Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹60,300
Closing Date
6 Jun 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room No.61, LESA Bhawan Near Residency Park, Kaiserbagh, Lucknow.- 226018
60/EUCC-V/LESA/2023-24
2024_MVVNL_920779_1
60/EUCC-V/LESA/2023-24
Open Tender
Electrical Works
Fixed-rate
60 days
33/11 kv s/s Gopramau
As per tender specification
2 documents required · 2 mandatory
₹3,540
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹60,300
15 Jul 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
33 KV VCB 800 Amp.
33 KV Control Pannel double Transformer
33 KV Control pannel single Feeder
33 KV Lightening Arrester 400 Amp.
33 KV Line Isolator
33 KV Bus Isolator
33KV Current Transformer 200/100/1
33KV Current Transformer 400/200/1
11 KV Incoming VCB 600/300/5A
11 KV Out going VCB 200/100/5A
11 KV VCB Bus coupler
ACSR Panther Conductor for Bus Bar
Disc Insulator B/S 70 KN
Disc Fitting 70 KN
11 KV 3x300mm2 XLPE Cable
11 KV 3x185mm2 XLPE Cable
11 KV 3x70mm2 XLPE cable
11 KV 3x300mm2 Outdoor Termination Kit
11 KV 3x300mm2 Indoor Termination Kit
11 KV 3x185mm2 Outdoor Termination Kit
11 KV 3x185mm2 Indoor Termination Kit
11 KV 3x70mm2 Termination Kit outdoor
11 KV 3x70mm2 Termination Kit indoor
Cost of 11/0.4 KV Transformer 63 KVA
LT Armourd cable 3.5x70 mm2
ST pole 11 mtr long
M.S.channel 100x50 sq mm
M.S.Angle 65x65x6 sq mm
11 kv pin insulator
M S Earthing Rod 20x2500 mm
11 kv pin with nut
1x240 LT XLPE Cable
Top channel 100x50mm
11 KV Pin insulator
MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge [email protected] Kg./M
MS Round of 32mm dia for making MS earth electrode 32x3000mm. [email protected] Kg./M
ST pole 9 mtr long
Rail 105 lb 9 mtr long
M.S. Angle 65x65x6 mm
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
M.S Angle 50x50x6 mm
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
MS Angle 75x75x6 2.6M long 2 Nos. [email protected] Kg./M
Earthing of substation Switchyard.
Checking of soil resistivity of S/S land and if required take necessary measure to make soil resistivity as per norms.
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
Painting of all structures equipment.
Erection of 33 KV Bus Bar Gantary complete with structure.
Stringing, sagging, jumpering of bus bar gantry with ACSR panther conductor 3Phase 3wire.
Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Erection of structures, grouting, plinthing of ALL structures equipment.
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
33 KV VCB
33 KV lightning Arrestors
Bus/Line Isolator
Fabrication & Erection of Neutral Stand structure with foundation
Erection and commissioning of 5 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar & 33KV cable to T/F (with copper L piece) complete work.(01 no. T/F bay)
Jumpering complete 33 KV Line bay with ACSR panther Cond. and required clamp with nut & Bolts from Incoming 33KV Feeder to Bus bar gantry.(01 no complete 33 KV bay)
Laying of double circuit 11 KV 3x300 sq mm XLPE cable in normal soil by digging of suitable size of trench as per site condition cable should be covered by bricks and sand.
Laying of double circuit 11 KV 3x300 sq mm XLPE cable in Existing trech.
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panel with proper taping with the help of empire tape. PVC tape and connectors.
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Supply & Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system.
Copper Control Cable 2x2.5 Sq. mm.
Copper Control Cable 4x2.5 Sq. mm.
Copper Control Cable 6x2.5 Sq. mm.
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
33 KV Double T/F Control panel
11 KV Incoming VCB 600/300/5A
11 KV Out going VCB 200/100/5A
11 KV VCB Bus coupler, 350 MVA
Erection of S/S Type Double Pole for 63 KV S/S T/F
Laying of double circuit 11KV 3x70 sq mm XLPE cable in cable trench with proper ferrurling. Cable trench should filled by fine sand.
Laying of LT cable of size 3.5x70 sq mm in between station T/F and distribution switch in the room and its proper lugging, connecting and tapping etc.
Supply and fixing LT distribution panel for lighning of control room,switch yard and substation building the panel contaaining 1 no 63 amp MCCB and 5 no Outgoing MCB's for substaion buliding, yard lighting,AC and DC supply of panels etc.
Fabrication, erection, grouting, plinthing and painting of ST pole 9 M long as RESPO norms and mounting of LED lamp 120 watt complete work . (All material expert Pole ,shall be provided by the contracter)
Supply and installation of fire extinguisher Co2 type 4.5 Kg at suitable place as per RESPO Norms
Supply and Erection of 24 V batteries set with charger including stand (stand shall be provided by contractor) & initial charging complete set.
Grouting,Plinthing and Painting of new erected 11M long ST poles of single pole support,double pole cable exposures
Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST Pole and refilling with ramming of earth.
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M & balance by two coats of best quality aluminium paint ISI of Burger/Nerolac/Asian mark as per norms.
Earthing of 11 mtr, 9 mtr ST pole with MS earthing rod 20Х2500 mm
Fabrication & erection of 11 KV D/C cable exposure type double pole with the provission of cable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms.
Hoisting of 11KV 3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
Laying of single circuit 11KV 3x185 sq mm XLPE cable in normal soil by digging of suitable size of trench as per site condition cable should be covered by bricks and sand.
Hoisting, jumpering, clamping of 11KV 3x185 sq mm XLPE cable on 11 KV panels with proper taping with the help of empire tape. PVC tape and connectors.
Sand filling in cable trench with fine sand after laying of 11 KV cables (Fine sand should be provided by the contracter)
Construction of Toe wall around the outdoor Switchyard of the S/S of size 0.75x0.25 Mt.At Base and 0.25 Mt. At top as per RESSPO Norms by lst class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio1:6:12 and plaster 12 mm thick in ratio 1:4.
Fabrication of switchyard fencing with wiremesh10 SWG (37mmx50mm) as per drawing along with Fabrication of one number gate made of MS Angle, MS Channel, MS Flat together with locking arrangement, its Installation including the cost of civil material, angle 50x50x6mm, Channel Etc .
Interlinking Tiles wide complete work including material and labour with Providing grovel in (20 mm stone ballast) in Swithchyard area.
Complete work of fixing of inertlocking tils in swithchyard area. (All the materials shall be provided by contracter)
Provideing gravels (20 mm stone ballast) in swithcyard upto 15 cm hight form the graund level.
Provide bucket with bucket stand as per norms (3nos bucket for sand & 3 nos bucket for water in one set.)
Construction of RCC cable trench 800x850mm as per drawing including trench Cover in Angle fram. Size of angle 75x75x6 mm trench wall thikness 1500mm grill by MS rod 10 mm dia vartical distance 6" Horizatel distance 4"
High pressure testing
Supply of following auxiliary material
Office table ( 1200x750x600 mm) with sunmica top and one drawer
Wooden Armed Chair
Sitting Bench
Line Chart Board
Rubber mat 2Х1.5 mtr
Steel Almirah
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .