automation supporting IEDs/numerical relays
Current Transformers
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Power and Control cables including termination of the cables
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete as per specification.
16 core, 2.5 sq mm
2 Core, 2.5 sq mm
5 Core, 2.5 sq mm
8 Core, 2.5 sq mm
12 Core, 2.5 sq mm
2 Core, 6 sq mm
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing for 33 kV . Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Cable Glands, ferrules & Lugs for all above cables etc.
ANCILLARY ITEMS
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps single 500mm2 / single 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
PI/PG clamps suitable for twin 500mm sq ACSR shall comply in all respects with IS:5561-1970 (latest edition)
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
CABLE TRAYS/CABLE RACKS/ACCESSORIES
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc
(C) Civil Works including design, supply, excution and prepration of drawings
Foundations for Gantry and Foundation structures
Earth work in excavation by mechanical means (Hydraulic excavator) over areas ( exceedind 30 cm in depth 1.5 mtr in width as well as 10 sq.m on plan ) including disposal of excavated earth, lead upto 50 m. & , lift upto 1.50 m disposad earth to be levelled and neatly dressed. a) All kinds of soil
Providing and laying of lean pad 1:4:8 with 40mm crushed stone aggregate
Fixing of foundation bolts including alignment
Providing of angle iron (200x200x16) for stubs with cleats (Complete set)
Filling available excavated earth(excluding rock) in trenchs,plinth,sides of foundation etc. layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 15 mtr and ift upto 1.5 mtr.
Reinforcement for R.C.C. work including providing, straightning, cutting,bending, placing in position and binding all complete bars (TMT)
Providing & laying in position R.C.C (excluding the cost of centring and shuttering and reinforcement in 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size))
Centring and shuttering including strutting, proping etc and removal of the same. (for foundations and chimneys) - Form Work.
Mechanical carriage of materials from different sources upto dumping site on an average lead of 20 kms:-
(a) Stubs, templates, reinforcement.
(b) Foundation bolts
(c) Sand
(d) Bajri (40mm/20 mm)
(e) Cement
Mannual Carriage of materials from dumping site upto actual site of work (average lead 100 mtr.) :-
(a) Stubs, templates, reinforcement.
(b) Foundation bolts
(C) Sand
(d) Bajri (40 mm/20 mm)
(e) Cement
Clearance of site foundation by removal of grass vegetation and demarcation and alignment,pit marking of complete coulomn foundation.
Mech carriage of disposable earth av lead 20 km
Manual carriage of disposable soil upto loading site av distance 100 mt
Construction of Earth mat
Earth work Excavation
Manual Carriage of disposable Earth beyond 100 Mts
Mechanical Transport of Disposable Earth 3 Km. Lead
Laying of M.S.flat
Surface cleaning, jointing by welding etc
Driving of Spikes
Providing of Steel flat 65x8 100 RM & Round iron for Spikes
Construction of Cable Trenches and duct covers
Earthwork in excavation by manual means in trenchs for foundations , drains , pipes , cables etc ( exceeding 1.5 m in width ) and for shafts , wells ,cesspits and the like not exceeding 10 sqm on plan , depth upto 1m from cutting edge ,disposed earth to be levelled and neatly dressed in . All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level in 1:4:8 (1 cement:4 coarse sand:8 graded stone aggregate 40mm nominal size)
Providing & Laying of reinforced cement concrete in M-15 grade incl. curing complete but excl. centring & shuttering (Bed and walls)
Reinforcement for RCC works including straightening, cutting , bending, placing in position and binding all complete. Thermo-mechanically treated bars (12 mm bars)
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Carriage of materials by mechanical transport
Sand with a lead of avg 30km
Crusher Aggregate with a lead of avg 10 km
Cement
Dismentling of existing Mesh Fencing along with Foundations
Dismentling of retaining wall
Manual carriage of the dismantled material to a suitable place
Mechanical transport carriage of the dismentled matrial
Dismentling of Mesh fencing
Carriage of Mesh fencing along with angle iron posts to some suitable place
CONSTRUCTION OF MESH FENCING ALONG WITH FOUNDATION
Earth work in Excuation=50*(0.6+0.68)/2*0.45
Disposal of earth manually upto stacking site
Mechanical transport carriage of the earth from MIRAN SAHIB grid station to disposable site average lead 30 KM
Lean pad 1:4:8(50*0.15*0.75)
RRM (1:6 mix)
Laying of DPC 1:2:4
MT carriage of cement upto 35 KM
Manual carriage of cement from store to working site
MT carriage of sand upto 35 KM
Manual carriage of sand from unloading site to working site
MT carriage of Bajri upto 35 KM
Manual carriage of Bajri from unloading site to working site
MT carriage of stone upto 35 KM
Manual carriage of stone from store to working site
centering & shuttering= walls of any thick ness 2no.50*1.55
Angle(60*60*6) =11*1mtr=11 runing [email protected]/running meter
Providing and fixing of concentina wire
G.I mesh wire=50.50*0.60sqm
Cutting of trees, wild vegetation near the fence
Zeal Power
AJAY CONSTRUCTION
HITECH ERECTORS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
PDF • 0.22 MB
tech_eval.pdf
PDF • 0.56 MB
fin_bid_open.pdf
PDF • 0.56 MB
boq_comp_chart.xlsx
xlsx • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .