Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹4.6 L+₹30,724 (7.14%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹4.9 L+₹59,670 (13.9%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹6.7 L+₹2.4 L (55.2%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest |
Tender Value
Refer Docs
EMD Value
₹9,800
Closing Date
16 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
WORK SERVICE FOR INSTALLATION OF SNS JAMMER AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2023_MES_580162_2
8122/SAR-68/2022-23
Open Tender
Civil Works
Item Rate
90 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹9,800
Yes
28 Mar 2023
28 Feb 2023
18 Mar 2023
28 Feb 2023
16 Mar 2023
28 Feb 2023
Amount
Providing and laying 50mm thick for precast SFRC drain cover without frame but including complete sides iron sheets (medium ) complying to the standard specifications as mentioned in the IS 12592 BIS Standard minimum load bearing capacity 2 to 3 ton /Sqm in square or rectangular shape complete all as specified and directed by Engr-in-Charge.
S&F Air cooled servo voltage stabliser confirming to BIS 9815 Part 1 :1994) single phase naturally air cooled copper wound metallic body duly powder coated digital display type relay free input voltage 160V -260V , output voltage stablised 240V +/-1% , Rate of correction 8 Volt/second efficiency more than 95 % with over load /Short circuit protection , High / Low voltage cut off of capacity 10 KVA complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoured electric power cable with stranded aluminium conductor, of cross sectional area 10 Sqmm 2 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
Supply and fixing of Earthing with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 4.0 sqmm galvanised iron wire by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 15 mm dia medium grade and connected to distribution board including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade including testing on completion complete all as specified and as directed.
Supply, installation, commissioning and testing of Advance Maintenance Free environment friendly ring earthing system. Each set consisting of 3 Nos of 10 feet length, 17.2 mm dia earth electrode made of high tensile low carbon steel circular rods, molecularly bonded cooper on outer surface (minimum copper bonding thickness - 250 microns) with terminals to connect incoming strip with 3 bags (60 Kg each ) of environment friendly Portland cement based backfill compound (Resistivity below 0.15 ohm) for each bore as per manufacturing instructions with ROHs test certificate for each 150 x 25 x 6 mm Copper Bar with 4 hole shall be exothermically welded on top to copper bonded rod to terminal laid in a bore of dia 300 mm which inner dia of size 150 mm fill with backfill material and outer bore fill with 100Kg Bantonite in each bore. 25 x 3 mm copper strip shall be used to interconnect the earths and to make the ring and earth pit cover polypropylene (300 mm x 300 mm) duly enclosed in PCC pit of size 600 x 600 x 100 mm shall be included in the scope of work. Make: OBO/JEF ECO SAFE/ENNOV Note: (i) Earthing shall be tested after completion of work by contractor in presence of Engr-in-Charge and proper record shall be maintained duly signed by all concerned. On testing if the desired earth resistance of less than 1.0 Ohm is not obtained the earthing will be redone at no extra cost to Govt. (ii) The cooper strip from earthing to and upto Eqpt shall be measured and paid separately under relevant item. (iii) Rates are inclusive of Test point.
Supply and fix copper strip of size 20x3.15 mm for Earth continuity conductor or main earthing lead fixed wall/ roof with saddles and fixing screws etc. for roof conductors and down conductors above ground or any other indicated situation complete all as specified and directed. Note:- Two lengths of strips shall be jointed together by overlapping not less than 100 mm both ends through welding/brazing.
Supply and fix UPS of capacity 10 KVA having output power capacity 8000 W with online double conversion VFI-SS-111 technology sinusoidal waveform LED+LCD display , input characterstics 230 VAC, 50-60 Hz +/- 5% auto sensing, voltage range 110V-300 VAC @50% load, power factor >0.99, THD of input current < 10%, DC voltage 192-240 V, output characterstics 230 VAC +/-1% , 50 Hz, single phase for 30 min back up with SMF battery 12V * 42 AH * 16 Nos battery,over load capacity at 105 - 110% is 3 minute and at 111 - 130 % is 3 sec including suitable size rack and link arrangement complete all as specified and directed.
Supply and fixing MCB DP 40 Amp , in sheet metal enclosure outdoor type floor mounnted with legs complete with necessary exacavation , PCC work complete all as specified and directed b Engr-in-charge.
S & F sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn into new casing caping with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor shall be a unit length.
S & F sub main wiring with PVC insulated, fire retardant (FRLS), unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 2.5 sqmm (Nominal area) drawn into new casing-caping with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor shall be a unit length.
S&F sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 6 ways 240 V complete all as specified and as directed .
S&F MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F MCB SPN 16 to 40 Amps, 240 volts, curve 'B', breaking capacity 10 KA, all as specified.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16 Amp complete all as specified and directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
M&L for PVC rectangular block for mounting for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of sizr 175 x 100 x 50 mm deep with all connecting accessories complete all as specified and directed.
S&F switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2-in-1, 3 pin 5 amp and 15 amps all as specified and directed.
S & F PVC flexible conduit of size 50 mm (external dia) ISI marked with fastening clamp complete all as specified and directed.
M & L Earth continuity conductor or main earthing lead of 4.0 Sqmm galvanized iron wire, buried in ground or fixed to wall complete all as specified and directed..
Supply and fix extension board with 4 Nos universal socket, fuse , 240 V ,1440 watt , 1.5 mtr extension cord with plug top complete all as specified and directed by Engr-in-charge.
S & F of Regid non-metallic PVC conduit 25 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
S & F of Regid non-metallic PVC conduit 20 mm (external dia) ISI marked (on surface) incl of all accessories and all fittings such as Tees bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers lock nuts, saddles, pipe hook etc complete all as specified and as directed.
RAJAN TRADERS
BRIJ CONSTRUCTIONS
SHRI RAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .