Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1,750
Closing Date
27 Apr 2020, 12:00 pmClosed
The Superintending Engineer/KEDC/KPM
The Superintending Engineer Kanchipuram Elecy. Distn. Circle No1 Vellore Road, Olimohamedpet, Annamaaligai, Kanchipuram631502
ImprovementEssential Repair Works and Face lifting to the proposed stationary store building at kanchipuram central Stores premises.
2020_EB_161165_1
SE/KEDC/KPM/OT16/20192020 Civil
Open Tender
Civil Works
Works
60 days
Kanchipuram
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1,750
Yes
17 Jul 2023
16 Mar 2020
28 Apr 2020
16 Mar 2020
27 Apr 2020
17 Mar 2020
17 Mar 2020 - 20 Mar 2020
Amount
Supplying and fixing Aluminium partition with 9 mm thick both side pre laminated boards / 5 mm thick glass using Aluminium box section 63 x 38.4 x 2 mm at 955 mm c/c for verticals and horizontals including cost of all materials , lead, lift, labour, etc., complete as directed by the engineers at site.
Supplying and fixing Aluminium Door with 9 mm thick both side pre laminated boards / 5 mm thick glass using Aluminium box section 45 x 45 x 2 mm for top, middle and sides 100 x 45 x 2 mm for bottom including approved quality Mortise lock, aluminium handles at front and back, aluminium hinges, door stopper, etc., including cost of all materials, lead, lift, labour, etc., complete as directed by the engineers at site.
Supplying and fixing the 20 mm Thick approved good quality thermo Cole sheets false ceiling over aluminum L angle25 x 25 x 1.50 mm and aluminum T angle 38 x 38 x 1.50 mm at 1000 x 500 mm center to center spacing at accommodate the thermo Cole sheets, including fixing the aluminum grid of size 1000 x 500 mm to the existing ceiling / walls / beams with G.I.wire / M.S.Rods with standard specification including cost of all materials, lead , lift, labour, etc. complete as directed by the Engineers at site.
Supplying and fixing the 16 Amps DP switch with metal clad (side handle) with rewirable fuse units of approved quality and make on suitable angle iron frame work MS cble entry boxes with PWD earthing, fixing on the wall with all connection properly including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site.
Supplying and Providing open wiring to the light points, tube light points, bulk head points with approved quality 2 x 2.5 sq.mm PVC unsheathed SC copper cable of 650v grade along with 1.0 sq.mm PVC unsheathed SC copper cable for earthing inside the suitable PVC rigid pipe with necessary bends, tees, junction box, ceiling house, houlders, etc, 5 Amps. single pole switch of approved quality fixing in a 3 mm thick hylum sheet cover with T.W. switch box of suitable size, etc, including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site and jointing properly and making required holes in masonry or concrete and restoring the dismantled surface to original condition complete in all aspects.
Supplying and Providing open wiring to the 5 Amps. plug points,with approved quality 2 x 2.50 sq.mm PVC unsheathed SC copper cable of 650v grade along with 1.0 sq.mm PVC unsheathed SC copper cable for earthing inside the suitable PVC rigid pipe with necessary bends, tees, junction box, etc, 5 Amps. single pole switch and 3/5 pin plug of approved quality fixing in a 3 mm thick hylum sheet cover with T.W. switch box of suitable size, etc, including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site and jointing properly and making required holes in masonry or concrete and restoring the dismantled surface to original condition complete in all aspects.
Supplying and fixing of 18 / 20 Watt Special Type LED Light fitting of approved quality fixing in the existing wall / False Ceiling with all connection properly including cost of all materials, lead, lift, labour, testing, etc., complete as directed by the Engineer at site.
Supplying and fixing and testing of A.C. Ceiling fan complete 1200mm (48") sweep with Down rod, regulator of approved quality fixing in the existing pipe / ceiling with all connection properly including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site.
Colour washing / White washing the interior and exterior wall surface using approved good quality Acrylic Emulsion paint two coats over a coat of wall primer. Before painting the wall surface should be properly cleaned and the wall surface should be applied the approved quality wall putty neatly,[ patch work only ] etc, including cost of all materials, lead, lift, labour, scaffolding charge, etc., complete as directed by the Engineer at site.
Painting the iron works with Two coats of approved quality Enamel paint over a coat of red oxide primer including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site.
Painting the old window with one coat of wood primer and two coats of approved quality Enamel paint before painting the wooden surface are fully scrubing the old painting and smoothing the surface by applying the putty , including cost of all materials, lead, lift, labour, etc., complete as directed by the Engineer at site.
SGST PERCENTAGE IN FIGURES
CGST PERCENTAGE IN FIGURES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .