Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.4 LAdmitted-Finance VOLTAS HOUSE B 2ND FLOOR T B KADAM MARG CHINCHPOKLI MUMBAI 400 033 | MUMBAI | MUMBAI | MAHARASHTRA | 400033 | L1 | Admitted-Finance | |
| 2 | L2₹98.7 L+₹7.4 L (8.08%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L2 | Admitted-Finance | |
| 3 | Rejected-Technical | - | Rejected-Technical Technically disqualified | |
| 4 | Rejected-Technical 10TH FLOOR UNIT 2 TECHNIPLEX 2 VEER SAVARKAR FLYOVER S V ROAD GOREGOAN WEST MUMBAI 400 062 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400062 | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | Bluestar Limited L2 | VOLTALIMITED L1 |
|---|---|---|---|---|---|
| 1.00HVAC WORKS (LOW SIDE) FAN COILS UNITS (CEILING SUSPENDED TYPE) Supply, installation, testing and commissioning of GI powder coated horizantal ceiling suspended fan coil units complete with fan, 3 speed motor, 3 row deep cooling coil, 5 mm external static, aluminium filters with filter box, insulated tray, copper connection, Canvass Connection,supporting arrangement, electrical wiring etc.The thickness of GSS sheet should be 1.25 mm & thickness of filter 15 mm. The fan shall be selected for 5 mm external static pressure. The complete fan coil unit shall be in line with the standard specification. The capacity of fan coil units shall be as follows. Proper supporting system for FCU to be provided & will be in contractor's scope. ), (Make: Carrier,Edgetech,Hitachi,Zeco) | |||||
| 1.00 | FCU-400 CFM (1 TR) | 69 | Nos | 21,492 ₹14,82,948 Lowest | 25,305 ₹17,46,045 |
| 1.00 | FCU-600 CFM (1.5 TR) | 115 | Nos | 21,863 ₹25,14,245 Lowest | 28,083 ₹32,29,545 |
| 1.00 | FCU-800 CFM (2 TR) | 18 | Nos | 22,110 ₹3,97,980 Lowest | 36,416 ₹6,55,488 |
| 1.00 | FCU-1200 CFM (3 TR) | 4 | Nos | 22,974 ₹91,896 Lowest | 41,972 ₹1,67,888 |
| 1.00 | HVAC WORKS (LOW SIDE):- Supply, Installation Testing and Commissioning of PICBV (pressure independent valves (PN-16 rated) with modulating, 2- way control device. The Valve should have self-Dynamic Flow Control Valves that are pressure independent, Modulating to accept digital/analog input BMS/Controller signals and should provide position feedback signal to the control system. It should be diaphragm type & pressure balancing valve. Pressure Drop across the valve must not exceed 20 kpa up to DN 32 and 30 Kpa in bigger Sizes.Actuator should be Gear type only shall be rated to IP54. Valve shall be of Brass Construction up to DN32 and Cast Iron up to DN150. Valve & Actuator combination should be able to give logarithmic control characteristics to achieve linear control.
PICBV 20mm Dia | 184 | Nos | 18,946 ₹34,86,064 | 9,879 ₹18,17,736 Lowest |
| 1.01 | PICBV 25mm Dia | 18 | Nos | 19,942 ₹3,58,956 | 10,857 ₹1,95,426 Lowest |
| 1.01 | PICBV 32mm Dia | 4 | Nos | 22,943 ₹91,772 | 14,395 ₹57,580 Lowest |
| 1.01 | Supply,Installation Testing and Commissioning of the following Ball Valves without strainer duly insulated as per specifications and drawings. It shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions.
Ball Valve 20mm Dia | 184 | Nos | 1,605 ₹2,95,320 | 966 ₹1,77,744 Lowest |
| 1.01 | Ball Valve 25mm Dia | 18 | Nos | 1,823 ₹32,814 | 1,245 ₹22,410 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
28 Dec 2022, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE TMC on behalf of Director TMC
Engineering Dept TMH Parel Mumbai 12
Replacement of old Fan Coil Unit and its Accessories in TMH Complex.
2022_TMC_727762_1
TMC/ENG/ReplOldFanCoil/2022/31
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
Tata Memorial Hospital Parel Mumbai 12
As per tender documents
5 documents required · 5 mandatory
₹0
₹2.6 L
Engineering Dept TMH Parel Mumbai 12
16 Feb 2023
7 Dec 2022
30 Dec 2022
7 Dec 2022
28 Dec 2022
22 Dec 2022
7 Dec 2022 - 18 Dec 2022
19 Dec 2022
Amount
FCU-400 CFM (1 TR)
FCU-600 CFM (1.5 TR)
FCU-800 CFM (2 TR)
FCU-1200 CFM (3 TR)
HVAC WORKS (LOW SIDE):- Supply, Installation Testing and Commissioning of PICBV (pressure independent valves (PN-16 rated) with modulating, 2- way control device. The Valve should have self-Dynamic Flow Control Valves that are pressure independent, Modulating to accept digital/analog input BMS/Controller signals and should provide position feedback signal to the control system. It should be diaphragm type & pressure balancing valve. Pressure Drop across the valve must not exceed 20 kpa up to DN 32 and 30 Kpa in bigger Sizes.Actuator should be Gear type only shall be rated to IP54. Valve shall be of Brass Construction up to DN32 and Cast Iron up to DN150. Valve & Actuator combination should be able to give logarithmic control characteristics to achieve linear control. PICBV 20mm Dia
PICBV 25mm Dia
PICBV 32mm Dia
Supply,Installation Testing and Commissioning of the following Ball Valves without strainer duly insulated as per specifications and drawings. It shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. Ball Valve 20mm Dia
Ball Valve 25mm Dia
Ball Valve 32mm Dia
Supply,Installation Testing and Commissioning of the following Ball Valves with Strainer duly insulated as per specifications and drawings. It shall be bronze forged body construction with chrome plated bronze ball and handle of stainless steel constructions. Ball Valve 20mm Dia
Ball Valve 25mm Dia
Ball Valve 32mm Dia
HVAC WORKS (LOW SIDE):-Supply & Installation of Digital Thermostat including all accessaries, mountings,wiring between thermostat & unit, terminations etc. Make-Siemens,Honywell,Johnsoncontrol
HVAC WORKS (LOW SIDE):-Providing and fixing in position the following UPVC Heavy class cut to required length and installed with screw joints including the necessary fittings, supporting arrangements like clamps etc. (bends, tees, unions, sockets etc) duly insulated with class "O" 6 mm thick nitrile rubber insulation as per specifications. 25 mm dia Make:-Astral/Supreme/Ashirwad,Insulation-Make:-Armacell/ ALP Aerocell/K-Flex)
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Dismantaling of old FCU of capacity 1 TR,1.5TR & 2TR,Lifting shifting etc complete in all respect as per instruction of EIC
Cat (B) - BUY BACK of FCU with Valve station,Themostate and Electrical wire
Buy-Back (ie minus)Amount of FCU-1TR with Valve station,Themostate and Electrical wire, etc related items
Buy-Back (ie minus) Amount of FCU-1.5TR with Valve station,Themostate and Electrical wire, etc related items
Buy-Back (ie minus) Amount of FCU-2TR with Valve station,Themostate and Electrical wire, etc related items
Bluestar Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.09 MB
BOQ_765388.xls
BOQ • 0.26 MB
techdocumentchecklist.xls
Tender Documents • 0.03 MB
Technicalspecifications.pdf
Tender Documents • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .