REPAIR / MAINT TO LT FEEDER PILLER BOX, SWITCH GEARS SYSTEM, LT UG CABLE AND CONNECTED WORKS IN TECHNICAL AREA AT AFS UNDER GE (AF) JORHAT
2024_MES_657603_1
8635/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) JORHAT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹84,000
Yes
2 Jul 2024
4 Jun 2024
27 Jun 2024
4 Jun 2024
25 Jun 2024
19 Jun 2024
Amount
Taking down / out unserviceable or serviceable UG cables of any cross sectional area and connections including bricks, GI pipe, etc. of any descriptions, laid in trenches and /or fixing with walls /poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc, and keep in safe custody for re-use complete all as specified and as directed. NOTE :- Earth work shall be measured and paid for separately under relevant items).
Excavation in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 250mm thick in soft/loose soil complete all as specified and as directed.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and as directed.
M&L for cable in trenches/passing through pipe/on wall, XLPE insulated, heavy duty, galvanished steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 6 sqmm 4 core. Note :- Rate of the saddle and clamp for fixing of cable on wall included in this rate.
All as per Serial Item No. 5 here-in-before but of size 10 Sqmm 4 core.
All as per Serial Item No. 5 here-in-before but of size 25 Sqmm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 50 Sqmm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 70 Sqmm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 240 Sqmm 3.5 core.
All as per Serial Item No. 5 here-in-before but of size 300 Sqmm 3.5 core.
Re-laying / Re-routing or Passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy Duty) with aluminium conductor, HT/LT cable of size from 16 sqmm to 50 sqmm of any core of any size including brass compression cable gland, terminal Lug, etc complete all as specified and as directed. NOTE :Necessary excavation and earth work, brick and sand to be measured and paid seperetely.
All as per Serial item No. 12 here-in-before but of size from 70 to 95 Sqmm of any core.
All as per Serial item No. 12 here-in-before but of size from 120 to 185 Sqmm of any core.
All as per Serial item No. 12 here-in-before but of size from 240 to 400 Sqmm of any core HT/LT cable.
M&L for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consilidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note :- For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for).
S&F for sub-class 'B' brick, well burnt, laid breadth-wise along the length of cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and as directed.
M&L for laying only old serviceable bricks perpendicular to UG cable over the dry sand cushioning, for cable protection complete all as specified and as directed.
Taking down / out unserviceable GI / HDPE pipes of any descriptions, laid in trenches and / or fixing with walls / poles complete all as specified and as directed.
S&F as in repair 50 mm high density polyethylene pipe (HDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
S&F and fixing as in repair galvanised iron pipe 80 mm Bore (dia) 'light grade' for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc complete all as specified and as directed.
S&F and fixing as in repair Galvanised iron pipe 50 mm Bore (dia) 'light grade' for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc complete all as specified and as directed.
Labour only for horizontal boring for passing protection pipe up to 80 mm bore (dia), under road/ foot path, not exceeding 10 m in a single length complete all as specified and as directed. Note :- Pipe to be measured and paid separately.
S&F as in repair straight through cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium stranded conductor, nominal cross-sectional area 25 Sqmm to 50 Sqmm, 3 and half / 4 core and testing complete all as specified and as directed.
All as per Serial item No. 24 here-in-before but of nominal cross-sectional area exceeding 70 Sqmm, 3 and half / core and testing.
All as per Serial item No. 24 here-in-before but of nominal cross-sectional area exceeding 95 Sqmm, 3 and half core and testing.
All as per Serial item No. 24 here-in-before but of nominal cross-sectional area exceeding 120 Sqmm, 3 and half / 4 core and testing.
All as per Serial item No. 24 here-in-before but of nominal cross-sectional area exceeding 240 Sqmm to 300 Sqmm, 3 and half / 4 core and testing.
All as per Serial item No. 24 here-in-before but of nominal cross-sectional area exceeding 400 Sqmm, 3 and half / 4 core and testing.
S&F as in repair cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm and testing complete all as specified and as directed.
All as per Serial item No. 30 here-in-before but cable size 120 Sqmm to 185 Sqmm
Supply and fixing as in repair cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm and testing complete all as specified and as directed.
All as per Serial item No. 32 here-in-before but cable size 120 Sqmm to 185 Sqmm
S&F as in repair BTC wire for service wire connection 1100 volts grade heavy duty weather proof flat cable PVC insulated stranded aluminium conductor, twin core cable (BTC) of size 4 Sq.mm complete all as specified and as directed.
All as per Serial item No. 34 here-in-before but size 2 core 6 sq.mm
S&F as in repair GI strip 32 x 6.0 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length for extension of earthing strip on roof/ wall and joining the same with existing/ new earth test point including taking down old unserviceable one complete all as specified and as directed.
M&L for repairing of LT existing panel doors welding, cutting, inches, nuts, bolts, including doors hinges material, cleaning/ dressing of inner and outer part, crimping, replacement of gland, lungs, terminal nuts and bolts, bus bar, MCCB, etc. complete all as specified and as directed. Note :- Item such as gland, lugs, terminal nuts and bolts, bus bar, MCCB etc. to be measured and paid separately.
Material and labour for painting of LT panel/ feeder pillar any size after cleaning the body surface inner side and outer side by rubbing with emery paper to remove rust, dust, etc. and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for painting of transformer/ AVR of 100 KVA to 630 KVA in any size after cleaning the body surface outer side by rubbing with emery paper to remove rust, dust, etc and applying two coat of synthetic enamel weather proof paint complete all as specified and as directed.
M&L for cleaning & painting to all metal parts of 33/11 KV main receiving station yard of size 40 mtr x 15 mtr comprising of incomer iron structure, 02 Nos CT, 12 Nos PT, 16 Nos HT pole, 25 Nos Iron structure, 03 Nos transformer with complete accessories, painting with two coats of aluminium paint on HT pole and two coat of smoke grey on iron structure and CT/PT with white lime wash to all PCC/Brick structure, external surfaces of all platform complete all as specified and as directed.
S&F and fixing as in repair cable route marker of 350 mm height including grouting and painting HT/LT cast iron complete all as specified and as directed.
M&L for mild steel nuts, bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long and diameter of neck 5 to 10 mm, complete all as specified and directed.
Supply & fixing aluminium lugs of following sizes :-
S&F as in repair MCCB 4 Pole 63 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB form site complete all as specified and directed.
All as per Serial Item No. 44 here-in-before but of 125 Amp MCCB.
All as per Serial Item No. 44 here-in-before but of 160 Amp MCCB, breaking capacity 36 KA.
All as per Serial Item No. 44 here-in-before but of 250 Amp MCCB, breaking capacity 36 KA.
All as per Serial Item No. 44 here-in-before but of 400 Amp MCCB, breaking capacity 36 KA.
All as per Serial Item No. 44 here-in-before but of 630 Amp MCCB, breaking capacity 36 KA.
S&F as in repair 10 KVA 'C' curve miniature circuit breaker (MCB) of SPN 32 AMP including taking out existing UNSV / burnt MCB from site complete all as specified and directed.
S&F as in repair 10 KVA 'C' curve miniature circuit breaker (MCB) of SPN 40 AMP to 63 AMP including taking out existing UNSV / burnt MCB from site complete all as specified and directed.
S&F as in repair 10 KVA 'C' curve miniature circuit breaker (MCB) of TP 25 to 63 AMP including taking out existing UNSV / burnt MCB from site complete all as specified and directed.
S&F as in repair 10 KVA 'C' curve miniature circuit breaker (MCB) of TP 40 to 100 AMP including taking out existing UNSV / burnt MCB from site complete all as specified and directed.
S&F as in repair changer over switch (SS Enclosure) complete with of capacity 200 Amp, 415 Volt, 4 pole, 50 HZ.
S&F as in repair changer over switch (SS Enclosure) complete with of capacity 400 Amp, 415 Volt, 4 pole, 50 HZ.
S&F as in repair copper strip 20 x 3.15 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length on roof / wall of building and joining the same with existing/ new earth test point including taking down old unserviceable one complete all as specified and directed.
S&F only power contactor of various capacity including taking out old unserviceable one complete all as given below.
600 Amps, 4 Pole with 2 No & 2 NC auxilary contacts of coil rating 415 volt, 50 Hz.
400 Amps, 4 Pole with 2 No & 2 NC ausilary contacts of coil rating 415 volt, 50 Hz.
250 Amps, 4 Pole with 2 No & 2 NC ausilary contacts of coil rating 415 volt, 50 Hz.
M&L for PCC type B-2 (by using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete for road complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded broken stone aggregate) as in coping and footing for poles etc including necessary form work complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F of cubical housing cabinet type LT panel board OUT door type, platform mounted factory made, totally enclosed dust and varmin proof openable form both front and rear side made out of 14 SWG (3.15mm) thick CRCA MS Sheet of overall and built upon suitable size angel iron frame work, having front and rear hinged doors, GI earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and pasivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and spply powder coated paint (RAL-7032) the panel should be suitable for 415 volts, 50 Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following :-
BUS BAR CHAMBER Sheet steel bus bar chamber having front hinged covers with a set of electrocytic grade high conductivity TP&N solid aluminium bus bars, rated 1000 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification SET of 4 - 01 No.
INCOMER Changeover switch 320 Amp - 01 No MCCB 320 Amp, 36 KA, 415 Volt, 50 Hz, 4 pole thermal magnatic type - 01 No
OUTGOING FEEDERS MCCB 160 Amp, 25 KA, 415 Volts, 50 Hz, 4 pole thermal magnatic type - 01 No MCCB 125 Amp, 16 KA, 415 Volts, 50 Hz, 4 pole thermal magnatic type - 02 Nos MCCB 63 Amp, 16 KA, 415 Volts, 50 Hz, 4 pole thermal magnatic type - 02 Nos
S&F as in repair notice board pinup type, softboard core, framed in double-sided carved aluminium section and silver anodized with plastic corners and with necessary hanging arrangement on the wall complete all as specified and directed.
M&L for painting of LT electric pole, steel tubular swaged pole (8.5 mtr to 9 mtr long) of any size, any pattern with one coat of aluminium paint over a coat of red oxide primer in full length of the pole and marking the pole with black and yellow strip (upto 1 mtr length, 1 mtr height of PCC coping) alternatively including numbering the pole serially complete all as specified and directed.
M&L for surface dressing/ cleaning of various electric sub station premises free from vegetation of any type including trimming of tree branches, bushes, creepers, etc complete all as specified and directed. Note : - The frequency of surface dressing shall not be less than 1 months between subsequent trimming/ cutting.
S&F as in repair XLPE insulted, screened, PVC bedded, galvanished steel strip or wire armoured, electric power cables (heavyduty) with aluminium conducor, 11 KV Earthed, grade cross sectional are 95 Sqmm 3 core complete all as specified and directed.
M&L for broken boulders aggregate for loose filling near around electric switch yard/ electric equipment, of gauge 40 m to 80 mm graded, also surface dressing as when as required complete all as specified and directed.
M&L for earthing complete with MS galvanized plate of size 60 cm x 60 cm x 6 mm as earth electrode, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, conneted to galvanised iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part -I of 2009 connected to earting test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover having suitable handle (10mm MS Rod0 20 mm dia GI medium grade watering pipe with GI funnel with wire mesh 40 mm bore GI pipe medium grade ISI marked0 for protection of earth lead conductor and testing on completion complete all as specified and directed. Note:- The contract sum shall be calculated by deducting the amount shown in schedule of credit attached to this tender, from total amount of Schedule 'A'/BOQ
M/S Deep Construction
M/S PAUL CONSTRUCTION
TANKESWAR BORA
M/S SR CONSTRUCTIONS
Chief Builders &Consultants
THE SUPPLY AGENCY
M/S SAIKIA ENTERPRISE
Bidder Name
THE SUPPLY AGENCY
M/S Deep Construction
TANKESWAR BORA
M/S SR CONSTRUCTIONS
M/S PAUL CONSTRUCTION
Chief Builders &Consultants
M/S SAIKIA ENTERPRISE
M/S BARUAH ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .