REPAIR MAINT OF LT PANEL AND FEEDER PILLARS AT VARIOUS PLACES AT NDA KHADAKWASLA
2024_MES_668423_1
8847/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE KHADAKWASLA
All as per tender documents
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹92,000
Yes
11 Nov 2024
31 Aug 2024
25 Sept 2024
31 Aug 2024
20 Sept 2024
15 Sept 2024
31 Aug 2024 - 14 Sept 2024
Amount
Labour for Disconnecting existing incoming and outgoing cables from existing old / unsv LT FP / Panel after taking proper power shut down and exercising all safety precautions for human safety, removing the old / unsv LT FP / Panel complete with its accessories and setting aside at safe place and after change of CRCA Sheet 3.15 mm thick, Bus bars, Angle Iron supports etc including all cables re-terminated according to existing system with LT Panel/Feeder Pillar etc complete all as specified and directed.
S & F against Item No. 1 above in replacement outer shell of LT Feeder Pillar Panel of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL 7032 (Smoke Gray) shade with matt finish including doors, hinges and fabrication, cutting, welding, supports, clamps etc complete all as specified and directed. Note : (a) Fixing of its accessories against item No. 1 i.e. MCCBs, Busbars, Indicators, control wiring etc shall be measured and paid separately. (b) Size and design of item shall be executed as per site requirement and also approved by Engr-in-Charge.
S & F against Item No. 1 above in replacement outer shell / Inner shell of LT Feeder Pillar Panel of 2 mm thick CRCA sheet with epoxy powder coating of RAL 7032 (Smoke Gray) shade with matt finish including cutting, welding, supports, clamps etc complete all as specified and directed. Note : (a) Fixing of its accessories against item No. 1 i.e. MCCBs, Busbars, Indicators, control wiring etc shall be measured and paid separately. (b) Size and design of item shall be executed as per site requirement and also approved by Engr-in-Charge.
S & F against Item No. 1 above in replacement angle Iron Support of required size duly painted with anti corrosive black paint including welding, cutting, nuts, bolts & washers of suitable size including taking down old existing one complete all as specified and directed.
S & F in replacement Aluminium Busbrs electrolytic grade, Current rating and KA rating as per site requirement and interconnected links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. The size and thickness of busbars shall be as per sample including drilling, cutting and suitable size of galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement including Installation, testing and commissioning of Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 400 Amps current rating including required size of nut bolts for fixing of cables upto 240 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 500mmx300mmx700mm (LxWxH) including 4 Nos cable entry holes suitable for cable entry up 3.5C 240 Sqmm at bottom complete all as specified and directed Engr in Chrage.
S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement control wiring of 2.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement including Installation, testing and commissioning of Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 300 Amps current rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 400mmx200mmx500mm (LxDxH) including 4 Nos cable entry holes suitable for cable entry up 3.5C 185 Sqmm at bottom complete all as specified and directed Engr in Chrage.
S & F in replacement including Installation, testing and commissioning of Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 200 Amps current rating. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 25mmx25mmx4mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 300mmx200mmx500mm (LxDxH)including 4 Nos cable entry holes suitable for cable entry up 3.5C 95 Sqmm at bottom complete all as specified and directed Engr in Chrage.
Supply & Installation in replacement of Digital Multifunction Meter 4410 Series LED, Accuracy Class 1, with RS 485 Parameters V,A,F,PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On Hours, Phase angle, Interrupts,THD, Events (High-Low), Neutral Current including cutting of required size of panel sheet without disturbing other accessories and taking down old unsv meters etc complete all as specified and directed at site.
S & F in replacement of Current Transformer, Rated Voltage 660 Volts, AC, Frequency 50 Hz, Ratio 75/5 A, Volts Amp 10, Class 1 Accuracy, Resin Cast, Ring Type CT, Termination S1 & S2 shall be clearly marked for all three phases i.e. R, Y, B including all required control wiring of existing size copper conductor wire and opening the bus bar strip from LT Panel/Feeder Pillar and after fixing the CT in Each Phase Bus bar, nut bolted the all AL bus bar strips according to extisting system including taking down existing one of CT complete all as specified and directed at site.
S & F in replacement LED Indicator lamp Red/Yellow/Blue size as per site requirement including drilling and cutting in panel without disturbing other existing fitments and requisite control wiring etc complete all as specified and directed at site.
M & L for cutting/drilling to CRCA Sheet of 3.15mm/2mm thick for fixing of MCB/MCCB etc of suitable length/size according to site requirement without disturbing to the existig fitments complete all as specified and directed.
S & F in replacement of cylindrical panel locks of suitable size or as per sample including drilling, cutting and welding etc in panel sheets without disturbing to other existing fitments including taking down old one complete all as specified and directed.
S & F in replacement of old broken Cold rolled mild steel Hinges of existing LT Panel/Feeder Pillar/bus Bar Box etc of suitable size or as per sample including welding and painting to match with existing colour of Panel sheet etc complete all as specified and directed.
M&L for complete cleaning of the internal & external parts of LT panel, checking & testing of all the components of the panel for cable insulation, lugs, connections and replacement of including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and all as directed by Engineer-in-Charge, replacement and / or welding of existing damaged hinges of the panel, preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained, application of two coats of epoxy black paint on panel frames, complete all as directed by Engineer-in-Charge. (Note - 1. Rates included for provision of sufficient technicians for getting electric shut down and to attend the shutdown on site till completion. 2. Replacement of minor parts like lugs, nuts, bolts, connectors, locking arrangements of LT panels are included in the quoted rates. 3. Replacement of major items like MCCBs etc. shall be measured & Paid for separately).
S & F in replacement SS Nickle plated Cable Glands double compression heavy duty by opening LT Cable from Panel and fixing the Cable glands and re-terminated the same LT Cable to existing MCB/MCCB according to existing system including taking down old one complete all as specified and directed of following sizes :- (a) 3.5 Core 400 Sqmm
(b) 3.5 Core 240 to 300 Sqmm
(c) 3.5 Core 150 to 185 Sqmm
(d) 3.5 Core 95 to 120 Sqmm
(e) 3.5 Core 50 to 70 Sqmm
(f) 3.5/4 Core 25 to 35 Sqmm
S & F in replacement of Aluminium Tube terminals (Lugs), heavy duty by opening LT Cable from Panel and Crimping /fixing the Lugs with crimping tools and re-terminated the same LT Cable to existing MCB/MCCB according to existing system including taking down old one complete all as specified and directed of following sizes :- (a) 10 Sqmm -6/8
(b) 16 Sqmm -8/10
(c) 25 Sqmm -8/10/12
(d) 35 Sqmm -8/10/12
(e) 50 Sqmm -8/10/12
(f) 70 Sqmm -8/10/12
(g) 95 Sqmm -10/12/16
(h) 120 Sqmm -10/12/16
(j) 150 Sqmm -10/12/16
(k) 185 Sqmm -10/12/16
(l) 240 Sqmm -12/16
(m) 300 Sqmm -16/20
(n) 400 Sqmm -20
Supply only galvanised or cadmium plated high tensile Steel Nut-Bolts and Washers (machine made) hexagonal or square heads at one end OR as per sample given complete all as directed.
S & F in replacement of HRC Fuse link DIN Type HN, according to site requirement or as per sample given including taking down old one complete all as specified and directed of following current rating capacity :- (a) 63 Amp
S & F in replacement of HRC Fuse base suitable for DIN type Fuse Link, type HN, according to site requirement or as per sample given including drilling, cutting, screwed, welding etc complete all as specified and directed of following current rating Range /capacity :- (a) Range 63-160 Amp, type HB 160
(b) Range 80-250 Amp, type HB 250
(c) Range 200-800 Amp, type HB 800
M & L in replacement of GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment /DB/ LT Panel/ Feeder Pillars/ Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 including pit cover with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
Preventive maintenance and servicing of LT ACB, MDO Type, Rated Current 630/800A, 415 Volts, 50 Hz, AC, Indoor type by taking out/rack out the ACB from LT Panel, cleaning from inside and outside by using CRC-26 spray and applying petrolium jelly to the all moveable parts, Male /female contacts / terminals/ Spouts of ACB. Complete servicing of switchgear including checking the fixed / moving contacts of all 3 phases adjusting electrical/ electronic/mechanical components including control wiring etc all as per mfg instruction manual and standard practice including testing the ACB by injecting the fault current. The fault level setting of these ACBs shall be stepwise with its other ACBs connected in perallel so that individual swithgear will activate and trip to arrest the fault of individual circuit and fault will not travel to main Switchgear. This Job must be carried out through OEM or authorised personnel. Make of ACB : L & T as OEM Note :- S & F of spare parts of the ACB will be measured and paid separately under respective items here-in-below :-
S & F in replacement of Closing Release (CR) operating range 110V AC & DC including taking down existing one complete all as specified and as directed.
S& F in replacement of Shunt Release (SR) operating range 110V AC /110 DC including taking down existing one complete all as specified and as directed.
Preventive maintenance and servicing of LT ACB, MDO Type, Rated Current 630/800A, 415 Volts, 50 Hz, AC, Indoor type by taking out/rack out the ACB from LT Panel, cleaning from inside and outside by using CRC-26 spray and applying petrolium jelly to the all moveable parts, Male /female contacts / terminals/ Spouts of ACB. Complete servicing of switchgear including checking the fixed / moving contacts of all 3 phases adjusting electrical/ electronic/mechanical components including control wiring etc all as per mfg instruction manual and standard practice including testing the ACB by injecting the fault current. The fault level setting of these ACBs shall be stepwise with its other ACBs connected in perallel so that individual swithgear will activate and trip to arrest the fault of individual circuit and fault will not travel to main Switchgear. This Job must be carried out through OEM or authorised personnel. Make of ACB : Legrand as OEM Note :- S & F of spare parts of the ACB will be measured and paid separately under respective items here-in-below :-
S & F in replacement of Closing Coil of operating range 110 - 130 V AC /DC including taking down existing one complete all as specified and as directed.
S & F in replacement of Shunt Release (SR) operating range 110 - 130 V, AC / DC including taking down existing one complete all as specified and as directed.
S & F in replacement of Under Voltage Release (UVR) with operating range 110 - 130 V, AC / DC including taking down existing one complete all as specified and as directed.
Preventive maintenance and servicing of LT ACB, MDO Type, Rated Current 630A, 415 Volts, 50 Hz, AC, Indoor type by taking out/rack out the ACB from LT Panel, cleaning from inside and outside by using CRC-26 spray and applying petrolium jelly to the all moveable parts, Male /female contacts / terminals/ Spouts of ACB. Complete servicing of switchgear including checking the fixed / moving contacts of all 3 phases adjusting electrical/ electronic/mechanical components including control wiring etc all as per mfg instruction manual and standard practice including testing the ACB by injecting the fault current. The fault level setting of these ACBs shall be stepwise with its other ACBs connected in perallel so that individual swithgear will activate and trip to arrest the fault of individual circuit and fault will not travel to main Switchgear. This Job must be carried out through OEM or authorised personnel . Make of ACB : C & S as OEM Note :- S & F of spare parts of the ACB will be measured and paid separately under respective items here-in-below :-
S & F in repplacement of spring charged indication switch (for manual and fault tripping) including taking down existing one complete all as specified and as directed.
S & F in replacement of Shunt Release (SR) operating range 110V AC /110 DC including taking down existing one complete all as specified and as directed.
S & F replacement of spring charging motor suitable for existing ACB mechanisam operating range 250 V AC/ DC including taking down existing one complete all as specified and as directed.
S & F in replacement of Manual Change Over LT Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side single door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with spreader links/busbars extension of adequate rating including incoming and outgoing cable connection, thimbles, all joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers etc. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators. The panel shall be provided with RYB LED indicating lamps at both incoming cables. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . The overall size of the Change Over Panel shall not be less than 700mmX600mmX800mm (LxDxH) including One No. of Manual ON Load Change Over Switch of rating 315 Amp, 415Volts, 50 Hz, AC, Four Pole with staggered terminals including both side of spreder links (conforms to IEC 60947-3). The panel shall be provided for Cable entry upto size of 300 Sqmm cable from bottom side for 04 Nos of Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip. Note : Before manufacturing drawing and design of panel shall be approved by Engr-in-charge.
S & F in replacement of Manual Change Over LT Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side single door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with spreader links/busbars extension of adequate rating including incoming and outgoing cable connection, thimbles, all joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators. The panel shall be provided with RYB LED indicating lamps at both incoming cables. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . The overall size of the Change Over Panel shall not less than 700mmX600mmX800mm (LxDxH) including One No. of Manual ON Load Change Over Switch of rating 200 Amp, 415Volts, 50 Hz, AC, Four Pole with staggered terminals including both side of spreder links (conforms to IEC 60947-3). The panel shall be provided for Cable entry upto size of 120 Sqmm cable from bottom side for 04 Nos of Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip. Note : Before manufacturing drawing and design of panel shall be approved by Engr-in-charge.
S & F in replacement On load change over switch Four Pole with steel sheet enclosure and staggered terminals of 160 Amps current rating, 415 Volts, 50 Hz AC conforming to IEC 60947-3 including suitable size of spreader links on both side with galvanised or cadmium plated high tensile nuts, bolts and washers etc and also suitable for wall/surface mounting arrangement complete all as specified and directed.
S & F in replacement On load change over switch Four Pole with steel sheet enclosure and staggered terminals of 200 Amps current rating, 415 Volts, 50 Hz AC conforming to IEC 60947-3 including suitable size of spreader links on both side with galvanised or cadmium plated high tensile nuts, bolts and washers etc and also suitable for wall/surface mounting arrangement complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 25 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 40 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 350 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 400 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 630 Amp, 50 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply & install in replacement of ACB, 630 Amps, 4 Pole, 415 Volts, 50 KA, Manual Draw Out (MDO) type, as per IS/IEC-60947-2 with microprocessor based adjustable LSIG & temperature rise protection consisting of digital LCD display with battery backup, inbuilt LED indication and alarm for temp rise, current metering, RS 485 Port and UV Release etc including test certificate of ACB. Rates also include for fixing to LT Panel including cutting, welding to CRCA sheet and necessary busbar arrangement etc including taking down existing one complete all as specified and directed.
S & F in replacement of Manual Change Over LT Panel weather proof outdoor type single door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-54, front side single door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with spreader links/busbars extension of adequate rating including incoming and outgoing cable connection, thimbles, all joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts and washers. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured for indicators. The panel shall be provided with RYB LED indicating lamps at both incoming cables. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . The overall size of the Change Over Panel shall not less than 500mmX400mmX500mm (LxBxH) including One No. of Manual ON Load Change Over Switch of rating 160 Amp, 415Volts, 50 Hz, AC, Four Pole with staggered terminals including both side of spreder links (conforms to IEC 60947-3). The panel shall be provided for Cable entry upto size of 120 Sqmm cable from bottom side for 04 Nos of Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip. Note : Before manufacturing drawing and design of panel shall be approved by Engr-in-charge.
S & F in replacement including testing and commissioning Sub Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 200 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 700mmX300mmX800mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 100 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos.
S & F in replacement including testing and commissioning Sub Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 250 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 700mmX300mmX800mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 06 Nos.
S & F in replacement including testing and commissioning Sub Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 200 Amp current. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX300mmX1000mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 Nos. (c) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos.
S & F in replacement including testing and commissioning Sub Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 250 Amp current. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1200mmX400mmX1000mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 Nos. (c) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 600 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1600mmX550mmX1700mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts,400 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01No. (c) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 Nos. (d) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 Nos. (e) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 250 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX400mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 125 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (c) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. (d) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX400mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 125 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (c) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. (d) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 400 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1600mmX400mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. (c) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. (d) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1600mmX400mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 No. (c) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (d) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 05 Nos.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 300 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB, LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1600mmX400mmX1000mm (LxBxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (c) MCCB 4 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (d) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (e) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 03 Nos.
S & F in replacement including testing and commissioning Sub Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 250 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided with digital multifunction meter 4410 Series, Accuracy Class 1 with RS 485 Parameters with cast Resign CTs and RYB LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 900mmX400mmX1000mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 03 No. (c) MCB 4 Pole, 415 Volts, 63 Amp, 10 KA breaking capacity conforms to IEC 60947-2. (Outgoing) - 02
S & F in replacement Busbar panel weather proof outdoor type single door, fabricated out of 2 mm thick CRCA sheet with epoxy powder coating of RAL-7035 ( Siemens Gray) shade with matt finish with seven tank pre treatment process. The Panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, Gaskets between all adjacent units and beneath all covers shall be provided to render the joints dust proof. All doors and covers shall be provided with cylindrical panel locks and shall be fully gasketed with neoprene rubber and shall be lockable. The panel shall be provided with aluminium bus bars electrolytic grade of 250 Amps current rating including required size of nut bolts for fixing of cables upto 25 Sqmm. The bus bars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & black colour coding and fix horizontally. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in a dedicated compartment. All joints and connection shall be done with galvanised or cadmium plated high tensile nuts, bolts, washers and AL Lugs etc. The panel shall be provided with 04 Nos 50mmx50mmx5mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint including earth work and grouted in PCC 1:3:6 at suitable depth as per site requirement including taking down existing one. The overall size of the Busbar panel shall not be less than 500mmx400mmx600mm (LxWxH) including 10 Nos cable entry holes suitable for cable entry up 3.5C 25 Sqmm at bottom complete all as specified and directed Engr in Chrage. (a) MCB DP 230 Volts, 40 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 3 No. (b) MCB SP 230 Volts, 40 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 10 No.
S & F in replacement including testing and commissioning LT Feeder Panel weather proof outdoor type double door, fabricated out of 3.15 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens Gray) shade with matt finish with seven tank pre treatment process. The panel shall be fabricated by CPRI approved manufacturer only. The panel shall be compartmentized design totally enclosed, dust and vermin proof, conforming to degree of protection IP-55, front side double door type with locking arrangement for front side and nut bolt fitting for back side, comprising of gaskets between all adjacent units and beneath all covers shall be fully gasketed with neoprene rubber and ventilation arrangement for heat dissipation from both side of panel. The panel shall be provided with aluminium bus bars, electrolytic grade of 250 Amp current rating. The busbars and Interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB & Black colour coding. The bus bars shall be supported on unbreakable, non-hygroscopic SMC insulated supports at sufficiently close intervals to prevent busbars sag and shall be housed in dedicated compartment. The panel shall be prewired with FRLS PVC insulated copper conductor cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanized or cadmium plated high tensile nuts, bolts and washers including Lugs etc. The panel shall be provided RYB, LED indicating lamps at incoming. The panel shall be provided with manufacturer's name plate, skull & bones danger notice board etc. The panel shall be provided 4 Nos 50x50x5mm thick angle iron supports of not less than each 1.0 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement . All MCCBs shall be provided with spreader links with phase separators on both side complete all as specified and as directed. The overall size of the panel shall not less than 1500mmX400mmX1000mm (LxDxH). The panel shall be provided for Cable entry from bottom side for each Cable including 2 Nos of Earthing Terminals one on each side of the Panel with GI earth strip and including following accessories:- Note : Before manufacturing drawing and design of panel including size & length of busbar shall be approved by Engr-in-charge. (a) MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with thermal adjustable with Ics = 100% of Icu including suitable size of spreader links on both side. (Incoming) - 01 No. (b) MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 02 Nos. (c) MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity with thermal adjustable with Ics = 100% of Icu including suitable size of spreader links on both side. (Outgoing) - 01 No. (d) MCB 4 Pole, 415 Volts, 40 Amp, 10 KA Breaking capacity conforms to IEC 60947-2. (Outgoing) - 02 Nos.
S & F in replacement MCCB 4 Pole, 415 Volts, 25 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 40 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 400 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 630 Amp, 50 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 40 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 63 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 80 Amp, 16 KA Breaking capacity, thermal adjustable type with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 100 Amp, 16 KA Breaking capacity with adjustable thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed. .
S & F in replacement MCCB 3 Pole, 415 Volts, 125 Amp, 16 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 160 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 3 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 200 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
S & F in replacement MCCB 4 Pole, 415 Volts, 250 Amp, 36 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu with extended rotary handle (ROH) mechanism, notifying ON/OFF/TRIP position of MCCB including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply and Laying in replacement including testing & commissioning of LT UG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including termination at both side of LT Panel/Feeder Pillar/Bus Bars/Change over panels etc with suitable size of AL Lugs, Nut-Bolts and washers etc including taking down existing one complete of size 3.5 Core 240 Sqmm all as specified and as directed.:- Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item.
Excavation in trenches, n.exc 1.5m wide and n. exc 1.5 m depth and getting out in any type of soil for foundation of pole, stay, laying of cable and pipe etc complete all as specified and as directed.
Returning and filling, including spreading and well ramming in layers n exc 25 cm all as specified and directed.
Removing excavated material a distance n. exc 50 m & depositing where directed at a level n. exc 1.5 m above the starting point.
M&L for dry crush sand cushioing to under ground cable intrenches incl spreading, leveling and hand punning complete all specified. Note : For measurement purpose punned thickness shall be considered.
Supply and laying burnt clay fly ash building modular bricks, designation 75 (Kg/Sqcm), laid in right angle along the cable for protection of cable, complete all as specified and directed.
M & L in replacement for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to LT Panel/Feeder Pillar/Sub Feeder Pillar/Change over Panel etc as required including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover with lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh, etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
S & F in replacement Switch disconnector fuse unit 200 Amps, TPN, 415 Volts with steel sheet enclosure, suitable for wall / angle iron frame structure including 200 Amp HRC fuse link DIN type including taking down existing one complete all as specified and directed.
S & F in replacement of 4 Way TPN DB-VTPN 160 Amp MCCB DB's, as per IEC 61439-3, suitable for flush mounting and surface mounting with 250 amp copper busbar for each phase, 2 neutrals bar, 2 earth busbar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, improved Pan assembly for ease of installation, IP-30 with provision for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down existing one complete all as specified and directed.
S & F in replacement of 12 Way TPN DB-VTPN 160 Amp MCCB DB's, as per IEC 61439-3, suitable for flush mounting and surface mounting with 250 amp copper busbar for each phase, 2 neutrals bar, 2 earth busbar and cable ties for cable management, fully insulated busbar & shrouded neutral bars, improved Pan assembly for ease of installation, double door, IP-43 with provision for 160 Amp MCCB as incomer and SP/TP MCB's as outgoing including taking down existing one complete all as specified and directed.
S & F in replacement of 4 Module Plexo boxes conform to EN 60439-3, wheather proof cabinets IP 65, IK-09-Cl-II, door and cabinet fully reversible, removable chasis and faceplates from 2-row versions up, position rail for modular products and moulded cases, spacing between rail 150 mm box colour light grey L750A, cover colour dark grey R746A including taking down existing one complete all as specified and directed.
S & F in replacement of 36 Modules (3 rows x 12 modules) Plexo boxes conform to EN 60439-3, wheather proof cabinets IP 65, IK-09-Cl-II, door and cabinet fully reversible, removable chasis and faceplates from 2-row versions up, position rail for modular products and moulded cases, spacing between rail 150 mm box colour light grey L750A, cover colour dark grey R746A including taking down existing one complete all as specified and directed.
S & F in replacement Switch disconnector fuse unit 63 Amps, TPN, 415 Volts with steel sheet enclosure, suitable for wall / angle iron frame structure including 63 Amp HRC fuse link DIN type including taking down existing one complete all as specified and directed.
S & F in replacement of MCB 4 Pole, 415 Volts, 50 Hz, 63 Amp, 10 KA, C-Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed.
S & F in replacement of MCB 3 Pole, 415 Volts, 50 Hz, 63 Amp, 10 KA, C-Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed.
S & F in replacement of MCB SPN, 230 Volts, 50 Hz, 40 Amp, 10 KA, C Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed.
S & F in replacement of MCB Single Pole, 230 Volts, 50 Hz, 40 Amp, 10 KA, C-Curve conforms to IS/IEC 60898 including taking down existing one and install with mounting rail, links etc complete all as specified and directed.
S & F in replacement Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situationfor loop earthing etc. Size 25 x 4 mm GI strip complete all as specified and directed.
M & L for demolition of unreinforced PCC, floors etc in any position and any description including removal of demolished material complete all as specified and directed.
M & L for plain concrete cement 1:2:4 type B2 using 40mm graded coarse aggregate for foundation of Feeder Panels/Path Way etc including necessary form work/Shuttering etc complete all as specified and directed.
M & L for preparation of existing surface of ACB Panel of sub stn building and Supporting angle iron of ACB panel approx size 1.0x 0.8x1.3 (LxWxH) by srapping down, peeled off old paint, cleaning etc and applying two coat of existing siemens gray paint to Panel Sheet including cleaning of Panels from inside by blowing of compressed air etc complete all as specified and directed.
M & L for Boring of holes under Traxi Track, road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure and necessary excavation work up to required depth, length and wiidth for placing of boring machine both side of road complete all as specified and as directed at site.
Supply & Fix including commissioning digital automatic timer switch distribution panel board, factory assembled in powder coated steel sheet enclosure, comprising of 4P MCB, 40 Amps & 3 Pole power contactor 40/50 Amps and 230V digital time switch for controlling LED street lights, including earth work for fixing Timer switch distribution panel board and shall be provided 4 Nos 20x20x3mm thick angle iron supports of not less than each 0.6 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth complete all as specified and directed at site.
M & L for Shifting & Transportation of LT Panel/Feeder Pillar from existing place to directed place (any where inside NDA Campus) including demolation of PCC/ concrete of any description and other accessories i.e. incoming/outgoing cables including necessary earthwork & PCC 1:3:6 as per site requirement for grouting LT Panel /Feeder Pillar at suitable depth at new place including open all cables from old LT panel and re-terminated all cables with new LT Panel complete all as specified and directed.
Tejas Enterprises (BID ID -3100727)
KESARI AND SONS (BID ID -3100557)
GRID SYSTEMS (BID ID -3101765)
SUNIT TRADING CORPORATION (BID ID -3101921)
M/S P D TUPE (BID ID -3102157)
SONU ENTERPRISES (BID ID -3098642)
Deccan Enterprises (BID ID -3101818)
Adinath Technical Services (BID ID -3101651)
H S TAKHI (BID ID -3102196)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .