Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.9 L+₹1.1 L (2.31%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.5 L+₹1.7 L (3.53%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.9 L+₹2.0 L (4.25%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹50.2 L+₹2.4 L (5.01%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Biswas Brothers Co L7 | SURESH JHA L2 | ADHIKARY CONSTRUCTION L4 | M/S ASOKE KUMAR MAJUMDER L5 | M/S DUTTA & DAS ENGINEERING CO. L6 | D.D. BROTHERS L1 | M/S AJIT GARAGE L8 | J.S.M. FURNITURE L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old unserviciable copper /aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures, removing materials to store for keeping in safe custody or for taking credit all as directed making good disturbed surfaces of walls with putty, cement and matching the colour of the surface as per existing. | 1,896 | PER POINT | 37 ₹70,152 | 36 ₹68,256 | 38 ₹72,048 | 33 ₹62,568 Lowest | 40 ₹75,840 | 35 ₹66,360 | 34 ₹64,464 | 40 ₹75,840 |
| 2.00 | Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete.
NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps | 450 | PER POINT | 870 ₹3,91,500 | 850 ₹3,82,500 | 845 ₹3,80,250 | 856 ₹3,85,200 | 870 ₹3,91,500 | 830 ₹3,73,500 Lowest | 886 ₹3,98,700 | 880 ₹3,96,000 |
| 3.00 | All as per Item Sl No - 02 here in before but for one light point controlled by two 2 way switches complete all as specified and directed. | 4 | PER POINT | 935 ₹3,740 | 915 ₹3,660 | 940 ₹3,760 | 950 ₹3,800 | 970 ₹3,880 | 895 ₹3,580 Lowest | 984 ₹3,936 | 925 ₹3,700 |
| 4.00 | All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed. | 80 | PER POINT | 870 ₹69,600 | 850 ₹68,000 | 860 ₹68,800 | 856 ₹68,480 | 885 ₹70,800 | 830 ₹66,400 Lowest | 886 ₹70,880 | 880 ₹70,400 |
| 5.00 | All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed. | 15 | PER POINT | 205 ₹3,075 | 200 ₹3,000 | 190 ₹2,850 | 202 ₹3,030 | 195 ₹2,925 | 195 ₹2,925 | 209 ₹3,135 | 185 ₹2,775 Lowest |
| 6.00 | All as per Item Sl No - 02 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed. | 65 | PER POINT | 1,030 ₹66,950 | 1,000 ₹65,000 | 1,025 ₹66,625 | 1,089 ₹70,785 | 1,050 ₹68,250 | 985 ₹64,025 Lowest | 1,128 ₹73,320 | 1,025 ₹66,625 |
| 7.00 | Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm for moduler fittings (excluding MS sunk terminal box & hylum sheet) for one light / fan point / call bell controlled by one switch one way 5 Amps complete.
NOTE : (i) Modular fitting will be measured & paid under relevent items seprately (ii) Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed. | 250 | PER POINT | 870 ₹2,17,500 | 850 ₹2,12,500 | 865 ₹2,16,250 | 856 ₹2,14,000 | 890 ₹2,22,500 | 830 ₹2,07,500 Lowest | 886 ₹2,21,500 | 880 ₹2,20,000 |
| 8.00 | All as per Item Sl No - 07 here in before but for one light point controlled by two nos. 2 way switches for modular fitting completed all as specified and as directed.(Note: Modular fitting will be measured & paid under relevent items separately) | 2 | PER POINT | 905 ₹1,810 | 885 ₹1,770 | 910 ₹1,820 | 920 ₹1,840 | 940 ₹1,880 | 865 ₹1,730 | 953 ₹1,906 | 850 ₹1,700 Lowest |
| 9.00 | All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the independent board complete but for modular fittings excluding MS sunk terminal box & hylum sheet. (Note: Modular fitting will be measured & paid under relevent items seprately). | 70 | PER POINT | 870 ₹60,900 | 850 ₹59,500 | 835 ₹58,450 | 856 ₹59,920 | 860 ₹60,200 | 830 ₹58,100 Lowest | 886 ₹62,020 | 880 ₹61,600 |
| 10.00 | All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the same board complete but for modular fittings excluding MS sunk terminal box & hylum sheet. (Note: Modular fitting will be measured & paid under relevent items seprately). | 25 | PER POINT | 205 ₹5,125 | 200 ₹5,000 | 190 ₹4,750 | 202 ₹5,050 | 195 ₹4,875 | 195 ₹4,875 | 209 ₹5,225 | 175 ₹4,375 Lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
21 Jul 2025, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR TO INTERNAL ELECTRIFICATION, FAN AND CONNECTED WORKS AT BANA SINGH BIHAR AREA OF SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2025_MES_717629_1
8496/SEV OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUS
8 documents required · 8 mandatory
₹500
GE SEVOKE ROAD
₹94,000
16 Oct 2025
30 Jun 2025
23 Jul 2025
30 Jun 2025
21 Jul 2025
15 Jul 2025
1 Jul 2025 - 10 Jul 2025
Amount
Taking down carefully old unserviciable copper /aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures, removing materials to store for keeping in safe custody or for taking credit all as directed making good disturbed surfaces of walls with putty, cement and matching the colour of the surface as per existing.
Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.One light/fan/call bell point controlled by one switch one way 5 Amps
All as per Item Sl No - 02 here in before but for one light point controlled by two 2 way switches complete all as specified and directed.
All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the independent board complete all as specified and directed.
All as per Item Sl No - 02 here in before but for 5 pin, 5/6 A socket point on the same board complete all as specified and directed.
All as per Item Sl No - 02 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5 sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete all as specified and directed.
Materials and labour for concealed point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm for moduler fittings (excluding MS sunk terminal box & hylum sheet) for one light / fan point / call bell controlled by one switch one way 5 Amps complete. NOTE : (i) Modular fitting will be measured & paid under relevent items seprately (ii) Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates. all as specified and directed.
All as per Item Sl No - 07 here in before but for one light point controlled by two nos. 2 way switches for modular fitting completed all as specified and as directed.(Note: Modular fitting will be measured & paid under relevent items separately)
All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the independent board complete but for modular fittings excluding MS sunk terminal box & hylum sheet. (Note: Modular fitting will be measured & paid under relevent items seprately).
All as per Item Sl No - 07 here in before but for 5 pin, 5/6 A socket point on the same board complete but for modular fittings excluding MS sunk terminal box & hylum sheet. (Note: Modular fitting will be measured & paid under relevent items seprately).
All as per Item Sl No - 07 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 2.5 sqmm green in colour as earth lead for 15/16 A switch -socket point on independent board complete but for modular fitting excluding MS Sunk terminal box & hylum sheet.(Note: Modular fitting will be measured & paid under relevent items seprately).
Material & labour for wiring in existing conduit with two single core PVC insulated, unsheathed, multistranded copper conductor FRLSH of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor FRLSH of size 1.50 sqmm green in colour as earth lead including provn of MS sunk terminal box of appropriate size suitable for flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / call bell complete all as specified and directed by Eng-in-charge. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
Material and labour for point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC casing caping (medium grade) with all fittings & accessories including provn of MS sunk terminal box of minimum size 75 x75 mm fixed flush to wall for mounting switch, socket, fan regulator etc with 3mm thick hylum sheet top cover with screws & cup washers for one light / fan point / complete.. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per Item Sl No - 13 here in before but for 5 pin, 5/6 A socket point on the independent board complete.
All as per Item Sl No - 13 here in before but for 5 pin, 5/6 A socket point on the same board complete.
All as per Item Sl No - 13 here in before but with two single core PVC insulated, unsheathed, multistranded copper conductor of size 2.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 2.5sqmm green in colour as earth lead for 15/16 A switch-socket point on independent board complete.
Supply and Fixing switch piano flush type single, pole one way, 5 Amp completed all as specified and as directed.
Supply and Fixing switch piano flush type single, pole two way, 5 Amp completed all as specified and as directed.
Supply and Fixing ceiling rose, surface PVC 25mmx50mm 3/2 terminals completed all as specified and as directed.
Supply and Fixing in repair lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed
Supply and Fixing switch socket combination 5 in 1, 5/6A completed all as specified and as directed.
Supply and Fixing Bell push flush type 5 amp, 240 volts completed all as specified and as directed.
Supply and Fixing Bell Ding Dong AC , 230 volts single pole completed all as specified and as directed.
Supply and Fixing switch socket combination 5 in 1, 15/16A completed all as specified and as directed.
Supply and Fixing socket outlet 5 in 1,5A completed all as specified and as directed.
Supply and Fixing electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
Taking down existing unservisiable FTL light fitting and S&F decorative box type fitting with LED tube 9/10 watt 2 feet with Aluminium extruded batten luminaire for 230 volt AC complete all as directed by Engineer in Charge
Taking down existing unserviceable FTL light fitting and S&F decorative batten type fitting with LED light fitting 20 watt 4 feet with Al extruded batten luminaire for 230 volt AC all as directed.
Taking down existing unserviceable light fitting and S & F sparkle down light 8 Watt 220 Volts AC including driver and accessories,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F round shape 15-20 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F new round shape 12 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers,holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
Taking down existing unserviceable light fitting and S & F new LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down existing unserviceable light fitting and supply and fixing in repair wall fancy light fitting with holder point 230 volts necessary fixing arrangement complete all as specified and directed.
Taking down existing unserviceable light fitting and supply and fixing picture light upto 12 W and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in repair MCB distrubution board TPN 4way, double door, IP 43, IK-09, sheet steel, phosphatised,powder coated with 200 amps rated bus-bar,neutral link,earth bar and din rail, 415 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 12 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 8 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and fixing in repair MCB distrubution board SPN 4 way, double door, IP 43, IK-09, sheet steel, phosphatised, powder coated with 200 amps rated bus-bar,neutral link, earth bar and din rail, 240 V, including taking down existing unserviceable DB with MCBs complete all as specified and directed. by Engineer-in-charge.
Supply and Fixing MCB, SP, 10KA, 230V, "C" curve, 06-32 A, ISI Marked complete all as specified and directed.
Supply and Fixing MCB, DP, 10KA, 415V, "C" curve, 06-32 A, ISI Marked complete all as specified and directed.
Supply and Fixing MCB, TPN, 10KA, 415V, "C" curve, 40/63 Amp, ISI Marked complete all as specified and directed.
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 1.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 1.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 2.5 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 2.5 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 4.0 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 4.0 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge. (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable along with conduit altogether shall be measured as one unit)
Materials &Labour for concealed submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor, FRLSH, of size 6.0 Sqmm and one single core PVC insulated, unsheathed stranded copper conductor FRLSH, of size 6.0 Sqmm green in colour as earth continuity conductor connected to existing main switch board / distribution board of each building / qtr as ordered, drawn into and including 20 mm dia PVC conduit (medium grade) with all fitting & accessories and testing on completion including taking down old unserviceable sub-main wiring complete all as specified and directed by Eng-in-Charge . (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable along with conduit altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 6.0 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 6.0 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring in existing conduit with two single core PVC insulated, unsheathed, FRLSH stranded copper conductor of size 4.0 Sqmm and one single core PVC insulated, unsheathed solid copper conductor 4.0 Sqmm green in colour as earth lead in existing cancealed PVC conduit with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring from existing concealed conduit complete all as specified and directed by Eng-in-Charge (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 2.5 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 2.5 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
Material and labour for submain wiring with and including PVC casing caping with two single core PVC insulated, FRLSH unsheathed, stranded copper conductor of size 4.0 Sqmm one single core PVC insulated, FRLSH unsheathed solid copper conductor 4.0 Sqmm and green in colour as earth lead with all fitting & accessories including taking down old unserviceable aluminium sub-main wiring complete all as specified and directed (Note: Two runs of 4 Sqmm cable and one run of 4 Sqmm earthing cable along with casing caping altogether shall be measured as one unit.)
Supply and Fixing in repair exhuast fan AC , single phase, 230/240 V, of size 300 mm seep hevy duty steel/aluminium metal body including making holes on wall & making good the disturbed surfaces with all connceting arrangements complete all as specified and as directed.
Supply and Fixing in repair exhuast fan AC , single phase, 230/240 V, of size 230-250 mm seep hevy duty steel/aluminium metal body including making holes on wall & making good the disturbed surfaces with all connceting arrangements complete all as specified and as directed.
Supply and Fixing in repair exhuast fan AC , single phase, 230/240 V, of size 450 mm seep hevy duty steel/aluminium metal body including making holes on wall & making good the disturbed surfaces with all connceting arrangements complete all as specified and as directed.
Supply and Fixing in repair ventilation fan with louvers, single phase, 230/240V, of size 200-250mm sweep polycarbonate body, rustproof body & blades, low noise and weight, making good the distrubed surface with all connecting arrangements complete all as specified and directed.
Supply and Fixing in repair ventilation fan with louvers, single phase, 230/240V, of size 150 mm sweep polycarbonate body, rustproof body & blades, low noise and weight, making good the distrubed surface with all connecting arrangements complete all as specified and directed.
Supply and Fixing in replacement LED building security light of capacity 35 watt in Aluminium PDC housing , toughned glass cover with IP66 protection completed all accessories with frame and connecting PVC copper wire not exc 5 mtrs complete all as specified and directed.
Materials and Labour for GI bracket made out of 25 mm bore medium grade GI Pipe with two sets of clamps grouted in wall with four number of wall fastners , bend to shape all as directed, length of GI Pipe shall not be less than 1.5 meter for fixing of light fitting including taking out old unservicable bracket complete all as specified and as directed.
Supply and Fixing modular switch one way 6 Amps 230 volts, 1 module all specified and as directed by the Engineer in Charge
Supply and Fixing modular bell push switch one way 6 Amps 230 volts, 1 module all specified and as directed by the Engineer in Charge
Supply and Fixing modular bell push switch two way 6 Amps 230 volts, 1 module all specified and as directed by the Engineer in Charge
Supply and Fixing modular switch one way with indicator 16 Amps 230 volts, 1 module all specified and as directed by the Engineer in Charge
Supply and Fixing modular socket 2 in 1, 2/3 pin, 6 Amp all as specified and as directed by the Engineer in Charge.
Supply and Fixing moduular socket 3 pin 6 Amp-16 Amp combined shuttered all as specified and directed by Engineer in Charge.
Supply and Fixing modular white cover plate with frame 1 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 2 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 3 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 4 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 6 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 8 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular white cover plate with frame 12 module inclusive of inner & outer plate complete all as specified and as directed by the Engineer in Charge.
Supply and Fixing modular metal flush box 1/2 module all as directed
Supply and Fixing modular metal flush box 3 module all as directed
Supply and Fixing modular metal flush box 4 module all as directed
Supply and Fixing modular metal flush box 6/8 module all as directed
Supply and Fixing modular metal flush box 12 module all as directed
Supply and Fixing modular electronic step regulator (speed regulation in 5 steps) 1 module suitable for ceiling fan 1200 /1400 mm sweep, 100 watt complete.
Supply and Fixing PVC casing caping (medium grade) of size 25x16 mm with all connecting accessories all as per directed.
Supply and Fixing PVC box with SSC 5/6 A complete all as specified and directed
Supply and Fixing PVC box with SSC 15/16 A complete all as specified and directed
Supply and Fixing in repair LED warm or any colour bulb threaded/non threade type 2-5 W 230 V complete all as specified and directed
Taking down old unserviceable ceiling fan and depositing to MES store and supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) with remote control complete all as specified and directed
Taking down old unserviceable ceiling fan and depositing to MES store and supply and fixing non BLDC ceiling fans( preferabaly white or cream colour) complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep
Taking down ceiling fan,exhaust fan and wall fan from any location and any height , removing fan blades and caried to workshop for repair/rewinding and refixing the same after repair all as directed by Engineer-in-Charge.(Note:- Cost of repair/rewinding will be measure and saparatly under relevant items).
Materials &Labour for rewinding of ceiling fan of size 1200/1400mm sweep with super enamelled copper winding wire of existing gauge, reassembling the same all as directed .
MMaterials &Labour for rewinding of exhaust fan of size upto 300mm sweep with super enamelled copper winding wire of appropriate gauge for any make or model , reassembling and testing complete all as directed.
Materials &Labour for rewinding of exhaust fan of size above 300mm upto 450mm sweep with super enamelled copper winding wire of appropriate gauge for any make or model , reassembling and testing complete all as directed.
Supply and replace ball bearing No 6302 of single 'Z' or double 'ZZ' for ceiling fan including taking out old & UNSV complete all as directed
Supply and replace ball bearing No 6303 of single 'Z' or double 'ZZ' for exhaust fan/wall fan including taking out old worn out complete all as directed.
Supply and fixing in replacement capacitor 2.5 mfd 240 volts complete all as directed.
Supply and fixing in replacement capacitor 4 mfd 240 volts complete all as directed.
Supply and fixing anchor bolt/hook made of metal for hangging ceiling fan complete all as directed.
Supply and fixing in replacement down rod for hanging ceiling fan made of 15 mm bore medium grade GI pipe, 1.20m long, including rubber real and suitable nuts and bolts complete all as directed
S&F in repair plug top 3 pin 5 amps ISI marked complete all as directed
S&F in repair plug top 3 pin 15 amps ISI marked complete all as directed
Material and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 2.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one and fix with cast iron funnel and wire-mesh, with protection pipe of 32mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol, bentonite in alternate layers etc, complete all as shown in EP number 2 of SSR Part-I including testing on completion and including taking down old u/s earthing & testing complete all as specified and as directed..
SURESH JHA (BID ID -3364092)
J.S.M. FURNITURE (BID ID -3366143)
ADHIKARY CONSTRUCTION (BID ID -3364458)
M/S ASOKE KUMAR MAJUMDER (BID ID -3364952)
M/S DUTTA & DAS ENGINEERING CO. (BID ID -3365174)
Biswas Brothers Co (BID ID -3363769)
M/S AJIT GARAGE (BID ID -3364969)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .