Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹33.6 L+₹3.7 L (12.3%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.9 L+₹4.0 L (13.4%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹34.8 L+₹4.9 L (16.2%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹36.3 L+₹6.3 L (21.1%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹49.8 L
EMD Value
₹99,500
Closing Date
14 Apr 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
SPECIAL REPAIR TO CERTAIN OFFICES OF JCDA AT CAMERO, SPECIAL REPAIR TO OCG STORES AT AFRO AT CAMERO COMPLEX AND PROVISION OF IRON/ ALUMINIUM GRILL DOOR AT AFCME AT SUBROTO PARK
2023_MES_586307_1
GE/SP/ TOKEN-82/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹99,500
Yes
30 Jun 2023
18 Mar 2023
21 Apr 2023
18 Mar 2023
14 Apr 2023
2 Apr 2023
Amount
Demolition of brick or stone boulder masnory, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facing, dressed stonework and percast concrete articles.
M&L for Brick work with subclass B bricks, staright or curved on plan exc 6.00 mtr mean redius, biult in 1:6 cement mortar. Complete all as specified and directed by Engr In Charge.
M&L for brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 Complete all as specified and directed by Engr In Charge.
Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed by Engr In Charge.
M & L for rendering 10mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of primer incl 3mm thick wall care putty on walls up to four storey height building complete and specified and as directed by engr-in -charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper, including repairing of pot holes and cracks with 3mm layer putty, up to four storey height building complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new previously untreated wall surfaces and applying two coats of exterior Apex/weather over 3mm thick wall care putty up to four storey height building complete and all as specified and directed by engr-in-charge.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coats of exterior Apex/weather coat over 3mm thick wall care putty up to four storey height building complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling up to four storey height building complete and all as specified and directed by engr-in -charge.
M & L for preparation of old plastered surface and applying two coats of white wash on ceiling up to four storey height buildingcomplete and all as specified and directed by Engr-in -Charge.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L for two coats of synthetic enamel paint including prepration of wooden surfaces up to four storey height building complete all as specified and directed by Engr In Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
All as per item sr no.16 but not exc 1.5 sqm.
S&F aluminium frame powder coated any colour (minimum thickness of powder coating 50 micron) for doors, windows, partician, ventilators with one or more rebates including joining cleat for fixing etc. including taking down each chowkhats or frames with shutters (without taking off shutters from the frames) complete all as specified.
S&F aluminium powder coated an (minimum thickness of powder coating 50 micron) as in window and ventilator shutters, sliding type three track, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber packing, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engr-In-Charge.
S&F for powder coated aluminium doors shutters,( thickness of powder coating not less than 50 micron) alumonium section weighing 0.55 kg/m incl necessary joining cleats, glazing clips, rubber neoprene packing , handels 2 Nos in each door , hinges, anodised aluminium snap beading screws etc. complete all aspecified and directed by engr-In-Charge.
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.omplete all as specified and directed by Engr-in-Charge.
S & F in repair aluminium extruded section door closer hydraulically operated designation No-03, universal type, suitable for door shutters of 851 to 1000mm width and of weight of 61 to 80 Kg complete all as specified and directed by Engr In Charge.
S & F in repair 140mm long floor door stopper of brass body and tongue with hard drawn steel spring complete all as specified and directed by Engr In Charge.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification and directed by Engr In Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed by Engr In Charge.
S&F in repair 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed by engr-in -charge.
S&F in repairs 150mm long aluminium handle cast type polished bright complete and specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight stainless steel and fixed complete and specified and directed by engr-in-charge.
Supply only liquid water proofing compound only complete all as specified and directed by Engr In Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.complete all as specified and directed by Engr In Charge.
M&L for glazed ceramic coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 complete all as specified and directed by Engr In Charge.
M&L for vitrified Ceramic tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) over 100mm thick plain cement concrete, type D-2, 1:4:8, complete all as specified and directed by Engr In Charge.
All as item no.34 above but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed by Engr In Charge.
M&L for non skid ceramic joint free coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.11 Sqm but n. exc 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM(1:6) complete all as specified and directed by Engneer-in-Charge.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors including taking down complete all as specified and directed by Engineer-in-charge.
All as per item no.37 above but 20mm bore
Dismantling water tanks exc 500 litres but not exc 1000 Litres, and removing to store complete all as specified and as directed by the Engineer-in-Charge
S&F rotational moulded polyethylene 1000 Ltr water storage tanks triple layers as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings complete all as specified and as directed by Engr-in-Charge.
S &F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for 75 mm dia pvc pipe Stack clamps out of 50 mm x 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F in repairs for 100/110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item no.47 But 75 mm dia.
S&F in repair PVC SWR Junction piece 75 mm double (Double T) provided with access door equal or unequal complete all as specified and directed by Engr In Charge.
S&F in repair 100/110 mm PVC SWR Junction single (Single T) provided with access door complete all as specified and directed by Engr In Charge.
S7F in repair PVC SWR vent cowl of size 100/110 mm complete all as specified and directed by Engr-in-Charge
S&F in repair PVC SWR vent cowl of size 75mm complete all as specified and directed by Engr-in-Charge
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 100mm dia connection to trap , anti-syphonage complete all as specified and directed by Engineer-in-charge.
Supplying and fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S&F in repairs one piece wall mounted vitreous china wash down water closet pan, white (including fixing bolts, Push cock flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe. Plastic water closet seat black/white closed pattern with flat bottom jet spray with necessary fixing and cover and mild steel chromium plated or aluminised hinging device etc complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed by Engr In Charge.
S&F in repairs10 ltr capacity PVC flushing cistern coloured with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete and specified and directed by engr-in -charge.
S&F in repairs for 125 mm dia Steenless steel grating doom with waste hole for waste pipe (minimum weight 40 gram) complete all as specified and directed by Engr-in-Charge.
S&F in repair gun metal globe valve or gate valve with mild steel iron wheel head, screwed both ends for iron pipe & fitted for 20 mm bore complete all as specified and directed by Engr In Charge.
S/F in repairs 15 mm Stop valves,fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as per specified and directed by Engr-in-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc Complete all as specified and directed by Engr In Charge.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cemen complete all as specified and directed by Engr In Charge.t
M & L in repairs for 15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed by Engr In Charge.
S&F in repairs soap dish, Steelness steel approximate size 160x160x90mm fixed to plugs with chromium plated brass screws etc complete all as specified and directed by Engr In Charge.
S&F in repairs glass shelf corner consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engr In Charge.
S&F in repairs 15mm dia PVC Connection 450 mm long with nuts complete all as specified and directed by Engr-in-Charge.
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting with padestal and CP brass pillar cock complete all as specified and directed by Engr In Charge.
M &L for removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 1 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and as directed.
Material and labour for false ceilings using GI sanp grid system with rool-formed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceilimg board, prepainted cement fibre board size 595x595x4mm thick any texture (Lake, Hill, ocean cascade or Electra ) as approved by GE all as per. Everest Ceiling grid system 'Regular T-2430 or its equivalent Make of "Ramco/Charminar/Armstrong" at any height including dismatling complete all as specified and as directed by Engr-in-Chrage.
S & F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal aginst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screw, pointing around urinal back in cement, fixing brackets, waste pipe with coupling, gratting and Union for discharge pipe.
S&F in repair brass body mortice lock, vertical type,size 100 mm 4 lever, incl escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S&F in rapair for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks exc 1000 litres but not exc 2000 Litres, and removing to store complete all as specified and as directed by the Engineer-in-Charge
S&F rotational moulded polyethylene 2000 Ltr capacity tripple layer (white colour) (cylindrical vertical with closed top) hoisted and fixed as specified in SSR Part-I complete all as directed at site.
M&L for 40mm thick PCC 1:2:4 type B-1 using 20mm graded aggregate as in flooring, finished even and smooth with using extra cement complete all as specified
M&L for kota stone slab flooring 20-25 mm thick over cement screed bed and jointed with grey slurry mixed with pigment to match the slab including rubbing and polishing complete including cement scredd bed 15mm thick in cm 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr In Charge.
All as above item No-80 but as on vertical surface of wall such as skirting/dado incl 10mm thick cement plaster (1:4) as in backing coat of Kota stone complete all as specified and directed
M & L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection laid to slop of 1:12 finished surface even and fair without using extra cement with and including all necessary aform work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed by Engr In Charge.
M & L for complete removal of existing roof treatment with mud faska including bedding layer and disposed from MOD Land complete all as specified and directed by Engr In Charge.
M & L 15 mm thick screed bed or bedding layer of cement mortar (1:4), with liquid water proofing compound complete all as specified and directed by Engr In Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid 40 mm avg thickness as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge.
M&L for PCC Type B-2 (1:2:4) using 40mm graded stone aggregate) as in man hole, surface channel and drain complete including finished surface complete all as specified and directed by Engr In Charge.
M&L for forming fair finished drain or channel 30mm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etccomplete all as specified and directed by Engr In Charge.
S & F mild steel framed works such as grills, gratings etc with end of bars shouldered and/ or riveted or forged into spikers, frame guard bar, barred iron doors, ladders framed balusters, walk way, railing, iron gate with all connecting items with frame fittings in wall, frame work of water tank and single work conforming to E-165 (Fe-290) making good complete all as specified and directed.
M&L for preparation of untreated new steel surface exc. 10cm width or girth of any description and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc primer complete all as specified and directed.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling conduit wiring on ceiling /wall terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 Sq mm cable including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size for one light/fan/bell point controlled by one switch.
All as per item No-91 above but one exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No-91 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 91 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site.
S&F in repairs wall mounting fan 400mm platina sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
M & L in replacement submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified Note- 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable as earthwire incld PVC conduit shall be measured as one unit length.
M & L in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - Note- 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable as earthwire incld PVC conduit shall be measured as one unit length. considered for AC point)
Supply and fixing in repairs load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing comlete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below groundlevel) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Notes :- (i) GI strip connecting upto test point is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto test point.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets and light fittings etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement fan regulator step type 120 watt, 240 volt complete.
Supply and fixing in repairs LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing in repairs LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Taking down fan, cealing cable end,dismantling blades and removing fan and blades to deposite in MES store nd directed at site complete all as specified and directed by Engineer-in-Charge.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge.
Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed by Engr-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250MM and directed at site complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN 40 to 63 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
SM CONSTRUCTION COMPANY
Rishi Constructions
OMVIN ENTERPRISES LLP
Ashish Sehgal and Co.
J D ENTERPRISES
Hindustan Co.Co
shakti construction
Commercial Traders
JAIPAL AND BROTHERS
Mahesh Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .