| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹5.0 L+₹45,756 (10.1%)Rejected-Finance | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹5.4 L+₹90,100 (19.9%)Rejected-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹5.7 L+₹1.2 L (26.0%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹5.7 L+₹1.2 L (26.4%)Rejected-Finance | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹8.3 L
EMD Value
₹16,600
Closing Date
27 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) CIF (K)
AGE (I) CIF (K) Shalateng
REPAIR AND MAINTENANCE OF LT EXTERNAL ELECT WORKS AND PERIMETER LIGHTING, STREET LIGHTS AND OTHER CONNECTED WKS AT SECTOR B, C AND D AT HQ CIF (K) UNDER AGE (I) CIF (K)
2021_MES_426419_1
AGE (I) CIF (K)-39/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shalateng
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
AGE (I) CIF (K)
₹16,600
Yes
1 Apr 2021
27 Feb 2021
29 Mar 2021
27 Feb 2021
27 Mar 2021
13 Mar 2021
60 days
Amount
Dismantling and taking down HPSV/CFL street light fitting/LED security light fittings from the existing pole etc for repair and replacement at given site, complete all as specified and as directed by the Engineer-in-Charge.
New generation energy saving and environmental friendly long life LED street light, 40 watt, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with all accessories including connecting using suitable wire, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells CAT NO : ENDURAPEARLNEOSL40WLED 757PASYTOPC or equavalent in Philips/ Bajaj.
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, 70 watt, suitable for highlighting architectural facade and general purpose lighting complete with all accessories including connecting using suitable wire, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells cat no JETAPROFL70WLED757LTG or equavalent in philips/ Bajaj.
Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, 150 watt, suitable for highlighting architectural facade and general purpose lighting ,complete with all accessories including connecting using suitable wire, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells cat part No: JETAIRISFLS150WLED757 PSYMLTG or equavalent in Phillips/Bajaj
New generation energy saving and environmental friendly long life LED street light, 30 watt, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete with all accessories including connecting using suitable wire, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells cat part No: ENDURAPEARLSL30WLED 757SASYTOPCMP or equavalent in Phillips/Bajaj
New generation energy saving and environmental friendly long life LED street light, 70 watt, made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughned glass having IP66 protection and impact resistance of IK07 complete with all accessories including connecting using suitable wire, complete all as specified and as directed by the Engineer-in-Charge. Make:- Havells cat part No ENDURAPEARLSL70WLED 757SASYBOTG or equavalent in Phillips/Bajaj
Mild steel wall bracket of suitable size and length not more than 1.2 metre of GI tubing medium grade 32 mm dia for mounting of security light fittings with and including mounting on wall/pole with suitable size of clamps, nuts, bolts and washers, complete all as specified and as directed by the Engineer-in-Charge.
MCCB 4 pole 63 amp 440 volt 35 KA, complete all as specified and directed by the Engineer-in-Charge.
Supply and replacement of Driver for LED street light fittings of capacity 40/50 watt complete all as specified and as directed by the Engineer-in-Charge. Make - Bajaj/Havells/Surya/Philips/Crompton.
Supply and replacement of Driver for LED street light fittings of capacity 70 watt complete all as specified and as directed by the Engineer-in-Charge. Make - Bajaj/Havells/Surya/Philips/Crompton.
Supply and replacement of Driver for LED street light fittings of capacity 150 watt, complete all as specified and as directed by the Engineer-in-Charge. Make - Bajaj/Havells/Surya/Philips/Crompton.
Supply and fixing in replacement change over switch on load AC-23 (side handle) 4 pole 415Volts 50HZ capacity 100 Amp with sheet metal enclosure, complete all as specified and as directed by the Engineer-in-Charge. Make- Havells cat no- IHCFFE0100/Bajaj/Indoasian
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire,4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009), complete all as specified and directed by the Engineer-in-Charge. Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Supply and fixing in replacement of LT Spacers 4 Ways, made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Supply and fixing in replacement of LT Spacers 2 Ways, made out of PVC material and suitable for working on 1100 volts, complete all as specified as directed by the Engineer-in-Charge.
Replacement of existing worn out/over heated/multi jointed ACSR jumpers of LT overhead lines with PVC insulated 1100 volts cable of size 50 Sqmm , complete all as specified as directed by the Engineer-in-Charge. Note :- Length of one jumper shall be 1.5 mtr (appx)
Supply and replacement of Moulded Case Circuit breaker (MCCB) 100 Amps 35 KA of Capacity 415 V 50 Hz, 04 Pole, complete all as specified and directed by the Engineer-in-Charge.
Supply and replacement of Moulded Case Circuit breaker (MCCB) 160 Amps 35 KA of Capacity 415 V 50 Hz, 04 Pole, complete all as specified and directed by the Engineer-in-Charge.
Supply and replacement of Moulded Case Circuit breaker (MCCB) 200 Amps 36 KA of Capacity 415 V 50 Hz, 04 Pole, complete all as specified and directed by the Engineer-in-Charge.
Galvanized iron tubing 50mm bore light grade with all fittings,laid in trenches or under road crossing , or fixed alongwith poles/walls with clamps made of mild steel flat iron 25mm x 3mm including GI nuts, bolts and washers as protection pipe for cables and including taking down/out old existing pipe, complete all as specified and directed by Engineer- in-Charge.
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor , complete all as specified and directed by Engineer- in-Charge. Note - Conductor wise running metre work will be measured for payment purpose .
Painting of steel tubular pole 9 metre long including cross arms,channels,angle iron support,bracing ,clamps,GI Bracket etc. by applying two coats of aluminium paint superior quality of approved make after scraping/brushing and cleaning the rust on pole and cross arms etc. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 metre from ground level will be painted by alternate layer of black and yellow strips of 30 cm each with synthetic enameled paint, complete all as specified and directed by Engineer- in-Charge.
Numbering of poles with synthetic enameled black paint in yellow circle of 150mm dia, complete all as specified and directed by Engineer- in-Charge. Note:- The numbering shall be hand written only. Stencils embossing shall not be allowed and size of letter shall be 50 x 10 mm (height x width ).
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, complete all as specified and directed by the Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed by Engineer-in-Charge.
Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other for cable protection, complete all as specified and as directed by Engineer-in-Charge..
Supplying, laying, jointing and testing XLPE insulated, sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 2 core in trenches, on poles, through pipes, fixed to wall, under culvert or in air etc, including taking out/down and removing old unserviceable existing cable, complete all as specified and as directed by the Engineer-in-Charge.
Cutting of tree branches touching or leaning over overhead power lines and removing of cut tree branches from the site, complete all as specified and as directed by the Engineer-in-Charge.
Note :- An amount of Rs. 9,775.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S YATTOO CONTRACTORS
M/S Manzoor and Co
M/S U.K. ENTERPRISES
M/S FAYAZ AHMAD BHAT
M/S TRADE LINK
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .