Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹19.2 L+₹1.2 L (6.93%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance Not being L1 Bidder | |
| 3 | L3₹21.0 L+₹3.0 L (16.5%)Rejected-Finance HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Not being L1 Bidder | |
| 4 | L4₹21.6 L+₹3.6 L (20.0%)Rejected-Finance | L4 | Rejected-Finance Not being L1 Bidder | |
| 5 | L5₹24.7 L+₹6.7 L (37.0%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
5 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SOUTH UDHAMPUR
GARRISON ENGINEER SOUTH UDHAMPUR
REPAIR TO BDY WALL DRAIN PATH AND CLEANING OF SEWAGE LINE AND OTHER MISC WORK IN MD ACCN OF BIKRAM ENCLAVE IFA NODE AOR OF AGE BR II AND PERIODICAL SERVICES AND WELCOME MAINT AT BIKRAM ENCLAVE IFA NC AND NODE UNDER AGE BRII GE SOUTH UDHAMPUR
2024_MES_658318_1
GE/S(U)- /2024-25
Open Tender
Civil Works
Works
270 days
GE SOUTH UDHAMPUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹88,000
4 Oct 2024
7 Jun 2024
6 Jul 2024
7 Jun 2024
5 Jul 2024
21 Jun 2024
Amount
Desluding/Dewatering of septictank/ soakage wells/drain including intel/outlet chambers removing out all scum, siltresiduals sludge (both) organic/ inorganic nature) after plugging the incomming sewage lines through combined high pressure water jetting cum suction (vaccum) type machine mounted on LCV/HCV facility of high pressure vaccum and removing the same in the tank to a place outside MOD load meant for the purpose by local municipality complete all as specified and as directed by Engr-in-Charge or Garrison Engineer.
Removal of blockage and cleaning of sewage lines of 100 mm bore by roding from manholes to manholes or manholes to cleaning eyes, taking out all debris, sludges and solid materials from sewage lines and removing out side MoD land not less than 1000 metres and well flushing with water complete all as specified and directed.
All as per ser item No 2 but 150 mm bore complete all as specified and directed.
All as per ser item No 2 but 200 mm bore complete all as specified and directed.
Cleaning of cast iron pipes 100mm/75mm bore pipes by roddimg with jute bags and well flushing after cleaning complete all as spfd and directed
Cleaning of man holes n.exc 1.5m deep and removing sludge/waste material to distance n.exc 500m and burying in pits and refilling the same complete all as spfd and directed by Engg-in charge or Garrison Engineer.
All as per ser item No 06 but exceeding 1.5m deep and 3.0m deep complete all as specified and as directed
Cleaning of floor traps and removing waste material etc to a distance not exceeding 50 m and burring in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge/ Garrison Engineer.
Removal of blockage/waste and cleaning gully traps and Nahani traps of any description and size and waste material etc to a distance not exceeding 50 m and burrying in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge/ Garrison Engineer.
Cleaning of blocked WC any type and removing waste material etc to a distance not exceeding 50m and burring in pits and re-filling the same complete all as specified and directed by the Engr-in-Charge/ Garrison Engineer.
Cleaning of shurbs/ bushes around septic tank, ,filter bed,manholes and along the sewage line etc complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5 m deep and getting out in any type of soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well ramming in layers n exc 25cm thickness complete all as specified and as directed.
Removing excavated soil to a distance n exc 50m and depositing at alevel n exc 1.5m above the starting point complete all as specified and as directed.
Demolition of cement concrete in ground floor and pavings nexc 15 cm thick below or above ground level complete all as specified and as directed.
PCC type D2(1:4:8) using 40mm graded crushed aggregate as mass conc and filling of foundation complete all as specified and as directed.
Demolition and breaking up drain pipes 100 mm dia ( Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes 150 mm dia ( Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes 200 mm dia ( Salt glazed ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed.
Salt glazed stone ware drain pipe 100mm bore in trenches and jointed complete all as specified and as directed.
Salt glazed stone ware drain pipe 150mm bore in trenches and jointed complete all as specified and as directed.
Salt glazed stone ware drain pipe 200mm bore in trenches and jointed complete all as specified and as directed.
Concrete 1:4:8 type C2 using 40mm graded aggregateas in bed to 100mm drain pies incl packing under and haunching against the sides pipesafter they are laid and tested complete all as specified and as directed.
Concrete 1:4:8 type D2 using 40mm graded aggregateas in bed to 150mm drain pies incl packing under and haunching against the sides pipesafter they are laid and tested complete all as specified and as directed.
Concrete 1:4:8 type D2 using 40mm graded aggregateas in bed to 200mm drain pies incl packing under and haunching against the sides pipesafter they are laid and tested for complete all as specified and as directed.
Plain cement conc 1:4:8 type D-2 using 40mm graded agg as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm bore pipes all as specified and as directed.
200mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and as directed.
300mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars complete all as specified and as directed.
Brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
Walling of random rubble masonary , recangular coursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and as directed.
Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in external surfaces of man holes, septic tank, filter bed etc incl removing of debrie complete all as specified and as directed.
Rendering 15mm thick on brick or concrete surfaces of walls in CM (1:4) including finishing the surfaces even and smooth without using extra cement as in manholes, septic tank, filter bed out let drain etc all as directed by Engineer-in-Charge/ Garrison Engineer.
Flush pointing to squared rubble masonry coursed or uncoursed in CM (1:3) complete all as specified and as directed.
PCC type B1(1:2:4) using 20 mm graded cushed stone agg as in coping ,benching and the like incl form work complete all as specified and as directed.
Demolition of renieforced cement concret not exeeding 15cm thickness (below or above ground level) complete all as specified and as directed.
Reinforced cement concrete type B-1 (using 20mm graded crushed stone graded aggregatework as in slabs supported on walls , beams etc all as specified and as directed.
RCC 1:2:4 type B1 using 20mm graded aggregates for precast cement conc slabs as in manhole covers etc set in cement mortar 1:4 complete all as specified and as directed.
Form work to soffits of suspended slabs and similar work not exceeding 200mm thick
Mild steel steel TMT bars 10mm dia and over cut to length bent to shape reqd ,incl cranking ,bending spirally for hooping columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia complete all as specified and as directed.
Cutting in to existing manholes (RCC/Brick) for forming new drains and making good to pipe and making good to pipe and rendering ,cutting out existing benching in cement conc 1:2:4 type B1(in 1/2 or 3/4 round in section)and reforming benching as reqd for 150mm/200mm bore pipe complete all as specified and as directed.
PVC(SWR) junction double,(Single T),equal or unequal. 110 mm dia complete all as specified and as directed.
PVC(SWR) junction double,(double T),equal or unequal. 110 mm dia with access door complete all as specified and as directed.
PVC (SWR) vent cowl 110 mm dia complete all as specified and directed.
CI floor trap with grating incl jointing to waste pipe with dia of outlet 75mm in repair complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required of internal dia of pipe 50/75/100 mm ccomplete all as specified and as directed.
Sand cast cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to wals bore of pipe 100mm dia complete all as specified and as directed.
Sand cast cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls bore of pipe 75mm dia complete all as specified and as directed.
CI bends diminishing pieces or tapers bore of pipe 100mm complete all as specified and as directed.
CI bends diminishing pieces or tapers bore of pipe 75mm complete all as specified and as directed.
CI branch pieces, single (equator unequal) ordinary or inverted (size or socket type) or with parallel branches with oval access door bore of pipe 100mm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
(300mm x 200mm) x 7 mm thick coloured glazed ceramic tiles as in skirting/dado set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
10 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:4 and finished even and fair complete all as specified and as directed.
Non skid coloured 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block (glossy finish)of approved shape and size confirming to IS 15658-2006 of 60mm thickness with grey cement and no pigment, M-35 Grade of approved colour and design complete all as specified and directed by Engr-in-Charge/ Garrison Engineer.
75 mm thick plain cement concrete type D-2 (1:4:8) (40 mm graded stone aggregates) as in sub base complete all as specified and directed.
Sand cushion 20 to 30mm thick for fixing of inter locking tiles complete all as specified and directed by Engr-in-Charge/ Garrison Engineer.
S&F in repair 10 ltr capacity PVC low level flushing cistern symphonic action type white with inlet valve float and handle including brackets, fixed in repairs complete all as specified and directed.
Flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed.
Vitreous China squatting pan, 'Orissa' pattern, size 580x 440 mm white, with integral foot rests including a provision of concrete bedding but fixed in repair complete all as specified and directed.
Cast iron 'P' or 'S' trap for bore of pipe 100mm complete all as specified and as directed.
Water proofing treatment to surfaces of walls/concrete slabs damaged due to moisture and efflorescence including sunken areas of bathrooms/toilets, in balconies by applying acrylic polymer modified cementitious high performance coating or treatment all as per manufacturer's instructions, complete all as specified and as directed.
PCC 1: 5 : 10 type E2 using 40 mm graded brick aggregate as in filling under sunken floors etc complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
15 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed.
10 mm thick rendering on fair faces of brick /concrete surfaces as in ceiling in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of old/painted wood or wood based surface of any description not other wise described over 10cm width or girth including knotting and stopping and applying one coat of synthetic enamel paint complete all as specified and as directed.
Preparation of old painted steel surface of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Applying one coat of oil bond distemper on walls including preparation and complete removal of existing treatment from old decorated plastered or unplastered surfaces of walls, tint and shade as approved by Engr-in-charge, complete all as specified and as directed.
Applying two coat of oil bond distemper on walls after preparation of newly plastered surfaces complete all as specified and as directed.
Applying two coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified and as directed.
Applying two coats of cement base paint after preparation of newly plastered surfaces complete all as specified and as directed.
Applying one coats of cement base paint after preparation of old plastered surfaces complete all as specified and as directed.
Applying one coat of white wash on old decorated plastered surfaces of ceiling after preparation of surfaces complete all as specified and as directed.
Applying one coat of white wash on old decorated plastered surfaces of walls after preparation of surfaces complete all as specified and as directed.
Applying 1mm thick layer of wall putty on walls to give uniform surface complete all as specified and as directed. NOTE:-(Before applying of wall care putty, Complete removing of treatment as directed and approved by Engr-in-charge/ Garrison Engineer)
Note :- For Periodical services. (i) Periodical services to be carried out up to 30' feet with scafolding and necessary safety precatution (Helmet, Seat belt & Jacket etc). (ii) During periodical services all material/floor/furniture etc covered with polythene/terpoline, Floor to be cleaned with water. (iii) If contractor fails to abid any above (i) to (ii) conditions, contractor will charged penalty Rs 500/- per day per complaints.
Note :- For repair to Bdy wall, Drain Path, cleaning of sewage line and other misc work. (i) Contractors/Contractor representative/ Engineer will report to Bikram complain cell/ concern JE daily in morning at 08:30 AM to collect complaint for routine/urgent works related to day to day maintenance till completion of contract. (ii) Contractor's representative for attending the complaints should be in proper uniform i.e. Blue shirt, Trouser, Cap, Safety Shoes and carry tool bag. (iii) Contractor has to handover 25% store in MES complaint cell/store on quarterly basis for daily complaints. (iv) If contractor fail any above (a) to (c) conditions, contractor will charged penaulty Rs 500/- per day per complaints.
M/S ASHOK KUMAR PACHIALA
khajuria builders
VISHWANATH AND SONS
SINGH CONST CO
sohtra and co
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .