Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC OFFICE E2 MANALI ARCADE NEAR D MART PADMAVATI PUNE SATARA ROAD PUNE MAHARASHTRA 411009 PUNE MAHARASHTRA 411009 | PUNE | MAHARASHTRA | 411009 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹6.9 L+₹2.5 L (56.9%)Rejected-Finance 2 3 AMIT VIJAY APARTMENT KASTURBA CROSS ROAD KANDIVALI W MUMBAI 67 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | Rejected-Technical 115 B K PAUL AVENUE 115 B K PAUL AVENUE KMC WARD NO 19 KOLKATA BANKURA WEST BENGAL 700005 INDIA | KOLKATA | WEST BENGAL | 700005 | - | Rejected-Technical Not Recommended | |
| 4 | Rejected-Technical 196 GOREGAON W MUMBAI MAHARASHTRA 400062 | 400062 | - | Rejected-Technical Not Recommended | |
| 5 | Rejected-Technical 33 RUSHIKESH INGOLE NAGAR MODERN CO OPERATIVE HOUSING SOCIETY WARDHA ROAD NAGPUR MS 440 005 | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | - | Rejected-Technical Not Recommended |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
31 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BAGDOGRA
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
PROVN OF CONDUCTING NECESSARY TEST TO ASCERTAINING THE STRUCTURAL STABILITY OF OVER HEAD TANKS UNDER GE (AF) BAGDOGRA
2023_MES_572884_1
8459/E8
Open Tender
Civil Works
Item Rate
150 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹20,000
Yes
31 Mar 2023
3 Jan 2023
2 Feb 2023
3 Jan 2023
31 Jan 2023
17 Jan 2023
Amount
Carrying out detailed Visual observation of water tank/Reservoir or pump houses & control room for distress like cracks, rust, staining, spalling, leakages, seepages, corrosion distress etc. Inspection would be documented in the form of worksheets, photographic records and distress over drawings etc to assess current state of condition levels of deterioration, stability/durability etc complete all as specified and directed.
Ultrasonic Pulse Velocity Test for ascertaining the quality of soundness of concrete as well as uniformity of concrete in terms of density, crack, depth and width casual analysis of crack propagation as per IS 13311(part -1) : 1992 ASTM C597-02, BS 6089:1981 complete all as specified and as directed.
Rebound Hammer test for determining the estimated compressive strength of concrete and uniformity of concrete in terms of surface hardness as per IS 13311(part-2)-1992, ASTM C 805-02, BS 6089: 1981 and BS 1881:part 202, BSEN : 13791, also establishing correlation chart between rebound hammer and other confirmatory test for estimated in-situ strength of concrete complete all as specified and as directed.
Measuring the Half Cell Potential readings with wheel electrode at the nodes of pre-marked grip points on concrete surface in as suitable grip for determining the probability of corrosion activity of embedded steel reinforcement in concrete with specified half cell electrode in accordance with ASTM C876-1980 complete all as specified and as directed.
Resistivity Meter Test is used to determination of estimation of likeyhood of corrosion. Indication of corrosion rate, correlation to chloride permeability, determination of Zonal requirement for cathodic protection systems, identification of areas within a structure most susceptible to chloride penetration systems, identification of areas within a structure most susceptible to chloride penetration as per BS EN 12696:2000, RILEM TC-154, AASHTO T277 RCP, AASHTO T259, ASTM C 1202 97 complete all as specified and as directed.
Water Soluble Chloride Content % (by of mass of concrete) to check the risk of corrosion due to present chloride % as per IS:14959 (part 2)-2001, BS 5328 part 1, ACI 201, 2R-92, BS 1881 Part 124: 1988, BS 8110, IS 456:2000 complete all as specified and as directed.
Rebar Scanning/Profile Mapping of RCC Member by using Ferro Scanner for detecting Reinforcement. Location, Numbers/ Spacing of Rebars in RCC Structural member of existing structure (Accuracy subject to site condition) complete all as specified and as directed.
Structural Analysis (Push Over-Non Linear Analysis) by preparation of structural 3D model of the building using software as per data obtained from site measurements & non destructive testings. Current loads subjected are applied over structural model while performing analysis. Health assessment/condition assessment were derived from analysis results complete all as specified and as directed.
Preparation of structural Audit Report which includes: (a) the findings from detailed Visual Inspection in the form of Observations, Photographic Records and critical Areas. (b) Non destructive test results & their interpretation to assess current state of condition & level of deterioration. (c) Suggested econoical Viable remedial measures to restore structural stability and increase durability/residual life of building water tanks etc complete all as specified and as directed.
Consultancy for Estimation & costing of suggested retrofitting Work. Includes Tentative measurement, prepare Methodology (Short Specification) of suggested Repair Works, providing BOQ as per Government SSR rates complete all as specified and as directed.
B J MEHTA ARCHITECTURAL AND STRUCTURAL CONSULTANTS PVT.LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .