Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹2.5 L
Closing Date
25 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GSU
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. Substantially Completed Work means an ongoing work in which payment equal to or more than 90% of the present contract value (excluding the payment made for adjustment of Price variation (PVC), if any) has been made to the contractor in that ongoing contract and no proceedings of termination of contract on Contractor's default has been initiated. The credential certificate in this regard should have been issued not prior to 60 days of date of invitation of present tender.
Definition of similar work: "Satisfactory execution of any electrical work related to HT/LT installation.
43 conditions · 10 needing a document upload
Please submit bank details of the firm / individual/ JV / partnership etc. i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, PAN Number, Aadhar number and other necessary & relevant documents.
Please furnish documents in support of your claim to fulfill the eligibility criteria as mentioned in the tender documents. Each page of the copy of documents / certificates in support of credentials, submitted by the you, shall be self attested / digitally signed by the you or authorized representative of the your firm. Only those documents which are declared explicitly by you as "documents supporting the claim of qualifying the laid down eligibility criteria",will be considered for evaluating the offer or otherwise available in the offer
Please furnish statement of deviations from tender conditions, if any.
Requisite documents proving technical eligibility criteria and financial eligibility criteria has been uploaded along with those required as per explanation given in clause 10 of IRGCC-2022 (Works Matter)
All requisite valid documents regarding constitution of business of the bidding firm should be submitted along with the tender as per clause 14 of IRGCC 2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate. Reference: para 15 of IRGCC-2022 (Works matter),otherwise their offer will be considered incomplete and shall not be considered.
Partnership firms, if bidding for the instant tender, should submit all valid requisite documents and fulfill the stipulations as per clause 18 of IRGCC-2022 (Works Matter),otherwise their offer will be considered incomplete and shall not be considered.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are advised to visit the site of work to ascertain all aspects of the site conditions viz accessibility, availability of approach road, nature of the soil, availability of material, availability of labour etc. that may be encounteredin course of execution of work.
Tenderer should see the website for the corrigendum/addendum to the NIT/tender document, if any that may be uploaded prior to tender opening(inclusive) as there will not be any separate communication for that.
The tenderer for carrying any construction work in Uttar Pradesh mustgetthemselves registered from the registering Officer under Section - 7 oftheBuilding and Other Construction Workers Act, 1996 and rules made theretoby the Uttar Pradesh Govt. and submit certificate of Registration(LabourDepartment). For enactment of this Act, the tenderer shall be requiredto paycess @ 1% of cost of construction work to be deducted from each bill
The contractor(s) shall observe all the formalities, perform all the actsandabide by all the provisions contained in the Contract Labour Act-1970andContract Labour Central Rules, 1971 which in addition to otherstipulationsprovides that the contractor(s) shall obtain license(s) from appropriatelicensing officer of thearea before commencement of the work and shall produce a copy thereof along with the original to the Railway office, which will be returned to the contractorafter verification
If any complaint is received against the contractor regarding violationofcontract laws, (exposing Principal Employer to the risk of legalproceedingsunder labour laws), the guilty contractor will be black listed andtheir contract shall be terminated following the due procedure, apart frominitiating criminal proceedings against him with the help of Labour departmentofficials.(Authority: RB letter no.2008/E (LI)/AT/CNR/3, dated 24.01.2018).
The tenderer has to submit necessary documents in compliance of clause 10to 18 (Part-I) of IRGCC 2022 (Works matter) mandatorily, otherwise offer willbe considered as Incomplete Offer and accordingly shall not be considered
It is the responsibility of the tenderer to see corrigendum, if any, totender notice up to the date of tender opening. IRGCC 2022 (works matter) isforreference only. Any correction issued by competent authority up to dateofopening will be applicable. Tenderer should quote accordingly
Railways reserves the right to accept or reject any or all the tenders and toaward the work in whole or in part without assigning the reason for any such action.
It is to be noted that tenderer digital signature on the E-Tender form will be considered as confirmation that tenderer have read and accepted all the conditions laid down in the documents as well as related specification of items, schedule & quantity of items in the tender, consisting of techno commercial offer form (including special conditions attached to ETender) and Financial offer form, unless specific deviation is quoted in the techno- commercial offer form.
The quantities shown in the attached Schedule are given as a guide andareapproximate only and are as a guide to give the tenderer(s) an ideaofquantum of work involved. Quantities are subject to variation according totheneeds of the Railway. The Railway does not guarantee work under eachitemof the Schedule. The Railway reserves the right to increase/ decreaseand/ordelete or include any of the quantities given above and no extra rate will be allowed on this account.
In case of any information submitted by tenderer is found to be false forgedorincorrect at any time during process for evaluation of tenders, it shall leadtoforfeiture of the tender Earnest Money Deposit besides banning of business for a period of upto five years. In case of any information submitted by tenderer is found to be false forged or incorrect after the award of contract,the contract shall be terminated. Bid Security, Performance Guarantee andSecurity Deposit available with the railway shall be for feited. In addition, otherdues of the contractor, if any, under this contract shall beforfeited and agency shall be banned for doing business for a period of up to five years.
Opening of e-tender online:- The e-tenders will be opened online using the IREPS portal. No representative is required to be present for opening of tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders in the website after the opening of the tender.
In case the date of closing mentioned in the Notice Inviting Tender is declared a holiday/bandh/strike etc. on any account, the date of closing tender online will not be changed as the application in the website of IREPS does not permit submission of any offer after closing date and time of the tender. However, opening of tenders online will be on any convenient day after the closing date/time of tenders.
All the bidders / tenderers should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law ( Ref - Railway Board letter No.2008/RS(G)/777/1 Dated - 29/5/2017 )
The Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids. iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to Dy.CEE/GSU/PRYJ, DRM office Nawab Yusuf Road, Prayagraj- 211001. viii. If the envelope is not sealed and marked as instructed above, the Railway assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
"Electrical work in connection with "Advance Trip Maintenance center at Electric Trip Shed PRYJ & Electrical work in connection with "Advance Trip Maintenance Centre at Electric Trip Shed at CNB W/L & GMC area"in Prayagraj division".
GSU-EL-WC-70-2026~NCR
GSU-EL-WC-70-2026
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹2.5 L
25 Feb 2026
3 Feb 2026
11 Feb 2026
71 items across 1 schedule · ₹1,94,86,508 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light/fan/exhaust fan/call bell points with 1.5 sqmm (22/.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI mark, MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire along with the pipe duly clamped as required and as per relevant technical specification Sr.DEE/G/ALD/IE/94/104/Rev and additional specification .a) Medium Point. | Numbers | 1800.00 | 222.07 | 3,99,726 |
| 2 | Wiring for 3/5 pin, 5 Amp. Plug point with 1.5 sqmm (22/.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable including providing and fixing 3/5 pin 5 Amps. Socket out let with switch on same board and earthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire etc. as required and as per relevant technical specification. | Numbers | 1000.00 | 59.78 | 59,780 |
| 3 | Wiring for 3/5 pin 5/15 amps plug points with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked in recessed PVC pipe of ISI marked and MS switch box having wall thickness 16 SWG with 3 mm thick phenolic laminated sheet cover including providing and fixing 3/5 pin 5/15 Amps socket outlets and 5/15 Amps piano type switch and earthing the 3rd pin with 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) Copper earth wire along with pipe duly clamped as required and as per relevant technical specification.(5pin 15Amp). | Numbers | 800.00 | 368.21 | 2,94,568 |
| 4 | Wiring for circuit with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification.( a ) 2 x 2.5 sq mm. | Metre | 1600.00 | 68.63 | 1,09,808 |
| 5 | Wiring for circuit with 2.5 sqmm (36/0.3mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification. (b) 4 x 2.5 sq mm. | Metre | 1600.00 | 84.16 | 1,34,656 |
| 6 | Wiring for submain with 4 sqmm (56/0.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor) copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification.(a) 2 x 4 sq mm. | Metre | 1600.00 | 65.79 | 1,05,264 |
| 7 | Wiring for submain with 4 sqmm (56/0.3 mm) PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG/(1.5sqmm PVC insulated single core unsheathed stranded Copper conductor)copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification.(b) 4 x 4 sq mm. | Metre | 1600.00 | 105.11 | 1,68,176 |
| 8 | Termination of LT XLPE cables of various sizes (One Job means all 4 cores of cables). | Numbers | 40.00 | 132.89 | 5,315.6 |
| 9 | Collecting, Transporting from SSE/GSU/store to site, laying, testing, and commissioning of above LT cable . Laying direct in ground (Including excavation, sand cushioning, protection brick covering and refilling the trench etc.), direct in RCC/Metal pipes in rod/track crossings and on surface/required in wall/in concrete floor by cutting recessed and finished originally as required as per relevant technical specifications. | Metre | 15000.00 | 72.61 | 10,89,150 |
| 10 | Drilling of bituminous road/track and laying chargesof cable in road crossing for laying 110 mm diaHDPE pipe through it. | Metre | 5000.00 | 312.23 | 15,61,150 |
| 11 | Supply and laying of HDPE Pipes (Upto PN 8.0Pressure Rating Material Grade: PE 63, PressureRating: PN 8.0, Nominal Dia(mm): 110) as perrelevant IS suitable for HT/LT XLPE cable & asrequired and as per relevant technical specification.Supply and laying of HDPE Pipes (Upto PN 8.0Pressure Rating Material Grade: PE 63, PressureRating: PN 8.0, Nominal Dia(mm): 110) as perrelevant IS suitable for HT/LT XLPE cable & asrequired and as per relevant technical specification. | Metre | 5000.00 | 281 | 14,05,000 |
| 12 | Supply and laying of B class, 50 mm dia, GI pipe of for cable riser/road crossing as required and as per relevant technical specification. | Metre | 100.00 | 137.9 | 13,790 |
| 13 | Supply and burying of earth electrode of 40mm dia 'B' class GI pipe of 3.0 Mtrs long having 12 mm dia holes spaced 75 mm apart drilled upto 2 mtrs length from the bottom including 340 mm wide pit is to be dug upto the depth of not less then 3750mm. The earth electrod lowered in the pit thereafter refilling of pit is to be done with 30mm alternate layer of salt and charcoal upto 2.5 Mtrs. Pit is to be made of not less than 40 x 40 x 30 Cms from inside & precast RCC cover of 40mm thick with lifting arrangement shall confirm to CEE/NR specification No. NR/Elect/Wiring/1-84 and Drg. No. Sr. DEE/G/ALD 10/94. GI pipe shall be of TATA/QST/JINDAL make. | Numbers | 10.00 | 928.97 | 9,289.7 |
| 14 | Supply, fixing, testing, connecting and commissioning of feeder pillar with 01 no. 250A 04 pole MCCB for incoming & 25 nos s.p. 63A MCB for outgoing as per relevant specification. | Numbers | 20.00 | 19,584.87 | 3,91,697.4 |
| 15 | Supply, erection, testing and commissioning of approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification.DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's of approved make.(1) 4-No SP MCB's of 6 Amps as required . | Numbers | 60.00 | 911.91 | 54,714.6 |
| 16 | Supply, erection, testing and commissioning of approved make standard size of following Distribution board recessed in wall having earth terminal block and neutral terminal block to enable termination of conductors incoming as well as outgoing individually by screwed connections and without twisting complete in all respect as per relevant technical specification of DP distribution board of standard size confirming to technical specification No. Sr.DEE/G/ALD/94/104 comprising of one No. 2 pole 32/40 Amps MCB's & 8-No SP MCB's of 6/10 Amps as required. | Numbers | 80.00 | 1,919.94 | 1,53,595.2 |
| 17 | Supply, replacement, fixing, testing, connecting and commissioning of 72 Watt or above LED street lights fittings.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute lights,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.Type LED:- High power LED,SMD(Surface Mounting device)/COB(Clip on board).1.Input operating voltage :-105-295 V AC.2:- Normal Voltage-220V AC,3.Driver type: constant current driver with short circuit protection. 4.LED life:- >50000 burning hours.5.Depreciation:- 30% max.after 50000 burning hours.6.Control of distribution:-Full cut off. 7.Surge protection:4KV.8.Drive component :Industrial grade only.9.Efficiency of driver electronic: > 85%.10.Beam angle:>=140 degree along with road and >=80 degree across the road.11.Colour temperature:5000- 6500K.12.Colour rendering index(CRI):>=75.13.Ingress protection :IP- 66.14.Lumen output: >120 lumens/watt.15.Power factor:->0.95. 16.Total harmonics distortion(THD):-<15%.17.Lamp cover :Toughened glass or UV stabilised poly carbonate.18.Finishing:Power coated /Anodized.19.Secondry optics:poly carbonate reflector/ poly carbonates lens.20.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.21.Mounting:Suitable for existing pole/Truss/Lantern mounted.22.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminare used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.23.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted with new suitable bend/elbow with clamp and proper nut and bolt and connection with twisted twin flexible cord of minimum size 16/1 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period. | Numbers | 100.00 | 2,451.56 | 2,45,156 |
| 18 | Supply, replacement, fixing, testing, connecting and commissioning of energy efficient luminaries complete with all accessories of capacity 20 watt, 4 feet length, T8 LED lamps with suitable current control driver circuit ,suitable for surface/recessed mounting.LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/Jaquar/ PHILIPS/LUMILEDS /LEDNIUM. (2):- LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.1.Input operating voltage :-105-295 V AC.2:-Normal Voltage-220V AC.3.Driver type: constant current driver with short circuit protection(For tube light).4.Control of distribution:-Full cut off.5.Drive component :Industrial grade only .6.Efficiency of driver electronic: > 85% (For tube light).7.Colour temperature:5000-6500K(For tube light).8.Colour rendering index(CRI):>75(For tube light).9.Ingress protection :IP-20.10.Lumen output: >100 lumens/[email protected] drive current(For tube light).11.Power factor:->0.90(For tube light). 12.Total harmonics distortion(THD):- <20%(For tube light).13.Lamp cover :Acrylic cover which does not result in loss of lumens.14.Finishing:Power coated /Anodized.15.Secondry optics:poly carbonate reflector/ poly carbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitable for surface mounting/recessed mounting.18.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminaire used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period.....1x20watt. | Numbers | 400.00 | 356.17 | 1,42,468 |
| 19 | Supply, fixing, testing, connecting and commissioning of 24/36 watt 2x2 LED lights fittings, recess LED Fitting 24/36 watt ,suitable for surface/recessed mounting. LED Luminaries:-(1) A complete LED lighting unit consisting of a light source and driver together with parts of distribute light,to position and protect the light source,and to connect the light source to a branch circuit.The light source itself may be an LED array and LED module, or an LED lamp.(2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):- NICHIA/CREE/OSRAM/SEOUL/ PHILIPS/LUMILEDS/LEDNIUM. (2):-LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.1.Input operating voltage :-105-295 V AC.2:-Normal Voltage-220V AC.3.Driver type: constant current driver with short circuit protection. 4.Control of distribution:-Full cut off. 5. Lumens-3600/5400 .6.Efficiency of driver electronic: > 85% .7.Colour temperature:4000K.8.Colour rendering index(CRI):>75. 9.Ingress protection :IP- 20.10.Lumen output: >150 lumens/[email protected] drive current. 11.Power factor:->0.97. 12.Total harmonics distortion(THD):-<20%. 13.Lamp cover :Acrylic cover which does not result in loss of lumens. 14.Finishing:Power coated /Anodized.15.Secondry optics:poly carbonate reflector/ poly carbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitable for surface mounting/recessed mounting.18.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminaire used) test certificate from National/International accredited Laboratory and OEM certificate for compliance of BIS/IEC.19.Warranty:Firm to submit warranty certificate for five year along with the supply.All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materials parameters must remain unchanged during entire warranty period. | Numbers | 40.00 | 2,054.84 | 82,193.6 |
| 20 | Supply, fixing, testing, connecting and commissioning of storage type water cooler similar to Model SDLX 100, Cooling Capacity-170 litre per hour, 380 litre Storage with foundation/platform & cage. | Numbers | 2.00 | 69,230.98 | 1,38,461.96 |
| 21 | Supply, fixing & commissioning of LT Heat Shrinkable Straight through jointing Kit for 3.5/4 Core 50-95 Sqmm LT XLPE Cable. | Numbers | 20.00 | 1,502.49 | 30,049.8 |
| 22 | Supply, fixing & commissioning of LT Heat Shrinkable Straight through jointing Kit for 3.5/4 Core 120-185 Sqmm LT XLPE Cable. | Numbers | 20.00 | 2,064.52 | 41,290.4 |
| 23 | Supply, fixing, connecting and commissioning of Push Button-Industrial type Plug & socket SPN distribution board with 02 pole & earth metal Plug & socket complete with 32A S.P. MCB. | Numbers | 30.00 | 894.73 | 26,841.9 |
| 24 | Supply, erection, testing, connecting&commissioning of 20 meter high mast systemcomplete with all accessories 16 nos. luminaries of200W LED each Light, including making offoundation as per recommendation of manufacturesalong with required materials for making offoundation and with feeder pillar including all accessories. 20 M high mast with its accessoriesMast shaft shall be hot dip galvanized (Singledip)comprising of polygonal pole and welded baseplate hot dip galvanized head frame with clamps,nuts &bolts for fixing sixteen luminaries and CG boxetc.(01 Job) A rising & lowering mechanism withwinch Lenten carriage head frame, SS wire, Ropecable &power tools with 1.5 HP motor. (1Job).Supply, erection, testing, connecting andcommissioning of16 nos. luminaries of 200W LEDincluding all accessories. (01Job). Supply of M30foundation bolts of size- 850mm manufactured fromspecial steel C/W nuts, washers anchor plates &template for above mast including earthingarrangement with electrode of 40 mm dia "B" classGI pipe of 3.0 mtrs long as per Drg. No. SrDEE/G/ALD 10/94. (01Job).Construction of suitableshallow foundation withM20 grade concrete for 20Mhigh mast considering the SBC as 10/T sq mtr at 2mtr depth with all materials & labour (01 Job).Supply of twin domeaviation observation light with 2Nos LED array lamp. (01 set) Supply & installationof separate control panel in front of feeder pillarhousing suitable control circuit with timer & AVR forthe operation of the mast. It shall also consist ofsuitable control for the power tool motors withsuitable foundation. Confirming to IS:2062,IS:875Part-3 & IS:4759. make- Bajaj,Crompton Greaves or similar make approved by Railway. | Numbers | 6.00 | 8,80,517.37 | 52,83,104.22 |
| 25 | Supply, fixing, connecting and commissioning of 5 KVA Single Phase, Sine wave Digital Voltage Stabilizer as per IS:8448 or latest amendment up to date, input voltage 160-260 Volt, output voltage 230 +10% Volt with time delay relay.Make-Blue star or similar. | Numbers | 30.00 | 8,106.05 | 2,43,181.5 |
| 26 | Design,Supply, erection, testing and commissioning of LT Switch gear panel board of 2mm thick dia pressed CRC steel sheet . Panel shall be treated for anti corrosion treatment and finished with smoke gray paint as per technical specification No. Sr DEE/G/ALD/ Panel-94/113 comprising with.........Supply of Incoming ACB 630A,04 Pole draw-out 50 Hz.Coforming IS:13947-2 of make. | Numbers | 2.00 | 1,26,187.91 | 2,52,375.82 |
| 27 | Supply, fixing, testing, connecting and commissioning of of Bus Coupler ACB 630 A,04 Pole draw out,50Hz,Conforming IS:13947-3 Make- ABB/L &T/Crompton Greaves | Numbers | 2.00 | 1,26,187.91 | 2,52,375.82 |
| 28 | Supply, fixing, testing, connecting and commissioning of ACB 630 A, 415 Volt, 3 phase, 4 pole Manually draw out microproceeor basd type conforming to IS: 13947-2, IEC 60947-2 latest specification. | Numbers | 2.00 | 1,33,264.42 | 2,66,528.84 |
| 29 | Supply, fixing, testing, connecting andcommissioning of MCCB of 250 A, 36 kA Standardbreaking capacity, 415 volt, 3 Phase 4 Pole currentrating 250 Amp. | Numbers | 16.00 | 11,967.11 | 1,91,473.76 |
| 30 | Supply, fixing, testing, connecting andcommissioning of MCCB of 125A, 36 kA Standard breaking capacity, 415 volt, 3 Phase 4 Pole currentrating 125 Amp. | Numbers | 16.00 | 7,864.43 | 1,25,830.88 |
| 31 | Supply, fixing, testing, connecting andcommissioning of Indicator lamps with suitable holder | Numbers | 114.00 | 97.3 | 11,092.2 |
| 32 | Supply, fixing, testing, connecting andcommissioning of Outgoing/Feeder Panel MountedMulti-function meter with Accuracy Class 1 as perIEC 62053-21 or Class 0.5, 0.5S as per IEC 62053-22.LED meter Cl 1 with RS485: Meter should havefollowing features built-in LED • Flush mounting 96x 96 mm • True RMS measurement • Passwordprotection provision for security • Site selectable for3 Phase 4 wire, 3 Phase 3 wire, 1 Phase, CTSecondary 1A/5A, Universal Auxiliary Supply 80-300VAC/DC, Input Voltage Measurement 50-500 VAC, •64 samples/ cycle The Meter should be able toread/display following parameters InstantaneousParameters (V1, V2, V3, V12, V23, V31, Avg (VLN,VLL), A1, A2, A3, Aavg, F, PF-1, PF-2, PF-3, PF(Avg) W1, W2, W3, W (total) VA1, VA2, VA3, VA(total) Cumulative Parameters (Import Wh, ImportVah, Import load hours, Reset (old) Cumulativeparameters (Import Wh, Import load hours,Communication (RS485 Modus RTU).complete withall accessories. | Numbers | 40.00 | 2,930.95 | 1,17,238 |
| 33 | Fabrication works and insulated Aluminum bus bars of 1200A capacity for phases & 1200A capacity for neutral Bus bar shall be suitably insulated with heat shrinkable sleeves/ epoxy coating/insulating tap to withstand the test voltage of 2.5 KV Copper strip for connection outgoing as well as incoming with suitable size be provided. | Numbers | 2.00 | 62,134.27 | 1,24,268.54 |
| 34 | Supply and erection of 6 Mtr.Galvanised (as per BS EN ISO 1461) octagonal pole with base plate 220x220x12mm, top 70mm and bottom 130 mm of 3mm thick sheet suitable for maximum wind speed utp 160 Km/Hr. including foundation bolts and foundation with M 20 grade RCC and FE 415 grade reinforcement (450x450x800 Cm deep ) (foundaton should be as per design approved by pole monufacturer) GI base plate G.I. anchor plate etc.as required including supplying and fxing of 1 Mtr.long double arm hot depped galvanised bracket suitable for street light fittings and supplying and drawing of 3x2.5Sq.mm FRLS copper conductor single core cable from junction box with two Nos 6/10AMP MCB to luminaire complete including termination with copper lugs as required. | Numbers | 50.00 | 14,572.22 | 7,28,611 |
| 35 | Supply, replacement, fixing, testing, connecting and commissioning of Synthetic Honeycomb pads Floor Standing with Trolley mounted with castor wheels mosquito breeding proof Desert Cooler (Baja X Force 135) Bajaj Plastic Body stand. | Numbers | 4.00 | 26,000 | 1,04,000 |
| 36 | Supply, replacement, fixing, testing, connecting and commissioning of energy efficient luminaries complete with all accessories of LED luminaire of 18 watt 110 V DC Pit light/cat walk light complete with pressure dia cast housing built in external heat shrink with suitable cover to uniform light description internal high efficiency LED driver with in built SMPS power supply structure within connection with two core PVC insulated exible copper cable. Make-Bajaj ,Philips, Wipro ,Havells, Crampton ,Aster, Pyrotect or Equivalent. | Numbers | 100.00 | 1,467.77 | 1,46,777 |
| 37 | Wiring for submain with 6 sqmm PVC insulated single core unsheathed stranded Copper conductor ISI marked cable in recessed PVC pipe of ISI marked and running of 16 SWG copper earth wire duly clamped with pipe and providing multiway connector on MS switch box for neutral looping etc. as required and as per relevant technical specification.( a ) 2 x 6 sq mm | Metre | 2400.00 | 78.95 | 1,89,480 |
| 38 | Supply and commissioning of C5112.17 12M PLATE with ISI Mark. | Numbers | 200.00 | 729.07 | 1,45,814 |
| 39 | Supply and commissioning of C5108.17 8M PLATE with ISI Mark. | Numbers | 160.00 | 514.76 | 82,361.6 |
| 40 | Supply and commissioning C5106.17 6M PLATE. with ISI Mark. | Numbers | 300.00 | 467.51 | 1,40,253 |
| 41 | Supply and commissioning of C5102.03 2M PLATE with ISI Mark. | Numbers | 300.00 | 222.36 | 66,708 |
| 42 | Supply and commissioning of C5103.03 3M PLATE with ISI Mark. | Numbers | 200.00 | 243.32 | 48,664 |
| 43 | Supply and commissioning of M.K. GDW 2606S 6- BM BOX with ISI Mark | Numbers | 300.00 | 176.8 | 53,040 |
| 44 | Supply and commissioning of M.K.GDW26012 1- 2MBOX. with ISI Mark. | Numbers | 300.00 | 76.55 | 22,965 |
| 45 | Supply and commissioning of M.K. GDW 26003 3MBOX. with ISI Mark. | Numbers | 200.00 | 91.13 | 18,226 |
| 46 | Supply and commissioning of PIPE 25 MM . with ISI Mark. | Numbers | 4000.00 | 72.91 | 2,91,640 |
| 47 | Supply and commissioning of 12 MODULE BOARD with ISI Mark. | Numbers | 200.00 | 140.34 | 28,068 |
| 48 | Supply and commissioning of 8 MODULE BOARD. with ISI Mark. with ISI Mark. | Numbers | 160.00 | 94.78 | 15,164.8 |
| 49 | Supply and commissioning of 6 MODULE BOARD with ISI Mark. | Numbers | 300.00 | 86.58 | 25,974 |
| 50 | Supply and commissioning of 3 MODULE BOARD with ISI Mark. | Numbers | 200.00 | 72.91 | 14,582 |
| 51 | Supply and commissioning of 2 MODULE BOARD. with ISI Mark. | Numbers | 300.00 | 54.68 | 16,404 |
| 52 | Supply and commissioning of JUNCTION (1Number= 1 Packet). with ISI Mark. | Numbers | 700.00 | 173.15 | 1,21,205 |
| 53 | Supply and commissioning of BEND (1 Number= 1Packet). with ISI Mark. | Numbers | 600.00 | 227.83 | 1,36,698 |
| 54 | Supply and commissioning of socket 6-10A 3+2 Pin(Round & flat) shuttered -2 module. with ISI Mark. | Numbers | 400.00 | 326.94 | 1,30,776 |
| 55 | Supply and commissioning of Switch 6-10A one way module with ISI Mark. | Numbers | 400.00 | 188.27 | 75,308 |
| 56 | Supply and commissioning of socket 16A and 6A 3pin shuttered -2 module with ISI Mark. | Numbers | 200.00 | 397.8 | 79,560 |
| 57 | Supply and commissioning of Switch 16A one - way-1 module with ISI Mark. | Numbers | 200.00 | 271.27 | 54,254 |
| 58 | Supply and commissioning of 6-12 Module Box with ISI Mark. | Numbers | 1100.00 | 196.36 | 2,15,996 |
| 59 | Supply, installation, testing and commissioning ofELCB/RCCB 40 AMP Double Pole, Type A ratedvoltage-240 V, 50 Hz residual operating current-0.1A, residual making and breaking capacity-500 A,rated conditional short circuit current and ratedconditional residual short circuit current-6000 A,rated impulse withstand voltage-4 kV, without timedelay. | Numbers | 30.00 | 2,038.95 | 61,168.5 |
| 60 | Design, fabrication, supply and fixing of GI perforated horizontal cable- tray with all connected accessories viz- bend, tree, cross, reducer, 45 ° horizontal bend, coupler plates etc.including painting besides clamping, shifting of existing cables into the trenches along with tagging and labling of shifted cables with numbering sleeves fot easy identification. size 300 mm width , 100 mm depth, 2 mm thickness. | Metre | 500.00 | 1,145.09 | 5,72,545 |
| 61 | Supply, fixing, testing, connecting and commissioning of 1200mm sweep BEE 5 Star rated ceiling fan with Brushless Direct current (BLDC) Motor,Class of Insulation B,03 no Blade,30 Centimeter long down Rod 02 No Canopiess,Shackle kit,Safety Rope,Copper winding power factor not less than 0.9 ,Service value (CM/M/W)Minimum 6.00 Air delivery minimum 210 Cum/Min,350 RPM(Tolerance as per IS:374-2019) THD Less than 10 % remote or Electronic regulator unit for speed control & all remaining accessories including Safety fin,Nut Bolts,Washers,temperature rise=75 degree C Maximum,Insulation Resistance more than 2 Mega ohm suitable for 230 volts,50 HZ,Single phase,AC Supply,Earthing Etc,Complete as required. | Numbers | 100.00 | 2,509.68 | 2,50,968 |
| 62 | Supply, Erection testing, connecting and commissioning of maintenance free Earthing RDSO spec no.RDSO/SPN/197/2008 or Latest consisting of. Earth electrode of copper bonded high tensile low carbon steel rods, specially designed for electrical grounding as per RDSO Spec. No RDSO/SPN/197/2008 or latest. RDSO approved earth enhancing compound in 10 Kg pack - 05 No. Copper tape of 25mm x 6mm x 300mm with 99.9% purity - 2 Nos and another of 25mm x 6mm x 150mm to terminate on earth electrode Supply of insulated connecting cable as per RDSO Spec No RDSO/SPN/197/2008 or latest to connect equipment bus bar 10 meter each earth Installation of Unit Earth consisting materials covered in item 1 in accordance to RDSO Spec No RDSO/SPN/197/2008 or latest Digging of earth to the required depth Insertion of electrodes - 1 Nos Filling of earth enhancing compound, provision of exothermic weld connection on copper tape of 25mmx 6mmx 150mm to the earth electrodes. (All materials tools and fixtures required for the weld to be arranged by the contractor) -5No. 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor)- 1 No. Provision of exothermic weld connection on copper tape of 25mm x 6mm x 150mm to the earth electrodes (All materials tools and fixtures required for the weld to be arranged by the contractor) - 1 No. Provision of exothermic weld one to connecting cable to the earth electrodes and another to the copper tape to be fixed inside the Equipment/Relay rack/apparatus room (features for mounting the copper tape inside the relay room, weld materials, tool, fixtures and other materials required for the weld shall be arranged by the contractor). | Numbers | 30.00 | 13,066.71 | 3,92,001.3 |
| 63 | Supply,Erection,Testing & Commission of 15 ltrs capacity of stationary storage type electric water heater closed/Vented type suitable for 240 Volts single phase AC,5 star rated,50 Hz supply ISI Marked to IS:2082 (Latest).Outer container shall be made of ABS material of inner tank container is vitreous enamelled inner tank conforming to IS13273 & Finished in either white stove enamel paint or powder coated in white color storage electric water heater shall be complete in all respect with fittings as per general technical requirements. | Numbers | 8.00 | 5,919.93 | 47,359.44 |
| 64 | Wiring for submain with 10 sqmm PVC insulatedsingle core unsheathed stranded Copper conductorISI marked cable in recessed PVC pipe of ISImarked and running of 16 SWG/(1.5sqmm PVCinsulated single core unsheathed stranded Copperconductor) copper earth wire duly clamped withpipe and providing multi-way connector on MSswitch box for neutral looping etc. as required andas per relevant technical specification....2 x 10 sqmm | Metre | 4000.00 | 158.83 | 6,35,320 |
| 65 | Provision of Geyser points having MCB 32 A S/Pwith 3/5 pin 5/15 amps plug points with 1.5 sqmm(22/0.3mm) / 2.5 sqmm (36/0.3mm) PVC insulatedsingle core unsheathed stranded Copper conductorISI marked in recessed PVC pipe of ISI marked andMS switch box having wall thickness 16 SWG including providing and fixing 3/5 pin 5/15 Amps socketoutlets and 5/15 Amps piano type switch andearthing the 3rd pin with 16 SWG/(1.5sqmm PVCinsulated single core unsheathed stranded Copperconductor) Copper earth wire along with pipe dulyclamped as required and as per relevant technicalspecification. ( 15 AMP). | Numbers | 20.00 | 420.38 | 8,407.6 |
| 66 | Supply, fixing, testing, connecting andcommissioning of wall mounted Bracket Fan 400 mm including associated works as per relavant technical specification.Make | Numbers | 10.00 | 1,693.48 | 16,934.8 |
| 67 | Supply,fixing,testing,connecting and commissioning of LED Type 12 watt LED Surface panel round spot light,suitable for 230 Volts,50 Hz AC supply with wiring and flexible PVC pipe as requires Make-Havells, orient or ISI Marked. | Numbers | 60.00 | 1,329 | 79,740 |
| 68 | Supply, fixing, installation &commissioning of weather proof LED flood light luminairecomplete 150 watt, IP ratings66system efficiency (Im/W)100, color temp (K) 5700, CRI70, Housing LM6 highpressure die castaluminium,cover glass mountingwall/bracket, THD<20%Pf>0.95, operating voltage140-270 V AC 50 Hz . ( as perspecification attached intender document ) | Numbers | 100.00 | 7,779 | 7,77,900 |
| 69 | Shifting work of HT/LT Panels/ Transformers /DG set, Reinstallation, commissioning & testing of all (foundation not included) with provision of tripping arrangement through control circuit | Job | 4.00 | 24,648.12 | 98,592.48 |
| 70 | LT fault location charge with transportation charges | Job | 4.00 | 6,952.01 | 27,808.04 |
| 71 | "Supply, fabrication, erection, testing & commissioning of weather proof floor mounted dust and vermin proof Battery Charging points suitable for operation on 150 Volts D.C. supply system fabricated with 14 SWG MS sheet / GI sheet, MS chanel size 100x50 mm (weight 7.914 Kg.Mtr) 1200 mm long, complete with locking arrangement, painted(inner & outer) inner connection with solid core , PVC insulated copper conductor cable size 10 sqmm, Alumn. bus bar of size 25x10 mm complete with one no. MCB DP 60 AMP (DC series) as per Tech specification and drawing including vertical grouting of MS channel 300 mm deep with cement sand and concrete mixture for erection. " | Numbers | 10.00 | 3,562.17 | 35,621.7 |
| Schedule total | ₹1,94,86,508 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .