| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹49.0 L+₹3.1 L (6.69%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹50.5 L+₹4.5 L (9.83%)Rejected-Finance | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹52.7 L+₹6.8 L (14.7%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹74.5 L+₹28.6 L (62.2%)Rejected-Finance | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
7 Oct 2024, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF WATER SUPPLY NETWORK PUMP MOTOR CLORINATION PLANT AND OTHER CONNECTED ITEMS AT CQAE WE UNDER GE M AF JALAHALLI
2024_MES_670864_1
8923/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
25 Oct 2024
3 Sept 2024
9 Oct 2024
3 Sept 2024
7 Oct 2024
17 Sept 2024
3 Sept 2024 - 10 Sept 2024
Amount
Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500.00 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other than the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 25HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 25HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only suitable size of gland packing for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only gun metal bush as per existing suitable for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only rubber coupling as per existing suitable for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only impeller as per existing incl lathe work required for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only motor fan blade as per existing for 25 HP motor as per manufacturer's design complete all as specified and as directed.
Taking down defective centrifugal pump set 20 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Make of Pump : Kirloskar Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500.00 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling bolt with nuts suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling Rubber Bush suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 20HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only suitable size of gland packing in 20 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only gun metal bush as per existing suitable for 20 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only for rubber coupling as per existing suitable for 20 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only impeller as per existing incl lathe work required for 20 HP pump set as per manufacturer's design complete all as specified and as directed.
Supply only motor fan blade as per existing for 20 HP motor as per manufacturer's design complete all as specified and as directed.
Material and labour for removing the submersible pump set of capacity up to 15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual.vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting to Work shop and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed
Material and labour for repair/overhauling of submersible pump set up to 15 HP capacity of, and any stage by replacing bushes, impeller thrust bearings, strainer, nuts and bolts, washers, pump shaft remetalling, grinding, polishing complete reassembling the pump winding the motor and testing, including painting with two coats of synthetic enamel paint after preparing the surface complete all as specified and directed.
Material and labour for repairs of star delta starter of pump set 25 HP by replacing over load relay of suitable current rating,timer relay ,single phase preventor , spare kit contacts for contactor, terminals, short pieces of copper wire duly crimped with bottle lugs etc. and any other spares as required for proper functioning and monitoring of pump set all as specified and directed.
Dismantling, Rewinding of 25HP centrifugal motor, with suitable size of copper enamelled winding wire and insulating materials, varnishing of pump set, bushes and any other parts require for proper functioning and re-assembling, connecting and testing complete all as specified and directed .
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site 50 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 25 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 20 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 15 mm bore complete all as specified directed.
Taking down and relaying of existing DI water pipe lines of size 150 mm bore but of any type includings all fittings after removal of scalling, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 100 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked conforming to IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel capacity of, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
S&F in replacement foot valve cast iron of size 100 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Supply and fixing in replacement Sluice valve of size 80mm dia Cl body, both ends flanged duly drilled, ISI marked conforming to IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel capacity of, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
Supply and fixing in replacement Non return valve (NRV) of size 80 mm (ISI marked), gun metal body suitable for 80mm dia pipe line complete all specified and directed
Supply, install, testing and commissioning of Chemical Dosing system having top dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 - 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall along with dosing Injector of the following specification. Adjustable dosing pump max pressure 5kg/cm square & max flow rate 0 - 50 ltr / hr including all accessories such as Lead tubing, Connecting Ferrules, check valves, non return valve all as directed. Power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, etc complete all as specified and directed. Make: - Model No. VST 1011 of Ravi Enterprise or equivalent as per E-in-Cs make approved. Note: Unit quoted rate shall be inclusive of taking down of old unserviceable plant and depositing same to MES store yard .
Supply and Fixing as in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 KA, 50 Hz, AC, adjustable thermal and magnetic type in the existing pump starter panel including connecting up incoming/out going cable with suitable lugs and testing complete all as specified and as directed. Make : Legrand/Indo asian/L&T
Supply and fixing in replacement of fully automatic star-Delta submersible pump starter suitable for 15.0 HP submersible pump with OL relay , Single phase preventer , indicating lamps , push switch, enclosure including all connected accessories complete all as specified and directed.
Supply and Fixing as in replacement Single phase preventer for motor in the existing panel board with new one at water supply installations and taking down old unserviceable items all as specified and as directed.
Clearing the bushes trunk girth not exceeding 10 .00 cm and area around valve chambers upto 1.0 mtrs and depositing at a distance not exceeding 50 mtrs from starting point complete all as specified and directed
Supply & Fix as in replacement of GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed
Supply and Fixing as in replacement of 3 Pole power contactor AC 415 V, 32 Amp, AC3, (inductive load) type with Aux contact 2 NO + 2C 50 Hz Model No as per existing frame suitable for 20 to 25 HP Pump set all as specified and directed. Make : L&T/Indoasian/Schenider/Havells
Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed. Note:The material should be delivered at watersupply installation as per direction of AGE E/M as & when required during the contract period.
Supply Only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed
Dismantling, Rewinding of 20 HP centrifugal motor, with suitable size of copper enamelled winding wire and insulating materials, varnishing of pump set, bushes and any other parts require for proper functioning and re-assembling, connecting and testing complete all as specified and directed .
Material and labour for repairs to unserviceable star delta starter of pump set 20 HP by replacing over load relay of suitable current rating,timer relay ,single phase preventor , spare kit contacts for contactor, terminals, short pieces of copper wire duly crimped with bottle lugs etc. and any other spares as required for proper functioning and monitoring of pump set all as specified and directed.
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of Grase etc complete all as specified and directed. Note :- DI fitting/special will be measured and paid separately. Note: Excavation & earthwork shall be measured & paid seperately
M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains branches lines such as bends(any type radius and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee pieces,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth pieces suitable for rubber joint,tyton joint up to 150 mm bore and conforming to IS-9523: 2000 complete all as specified and directed
Material and Labour for Cutting DI pipes in position for insertion of new tees and socket of size 150 mm dia Complete all as specified and as directed.
Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked confirming to IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel , fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) as in Coping, bands benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work Complete all as specified and directed.
Material & Labour as in repair for Construction of valve pit having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
Material and Labour for dismantling the brass splindle from 150mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for dismantling the brass splindle from 100mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for dismantling the brass splindle from 80mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material & Labour as in repair for Construction of valve pit having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
Material and Labour for gland packing in leaking Sluice Valves of 80 mm dia size complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Supply and fix replacement of U/S leather packing suitable for foot valve 80 to 100 mm dia, suction pipe flanged connected to pumpsets including replacement of U/S nuts and bolts etc all as specified and directed
Supply & Fix as in replacement of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed.
S & F in replacement Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mm for brass ferrule fancy type and fixed complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed.
Chemical and physical analysis of water confirming to IS 3025 - 58 (2006) second revision of various locations at CQAE (WE) Area from any lab authorised by central/state govt for chemical analysis. The following test shall be carried out :- (a) Bacteriological Quality of water (ref Table 6, Clause 4.1.1, IS 105000 : 2012 second revision) (b) General Parameters Concerning Substances of water (ref Table 2, Clause 4.0, IS 10500 : 2012 second revision) (c) Organoleptic and Physical Parameters of water (ref Table 1, Clause 4.0, IS 10500 : 2012 second revision) Note : Contractor shall collect the water sample and subbmit the test result to Engr-in-Charge as specified and directed.
Supply and fixing in replacement butterfly valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel , fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Supply and fixing in repair of 3 phase star delta pump starter suitable for 25 HP centrifugal pump with over load relay of suitable current rating,timer relay ,single phase preventor fixing in existing enclosure including all connected accessories complete all as specified and directed Make : L&T/Indoasian/Schenider/Havells
Supply and Fixing as in replacement 3 Pole power contactor AC 415 V, 25 Amps, AC3, (inductive load) type with Aux contact 2 NO + 2C 50 Hz Model No. as per existing frame suitable for 20 to 25 HP Pump set. Make : L&T/Indoasian/Schenider/Havells
Supply and Fixing as in replacement Star Delta timer 0-30/60 sec all as specified and directed.
Supply and Fixing as in replacement MCCB, 3 pole 415 Volts, 63 Amps, 16 KA, 50 Hz, AC, adjustable thermal and magnetic type in the existing pump starter panel including connecting up incoming/out going cable with suitable lugs and testing complete all as specified and as directed. Make : Legrand/Indo Asian/ L&T
S & F as in replacement ON load change over switch 4 pole 125 Amps in sheet metal enclosure complete all as specified and as directed . make :- Havells /L&T/Indo Asian
Supply and fixing in replacement of air release valve of size 40 mm dia Cl body, ISI marked of IS 14845 of 1.6 PN including with fixing arrangement of existing 150 mm dia DI pipe line with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
Supply and fixing Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 for fabrication of valve pit chamber, raising main support and motor foundation supports etc all as specified and directed.
Material and labour for Fabricate supply and fix valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted cover all as directed.
Material and labour for Painting with two coats of synthetic enamel paint over coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described all as specified and directed.
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in in cement mortor 1 : 4, complete, in walls all as specified and directed.
Material and labour for attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessary engineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed.
Note :- (a) The contractor has to attend above mentioned job in any location of entire CQAE (WE) Area
(b) The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.
(c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.
(f) In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) If the delay is more than 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(h) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fix water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks three layer, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing tank of any description and any capacity .Make :- Sintex or equivalent approved make.
Supply and fix in replacements lids for polythylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed suitable for upto 500 Ltrs cap of tanks.
Supply and fix in replacement Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm bore complete all as specified and directed
Supply and fix in replacement Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm bore complete all as specified and directed
Supply and fix water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks three layer, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing tank of any description and any capacity .Make :- Sintex or equivalent approved make.
Supply and fix in replacements lids for polythylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed suitable for upto 1000 Ltrs cap of tanks.
Supply and fix in replacement Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 meter and depositing where directed at a level not ecx 1.50m above the starting point complete all as specified and directed .
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
M & L for Bricks covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD. (iv) Laying of any type/any bore of pipe in trenches including taking down. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Material and labour in repair for 3 ½ core 185 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprisisng of the following:--
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 02 Nos(O/G). (c) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with theromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 02 No(O/G). (c) MCB TPN of 415 V of capacity 40 Amps 10 KA - 01 No (O/G) (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply and fix for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection fixed to the pole wall etc along with suitable fittings for cable protection all as specified and directe
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Material and labour in repair for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make:- Havells/ Polycab/ RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 150 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 01 No(O/G). (c) MCB TPN of 415 V of capacity 40 Amps 10 KA - 01 No.(O/G) (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No.(O/G) (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 Amp by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end ( copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, complete including taking down, old u/s pit cover complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Material and labour as in repair for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Square bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 250X300X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black back ground with white and complete all as specified and as directed.
Supply and fixing as in repair for alluminium earth continuity conductor or main earthing lead fixed to wall / roof top for lightning arrester fixed to OHT or other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, aluminium using porcelain clit/post insulators with screw / self dril GI screw with rubber washer , complete all as specified and directed.
M&L flat three core PVC Insulated & PVC sheathed industrial cable for submersible Pump Motors 1100 Volt, conforming to IS 694, 6 .0 Sq mm nominal area complete including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex
Supply and fixing as in repair solar aviation obstruction light base on LED technology intebcity less then 10 CD (Flashing), Horizontal divergence 360 Degree , flash setting 20-60 times/min (user-adjustable) , on off level 70/100 lux , internal battery capacity 3.6/10 AH (maintenance -free) , IP protection IP 65 , visible distance less than 3.6 KM ,Base material dia casting aluminium LM6 and lamp housing polycarbonate with UV resistance and bird spike complete fixing arrangement of like base plate as top fixing or side fixing with stainless nut and bolts complete all as specified and directed of make :- Micolux or equivelent
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No(O/G). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 01 No(O/G). (d) MCB SPN of 415 V of capacity 40 Amps 10 KA - 02 Nos (O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS). Note :- An amount of Rs 100180.000 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
PLATINUM CONSTRUCTIONS (BID ID -3129970)
JM Engineering (BID ID -3110105)
ANAND REFRIGERATION (BID ID -3129171)
RMK PROJECTS (BID ID -3131734)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .