Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
10 Jun 2026, 12:00 pm5d left
SE EM Circle PWD Kanpur
SE EM Circle PWD Kanpur
Nirikshan Bhawan Lok Nirman Vibhaag Kannauj me Purane Air Conditioner sayantro ke esthan par naye Air Conditioners sayantro ke lagaye jane ka karya.
2026_CEEMP_1155212_1
935C/4C-EMC/2026-27 Dt. 20.05.2026
Open Tender
Electrical Works
90 days
Kannauj
3 documents required · 3 mandatory
₹766
EE EM Division PWD Kanpur
₹1.4 L
EE EM Division PWD Kanpur
29 May 2026
29 May 2026
10 Jun 2026
29 May 2026
10 Jun 2026
29 May 2026
2 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617. heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature).
2.0 TR with 5 Star BEE Rating Inverter type cooling only. | 18 | Nos. | 43,333.98 | ₹7,80,011.64 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617. heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature). 2.0 TR with 5 Star BEE Rating Inverter type cooling only. |
| 2 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 °C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617. heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS 1391 Part II 2023. The system shall be able to operate up to 50 °C (out door ambient temperature).
1.5 TR with 5 Star BEE Rating Inverter type cooling only. | 2 | Nos. | 32,871.95 | ₹65,743.9 | - |
| 3 | SITC of suction/Discharge copper pipe line in split A.C. up to 2.0 Ton capacity including brazing, nitrile, rubber insulation 6 mm thick class 'O' etc. complete 3/8" (9.50 mm.) and 5/8" (15.90 mm.) | 185 | Mtr. | 1,450 | ₹2,68,250 | SITC of suction/Discharge copper pipe line in split A.C. up to 2.0 Ton capacity including brazing, nitrile, rubber insulation 6 mm thick class 'O' etc. complete 3/8" (9.50 mm.) and 5/8" (15.90 mm.) |
| 4 | S/F of 5 KVA Capacity wall mounted voltage stablizer for Air Conditioner up to 2 Ton (130 V-300V)Range Copper winding. | 18 | Nos. | 5,050 | ₹90,900 | S/F of 5 KVA Capacity wall mounted voltage stablizer for Air Conditioner up to 2 Ton (130 V-300V)Range Copper winding. |
| 5 | Fabrication of cage of iron jali with outer M.S. angle for out door unit including all material and labour complete in all respectsize3.0x1.25x2.15 feet including cost and fitting of 3.0mm thick M.S. sheet onupper surface | 20 | Nos. | 5,060 | ₹1,01,200 | Fabrication of cage of iron jali with outer M.S. angle for out door unit including all material and labour complete in all respectsize3.0x1.25x2.15 feet including cost and fitting of 3.0mm thick M.S. sheet onupper surface |
| 6 | S/F of 4 KVA Capacity wall mounted Voltage Stablizer for Air Conditioner up to1.5 Ton (130v-300v )Range Copper winding. | 2 | Nos. | 4,250 | ₹8,500 | S/F of 4 KVA Capacity wall mounted Voltage Stablizer for Air Conditioner up to1.5 Ton (130v-300v )Range Copper winding. |
| 7 | S/L of Heavy duty PVC plastic braided 20mm. OD flexible pipe for condensed water drain with clipping accessories complete. | 200 | Mtr. | 160 | ₹32,000 | S/L of Heavy duty PVC plastic braided 20mm. OD flexible pipe for condensed water drain with clipping accessories complete. |
| 8 | Supply &Fixing of outdoor unit stand for split type A.C. | 20 | Nos. | 1,250 | ₹25,000 | Supply &Fixing of outdoor unit stand for split type A.C. |
| 9 | S/f of 2.5 Sq. mm. 4 Core Round cable for A.C. connecting Indoor to Outdoor Unit. | 228 | Mtr. | 160 | ₹36,480 | S/f of 2.5 Sq. mm. 4 Core Round cable for A.C. connecting Indoor to Outdoor Unit. |
| 10 | 16A 3 Pin Plug top with indicator.(Heavy duty) | 20 | Nos. | 139 | ₹2,780 | 16A 3 Pin Plug top with indicator.(Heavy duty) |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
T1.pdf
Tender Documents • 1.35 MB
BOQ_2164023.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid